Skip to main content
Top
Published in: European Radiology 6/2018

01-06-2018 | Magnetic Resonance

Dynamic non-invasive ASL perfusion imaging of a normal pancreas with secretin augmented MR imaging

Authors: Khoschy Schawkat, Michael Ith, Andreas Christe, Wolfgang Kühn, Yojena Chittazhathu, Lauren Bains, Val Murray Runge, Johannes T. Heverhagen

Published in: European Radiology | Issue 6/2018

Login to get access

Abstract

Objectives

To investigate prospectively the repeatability of pancreatic perfusion measurements using arterial spin labelling (ASL) and to determine the increase in perfusion due to secretin stimulation.

Material and methods

An (FAIR)-TrueFISP ASL sequence was applied to determine the perfusion of the pancreatic head in a 3T MRI scanner. Ten healthy volunteers (four men, six women: mean age 28.5 ± 4.6 years; age range 25–40 years) were investigated twice within 1 week. The inter-individual variability was calculated using the standard deviation. Intra-individual agreement between the first and second scan was estimated using the Pearson correlation coefficient. A paired Wilcoxon rank-sum test was used to compare perfusion at baseline (BL) and during secretin stimulation.

Results

The mean BL perfusion of the pancreatic head was 285 ± 96 mL/100 g/min with an intra-individual correlation coefficient of 0.67 (strong) for repeated measurements. Secretin stimulation led to a significant increase (by 81%) in perfusion of the pancreatic head to 486 ±156 mL/100 g/min (p=0.002) with an intra-individual correlation of 0.29 (weak). A return to BL values was observed after 239 ± 92 s with a moderate intra-individual correlation coefficient of 0.42 for repeat measurements.

Conclusion

Dynamic non-invasive ASL imaging of the pancreas permitted quantification of pancreatic perfusion in a clinically applicable setting.

