Skip to main content
Top
Published in: European Radiology 5/2021

Open Access 01-05-2021 | Epilepsy | Neuro

Diagnostic accuracy for the epileptogenic zone detection in focal epilepsy could be higher in FDG-PET/MRI than in FDG-PET/CT

Authors: Kazufumi Kikuchi, Osamu Togao, Koji Yamashita, Daichi Momosaka, Tomohiro Nakayama, Yoshiyuki Kitamura, Yoshitomo Kikuchi, Shingo Baba, Koji Sagiyama, Keisuke Ishimatsu, Ryotaro Kamei, Nobutaka Mukae, Koji Iihara, Satoshi O. Suzuki, Toru Iwaki, Akio Hiwatashi

Published in: European Radiology | Issue 5/2021

Login to get access

Abstract

Objectives

To examine the utility of FDG-PET/MRI in patients with epilepsy by comparing the diagnostic accuracy of PET/MRI and PET/CT in epileptogenic zone (EZ) detection.

Methods

This prospective study included 31 patients (17 males, 14 females) who underwent surgical resection for EZ. All patients were first scanned using FDG-PET/CT followed immediately with FDG-PET/MRI. Two series of PET plus standalone MR images were interpreted independently by five board-certified radiologists. A 4-point visual score was used to assess image quality. Sensitivities and visual scores from both PETs and standalone MRI were compared using the McNemar test with Bonferroni correction and Dunn’s multiple comparisons test.

Results

The EZs were confirmed histopathologically via resection as hippocampal sclerosis (n = 11, 35.5%), gliosis (n = 8, 25.8%), focal cortical dysplasia (n = 6, 19.4%), and brain tumours (n = 6, 19.4%) including cavernous haemangioma (n = 3), dysembryoplastic neuroepithelial tumour (n = 1), ganglioglioma (n = 1), and polymorphous low-grade neuroepithelial tumour of the young (n = 1). The sensitivity of FDG-PET/MRI was significantly higher than that of FDG-PET/CT and standalone MRI (FDG-PET/MRI vs. FDG-PET/CT vs. standalone MRI; 77.4–90.3% vs. 58.1–64.5% vs. 45.2–80.6%, p < 0.0001, respectively). The visual scores derived from FDG-PET/MRI were significantly higher than those of FDG-PET/CT, as well as standalone MRI (2.8 ± 1.2 vs. 2.0 ± 1.1 vs. 2.1 ± 1.2, p < 0.0001, respectively). Compared to FDG-PET/CT, FDG-PET/MRI increased the visual score (51.9%, increased visual scores of 2 and 3).

Conclusions

The diagnostic accuracy for the EZ detection in focal epilepsy could be higher in FDG-PET/MRI than in FDG-PET/CT.

