Published in: Child's Nervous System 8/2012

01-08-2012 | Case Report

The use of harmonic scalpel in spinal surgery with contraindication to the use of monopolar electrocautery: a case report in a 14-year-old girl with a primary generalized dystonia and a 100° thoracic scoliosis

Authors: Benjamin Bouyer, Manon Bachy, Anne-Isabelle Vermesch, Diane Doummar, Philippe Coubes, Raphaël Vialle

Published in: Child's Nervous System | Issue 8/2012

Login to get access

Excerpt

Many techniques are reported to decrease blood loss in children and adolescents undergoing extensive spinal surgeries. The reduction of blood loss and subsequent reduction of allogenic blood transfusion is a desired outcome in such surgical programs. In patients with severe neuromuscular scoliosis, this becomes a greater concern due to a variety of factors such as the need for extensive surgical exposure and the longer intraoperative time [18]. A lot of pharmacological, anesthetic, and surgical techniques including preoperative autologous blood donation [1], human recombinant erythropoietin [17, 27], intraoperative blood salvage techniques, and topical and systemic hemostatic agents [8, 20] are employed to reduce intraoperative and postoperative bleeding. The extensive use of monopolar electrocautery has been proposed as a safe and rapid technique to perform posterior exposure of the spine [18]. No significant differences with operative times, intraoperative blood loss, and postoperative hemoglobin levels have been demonstrated in orthopedic patients using bipolar sealer devices for intraoperative haemostasis [3, 11, 13]. In some patients with implanted pacemaker of brain stimulator, electrocautery has a potential risk of serious implanted hardware dysfunction [2, 6, 19, 24, 25]. In these patients, the use of harmonic scalpel, using high-frequency mechanical vibrations to cut and coagulate at the same time, could be an alternative technique to the use of monopolar electrocautery [14, 16]. We report the case of a 14-year-old girl previously treated for a severe acquired dystonia by pallidal bilateral stimulation. The presence of brain stimulators contraindicated the use of monopolar electrocautery for a requested extensive scoliosis surgery. In this case, the successful use of harmonic scalpel is reported and discussed. …
Literature
1.
go back to reference Anand N, Idio FG Jr, Remer S, Hoppenfeld S (1998) The effects of perioperative blood salvage and autologous blood donation on transfusion requirements in scoliosis surgery. J Spinal Disord Tech 11:532–534 Anand N, Idio FG Jr, Remer S, Hoppenfeld S (1998) The effects of perioperative blood salvage and autologous blood donation on transfusion requirements in scoliosis surgery. J Spinal Disord Tech 11:532–534
2.
go back to reference Bales JG, Colon J, Ramadhyani U, LeDoux E, Bennett JT (2007) Electrocautery-induced asystole in a scoliosis patient with a pacemaker. J Pediatr Orthop 16:19–22CrossRef Bales JG, Colon J, Ramadhyani U, LeDoux E, Bennett JT (2007) Electrocautery-induced asystole in a scoliosis patient with a pacemaker. J Pediatr Orthop 16:19–22CrossRef
3.
go back to reference Barsoum WK, Klika AK, Murray TG, Higuera C, Lee HH, Krebs VE Prospective randomized evaluation of the need for blood transfusion during primary total hip arthroplasty with use of a bipolar sealer. The Journal of bone and joint surgery 93: 513–518 Barsoum WK, Klika AK, Murray TG, Higuera C, Lee HH, Krebs VE Prospective randomized evaluation of the need for blood transfusion during primary total hip arthroplasty with use of a bipolar sealer. The Journal of bone and joint surgery 93: 513–518
4.
