Published in: European Radiology 11/2020

Open Access 01-11-2020 | Magnetic Resonance Imaging | Gastrointestinal

Magnetic resonance cholangiopancreatography with compressed sensing at 1.5 T: clinical application for the evaluation of branch duct IPMN of the pancreas

Authors: Benjamin Henninger, Michael Steurer, Michaela Plaikner, Elisabeth Weiland, Werner Jaschke, Christian Kremser

Published in: European Radiology | Issue 11/2020

Login to get access

Abstract

Objectives

To evaluate magnetic resonance cholangiopancreatography (MRCP) with compressed sensing (CS) for the assessment of branch duct intraductal papillary mucinous neoplasm (BD-IPMN) of the pancreas. For this purpose, conventional navigator-triggered (NT) sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE) MRCP was compared with various CS-SPACE-MRCP sequences in a clinical setting.

Methods

A total of 41 patients (14 male, 27 female, mean age 68 years) underwent 1.5-T MRCP for the evaluation of BD-IPMN. The MRCP protocol consisted of the following sequences: conventional NT-SPACE-MRCP, CS-SPACE-MRCP with long (BHL, 17 s) and short single breath-hold (BHS, 8 s), and NT-CS-SPACE-MRCP. Two board-certified radiologists evaluated image quality, duct sharpness, duct visualization, lesion conspicuity, confidence, and communication with the main pancreatic duct in consensus using a 5-point scale (1–5), with higher scores indicating better quality/delineation/confidence. Maximum intensity projection reconstructions and originally acquired data were used for evaluation. Wilcoxon signed-rank test was used to compare the intra-individual difference between sequences.

Results

BHS-CS-SPACE-MRCP had the highest scores for image quality (3.85 ± 0.79), duct sharpness (3.81 ± 1.05), and duct visualization (3.81 ± 1.01). There was a significant difference compared with NT-CS-SPACE-MRCP (p < 0.05) but no significant difference to the standard NT-SPACE-MRCP (p > 0.05). Concerning diagnostic quality, BHS-CS-SPACE-MRCP had the highest scores in lesion conspicuity (3.95 ± 0.92), confidence (4.12 ± 1.08), and communication (3.8 ± 1.06), significantly higher compared with NT-SPACE-MRCP, BHL-SPACE-MRCP, and NT-CS-SPACE-MRCP (p = <0.05).

Conclusions

MRCP with CS 3D SPACE for the evaluation of BD-IPMN at 1.5 T provides the best results using a short breath-hold sequence. This approach is feasible and an excellent alternative to standard NT 3D MRCP sequences.

