Abstract

Objective

3-Dimensional (3-D) visualization by the surgeon is considered to be one of the major advantages of robotic prostatectomy. We undertook this study to see if passing on this technology to the surgical assistants would improve the efficiency of their assistance.

Materials and methods

The study was conducted in consecutive patients undergoing robotic radical prostatectomy by the same team, in one month at our center. A 3-D head mounted device (HMD) was used by the left and/or right assistant. Video recording from these patients were studied by a blinded observer with prior training in laparoscopic surgery for the efficiency of laparoscopic moves by the two assistants. These moves were scored on a point scoring system from 0 to 100 with 100 signifying the best possible performance.

Results

After exclusions, 26 videos were available for review. Each patient had a right and left-sided assistant. The right-sided assistant had prior experience in Laparoscopic Urology, and the left-sided assistant had a relatively limited laparoscopic experience. The mean scores for the left assistant improved from 76.3 to 84.6 with the use of 3-D visualization (p < 0.002), while the improvement for the right assistant was from 84.1 to 86.9 (NS).

Conclusions

The use of 3-D visualization possibly improves the efficiency of assistance during robotic radical prostatectomies, for the assistant with limited experience in laparoscopic surgery. Because of the high-quality 3-D vision provided, these HMDs have the potential to be used as teaching aids in the robotic lab.
Literature
1.
go back to reference Satava R (1993) 3-D vision technology applied to advanced minimally invasive surgery systems. Surg Endosc 7(5):429–431PubMedCrossRef Satava R (1993) 3-D vision technology applied to advanced minimally invasive surgery systems. Surg Endosc 7(5):429–431PubMedCrossRef
2.
go back to reference van Bergen P, Kunert W, Bessell J, Buess GF (1998) Comparative study of two-dimensional and three-dimensional vision systems for minimally invasive surgery. Surg Endosc 12(7):948–954PubMedCrossRef van Bergen P, Kunert W, Bessell J, Buess GF (1998) Comparative study of two-dimensional and three-dimensional vision systems for minimally invasive surgery. Surg Endosc 12(7):948–954PubMedCrossRef
3.
go back to reference Bhayani SB, Andriole GL (2005) Three-dimensional (3D) vision: does it improve laparoscopic skills? An assessment of a 3D head-mounted visualization system. Rev Urol 7(4):211–214PubMed Bhayani SB, Andriole GL (2005) Three-dimensional (3D) vision: does it improve laparoscopic skills? An assessment of a 3D head-mounted visualization system. Rev Urol 7(4):211–214PubMed
4.
go back to reference Taffinder N, Smith SG, Huber J, Russell RC, Darzi A (1999) The effect of a second-generation 3D endoscope on the laparoscopic precision of novices and experienced surgeons. Surg Endosc 13(11):1087–1092PubMedCrossRef Taffinder N, Smith SG, Huber J, Russell RC, Darzi A (1999) The effect of a second-generation 3D endoscope on the laparoscopic precision of novices and experienced surgeons. Surg Endosc 13(11):1087–1092PubMedCrossRef
5.
go back to reference Tevaearai HT, Mueller XM, von Segesser LK (2000) 3-D vision improves performance in a pelvic trainer. Endoscopy 32(6):464–468PubMedCrossRef Tevaearai HT, Mueller XM, von Segesser LK (2000) 3-D vision improves performance in a pelvic trainer. Endoscopy 32(6):464–468PubMedCrossRef
6.
go back to reference van Bergen P, Kunert W, Schurr MO, Buess GF (1996) Comparative study of endoscopic 2-D and 3-D imaging systems. Langenbecks Arch Chir Suppl Kongressbd 113:634–637PubMed van Bergen P, Kunert W, Schurr MO, Buess GF (1996) Comparative study of endoscopic 2-D and 3-D imaging systems. Langenbecks Arch Chir Suppl Kongressbd 113:634–637PubMed
