Abstract

Objective

To evaluate the frequency, outcome, and risk factors of intravenous contrast media (CM) extravasation during contrast-enhanced CT scans in a large population.

Methods

After institutional review board approval, 142,651 patients (72,976 males and 69,675 females; mean age, 59.9 ± 13.0 years) who underwent contrast-enhanced CT scans with intravenous CM between January 2015 and April 2017 were retrospectively included. The frequency of CM extravasations and their clinical outcomes were investigated. Risk factors of CM extravasation were evaluated using logistic regression with generalized estimating equation analyses. In addition, the frequency and risk factors of large-volume (≥100 ml) CM extravasation were also investigated.

Results

CM extravasation occurred in 0.23% (321/142,651) of patients, all of which were of mild degree and resolved without any sequelae through conservative management. Multivariate analysis revealed that female gender [odds ratio (OR) = 1.61; p < 0.001], 60 < age ≤ 70 years (OR = 1.71; p = 0.004) or age > 70 years (OR = 2.49; p < 0.001), patients in general wards (OR = 2.71; p < 0.001) or ICUs (OR = 4.76; p < 0.001), 9.4 < CM viscosity ≤ 10.0 (OR = 1.65; p = 0.015), 10.0 < CM viscosity ≤ 10.6 (OR = 1.60; p = 0.002), and CM viscosity > 16.0 (OR = 2.55, p < 0.001) were independent risk factors for CM extravasation.

Conclusion

CM extravasation during contrast-enhanced CT scans was uncommon with no substantial clinical consequences. Several risk factors that may have the potential to reduce the occurrence of CM extravasation were identified.