Key Points

ASL imaging of the pancreas permitted quantification of pancreatic perfusion
Secretin stimulation led to a significant increase in pancreatic perfusion
The intra-individual correlation coefficient for baseline perfusion was strong for repeated measurements
Literature
1.
go back to reference Lewis JD (2000) Urgent endoscopy with endoscopic therapy for acute diverticular bleeding. Gastroenterology 118:978–980CrossRefPubMed Lewis JD (2000) Urgent endoscopy with endoscopic therapy for acute diverticular bleeding. Gastroenterology 118:978–980CrossRefPubMed
2.
go back to reference Delrue L, Blanckaert P, Mertens D, Van Meerbeeck S, Ceelen W, Duyck P (2012) Tissue perfusion in pathologies of the pancreas: assessment using 128-slice computed tomography. Abdom Imaging 37:595–601CrossRefPubMed Delrue L, Blanckaert P, Mertens D, Van Meerbeeck S, Ceelen W, Duyck P (2012) Tissue perfusion in pathologies of the pancreas: assessment using 128-slice computed tomography. Abdom Imaging 37:595–601CrossRefPubMed
3.
go back to reference Tian C, Xu X (2017) Multislice Spiral Perfusion Computed Tomography to Assess Pancreatic Vascularity in Mild Acute Pancreatitis. J Comput Assist Tomogr 41:284–288CrossRefPubMed Tian C, Xu X (2017) Multislice Spiral Perfusion Computed Tomography to Assess Pancreatic Vascularity in Mild Acute Pancreatitis. J Comput Assist Tomogr 41:284–288CrossRefPubMed
4.
go back to reference Ketwaroo G, Brown A, Young B et al (2013) Defining the accuracy of secretin pancreatic function testing in patients with suspected early chronic pancreatitis. Am J Gastroenterol 108:1360–1366CrossRefPubMedPubMedCentral Ketwaroo G, Brown A, Young B et al (2013) Defining the accuracy of secretin pancreatic function testing in patients with suspected early chronic pancreatitis. Am J Gastroenterol 108:1360–1366CrossRefPubMedPubMedCentral
5.
go back to reference Boninsegna E, Manfredi R, Negrelli R, Avesani G, Mehrabi S, Pozzi Mucelli R (2017) Pancreatic duct stenosis: Differential diagnosis between malignant and benign conditions at secretin-enhanced MRCP. Clin Imaging 41:137–143CrossRefPubMed Boninsegna E, Manfredi R, Negrelli R, Avesani G, Mehrabi S, Pozzi Mucelli R (2017) Pancreatic duct stenosis: Differential diagnosis between malignant and benign conditions at secretin-enhanced MRCP. Clin Imaging 41:137–143CrossRefPubMed
6.
go back to reference Schraml C, Schwenzer NF, Martirosian P, Claussen CD, Schick F (2008) Perfusion imaging of the pancreas using an arterial spin labeling technique. J Magn Reson Imaging 28:1459–1465CrossRefPubMed Schraml C, Schwenzer NF, Martirosian P, Claussen CD, Schick F (2008) Perfusion imaging of the pancreas using an arterial spin labeling technique. J Magn Reson Imaging 28:1459–1465CrossRefPubMed
7.
go back to reference Cox EF, Smith JK, Chowdhury AH, Lobo DN, Francis ST, Simpson J (2015) Temporal assessment of pancreatic blood flow and perfusion following secretin stimulation using noninvasive MRI. J Magn Reson Imaging 42:1233–1240CrossRefPubMed Cox EF, Smith JK, Chowdhury AH, Lobo DN, Francis ST, Simpson J (2015) Temporal assessment of pancreatic blood flow and perfusion following secretin stimulation using noninvasive MRI. J Magn Reson Imaging 42:1233–1240CrossRefPubMed
8.
go back to reference Bali MA, Metens T, Denolin V, De Maertelaer V, Deviere J, Matos C (2008) Pancreatic perfusion: noninvasive quantitative assessment with dynamic contrast-enhanced MR imaging without and with secretin stimulation in healthy volunteers--initial results. Radiology 247:115–121CrossRefPubMed Bali MA, Metens T, Denolin V, De Maertelaer V, Deviere J, Matos C (2008) Pancreatic perfusion: noninvasive quantitative assessment with dynamic contrast-enhanced MR imaging without and with secretin stimulation in healthy volunteers--initial results. Radiology 247:115–121CrossRefPubMed
9.
go back to reference Sofuni A, Iijima H, Moriyasu F et al (2005) Differential diagnosis of pancreatic tumors using ultrasound contrast imaging. J Gastroenterol 40:518–525CrossRefPubMed Sofuni A, Iijima H, Moriyasu F et al (2005) Differential diagnosis of pancreatic tumors using ultrasound contrast imaging. J Gastroenterol 40:518–525CrossRefPubMed