7.
go back to reference Tewari A, Takenaka A, Mtui E, Horninger W, Peschel R, Bartsch G et al (2006) The proximal neurovascular plate and the tri-zonal neural architecture around the prostate gland: importance in the athermal robotic technique of nerve-sparing prostatectomy. BJU Int 98(2):314–323PubMedCrossRef Tewari A, Takenaka A, Mtui E, Horninger W, Peschel R, Bartsch G et al (2006) The proximal neurovascular plate and the tri-zonal neural architecture around the prostate gland: importance in the athermal robotic technique of nerve-sparing prostatectomy. BJU Int 98(2):314–323PubMedCrossRef
8.
go back to reference Munz Y, Moorthy K, Dosis A, Hernandez JD, Bann S, Bello F et al (2004) The benefits of stereoscopic vision in robotic-assisted performance on bench models. Surg Endosc 18(4):611–616PubMedCrossRef Munz Y, Moorthy K, Dosis A, Hernandez JD, Bann S, Bello F et al (2004) The benefits of stereoscopic vision in robotic-assisted performance on bench models. Surg Endosc 18(4):611–616PubMedCrossRef
9.
go back to reference Badani KK, Bhandari A, Tewari A, Menon M (2005) Comparison of two-dimensional and three-dimensional suturing: is there a difference in a robotic surgery setting? J Endourol 19(10):1212–1215PubMedCrossRef Badani KK, Bhandari A, Tewari A, Menon M (2005) Comparison of two-dimensional and three-dimensional suturing: is there a difference in a robotic surgery setting? J Endourol 19(10):1212–1215PubMedCrossRef
10.
go back to reference Blavier A, Gaudissart Q, Cadiere GB, Nyssen AS (2006) Impact of 2D and 3D vision on performance of novice subjects using da Vinci robotic system. Acta Chir Belg 106(6):662–664PubMed Blavier A, Gaudissart Q, Cadiere GB, Nyssen AS (2006) Impact of 2D and 3D vision on performance of novice subjects using da Vinci robotic system. Acta Chir Belg 106(6):662–664PubMed
11.
go back to reference Byrn JC, Schluender S, Divino CM, Conrad J, Gurland B, Shlasko E et al (2007) Three-dimensional imaging improves surgical performance for both novice and experienced operators using the da Vinci Robot System. Am J Surg 193(4):519–522PubMedCrossRef Byrn JC, Schluender S, Divino CM, Conrad J, Gurland B, Shlasko E et al (2007) Three-dimensional imaging improves surgical performance for both novice and experienced operators using the da Vinci Robot System. Am J Surg 193(4):519–522PubMedCrossRef
12.
go back to reference Heinrichs W, Lukoff B, Youngblood P, Dev P, Shavelson R, Hasson HM et al (2007) Criterion-based training with surgical simulators: proficiency of experienced surgeons. J Soc Laparoendosc Surg 11(3):273–302 Heinrichs W, Lukoff B, Youngblood P, Dev P, Shavelson R, Hasson HM et al (2007) Criterion-based training with surgical simulators: proficiency of experienced surgeons. J Soc Laparoendosc Surg 11(3):273–302
13.
go back to reference Matsuda T, Ono Y, Terachi T, Naito S, Baba S, Miki T et al (2006) The endoscopic surgical skill qualification system in urological laparoscopy: a novel system in Japan. J Urol 176(5):2168–2172 discussion 72PubMedCrossRef Matsuda T, Ono Y, Terachi T, Naito S, Baba S, Miki T et al (2006) The endoscopic surgical skill qualification system in urological laparoscopy: a novel system in Japan. J Urol 176(5):2168–2172 discussion 72PubMedCrossRef
Metadata
Title
Does 3-Dimensional (3-D) visualization improve the quality of assistance during robotic radical prostatectomy?
Authors
Rajan Ramanathan
Juan I. Martinez Salamanca
Anil Mandhani
Robert A. Leung
Sandhya R. Rao
Roy Berryhill
Ashutosh Tewari
Publication date
01-02-2009
Publisher
Springer-Verlag
Published in
World Journal of Urology / Issue 1/2009
Print ISSN: 0724-4983
Electronic ISSN: 1433-8726
DOI
https://doi.org/10.1007/s00345-008-0325-5

Other articles of this Issue 1/2009

World Journal of Urology 1/2009 Go to the issue