Key Points

The observed frequency of contrast media extravasation during contrast-enhanced CT scans was 0.23% (321/142,651).
Significant risk factors for contrast media extravasation were female gender, age older than 60 years, patients in general wards or ICUs, and the viscosity of contrast media greater than 9.4 mPa∙s.
The main preventive action for contrast media extravasation would be to lower the viscosity of contrast media.
Appendix
Available only for authorised users
Literature
1.
go back to reference Dykes TM, Bhargavan-Chatfield M, Dyer RB (2015) Intravenous contrast extravasation during CT: a national data registry and practice quality improvement initiative. J Am Coll Radiol 12:183–191CrossRef Dykes TM, Bhargavan-Chatfield M, Dyer RB (2015) Intravenous contrast extravasation during CT: a national data registry and practice quality improvement initiative. J Am Coll Radiol 12:183–191CrossRef
2.
go back to reference Cohan RH, Bullard AB, Ellis JH et al (1997) Local reactions after injection of iodinated contrast material: detection, management, and outcome. Acad Radiol 4:711–718CrossRef Cohan RH, Bullard AB, Ellis JH et al (1997) Local reactions after injection of iodinated contrast material: detection, management, and outcome. Acad Radiol 4:711–718CrossRef
3.
go back to reference Federle MP, Chang PJ, Confer S, Ozgun B (1998) Frequency and effects of extravasation of ionic and nonionic CT contrast media during rapid bolus injection. Radiology 206:637–640CrossRef Federle MP, Chang PJ, Confer S, Ozgun B (1998) Frequency and effects of extravasation of ionic and nonionic CT contrast media during rapid bolus injection. Radiology 206:637–640CrossRef
4.
go back to reference Jacobs JE, Birnbaum BA, Langlotz CP (1998) Contrast media reactions and extravasation: relationship to intravenous injection rates. Radiology 209:411–416CrossRef Jacobs JE, Birnbaum BA, Langlotz CP (1998) Contrast media reactions and extravasation: relationship to intravenous injection rates. Radiology 209:411–416CrossRef
5.
go back to reference Miles SG, Rasmussen JF, Litwiller T, Osik A (1990) Safe use of an intravenous power injector for CT: experience and protocol. Radiology 176:69–70CrossRef Miles SG, Rasmussen JF, Litwiller T, Osik A (1990) Safe use of an intravenous power injector for CT: experience and protocol. Radiology 176:69–70CrossRef
6.
go back to reference Wang CL, Cohan RH, Ellis JH, Adusumilli S, Dunnick NR (2007) Frequency, management, and outcome of extravasation of nonionic iodinated contrast medium in 69,657 intravenous injections. Radiology 243:80–87CrossRef Wang CL, Cohan RH, Ellis JH, Adusumilli S, Dunnick NR (2007) Frequency, management, and outcome of extravasation of nonionic iodinated contrast medium in 69,657 intravenous injections. Radiology 243:80–87CrossRef
7.
go back to reference Wienbeck S, Fischbach R, Kloska SP et al (2010) Prospective study of access site complications of automated contrast injection with peripheral venous access in MDCT. AJR Am J Roentgenol 195:825–829CrossRef Wienbeck S, Fischbach R, Kloska SP et al (2010) Prospective study of access site complications of automated contrast injection with peripheral venous access in MDCT. AJR Am J Roentgenol 195:825–829CrossRef
8.
go back to reference Cohan RH, Ellis JH, Garner WL (1996) Extravasation of radiographic contrast material: recognition, prevention, and treatment. Radiology 200:593–604CrossRef Cohan RH, Ellis JH, Garner WL (1996) Extravasation of radiographic contrast material: recognition, prevention, and treatment. Radiology 200:593–604CrossRef
9.
go back to reference Pond GD, Dorr RT, McAleese KA (1992) Skin ulceration from extravasation of low-osmolality contrast medium: a complication of automation. AJR Am J Roentgenol 158:915–916CrossRef Pond GD, Dorr RT, McAleese KA (1992) Skin ulceration from extravasation of low-osmolality contrast medium: a complication of automation. AJR Am J Roentgenol 158:915–916CrossRef
10.
go back to reference Benson LS, Sathy MJ, Port RB (1996) Forearm compartment syndrome due to automated injection of computed tomography contrast material. J Orthop Trauma 10:433–436CrossRef Benson LS, Sathy MJ, Port RB (1996) Forearm compartment syndrome due to automated injection of computed tomography contrast material. J Orthop Trauma 10:433–436CrossRef
11.
go back to reference Loth TS, Eversmann WW, Jr (1991) Extravasation injuries in the upper extremity. Clin Orthop Relat Res: 248–254 Loth TS, Eversmann WW, Jr (1991) Extravasation injuries in the upper extremity. Clin Orthop Relat Res: 248–254
12.
go back to reference Memolo M, Dyer R, Zagoria RJ (1993) Extravasation injury with nonionic contrast material. AJR Am J Roentgenol 160:203–204CrossRef Memolo M, Dyer R, Zagoria RJ (1993) Extravasation injury with nonionic contrast material. AJR Am J Roentgenol 160:203–204CrossRef
13.
go back to reference Sistrom CL, Gay SB, Peffley L (1991) Extravasation of iopamidol and iohexol during contrast-enhanced CT: report of 28 cases. Radiology 180:707–710CrossRef Sistrom CL, Gay SB, Peffley L (1991) Extravasation of iopamidol and iohexol during contrast-enhanced CT: report of 28 cases. Radiology 180:707–710CrossRef