10.
go back to reference Bize PE, Platon A, Becker CD, Poletti PA (2006) Perfusion measurement in acute pancreatitis using dynamic perfusion MDCT. AJR Am J Roentgenol 186:114–118CrossRefPubMed Bize PE, Platon A, Becker CD, Poletti PA (2006) Perfusion measurement in acute pancreatitis using dynamic perfusion MDCT. AJR Am J Roentgenol 186:114–118CrossRefPubMed
11.
go back to reference Tajima Y, Matsuzaki S, Furui J, Isomoto I, Hayashi K, Kanematsu T (2004) Use of the time-signal intensity curve from dynamic magnetic resonance imaging to evaluate remnant pancreatic fibrosis after pancreaticojejunostomy in patients undergoing pancreaticoduodenectomy. Br J Surg 91:595–600CrossRefPubMed Tajima Y, Matsuzaki S, Furui J, Isomoto I, Hayashi K, Kanematsu T (2004) Use of the time-signal intensity curve from dynamic magnetic resonance imaging to evaluate remnant pancreatic fibrosis after pancreaticojejunostomy in patients undergoing pancreaticoduodenectomy. Br J Surg 91:595–600CrossRefPubMed
12.
go back to reference Coenegrachts K, Van Steenbergen W, De Keyzer F et al (2004) Dynamic contrast-enhanced MRI of the pancreas: initial results in healthy volunteers and patients with chronic pancreatitis. J Magn Reson Imaging 20:990–997CrossRefPubMed Coenegrachts K, Van Steenbergen W, De Keyzer F et al (2004) Dynamic contrast-enhanced MRI of the pancreas: initial results in healthy volunteers and patients with chronic pancreatitis. J Magn Reson Imaging 20:990–997CrossRefPubMed
13.
go back to reference Hirshberg B, Qiu M, Cali AM et al (2009) Pancreatic perfusion of healthy individuals and type 1 diabetic patients as assessed by magnetic resonance perfusion imaging. Diabetologia 52:1561–1565CrossRefPubMed Hirshberg B, Qiu M, Cali AM et al (2009) Pancreatic perfusion of healthy individuals and type 1 diabetic patients as assessed by magnetic resonance perfusion imaging. Diabetologia 52:1561–1565CrossRefPubMed
14.
go back to reference Gardener AG, Francis ST (2010) Multislice perfusion of the kidneys using parallel imaging: image acquisition and analysis strategies. Magn Reson Med 63:1627–1636CrossRefPubMed Gardener AG, Francis ST (2010) Multislice perfusion of the kidneys using parallel imaging: image acquisition and analysis strategies. Magn Reson Med 63:1627–1636CrossRefPubMed
15.
go back to reference Martirosian P, Klose U, Mader I, Schick F (2004) FAIR true-FISP perfusion imaging of the kidneys. Magn Reson Med 51:353–361CrossRefPubMed Martirosian P, Klose U, Mader I, Schick F (2004) FAIR true-FISP perfusion imaging of the kidneys. Magn Reson Med 51:353–361CrossRefPubMed
16.
go back to reference Boss A, Martirosian P, Graf H, Claussen CD, Schlemmer HP, Schick F (2005) High resolution MR perfusion imaging of the kidneys at 3 Tesla without administration of contrast media. RöFo 177:1625–1630PubMed Boss A, Martirosian P, Graf H, Claussen CD, Schlemmer HP, Schick F (2005) High resolution MR perfusion imaging of the kidneys at 3 Tesla without administration of contrast media. RöFo 177:1625–1630PubMed
17.
go back to reference Chowdhury AH, Humes DJ, Pritchard SE et al (2011) The effects of morphine-neostigmine and secretin provocation on pancreaticobiliary morphology in healthy subjects: a randomized, double-blind crossover study using serial MRCP. World J Surg 35:2102–2109CrossRefPubMed Chowdhury AH, Humes DJ, Pritchard SE et al (2011) The effects of morphine-neostigmine and secretin provocation on pancreaticobiliary morphology in healthy subjects: a randomized, double-blind crossover study using serial MRCP. World J Surg 35:2102–2109CrossRefPubMed
18.
go back to reference de Bazelaire CM, Duhamel GD, Rofsky NM, Alsop DC (2004) MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results. Radiology 230:652–659CrossRefPubMed de Bazelaire CM, Duhamel GD, Rofsky NM, Alsop DC (2004) MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results. Radiology 230:652–659CrossRefPubMed
19.
