Six DWI questions you always wanted to know but were afraid to ask: clinical relevance for breast diffusion MRI

Authors: Mami Iima, Savannah C. Partridge, Denis Le Bihan

Published in: European Radiology | Issue 5/2020

Login to get access

Abstract

Diffusion MRI (often called diffusion-weighted imaging or DWI) has enjoyed a tremendous growth since its introduction in the mid-1980s, especially to investigate neurological disorders and in oncology. At a time when standardization and quality control appear as critical as ever to support widespread utilization, our aim was to address common fundamental questions that arise regarding results obtained with DWI. We focus on six questions taking breast DWI as an example, as breast DWI is increasingly used in clinical practice, but most of our conclusions would apply to DWI in general. We show especially that noise can act in a pernicious way specific to DWI. Ignoring such noise effects could lead to incorrect data interpretations or conclusions, of which authors and readers may be genuinely unaware. While addressing these six questions, we give practical examples of how noise effects can be understood, corrected when possible, or taken to our advantage.
Key Points
• Ignoring noise effects in DWI could lead to incorrect data interpretations or conclusions, of which authors and readers may be genuinely unaware.
• In vivo apparent diffusion coefficient (ADC) decreases with b value, which must therefore be reported along with ADC.
• Synthesized DWI boosts contrast at the expense of accurate diffusion/microstructure characterization.
Literature
1.
go back to reference Le Bihan D, Breton E, Lallemand D, Grenier P, Cabanis E, Laval-Jeantet M (1986) MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology 161:401–407CrossRef Le Bihan D, Breton E, Lallemand D, Grenier P, Cabanis E, Laval-Jeantet M (1986) MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology 161:401–407CrossRef
2.
go back to reference Padhani AR, Liu G, Koh DM et al (2009) Diffusion-weighted magnetic resonance imaging as a cancer biomarker: consensus and recommendations. Neoplasia 11:102–125CrossRef Padhani AR, Liu G, Koh DM et al (2009) Diffusion-weighted magnetic resonance imaging as a cancer biomarker: consensus and recommendations. Neoplasia 11:102–125CrossRef
3.
go back to reference Taouli B, Beer AJ, Chenevert T et al (2016) Diffusion-weighted imaging outside the brain: consensus statement from an ISMRM-sponsored workshop. J Magn Reson Imaging 44:521–540CrossRef Taouli B, Beer AJ, Chenevert T et al (2016) Diffusion-weighted imaging outside the brain: consensus statement from an ISMRM-sponsored workshop. J Magn Reson Imaging 44:521–540CrossRef
5.
go back to reference Keenan KE, Biller JR, Delfino JG et al (2019) Recommendations towards standards for quantitative MRI (qMRI) and outstanding needs. J Magn Reson Imaging 49:e26–e39CrossRef Keenan KE, Biller JR, Delfino JG et al (2019) Recommendations towards standards for quantitative MRI (qMRI) and outstanding needs. J Magn Reson Imaging 49:e26–e39CrossRef
7.
go back to reference deSouza NM, Winfield JM, Waterton JC et al (2018) Implementing diffusion-weighted MRI for body imaging in prospective multicentre trials: current considerations and future perspectives. Eur Radiol 28:1118–1131CrossRef deSouza NM, Winfield JM, Waterton JC et al (2018) Implementing diffusion-weighted MRI for body imaging in prospective multicentre trials: current considerations and future perspectives. Eur Radiol 28:1118–1131CrossRef
8.
go back to reference Partridge SC, Nissan N, Rahbar H, Kitsch AE, Sigmund EE (2017) Diffusion-weighted breast MRI: clinical applications and emerging techniques. J Magn Reson Imaging 45:337–355CrossRef Partridge SC, Nissan N, Rahbar H, Kitsch AE, Sigmund EE (2017) Diffusion-weighted breast MRI: clinical applications and emerging techniques. J Magn Reson Imaging 45:337–355CrossRef
10.
go back to reference Denny M (2017) The fallacy of the average: on the ubiquity, utility and continuing novelty of Jensen's inequality. J Exp Biol 220:139–146CrossRef Denny M (2017) The fallacy of the average: on the ubiquity, utility and continuing novelty of Jensen's inequality. J Exp Biol 220:139–146CrossRef
11.
go back to reference Blackledge MD, Leach MO, Collins DJ, Koh D-M (2011) Computed diffusion-weighted MR imaging may improve tumor detection. Radiology 261:573–581CrossRef Blackledge MD, Leach MO, Collins DJ, Koh D-M (2011) Computed diffusion-weighted MR imaging may improve tumor detection. Radiology 261:573–581CrossRef
12.
go back to reference Baxter GC, Graves MJ, Gilbert FJ, Patterson AJ (2019) A meta-analysis of the diagnostic performance of diffusion MRI for breast lesion characterization. Radiology 291:632–641CrossRef Baxter GC, Graves MJ, Gilbert FJ, Patterson AJ (2019) A meta-analysis of the diagnostic performance of diffusion MRI for breast lesion characterization. Radiology 291:632–641CrossRef
13.
go back to reference Le Bihan D, Mangin JF, Poupon C et al (2001) Diffusion tensor imaging: concepts and applications. J Magn Reson Imaging 13:534–546 Le Bihan D, Mangin JF, Poupon C et al (2001) Diffusion tensor imaging: concepts and applications. J Magn Reson Imaging 13:534–546
14.
go back to reference Eyal E, Shapiro-Feinberg M, Furman-Haran E et al (2012) Parametric diffusion tensor imaging of the breast. Invest Radiol 47:284–291CrossRef Eyal E, Shapiro-Feinberg M, Furman-Haran E et al (2012) Parametric diffusion tensor imaging of the breast. Invest Radiol 47:284–291CrossRef
15.
go back to reference Does MD, Parsons EC, Gore JC (2003) Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain. Magn Reson Med 49:206–215CrossRef Does MD, Parsons EC, Gore JC (2003) Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain. Magn Reson Med 49:206–215CrossRef
16.
go back to reference Malyarenko D, Galbán CJ, Londy FJ et al (2013) Multi-system repeatability and reproducibility of apparent diffusion coefficient measurement using an ice-water phantom. J Magn Reson Imaging 37:1238–1246CrossRef Malyarenko D, Galbán CJ, Londy FJ et al (2013) Multi-system repeatability and reproducibility of apparent diffusion coefficient measurement using an ice-water phantom. J Magn Reson Imaging 37:1238–1246CrossRef
17.
go back to reference Barnes A, Alonzi R, Blackledge M et al (2018) UK quantitative WB-DWI technical workgroup: consensus meeting recommendations on optimisation, quality control, processing and analysis of quantitative whole-body diffusion-weighted imaging for cancer. Br J Radiol 91:20170577CrossRef Barnes A, Alonzi R, Blackledge M et al (2018) UK quantitative WB-DWI technical workgroup: consensus meeting recommendations on optimisation, quality control, processing and analysis of quantitative whole-body diffusion-weighted imaging for cancer. Br J Radiol 91:20170577CrossRef
Metadata
Title
Six DWI questions you always wanted to know but were afraid to ask: clinical relevance for breast diffusion MRI
Authors
Mami Iima
Savannah C. Partridge
Denis Le Bihan
Publication date
01-05-2020
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 5/2020
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-019-06648-0

Other articles of this Issue 5/2020

European Radiology 5/2020 Go to the issue