Key Points

• Sensitivity of FDG-PET/MRI was significantly higher than that of FDG-PET/CT and standalone MRI (FDG-PET/MRI vs. FDG-PET/CT vs. standalone MRI; 77.4–90.3% vs. 58.1–64.5% vs. 45.2–80.6%, p < 0.0001, respectively).
• Visual scores derived from FDG-PET/MRI were significantly higher than those of FDG-PET/CT and standalone MRI (2.8 ± 1.2 vs. 2.0 ± 1.1 vs. 2.1 ± 1.2, p < 0.0001, respectively).
Compared to FDG-PET/CT, FDG-PET/MRI increased the visual score (51.9%, increased visual scores of 2 and 3).
Appendix
Available only for authorised users
Literature
1.
go back to reference Hauser WA, Hesdorffer DC (1990) Epilepsy: frequency, causes and consequences. Demos Press, New York, pp 1–51 Hauser WA, Hesdorffer DC (1990) Epilepsy: frequency, causes and consequences. Demos Press, New York, pp 1–51
2.
go back to reference Kwan P, Brodie MJ (2000) Early identification of refractory epilepsy. N Engl J Med 342:314–319CrossRef Kwan P, Brodie MJ (2000) Early identification of refractory epilepsy. N Engl J Med 342:314–319CrossRef
3.
go back to reference Begley CE, Annegers JF, Lairson DR, Reynolds TF, Hauser WA (1994) Cost of epilepsy in the United States: a model based on incidence and prognosis. Epilepsia 35:1230–1243CrossRef Begley CE, Annegers JF, Lairson DR, Reynolds TF, Hauser WA (1994) Cost of epilepsy in the United States: a model based on incidence and prognosis. Epilepsia 35:1230–1243CrossRef
4.
go back to reference Engel J Jr, Wiebe S, French J et al (2003) Practice parameter: temporal lobe and localized neocortical resections for epilepsy: report of the quality standards Subcommittee of the American Academy of Neurology, in association with the American Epilepsy Society and the American Association of Neurological Surgeons. Neurology 60:538–547CrossRef Engel J Jr, Wiebe S, French J et al (2003) Practice parameter: temporal lobe and localized neocortical resections for epilepsy: report of the quality standards Subcommittee of the American Academy of Neurology, in association with the American Epilepsy Society and the American Association of Neurological Surgeons. Neurology 60:538–547CrossRef
5.
go back to reference Lee KK, Salamon N (2009) [18F] fluorodeoxyglucose-positron-emission tomography and MR imaging coregistration for presurgical evaluation of medically refractory epilepsy. AJNR Am J Neuroradiol 30:1811–1816CrossRef Lee KK, Salamon N (2009) [18F] fluorodeoxyglucose-positron-emission tomography and MR imaging coregistration for presurgical evaluation of medically refractory epilepsy. AJNR Am J Neuroradiol 30:1811–1816CrossRef
6.
go back to reference Shang K, Wang J, Fan X et al (2018) Clinical value of hybrid TOF-PET/MR imaging-based multiparametric imaging in localizing seizure focus in patients with MRI-negative temporal lobe epilepsy. AJNR Am J Neuroradiol 39:1791–1798CrossRef Shang K, Wang J, Fan X et al (2018) Clinical value of hybrid TOF-PET/MR imaging-based multiparametric imaging in localizing seizure focus in patients with MRI-negative temporal lobe epilepsy. AJNR Am J Neuroradiol 39:1791–1798CrossRef
7.
go back to reference Lehericy S, Semah F, Hasboun D et al (1997) Temporal lobe epilepsy with varying severity: MRI study of 222 patients. Neuroradiology 39:788–796CrossRef Lehericy S, Semah F, Hasboun D et al (1997) Temporal lobe epilepsy with varying severity: MRI study of 222 patients. Neuroradiology 39:788–796CrossRef
8.
go back to reference Jayalakshmi S, Nanda SK, Vooturi S et al (2019) Focal cortical dysplasia and refractory epilepsy: role of multimodality imaging and outcome of surgery. AJNR Am J Neuroradiol 40:892–898CrossRef Jayalakshmi S, Nanda SK, Vooturi S et al (2019) Focal cortical dysplasia and refractory epilepsy: role of multimodality imaging and outcome of surgery. AJNR Am J Neuroradiol 40:892–898CrossRef
9.
go back to reference Paldino MJ, Yang E, Jones JY et al (2017) Comparison of the diagnostic accuracy of PET/MRI to PET/CT-acquired FDG brain exams for seizure focus detection: a prospective study. Pediatr Radiol 47:1500–1507CrossRef Paldino MJ, Yang E, Jones JY et al (2017) Comparison of the diagnostic accuracy of PET/MRI to PET/CT-acquired FDG brain exams for seizure focus detection: a prospective study. Pediatr Radiol 47:1500–1507CrossRef
10.
