Skip to main content
Top
Published in: European Radiology 7/2017

01-07-2017 | Vascular-Interventional

Tip malposition of peripherally inserted central catheters: a prospective randomized controlled trial to compare bedside insertion to fluoroscopically guided placement

Authors: Frédéric Glauser, Stephane Breault, Fabio Rigamonti, Charalampos Sotiriadis, Anne-Marie Jouannic, Salah D. Qanadli

Published in: European Radiology | Issue 7/2017

Login to get access

Abstract

Objective

Peripherally inserted central catheter (PICC) use continues to increase, leading to the development of a blind bedside technique (BST) for placement. The aim of our study was to compare the BST with the fluoroscopically guided technique (FGT), with specific regard to catheter tip position (CTP).

Materials and methods

One hundred eighty patients were randomized to either the BST or the FGT. All procedures were done by the same interventional team and included postprocedural chest X-ray to assess CTP. Depending on the international guidelines for optimal CTP, patients were classified in three types: optimal, suboptimal not needing repositioning, and nonoptimal requiring additional repositioning procedures. Fisher’s test was used for comparisons.

Results

One hundred seventy-one PICCs were successful inserted. In the BST groups, 23.3% of placements were suboptimal and 30% nonoptimal, requiring repositioning. In the FGT group, 5.6% were suboptimal and 1.1% nonoptimal. Thus, suboptimal and nonoptimal CTP were significantly lower in the FGT group (p < 0.001).

Conclusion

Tip malposition rates are high when using blind BST, exposing the patient to an increased risk of deep venous thrombosis and catheter malfunction. Using the FGT or emerging technologies that could help tip positioning are recommended, especially for long-term indications.