go back to reference Bjornerud A, Johansson LO, Briley-Saebo K, Ahlstrom HK (2002) Assessment of T1 and T2* effects in vivo and ex vivo using iron oxide nanoparticles in steady state--dependence on blood volume and water exchange. Magn Reson Med 47:461–471CrossRefPubMed Bjornerud A, Johansson LO, Briley-Saebo K, Ahlstrom HK (2002) Assessment of T1 and T2* effects in vivo and ex vivo using iron oxide nanoparticles in steady state--dependence on blood volume and water exchange. Magn Reson Med 47:461–471CrossRefPubMed
20.
go back to reference Tsushima Y, Kusano S (1998) Age-dependent decline in parenchymal perfusion in the normal human pancreas: measurement by dynamic computed tomography. Pancreas 17:148–152CrossRefPubMed Tsushima Y, Kusano S (1998) Age-dependent decline in parenchymal perfusion in the normal human pancreas: measurement by dynamic computed tomography. Pancreas 17:148–152CrossRefPubMed
21.
go back to reference Dreiling DA, Messer J (1978) The secretin story: a saga in clinical medicine and gastrointestinal physiology. Am J Gastroenterol 70:455–479PubMed Dreiling DA, Messer J (1978) The secretin story: a saga in clinical medicine and gastrointestinal physiology. Am J Gastroenterol 70:455–479PubMed
22.
go back to reference Miles KA, Hayball MP, Dixon AK (1995) Measurement of human pancreatic perfusion using dynamic computed tomography with perfusion imaging. Br J Radiol 68:471–475CrossRefPubMed Miles KA, Hayball MP, Dixon AK (1995) Measurement of human pancreatic perfusion using dynamic computed tomography with perfusion imaging. Br J Radiol 68:471–475CrossRefPubMed
23.
go back to reference Fukukura Y, Fujiyoshi F, Sasaki M, Nakajo M (2002) Pancreatic duct: morphologic evaluation with MR cholangiopancreatography after secretin stimulation. Radiology 222:674–680CrossRefPubMed Fukukura Y, Fujiyoshi F, Sasaki M, Nakajo M (2002) Pancreatic duct: morphologic evaluation with MR cholangiopancreatography after secretin stimulation. Radiology 222:674–680CrossRefPubMed
24.
go back to reference Bali MA, Metens T, Denolin V et al (2011) Tumoral and nontumoral pancreas: correlation between quantitative dynamic contrast-enhanced MR imaging and histopathologic parameters. Radiology 261:456–466CrossRefPubMed Bali MA, Metens T, Denolin V et al (2011) Tumoral and nontumoral pancreas: correlation between quantitative dynamic contrast-enhanced MR imaging and histopathologic parameters. Radiology 261:456–466CrossRefPubMed
25.
go back to reference Heverhagen JT, Wagner HJ, Ebel H, Levine AL, Klose KJ, Hellinger A (2004) Pancreatic transplants: noninvasive evaluation with secretin-augmented mr pancreatography and MR perfusion measurements--preliminary results. Radiology 233:273–280CrossRefPubMed Heverhagen JT, Wagner HJ, Ebel H, Levine AL, Klose KJ, Hellinger A (2004) Pancreatic transplants: noninvasive evaluation with secretin-augmented mr pancreatography and MR perfusion measurements--preliminary results. Radiology 233:273–280CrossRefPubMed
26.
go back to reference Marx C, Konig M, Luck R, Klempnauer J, Heuser L (2000) Perfusion parameters in MRI diagnosis of pancreas transplants. RöFo 172:38–42PubMed Marx C, Konig M, Luck R, Klempnauer J, Heuser L (2000) Perfusion parameters in MRI diagnosis of pancreas transplants. RöFo 172:38–42PubMed
29.
go back to reference Wang Y, Yan K, Fan Z, Sun L, Wu W, Yang W (2016) Contrast-Enhanced Ultrasonography of Pancreatic Carcinoma: Correlation with Pathologic Findings. Ultrasound Med Biol 42:891–898CrossRefPubMed Wang Y, Yan K, Fan Z, Sun L, Wu W, Yang W (2016) Contrast-Enhanced Ultrasonography of Pancreatic Carcinoma: Correlation with Pathologic Findings. Ultrasound Med Biol 42:891–898CrossRefPubMed
Metadata
Title
Dynamic non-invasive ASL perfusion imaging of a normal pancreas with secretin augmented MR imaging
Authors
Khoschy Schawkat
Michael Ith
Andreas Christe
Wolfgang Kühn
Yojena Chittazhathu
Lauren Bains
Val Murray Runge
Johannes T. Heverhagen
Publication date
01-06-2018
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 6/2018
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-017-5227-8

Other articles of this Issue 6/2018

European Radiology 6/2018 Go to the issue