go back to reference Sagiyama K, Watanabe Y, Kamei R et al (2017) Multiparametric voxel-based analyses of standardized uptake values and apparent diffusion coefficients of soft-tissue tumours with a positron emission tomography/magnetic resonance system: preliminary results. Eur Radiol 27:5024–5033CrossRef Sagiyama K, Watanabe Y, Kamei R et al (2017) Multiparametric voxel-based analyses of standardized uptake values and apparent diffusion coefficients of soft-tissue tumours with a positron emission tomography/magnetic resonance system: preliminary results. Eur Radiol 27:5024–5033CrossRef
11.
go back to reference Wieser HG, Blume WT, Fish D et al (2001) ILAE commission report. Proposal for a new classification of outcome with respect to epileptic seizures following epilepsy surgery. Epilepsia 42:282–286CrossRef Wieser HG, Blume WT, Fish D et al (2001) ILAE commission report. Proposal for a new classification of outcome with respect to epileptic seizures following epilepsy surgery. Epilepsia 42:282–286CrossRef
12.
go back to reference Aasheim LB, Karlberg A, Goa PE et al (2015) PET/MR brain imaging: evaluation of clinical UTE-based attenuation correction. Eur J Nucl Med Mol Imaging 42:1439–1446CrossRef Aasheim LB, Karlberg A, Goa PE et al (2015) PET/MR brain imaging: evaluation of clinical UTE-based attenuation correction. Eur J Nucl Med Mol Imaging 42:1439–1446CrossRef
13.
go back to reference Kikuchi K, Hiwatashi A, Togao O et al (2015) 3D MR sequence capable of simultaneous image acquisitions with and without blood vessel suppression: utility in diagnosing brain metastases. Eur Radiol 25:901–910CrossRef Kikuchi K, Hiwatashi A, Togao O et al (2015) 3D MR sequence capable of simultaneous image acquisitions with and without blood vessel suppression: utility in diagnosing brain metastases. Eur Radiol 25:901–910CrossRef
14.
go back to reference Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRef Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRef
15.
go back to reference Durnford AJ, Rodgers W, Kirkham FJ et al (2011) Very good inter-rater reliability of Engel and ILAE epilepsy surgery outcome classifications in a series of 76 patients. Seizure 20:809–812CrossRef Durnford AJ, Rodgers W, Kirkham FJ et al (2011) Very good inter-rater reliability of Engel and ILAE epilepsy surgery outcome classifications in a series of 76 patients. Seizure 20:809–812CrossRef
16.
go back to reference So EL, Ryvlin P (2015) MRI-negative epilepsy: evaluation and surgical management. Cambridge University Press, CambridgeCrossRef So EL, Ryvlin P (2015) MRI-negative epilepsy: evaluation and surgical management. Cambridge University Press, CambridgeCrossRef
17.
go back to reference Salamon N, Kung J, Shaw SJ et al (2008) FDG-PET/MRI coregistration improves detection of cortical dysplasia in patients with epilepsy. Neurology 71:1594–1601CrossRef Salamon N, Kung J, Shaw SJ et al (2008) FDG-PET/MRI coregistration improves detection of cortical dysplasia in patients with epilepsy. Neurology 71:1594–1601CrossRef
18.
go back to reference Mendes Coelho VC, Morita ME, Amorim BJ et al (2017) Automated online quantification method for (18)F-FDG positron emission tomography/CT improves detection of the epileptogenic zone in patients with pharmacoresistant epilepsy. Front Neurol 8:453CrossRef Mendes Coelho VC, Morita ME, Amorim BJ et al (2017) Automated online quantification method for (18)F-FDG positron emission tomography/CT improves detection of the epileptogenic zone in patients with pharmacoresistant epilepsy. Front Neurol 8:453CrossRef
19.
go back to reference Traub-Weidinger T, Muzik O, Sundar LKS et al (2020) Utility of absolute quantification in non-lesional extratemporal lobe epilepsy using FDG PET/MR imaging. Front Neurol 11:54CrossRef Traub-Weidinger T, Muzik O, Sundar LKS et al (2020) Utility of absolute quantification in non-lesional extratemporal lobe epilepsy using FDG PET/MR imaging. Front Neurol 11:54CrossRef
Metadata
Title
Diagnostic accuracy for the epileptogenic zone detection in focal epilepsy could be higher in FDG-PET/MRI than in FDG-PET/CT
Authors
Kazufumi Kikuchi
Osamu Togao
Koji Yamashita
Daichi Momosaka
Tomohiro Nakayama
Yoshiyuki Kitamura
Yoshitomo Kikuchi
Shingo Baba
Koji Sagiyama
Keisuke Ishimatsu
Ryotaro Kamei
Nobutaka Mukae
Koji Iihara
Satoshi O. Suzuki
Toru Iwaki
Akio Hiwatashi
Publication date
01-05-2021
Publisher
Springer Berlin Heidelberg
Keyword
Epilepsy
Published in
European Radiology / Issue 5/2021
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-020-07389-1

Other articles of this Issue 5/2021

European Radiology 5/2021 Go to the issue