14.
go back to reference Shaqdan K, Aran S, Thrall J, Abujudeh H (2014) Incidence of contrast medium extravasation for CT and MRI in a large academic medical centre: a report on 502,391 injections. Clin Radiol 69:1264–1272CrossRef Shaqdan K, Aran S, Thrall J, Abujudeh H (2014) Incidence of contrast medium extravasation for CT and MRI in a large academic medical centre: a report on 502,391 injections. Clin Radiol 69:1264–1272CrossRef
15.
go back to reference Davenport MS, Wang CL, Bashir MR, Neville AM, Paulson EK (2012) Rate of contrast material extravasations and allergic-like reactions: effect of extrinsic warming of low-osmolality iodinated CT contrast material to 37 degrees C. Radiology 262:475–484CrossRef Davenport MS, Wang CL, Bashir MR, Neville AM, Paulson EK (2012) Rate of contrast material extravasations and allergic-like reactions: effect of extrinsic warming of low-osmolality iodinated CT contrast material to 37 degrees C. Radiology 262:475–484CrossRef
16.
go back to reference Moreno CC, Pinho D, Nelson RC et al (2013) Lessons learned from 118,970 multidetector computed tomographic intravenous contrast material administrations: impact of catheter dwell time and gauge, catheter location, rate of contrast material administration, and patient age and sex on volume of extravasate. J Comput Assist Tomogr 37:286–288CrossRef Moreno CC, Pinho D, Nelson RC et al (2013) Lessons learned from 118,970 multidetector computed tomographic intravenous contrast material administrations: impact of catheter dwell time and gauge, catheter location, rate of contrast material administration, and patient age and sex on volume of extravasate. J Comput Assist Tomogr 37:286–288CrossRef
17.
go back to reference Evans CJ, Fowkes FG, Ruckley CV, Lee AJ (1999) Prevalence of varicose veins and chronic venous insufficiency in men and women in the general population: Edinburgh Vein Study. J Epidemiol Community Health 53:149–153CrossRef Evans CJ, Fowkes FG, Ruckley CV, Lee AJ (1999) Prevalence of varicose veins and chronic venous insufficiency in men and women in the general population: Edinburgh Vein Study. J Epidemiol Community Health 53:149–153CrossRef
18.
go back to reference Jakobsen JA (2014) Contrast media extravasation injury. In: Thomsen HS, Webb JAW (eds) Contrast media, medical radiology, diagnostic imaging, 3rd edn. Springer-Verlag, Berlin Jakobsen JA (2014) Contrast media extravasation injury. In: Thomsen HS, Webb JAW (eds) Contrast media, medical radiology, diagnostic imaging, 3rd edn. Springer-Verlag, Berlin
20.
go back to reference Bellin MF, Jakobsen JA, Tomassin I et al (2002) Contrast medium extravasation injury: guidelines for prevention and management. Eur Radiol 12:2807–2812CrossRef Bellin MF, Jakobsen JA, Tomassin I et al (2002) Contrast medium extravasation injury: guidelines for prevention and management. Eur Radiol 12:2807–2812CrossRef
21.
go back to reference Schaverien MV, Evison D, McCulley SJ (2008) Management of large volume CT contrast medium extravasation injury: technical refinement and literature review. J Plast Reconstr Aesthet Surg 61:562–565CrossRef Schaverien MV, Evison D, McCulley SJ (2008) Management of large volume CT contrast medium extravasation injury: technical refinement and literature review. J Plast Reconstr Aesthet Surg 61:562–565CrossRef
22.
go back to reference Cochran ST, Bomyea K, Kahn M (2002) Treatment of iodinated contrast material extravasation with hyaluronidase. Acad Radiol 9(Suppl 2):S544–S546CrossRef Cochran ST, Bomyea K, Kahn M (2002) Treatment of iodinated contrast material extravasation with hyaluronidase. Acad Radiol 9(Suppl 2):S544–S546CrossRef
23.
go back to reference Sakellarious S, Li W, Paul MC, Roditi G (2016) Role of contrast media viscosity in altering wall shear stress and relation to the risk of contrast extravasations. Med Eng Phys 38:1426–1433CrossRef Sakellarious S, Li W, Paul MC, Roditi G (2016) Role of contrast media viscosity in altering wall shear stress and relation to the risk of contrast extravasations. Med Eng Phys 38:1426–1433CrossRef
24.
go back to reference Schwab SA, Uder M, Anders K, Heinrich MC, Kuefner MA (2009) Peripheral intravenous power injection of iodinated contrast media through 22G and 20G cannulas: can high flow rates be achieved safely? A clinical feasibility study. RoFo 181:355–361CrossRef Schwab SA, Uder M, Anders K, Heinrich MC, Kuefner MA (2009) Peripheral intravenous power injection of iodinated contrast media through 22G and 20G cannulas: can high flow rates be achieved safely? A clinical feasibility study. RoFo 181:355–361CrossRef
Metadata
Title
Frequency, outcome, and risk factors of contrast media extravasation in 142,651 intravenous contrast-enhanced CT scans
Authors
Eui Jin Hwang
Cheong-Il Shin
Young Hun Choi
Chang Min Park
Publication date
01-12-2018
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 12/2018
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-018-5507-y

Other articles of this Issue 12/2018

European Radiology 12/2018 Go to the issue