Skip to main content
Top
Published in: European Radiology 11/2017

Open Access 01-11-2017 | Computed Tomography

The effect of four-phasic versus three-phasic contrast media injection protocols on extravasation rate in coronary CT angiography: a randomized controlled trial

Authors: Júlia Karády, Alexisz Panajotu, Márton Kolossváry, Bálint Szilveszter, Ádám L. Jermendy, Andrea Bartykowszki, Mihály Károlyi, Csilla Celeng, Béla Merkely, Pál Maurovich-Horvat

Published in: European Radiology | Issue 11/2017

Login to get access

Abstract

Objectives

Contrast media (CM) extravasation is a well-known complication of CT angiography (CTA). Our prospective randomized control study aimed to assess whether a four-phasic CM administration protocol reduces the risk of extravasation compared to the routinely used three-phasic protocol in coronary CTA.

Methods

Patients referred to coronary CTA due to suspected coronary artery disease were included in the study. All patients received 400 mg/ml iomeprol CM injected with dual-syringe automated injector. Patients were randomized into a three-phasic injection-protocol group, with a CM bolus of 85 ml followed by 40 ml of 75%:25% saline/CM mixture and 30 ml saline chaser bolus; and a four-phasic injection-protocol group, with a saline pacer bolus of 10 ml injected at a lower flow rate before the three-phasic protocol.

Results

2,445 consecutive patients were enrolled (mean age 60.6 ± 12.1 years; females 43.6%). Overall rate of extravasation was 0.9% (23/2,445): 1.4% (17/1,229) in the three-phasic group and 0.5% (6/1,216) in the four-phasic group (p = 0.034).

Conclusions

Four-phasic CM administration protocol is easy to implement in the clinical routine at no extra cost. The extravasation rate is reduced by 65% with the application of the four-phasic protocol compared to the three-phasic protocol in coronary CTA.