Key points

Bedside and fluoroscopy guided techniques are commonly used for PICC placement.
Catheter malposition is the major technical issue with the bedside technique.
Catheter malposition occurred in 53% of patients with the bedside technique.
Literature
1.
go back to reference Amerasekera SS, Jones CM, Patel R, Cleasby MJ (2009) Imaging of the complications of peripherally inserted central venous catheters. Clin Radiol 64:832–840CrossRefPubMed Amerasekera SS, Jones CM, Patel R, Cleasby MJ (2009) Imaging of the complications of peripherally inserted central venous catheters. Clin Radiol 64:832–840CrossRefPubMed
2.
go back to reference Maki DG, Kluger DM, Crnich CJ (2006) The risk of bloodstream infection in adults with different intravascular devices: a systematic review of 200 published prospective studies. Mayo Clin Proc 81:1159–1171CrossRefPubMed Maki DG, Kluger DM, Crnich CJ (2006) The risk of bloodstream infection in adults with different intravascular devices: a systematic review of 200 published prospective studies. Mayo Clin Proc 81:1159–1171CrossRefPubMed
3.
go back to reference Caers J, Fontaine C, Vinh-Hung V et al (2005) Catheter tip position as a risk factor for thrombosis associated with the use of subcutaneous infusion ports. Support Care Cancer 13:325–331CrossRefPubMed Caers J, Fontaine C, Vinh-Hung V et al (2005) Catheter tip position as a risk factor for thrombosis associated with the use of subcutaneous infusion ports. Support Care Cancer 13:325–331CrossRefPubMed
4.
go back to reference Verdino RJ (2006) The evolution of atrial fibrillation ablation from triggers to substrate. J Electrocardiol 39:S184–S187CrossRefPubMed Verdino RJ (2006) The evolution of atrial fibrillation ablation from triggers to substrate. J Electrocardiol 39:S184–S187CrossRefPubMed
5.
go back to reference Bivins MH, Callahan MJ (2000) Position-dependent ventricular tachycardia related to a peripherally inserted central catheter. Mayo Clin Proc 75:414–416CrossRefPubMed Bivins MH, Callahan MJ (2000) Position-dependent ventricular tachycardia related to a peripherally inserted central catheter. Mayo Clin Proc 75:414–416CrossRefPubMed
6.
go back to reference Orme RM, McSwiney MM, Chamberlain-Webber RF (2007) Fatal cardiac tamponade as a result of a peripherally inserted central venous catheter: a case report and review of the literature. Br J Anaesth 99:384–388CrossRefPubMed Orme RM, McSwiney MM, Chamberlain-Webber RF (2007) Fatal cardiac tamponade as a result of a peripherally inserted central venous catheter: a case report and review of the literature. Br J Anaesth 99:384–388CrossRefPubMed
7.
go back to reference Johnston AJ, Holder A, Bishop SM, See TC, Streater CT (2014) Evaluation of the Sherlock 3CG Tip Confirmation System on peripherally inserted central catheter malposition rates. Anaesthesia 69:1322–1330CrossRefPubMed Johnston AJ, Holder A, Bishop SM, See TC, Streater CT (2014) Evaluation of the Sherlock 3CG Tip Confirmation System on peripherally inserted central catheter malposition rates. Anaesthesia 69:1322–1330CrossRefPubMed
8.
go back to reference Baldinelli F, Capozzoli G, Pedrazzoli R, Marzano N (2015) Evaluation of the correct position of peripherally inserted central catheters: anatomical landmark vs. electrocardiographic technique. J Vasc Access 0:0 Baldinelli F, Capozzoli G, Pedrazzoli R, Marzano N (2015) Evaluation of the correct position of peripherally inserted central catheters: anatomical landmark vs. electrocardiographic technique. J Vasc Access 0:0
9.
go back to reference Ragasa J, Shah N, Watson RC (1989) Where antecubital catheters go: a study under fluoroscopic control. Anesthesiology 71:378–380CrossRefPubMed Ragasa J, Shah N, Watson RC (1989) Where antecubital catheters go: a study under fluoroscopic control. Anesthesiology 71:378–380CrossRefPubMed
10.
go back to reference LaRue GD (1995) Improving central placement rates of peripherally inserted catheters. J Intraven Nurs 18:24–27PubMed LaRue GD (1995) Improving central placement rates of peripherally inserted catheters. J Intraven Nurs 18:24–27PubMed
11.
go back to reference Burgess GE 3rd, Marino RJ, Peuler MJ (1977) Effect of head position on the location of venous catheters inserted via basilic veins. Anesthesiology 46:212–213CrossRefPubMed Burgess GE 3rd, Marino RJ, Peuler MJ (1977) Effect of head position on the location of venous catheters inserted via basilic veins. Anesthesiology 46:212–213CrossRefPubMed
12.
go back to reference Schweickert WD, Herlitz J, Pohlman AS, Gehlbach BK, Hall JB, Kress JP (2009) A randomized, controlled trial evaluating postinsertion neck ultrasound in peripherally inserted central catheter procedures. Crit Care Med 37:1217–1221CrossRefPubMed Schweickert WD, Herlitz J, Pohlman AS, Gehlbach BK, Hall JB, Kress JP (2009) A randomized, controlled trial evaluating postinsertion neck ultrasound in peripherally inserted central catheter procedures. Crit Care Med 37:1217–1221CrossRefPubMed
13.
go back to reference Pittiruti M, Hamilton H, Biffi R, MacFie J, Pertkiewicz M (2009) ESPEN Guidelines on Parenteral Nutrition: central venous catheters (access, care, diagnosis and therapy of complications). Clin Nutr 28:365–377CrossRefPubMed Pittiruti M, Hamilton H, Biffi R, MacFie J, Pertkiewicz M (2009) ESPEN Guidelines on Parenteral Nutrition: central venous catheters (access, care, diagnosis and therapy of complications). Clin Nutr 28:365–377CrossRefPubMed
14.