go back to reference Brazio PS, Laird PC, Xu C, Gu J, Burris NS, Brown EN, Kon ZN, Poston RS (2008) Harmonic scalpel versus electrocautery for harvest of radial artery conduits: reduced risk of spasm and intimal injury on optical coherence tomography. J Thorac Cardiovasc Surg 136:1302–1308PubMedCrossRef Brazio PS, Laird PC, Xu C, Gu J, Burris NS, Brown EN, Kon ZN, Poston RS (2008) Harmonic scalpel versus electrocautery for harvest of radial artery conduits: reduced risk of spasm and intimal injury on optical coherence tomography. J Thorac Cardiovasc Surg 136:1302–1308PubMedCrossRef
5.
go back to reference Cakir B, Ulmar B, Schmidt R, Kelsch G, Geiger P, Mehrkens HH, Puhl W, Richter M (2006) Efficacy and cost effectiveness of harmonic scalpel compared with electrocautery in posterior instrumentation of the spine. Eur Spine J 15:48–54PubMedCrossRef Cakir B, Ulmar B, Schmidt R, Kelsch G, Geiger P, Mehrkens HH, Puhl W, Richter M (2006) Efficacy and cost effectiveness of harmonic scalpel compared with electrocautery in posterior instrumentation of the spine. Eur Spine J 15:48–54PubMedCrossRef
6.
go back to reference Delhumeau A, Ronceray S, Moreau X, Cottineau C, Cavellat M (1988) Final arrest of a pacemaker after use of electrocautery. Annales francaises d’anesthesie et de reanimation 7:162–164PubMedCrossRef Delhumeau A, Ronceray S, Moreau X, Cottineau C, Cavellat M (1988) Final arrest of a pacemaker after use of electrocautery. Annales francaises d’anesthesie et de reanimation 7:162–164PubMedCrossRef
7.
go back to reference Deo S, Hazarika S, Shukla NK, Kar M, Samaiya A (2005) A prospective randomized trial comparing harmonic scalpel versus electrocautery for pectoralis major myocutaneous flap dissection. Plast Reconstr Surg 115:1006–1009PubMedCrossRef Deo S, Hazarika S, Shukla NK, Kar M, Samaiya A (2005) A prospective randomized trial comparing harmonic scalpel versus electrocautery for pectoralis major myocutaneous flap dissection. Plast Reconstr Surg 115:1006–1009PubMedCrossRef
8.
go back to reference Grant JA, Howard J, Luntley J, Harder J, Aleissa S, Parsons D (2009) Perioperative blood transfusion requirements in pediatric scoliosis surgery: the efficacy of tranexamic acid. J Pediatr Orthop 29:300–304PubMedCrossRef Grant JA, Howard J, Luntley J, Harder J, Aleissa S, Parsons D (2009) Perioperative blood transfusion requirements in pediatric scoliosis surgery: the efficacy of tranexamic acid. J Pediatr Orthop 29:300–304PubMedCrossRef
9.
go back to reference Konno R, Akahira J, Igarashi T, Yamakawa H, Sato S, Yajima A (1999) Conization of the cervix using harmonic scalpel. Tohoku J Exp Med 189:171–178PubMedCrossRef Konno R, Akahira J, Igarashi T, Yamakawa H, Sato S, Yajima A (1999) Conization of the cervix using harmonic scalpel. Tohoku J Exp Med 189:171–178PubMedCrossRef
10.
go back to reference Marulanda GA, Ragland PS, Seyler TM, Mont MA (2005) Reductions in blood loss with use of a bipolar sealer for hemostasis in primary total knee arthroplasty. Surg Tech Int 14:281–286 Marulanda GA, Ragland PS, Seyler TM, Mont MA (2005) Reductions in blood loss with use of a bipolar sealer for hemostasis in primary total knee arthroplasty. Surg Tech Int 14:281–286
11.
go back to reference Marulanda GA, Ulrich SD, Seyler TM, Delanois RE, Mont MA (2008) Reductions in blood loss with a bipolar sealer in total hip arthroplasty. Expet Rev Med Dev 5:125–131CrossRef Marulanda GA, Ulrich SD, Seyler TM, Delanois RE, Mont MA (2008) Reductions in blood loss with a bipolar sealer in total hip arthroplasty. Expet Rev Med Dev 5:125–131CrossRef
12.