Key Points

• Four-phasic CM injection-protocol reduces extravasation rate by 65% compared to three-phasic.
• The saline pacer bolus substantially reduces the risk of CM extravasation.
• The implementation of four-phasic injection-protocol is at no cost.
Literature
1.
go back to reference Moreno CC, Pinho D, Nelson RC et al (2013) Lessons learned from 118,970 multidetector computed tomographic intravenous contrast material administrations: impact of catheter dwell time and gauge, catheter location, rate of contrast material administration, and patient age and sex on volume of extravasate. J Comput Assist Tomogr 37:286–288CrossRef Moreno CC, Pinho D, Nelson RC et al (2013) Lessons learned from 118,970 multidetector computed tomographic intravenous contrast material administrations: impact of catheter dwell time and gauge, catheter location, rate of contrast material administration, and patient age and sex on volume of extravasate. J Comput Assist Tomogr 37:286–288CrossRef
2.
go back to reference Cohan RH, Ellis JH, Garner WL (1996) Extravasation of radiographic contrast material: recognition, prevention, and treatment. Radiology 200:593–604CrossRef Cohan RH, Ellis JH, Garner WL (1996) Extravasation of radiographic contrast material: recognition, prevention, and treatment. Radiology 200:593–604CrossRef
3.
go back to reference Federle MP, Chang PJ, Confer S, Ozgun B (1998) Frequency and effects of extravasation of ionic and nonionic CT contrast media during rapid bolus injection. Radiology 206:637–640CrossRef Federle MP, Chang PJ, Confer S, Ozgun B (1998) Frequency and effects of extravasation of ionic and nonionic CT contrast media during rapid bolus injection. Radiology 206:637–640CrossRef
4.
go back to reference Wienbeck S, Fischbach R, Kloska SP et al (2010) Prospective study of access site complications of automated contrast injection with peripheral venous access in MDCT. AJR Am J Roentgenol 195:825–829CrossRef Wienbeck S, Fischbach R, Kloska SP et al (2010) Prospective study of access site complications of automated contrast injection with peripheral venous access in MDCT. AJR Am J Roentgenol 195:825–829CrossRef
5.
go back to reference Wang CL, Cohan RH, Ellis JH, Adusumilli S, Dunnick NR (2007) Frequency, management, and outcome of extravasation of nonionic iodinated contrast medium in 69,657 intravenous injections. Radiology 243:80–87CrossRef Wang CL, Cohan RH, Ellis JH, Adusumilli S, Dunnick NR (2007) Frequency, management, and outcome of extravasation of nonionic iodinated contrast medium in 69,657 intravenous injections. Radiology 243:80–87CrossRef
6.
go back to reference Shuman WP, Adam JL, Schoenecker SA, Tazioli PR, Moss AA (1986) Use of a power injector during dynamic computed tomography. J Comput Assist Tomogr 10:1000–1002CrossRef Shuman WP, Adam JL, Schoenecker SA, Tazioli PR, Moss AA (1986) Use of a power injector during dynamic computed tomography. J Comput Assist Tomogr 10:1000–1002CrossRef
7.
go back to reference Behrendt FF, Bruners P, Keil S et al (2009) Impact of different vein catheter sizes for mechanical power injection in CT: in vitro evaluation with use of a circulation phantom. Cardiovasc Intervent Radiol 32:25–31CrossRef Behrendt FF, Bruners P, Keil S et al (2009) Impact of different vein catheter sizes for mechanical power injection in CT: in vitro evaluation with use of a circulation phantom. Cardiovasc Intervent Radiol 32:25–31CrossRef
8.
go back to reference Cademartiri F, de Monye C, Pugliese F et al (2006) High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400. Invest Radiol 41:349–353CrossRef Cademartiri F, de Monye C, Pugliese F et al (2006) High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400. Invest Radiol 41:349–353CrossRef
9.
go back to reference Dykes TM, Bhargavan-Chatfield M, Dyer RB (2015) Intravenous contrast extravasation during CT: a national data registry and practice quality improvement initiative. J Am Coll Radiol 12:183–191CrossRef Dykes TM, Bhargavan-Chatfield M, Dyer RB (2015) Intravenous contrast extravasation during CT: a national data registry and practice quality improvement initiative. J Am Coll Radiol 12:183–191CrossRef
10.
go back to reference Wilson BG (2011) Contrast media-induced compartment syndrome. Radiol Technol 83:63–77PubMed Wilson BG (2011) Contrast media-induced compartment syndrome. Radiol Technol 83:63–77PubMed
11.
go back to reference Shaqdan K, Aran S, Thrall J, Abujudeh H (2014) Incidence of contrast medium extravasation for CT and MRI in a large academic medical centre: a report on 502,391 injections. Clin Radiol 69:1264–1272CrossRef Shaqdan K, Aran S, Thrall J, Abujudeh H (2014) Incidence of contrast medium extravasation for CT and MRI in a large academic medical centre: a report on 502,391 injections. Clin Radiol 69:1264–1272CrossRef
12.
go back to reference Bellin MF, Jakobsen JA, Tomassin I et al (2002) Contrast medium extravasation injury: guidelines for prevention and management. Eur Radiol 12:2807–2812CrossRef Bellin MF, Jakobsen JA, Tomassin I et al (2002) Contrast medium extravasation injury: guidelines for prevention and management. Eur Radiol 12:2807–2812CrossRef
13.
go back to reference Litmanovich D, Zamboni GA, Hauser TH, Lin PJ, Clouse ME, Raptopoulos V (2008) ECG-gated chest CT angiography with 64-MDCT and tri-phasic IV contrast administration regimen in patients with acute non-specific chest pain. Eur Radiol 18:308–317CrossRef Litmanovich D, Zamboni GA, Hauser TH, Lin PJ, Clouse ME, Raptopoulos V (2008) ECG-gated chest CT angiography with 64-MDCT and tri-phasic IV contrast administration regimen in patients with acute non-specific chest pain. Eur Radiol 18:308–317CrossRef
14.
go back to reference Lu JG, Lv B, Chen XB, Tang X, Jiang SL, Dai RP (2010) What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography? Eur J Radiol 75:159–165CrossRef Lu JG, Lv B, Chen XB, Tang X, Jiang SL, Dai RP (2010) What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography? Eur J Radiol 75:159–165CrossRef
15.
go back to reference Davenport MS, Wang CL, Bashir MR, Neville AM, Paulson EK (2012) Rate of contrast material extravasations and allergic-like reactions: effect of extrinsic warming of low-osmolality iodinated CT contrast material to 37 degrees C. Radiology 262:475–484CrossRef Davenport MS, Wang CL, Bashir MR, Neville AM, Paulson EK (2012) Rate of contrast material extravasations and allergic-like reactions: effect of extrinsic warming of low-osmolality iodinated CT contrast material to 37 degrees C. Radiology 262:475–484CrossRef
16.
go back to reference Kim R, Park EA, Lee W, Chung JW (2016) Feasibility of 320-row area detector CT coronary angiography using 40 ml of contrast material: assessment of image quality and diagnostic accuracy. Eur Radiol 26:3802–3810CrossRef Kim R, Park EA, Lee W, Chung JW (2016) Feasibility of 320-row area detector CT coronary angiography using 40 ml of contrast material: assessment of image quality and diagnostic accuracy. Eur Radiol 26:3802–3810CrossRef
17.
18.
go back to reference Mangold S, Wichmann JL, Schoepf UJ et al (2016) Coronary CT angiography in obese patients using 3(rd) generation dual-source CT: effect of body mass index on image quality. Eur Radiol 26:2937–2946CrossRef Mangold S, Wichmann JL, Schoepf UJ et al (2016) Coronary CT angiography in obese patients using 3(rd) generation dual-source CT: effect of body mass index on image quality. Eur Radiol 26:2937–2946CrossRef
Metadata
Title
The effect of four-phasic versus three-phasic contrast media injection protocols on extravasation rate in coronary CT angiography: a randomized controlled trial
Authors
Júlia Karády
Alexisz Panajotu
Márton Kolossváry
Bálint Szilveszter
Ádám L. Jermendy
Andrea Bartykowszki
Mihály Károlyi
Csilla Celeng
Béla Merkely
Pál Maurovich-Horvat
Publication date
01-11-2017
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 11/2017
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-017-4866-0

Other articles of this Issue 11/2017

European Radiology 11/2017 Go to the issue