go back to reference Vesely TM (2003) Central venous catheter tip position: a continuing controversy. J Vasc Interv Radiol 14:527–534CrossRefPubMed Vesely TM (2003) Central venous catheter tip position: a continuing controversy. J Vasc Interv Radiol 14:527–534CrossRefPubMed
15.
go back to reference Ridge CA, Litmanovich D, Molinari F, Bankier AA, Eisenberg RL (2013) Radiographic evaluation of central venous catheter position: anatomic correlation using gated coronary computed tomographic angiography. J Thorac Imaging 28:129–133CrossRefPubMed Ridge CA, Litmanovich D, Molinari F, Bankier AA, Eisenberg RL (2013) Radiographic evaluation of central venous catheter position: anatomic correlation using gated coronary computed tomographic angiography. J Thorac Imaging 28:129–133CrossRefPubMed
16.
go back to reference Fricke BL, Racadio JM, Duckworth T, Donnelly LF, Tamer RM, Johnson ND (2005) Placement of peripherally inserted central catheters without fluoroscopy in children: initial catheter tip position. Radiology 234:887–892CrossRefPubMed Fricke BL, Racadio JM, Duckworth T, Donnelly LF, Tamer RM, Johnson ND (2005) Placement of peripherally inserted central catheters without fluoroscopy in children: initial catheter tip position. Radiology 234:887–892CrossRefPubMed
17.
go back to reference Trerotola SO, Thompson S, Chittams J, Vierregger KS (2007) Analysis of tip malposition and correction in peripherally inserted central catheters placed at bedside by a dedicated nursing team. J Vasc Interv Radiol 18:513–518CrossRefPubMed Trerotola SO, Thompson S, Chittams J, Vierregger KS (2007) Analysis of tip malposition and correction in peripherally inserted central catheters placed at bedside by a dedicated nursing team. J Vasc Interv Radiol 18:513–518CrossRefPubMed
18.
go back to reference Minkovich L, Djaiani G, McCluskey SA, Mitsakakis N, Gilbert RW, Beattie WS (2011) Frequent malpositions of peripherally inserted central venous catheters in patients undergoing head and neck surgery. Can J Anaesth 58:709–713CrossRefPubMed Minkovich L, Djaiani G, McCluskey SA, Mitsakakis N, Gilbert RW, Beattie WS (2011) Frequent malpositions of peripherally inserted central venous catheters in patients undergoing head and neck surgery. Can J Anaesth 58:709–713CrossRefPubMed
19.
go back to reference Johnston AJ, Bishop SM, Martin L, See TC, Streater CT (2013) Defining peripherally inserted central catheter tip position and an evaluation of insertions in one unit. Anaesthesia 68:484–491CrossRefPubMed Johnston AJ, Bishop SM, Martin L, See TC, Streater CT (2013) Defining peripherally inserted central catheter tip position and an evaluation of insertions in one unit. Anaesthesia 68:484–491CrossRefPubMed
20.
go back to reference Pittiruti M, Bertollo D, Briglia E et al (2012) The intracavitary ECG method for positioning the tip of central venous catheters: results of an Italian multicenter study. J Vasc Access 13:357–365CrossRefPubMed Pittiruti M, Bertollo D, Briglia E et al (2012) The intracavitary ECG method for positioning the tip of central venous catheters: results of an Italian multicenter study. J Vasc Access 13:357–365CrossRefPubMed
21.
go back to reference Venkatesan T, Sen N, Korula PJ et al (2007) Blind placements of peripherally inserted antecubital central catheters: initial catheter tip position in relation to carina. Br J Anaesth 98:83–88CrossRefPubMed Venkatesan T, Sen N, Korula PJ et al (2007) Blind placements of peripherally inserted antecubital central catheters: initial catheter tip position in relation to carina. Br J Anaesth 98:83–88CrossRefPubMed
22.
go back to reference Ng PK, Ault MJ, Maldonado LS (1996) Peripherally inserted central catheters in the intensive care unit. J Intensive Care Med 11:49–54CrossRefPubMed Ng PK, Ault MJ, Maldonado LS (1996) Peripherally inserted central catheters in the intensive care unit. J Intensive Care Med 11:49–54CrossRefPubMed
23.
go back to reference Pinsky MR (1990) The effects of mechanical ventilation on the cardiovascular system. Crit Care Clin 6:663–678PubMed Pinsky MR (1990) The effects of mechanical ventilation on the cardiovascular system. Crit Care Clin 6:663–678PubMed
24.
go back to reference (2006) Infusion Nursing Standards of Practice. J Infus Nurs 29:S1–92 (2006) Infusion Nursing Standards of Practice. J Infus Nurs 29:S1–92
25.
go back to reference Tian G, Chen B, Qi L, Zhu Y (2011) Modified insertion of a peripherally inserted central catheter: taking the chest radiograph earlier. Crit Care Nurse 31:64–69CrossRefPubMed Tian G, Chen B, Qi L, Zhu Y (2011) Modified insertion of a peripherally inserted central catheter: taking the chest radiograph earlier. Crit Care Nurse 31:64–69CrossRefPubMed
26.
go back to reference Funaki B (2002) Central venous access: a primer for the diagnostic radiologist. AJR Am J Roentgenol 179:309–318CrossRefPubMed Funaki B (2002) Central venous access: a primer for the diagnostic radiologist. AJR Am J Roentgenol 179:309–318CrossRefPubMed
Metadata
Title
Tip malposition of peripherally inserted central catheters: a prospective randomized controlled trial to compare bedside insertion to fluoroscopically guided placement
Authors
Frédéric Glauser
Stephane Breault
Fabio Rigamonti
Charalampos Sotiriadis
Anne-Marie Jouannic
Salah D. Qanadli
Publication date
01-07-2017
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 7/2017
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-016-4666-y

Other articles of this Issue 7/2017

European Radiology 7/2017 Go to the issue