Key Points

• 1.5-T MRCP with compressed sensing for the evaluation of branch duct IPMN is a feasible method.
• Short breath-hold sequences provide the best results for this purpose.
Literature
1.
go back to reference O’Neill E, Hammond N, Miller FH (2014) MR imaging of the pancreas. Radiol Clin North Am 52:757–777CrossRef O’Neill E, Hammond N, Miller FH (2014) MR imaging of the pancreas. Radiol Clin North Am 52:757–777CrossRef
2.
go back to reference Tanaka M, Fernandez-Del Castillo C, Kamisawa T et al (2017) Revisions of international consensus Fukuoka guidelines for the management of IPMN of the pancreas. Pancreatology 17:738–753CrossRef Tanaka M, Fernandez-Del Castillo C, Kamisawa T et al (2017) Revisions of international consensus Fukuoka guidelines for the management of IPMN of the pancreas. Pancreatology 17:738–753CrossRef
3.
go back to reference Anupindi SA, Victoria T (2008) Magnetic resonance cholangiopancreatography: techniques and applications. Magn Reson Imaging Clin N Am 16:453–466 v Anupindi SA, Victoria T (2008) Magnetic resonance cholangiopancreatography: techniques and applications. Magn Reson Imaging Clin N Am 16:453–466 v
4.
go back to reference Kim SH, Lee JM, Lee ES et al (2015) Intraductal papillary mucinous neoplasms of the pancreas: evaluation of malignant potential and surgical resectability by using MR imaging with MR cholangiography. Radiology 274:723–733CrossRef Kim SH, Lee JM, Lee ES et al (2015) Intraductal papillary mucinous neoplasms of the pancreas: evaluation of malignant potential and surgical resectability by using MR imaging with MR cholangiography. Radiology 274:723–733CrossRef
5.
go back to reference Sodickson A, Mortele KJ, Barish MA, Zou KH, Thibodeau S, Tempany CM (2006) Three-dimensional fast-recovery fast spin-echo MRCP: comparison with two-dimensional single-shot fast spin-echo techniques. Radiology 238:549–559CrossRef Sodickson A, Mortele KJ, Barish MA, Zou KH, Thibodeau S, Tempany CM (2006) Three-dimensional fast-recovery fast spin-echo MRCP: comparison with two-dimensional single-shot fast spin-echo techniques. Radiology 238:549–559CrossRef
6.
go back to reference Liu K, Xie P, Peng W, Zhou Z (2015) Magnetic resonance cholangiopancreatography: comparison of two- and three-dimensional sequences for the assessment of pancreatic cystic lesions. Oncol Lett 9:1917–1921CrossRef Liu K, Xie P, Peng W, Zhou Z (2015) Magnetic resonance cholangiopancreatography: comparison of two- and three-dimensional sequences for the assessment of pancreatic cystic lesions. Oncol Lett 9:1917–1921CrossRef
7.
go back to reference Megibow AJ, Baker ME, Morgan DE et al (2017) Management of incidental pancreatic cysts: a white paper of the ACR Incidental Findings Committee. J Am Coll Radiol 14:911–923CrossRef Megibow AJ, Baker ME, Morgan DE et al (2017) Management of incidental pancreatic cysts: a white paper of the ACR Incidental Findings Committee. J Am Coll Radiol 14:911–923CrossRef
8.
go back to reference Arizono S, Isoda H, Maetani YS et al (2008) High-spatial-resolution three-dimensional MR cholangiography using a high-sampling-efficiency technique (SPACE) at 3 T: comparison with the conventional constant flip angle sequence in healthy volunteers. J Magn Reson Imaging 28:685–690CrossRef Arizono S, Isoda H, Maetani YS et al (2008) High-spatial-resolution three-dimensional MR cholangiography using a high-sampling-efficiency technique (SPACE) at 3 T: comparison with the conventional constant flip angle sequence in healthy volunteers. J Magn Reson Imaging 28:685–690CrossRef
9.
go back to reference Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182–1195CrossRef Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182–1195CrossRef
10.
go back to reference Henninger B, Raithel E, Kranewitter C, Steurer M, Jaschke W, Kremser C (2018) Evaluation of an accelerated 3D SPACE sequence with compressed sensing and free-stop scan mode for imaging of the knee. Eur J Radiol 102:74–82CrossRef Henninger B, Raithel E, Kranewitter C, Steurer M, Jaschke W, Kremser C (2018) Evaluation of an accelerated 3D SPACE sequence with compressed sensing and free-stop scan mode for imaging of the knee. Eur J Radiol 102:74–82CrossRef
11.
go back to reference Vincenti G, Monney P, Chaptinel J et al (2014) Compressed sensing single-breath-hold CMR for fast quantification of LV function, volumes, and mass. JACC Cardiovasc Imaging 7:882–892CrossRef Vincenti G, Monney P, Chaptinel J et al (2014) Compressed sensing single-breath-hold CMR for fast quantification of LV function, volumes, and mass. JACC Cardiovasc Imaging 7:882–892CrossRef
12.
go back to reference Chandarana H, Doshi AM, Shanbhogue A et al (2016) Three-dimensional MR cholangiopancreatography in a breath hold with sparsity-based reconstruction of highly undersampled data. Radiology 280:585–594CrossRef Chandarana H, Doshi AM, Shanbhogue A et al (2016) Three-dimensional MR cholangiopancreatography in a breath hold with sparsity-based reconstruction of highly undersampled data. Radiology 280:585–594CrossRef
13.
go back to reference Seo N, Park MS, Han K et al (2017) Feasibility of 3D navigator-triggered magnetic resonance cholangiopancreatography with combined parallel imaging and compressed sensing reconstruction at 3 T. J Magn Reson Imaging 46:1289–1297CrossRef Seo N, Park MS, Han K et al (2017) Feasibility of 3D navigator-triggered magnetic resonance cholangiopancreatography with combined parallel imaging and compressed sensing reconstruction at 3 T. J Magn Reson Imaging 46:1289–1297CrossRef