go back to reference Marulanda GA, Krebs VE, Bierbaum BE, Goldberg VM, Ries M, Ulrich SD, Seyler TM, Mont MA (2009) Hemostasis using a bipolar sealer in primary unilateral total knee arthroplasty. Am J Orthoped (Belle Mead, NJ) 38:E179–183 Marulanda GA, Krebs VE, Bierbaum BE, Goldberg VM, Ries M, Ulrich SD, Seyler TM, Mont MA (2009) Hemostasis using a bipolar sealer in primary unilateral total knee arthroplasty. Am J Orthoped (Belle Mead, NJ) 38:E179–183
13.
go back to reference Morris MJ, Berend KR, Lombardi AV Jr (2010) Hemostasis in anterior supine intermuscular total hip arthroplasty: pilot study comparing standard electrocautery and a bipolar sealer. Surg Tech Int 20:352–356 Morris MJ, Berend KR, Lombardi AV Jr (2010) Hemostasis in anterior supine intermuscular total hip arthroplasty: pilot study comparing standard electrocautery and a bipolar sealer. Surg Tech Int 20:352–356
14.
go back to reference Nandalan SP, Vanner RG (2004) Use of the harmonic scalpel in a patient with a permanent pacemaker. Anaesthesia 59:621PubMedCrossRef Nandalan SP, Vanner RG (2004) Use of the harmonic scalpel in a patient with a permanent pacemaker. Anaesthesia 59:621PubMedCrossRef
15.
go back to reference Ortega J, Sala C, Flor B, Lledo S (2004) Efficacy and cost-effectiveness of the UltraCision harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial. J Laparoendosc Adv Surg Tech 14:9–12CrossRef Ortega J, Sala C, Flor B, Lledo S (2004) Efficacy and cost-effectiveness of the UltraCision harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial. J Laparoendosc Adv Surg Tech 14:9–12CrossRef
16.
go back to reference Poole G, Biggar M, Moss D (2010) Use of the harmonic scalpel for breast surgery in patients with a cardiac pacemaker—a tip. Breast J 16:108–109PubMedCrossRef Poole G, Biggar M, Moss D (2010) Use of the harmonic scalpel for breast surgery in patients with a cardiac pacemaker—a tip. Breast J 16:108–109PubMedCrossRef
17.
go back to reference Regis D, Franchini M, Corallo F, Bartolozzi P (2004) Recombinant human erythropoietin in pediatric patients: efficacy in facilitating autologous blood donation in spinal deformity surgery. La Chirurgia Degli Organi di Movimento 89:299–303PubMed Regis D, Franchini M, Corallo F, Bartolozzi P (2004) Recombinant human erythropoietin in pediatric patients: efficacy in facilitating autologous blood donation in spinal deformity surgery. La Chirurgia Degli Organi di Movimento 89:299–303PubMed
18.
go back to reference Samdani AF, Torre-Healy A, Asghar J, Herlich AM, Betz RR (2008) Strategies to reduce blood loss during posterior spinal fusion for neuromuscular scoliosis: a review of current techniques and experience with a unique bipolar electrocautery device. Surg Tech Int 17:243–248 Samdani AF, Torre-Healy A, Asghar J, Herlich AM, Betz RR (2008) Strategies to reduce blood loss during posterior spinal fusion for neuromuscular scoliosis: a review of current techniques and experience with a unique bipolar electrocautery device. Surg Tech Int 17:243–248
19.
go back to reference Sazhin AV, Tiagunov AE, Pervova EV, Aleksandrov AN, Rogov KA, Zlotnikova AD, Zhdanov AM (2010) General surgical procedures in patients with electrical pacemaker. Khirurgiia 9–16 Sazhin AV, Tiagunov AE, Pervova EV, Aleksandrov AN, Rogov KA, Zlotnikova AD, Zhdanov AM (2010) General surgical procedures in patients with electrical pacemaker. Khirurgiia 9–16
20.
go back to reference Schouten ES, van de Pol AC, Schouten AN, Turner NM, Jansen NJ, Bollen CW (2009) The effect of aprotinin, tranexamic acid, and aminocaproic acid on blood loss and use of blood products in major pediatric surgery: a meta-analysis. Pediatr Crit Care Med 10:182–190PubMedCrossRef Schouten ES, van de Pol AC, Schouten AN, Turner NM, Jansen NJ, Bollen CW (2009) The effect of aprotinin, tranexamic acid, and aminocaproic acid on blood loss and use of blood products in major pediatric surgery: a meta-analysis. Pediatr Crit Care Med 10:182–190PubMedCrossRef