14.
go back to reference Nagata S, Goshima S, Noda Y et al (2019) Magnetic resonance cholangiopancreatography using optimized integrated combination with parallel imaging and compressed sensing technique. Abdom Radiol (NY) 44:1766–1772CrossRef Nagata S, Goshima S, Noda Y et al (2019) Magnetic resonance cholangiopancreatography using optimized integrated combination with parallel imaging and compressed sensing technique. Abdom Radiol (NY) 44:1766–1772CrossRef
17.
go back to reference Yoon LS, Catalano OA, Fritz S, Ferrone CR, Hahn PF, Sahani DV (2009) Another dimension in magnetic resonance cholangiopancreatography: comparison of 2- and 3-dimensional magnetic resonance cholangiopancreatography for the evaluation of intraductal papillary mucinous neoplasm of the pancreas. J Comput Assist Tomogr 33:363–368CrossRef Yoon LS, Catalano OA, Fritz S, Ferrone CR, Hahn PF, Sahani DV (2009) Another dimension in magnetic resonance cholangiopancreatography: comparison of 2- and 3-dimensional magnetic resonance cholangiopancreatography for the evaluation of intraductal papillary mucinous neoplasm of the pancreas. J Comput Assist Tomogr 33:363–368CrossRef
18.
go back to reference Kwon H, Reid S, Kim D, Lee S, Cho J, Oh J (2018) Diagnosing common bile duct obstruction: comparison of image quality and diagnostic performance of three-dimensional magnetic resonance cholangiopancreatography with and without compressed sensing. Abdom Radiol (NY) 43:2255–2261CrossRef Kwon H, Reid S, Kim D, Lee S, Cho J, Oh J (2018) Diagnosing common bile duct obstruction: comparison of image quality and diagnostic performance of three-dimensional magnetic resonance cholangiopancreatography with and without compressed sensing. Abdom Radiol (NY) 43:2255–2261CrossRef
19.
go back to reference Furlan A, Bayram E, Thangasamy S, Barley D, Dasyam A (2018) Application of compressed sensing to 3D magnetic resonance cholangiopancreatography for the evaluation of pancreatic cystic lesions. Magn Reson Imaging 52:131–136CrossRef Furlan A, Bayram E, Thangasamy S, Barley D, Dasyam A (2018) Application of compressed sensing to 3D magnetic resonance cholangiopancreatography for the evaluation of pancreatic cystic lesions. Magn Reson Imaging 52:131–136CrossRef
20.
go back to reference Taron J, Weiss J, Notohamiprodjo M et al (2018) Acceleration of magnetic resonance cholangiopancreatography using compressed sensing at 1.5 and 3 T: a clinical feasibility study. Invest Radiol 53:681–688CrossRef Taron J, Weiss J, Notohamiprodjo M et al (2018) Acceleration of magnetic resonance cholangiopancreatography using compressed sensing at 1.5 and 3 T: a clinical feasibility study. Invest Radiol 53:681–688CrossRef
21.
go back to reference Zhu L, Wu X, Sun Z et al (2018) Compressed-sensing accelerated 3-dimensional magnetic resonance cholangiopancreatography: application in suspected pancreatic diseases. Invest Radiol 53:150–157CrossRef Zhu L, Wu X, Sun Z et al (2018) Compressed-sensing accelerated 3-dimensional magnetic resonance cholangiopancreatography: application in suspected pancreatic diseases. Invest Radiol 53:150–157CrossRef
22.
go back to reference Yoon JH, Lee SM, Kang HJ et al (2017) Clinical feasibility of 3-dimensional magnetic resonance cholangiopancreatography using compressed sensing: comparison of image quality and diagnostic performance. Invest Radiol 52:612–619CrossRef Yoon JH, Lee SM, Kang HJ et al (2017) Clinical feasibility of 3-dimensional magnetic resonance cholangiopancreatography using compressed sensing: comparison of image quality and diagnostic performance. Invest Radiol 52:612–619CrossRef
23.
go back to reference Zhu L, Xue H, Sun Z et al (2018) Modified breath-hold compressed-sensing 3D MR cholangiopancreatography with a small field-of-view and high resolution acquisition: clinical feasibility in biliary and pancreatic disorders. J Magn Reson Imaging 48:1389–1399CrossRef Zhu L, Xue H, Sun Z et al (2018) Modified breath-hold compressed-sensing 3D MR cholangiopancreatography with a small field-of-view and high resolution acquisition: clinical feasibility in biliary and pancreatic disorders. J Magn Reson Imaging 48:1389–1399CrossRef
24.
go back to reference Tokoro H, Yamada A, Suzuki T et al (2020) Usefulness of breath-hold compressed sensing accelerated three-dimensional magnetic resonance cholangiopancreatography (MRCP) added to respiratory-gating conventional MRCP. Eur J Radiol 122:108765CrossRef Tokoro H, Yamada A, Suzuki T et al (2020) Usefulness of breath-hold compressed sensing accelerated three-dimensional magnetic resonance cholangiopancreatography (MRCP) added to respiratory-gating conventional MRCP. Eur J Radiol 122:108765CrossRef
Metadata
Title
Magnetic resonance cholangiopancreatography with compressed sensing at 1.5 T: clinical application for the evaluation of branch duct IPMN of the pancreas
Authors
Benjamin Henninger
Michael Steurer
Michaela Plaikner
Elisabeth Weiland
Werner Jaschke
Christian Kremser
Publication date
01-11-2020
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 11/2020
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-020-06996-2

Other articles of this Issue 11/2020

European Radiology 11/2020 Go to the issue