21.
go back to reference Sebag F, Fortanier C, Ippolito G, Lagier A, Auquier P, Henry JF (2009) Harmonic scalpel in multinodular goiter surgery: impact on surgery and cost analysis. J Laparoendosc Adv Surg Tech 19:171–174CrossRef Sebag F, Fortanier C, Ippolito G, Lagier A, Auquier P, Henry JF (2009) Harmonic scalpel in multinodular goiter surgery: impact on surgery and cost analysis. J Laparoendosc Adv Surg Tech 19:171–174CrossRef
22.
go back to reference Sherman JA, Davies HT (2000) Ultracision: the harmonic scalpel and its possible uses in maxillofacial surgery. Br J Oral Maxillofac Surg 38:530–532PubMedCrossRef Sherman JA, Davies HT (2000) Ultracision: the harmonic scalpel and its possible uses in maxillofacial surgery. Br J Oral Maxillofac Surg 38:530–532PubMedCrossRef
23.
go back to reference Stoff A, Reichenberger MA, Richter DF (2007) Comparing the ultrasonically activated scalpel (Harmonic) with high-frequency electrocautery for postoperative serous drainage in massive weight loss surgery. Plast Reconstr Surg 120:1092–1093PubMedCrossRef Stoff A, Reichenberger MA, Richter DF (2007) Comparing the ultrasonically activated scalpel (Harmonic) with high-frequency electrocautery for postoperative serous drainage in massive weight loss surgery. Plast Reconstr Surg 120:1092–1093PubMedCrossRef
24.
go back to reference Takimoto K, Arai F, Kita T, Sasaki S (2009) Anesthetic management for nephrectomy using a monopolar electrocautery in a patient implanted with a biventricular pacemaker. Masui 58:96–99PubMed Takimoto K, Arai F, Kita T, Sasaki S (2009) Anesthetic management for nephrectomy using a monopolar electrocautery in a patient implanted with a biventricular pacemaker. Masui 58:96–99PubMed
25.
go back to reference Tarichko Iu V, Baranovich V, Maksimkin DA, Illarionova EV, Veretnik GI, Faibushevich AG (2010) Surgical manipulations in patients with permanent pacemaker. Khirurgiia 11–15 Tarichko Iu V, Baranovich V, Maksimkin DA, Illarionova EV, Veretnik GI, Faibushevich AG (2010) Surgical manipulations in patients with permanent pacemaker. Khirurgiia 11–15
26.
go back to reference Uchida T, Bando K, Minatoya K, Sasako Y, Kobayashi J, Kitamura S (2001) Pericardiectomy for constrictive pericarditis using the harmonic scalpel. Ann Thorac Surg 72:924–925PubMedCrossRef Uchida T, Bando K, Minatoya K, Sasako Y, Kobayashi J, Kitamura S (2001) Pericardiectomy for constrictive pericarditis using the harmonic scalpel. Ann Thorac Surg 72:924–925PubMedCrossRef
27.
go back to reference Vitale MG, Privitera DM, Matsumoto H, Gomez JA, Waters LM, Hyman JE, Roye DP Jr (2007) Efficacy of preoperative erythropoietin administration in pediatric neuromuscular scoliosis patients. Spine 32:2662–2667PubMedCrossRef Vitale MG, Privitera DM, Matsumoto H, Gomez JA, Waters LM, Hyman JE, Roye DP Jr (2007) Efficacy of preoperative erythropoietin administration in pediatric neuromuscular scoliosis patients. Spine 32:2662–2667PubMedCrossRef
Metadata
Title
The use of harmonic scalpel in spinal surgery with contraindication to the use of monopolar electrocautery: a case report in a 14-year-old girl with a primary generalized dystonia and a 100° thoracic scoliosis
Authors
Benjamin Bouyer
Manon Bachy
Anne-Isabelle Vermesch
Diane Doummar
Philippe Coubes
Raphaël Vialle
Publication date
01-08-2012
Publisher
Springer-Verlag
Published in
Child's Nervous System / Issue 8/2012
Print ISSN: 0256-7040
Electronic ISSN: 1433-0350
DOI
https://doi.org/10.1007/s00381-012-1757-1

Other articles of this Issue 8/2012

Child's Nervous System 8/2012 Go to the issue