Skip to main content
Top
Published in: European Radiology 2/2015

01-02-2015 | Interventional

Image-guided microwave thermoablation of hepatic tumours using novel robotic guidance: an early experience

Authors: Emmanuel C. Mbalisike, Thomas J. Vogl, Stefan Zangos, Katrin Eichler, Prakash Balakrishnan, Jijo Paul

Published in: European Radiology | Issue 2/2015

Login to get access

Abstract

Objective

To evaluate and compare novel robotic guidance and manual approaches based on procedural accuracy, procedural time, procedural performance, image quality as well as patient dose during image-guided microwave thermoablation.

Method

The study was prospectively performed between June 2013 and December 2013 using 70 patients. Forty randomly selected patients (group 1) were treated with manual guidance and 30 patients (group 2) were treated using a novel robotic guidance. Parameters evaluated were procedural accuracy, total procedural time, procedural performance, quantitative/qualitative image quality and patient dose. Two-sided Student’s t test and Wilcoxon rank-sum test were used to test the significance of the data and p values less than 0.05 were considered statistically significant.

Result

Accuracy parameters were significantly higher in group 2 (all p < 0.05). Total procedural time showed a mean time difference of 3 min (group 2 > group 1; p = 0.0008). Volume CT dose index and dose–length product were significantly lower for group 2 compared to group 1 (all p < 0.05) for CT fluoroscopy imaging. Total procedural performance score was higher for group 2 compared to group 1 (p = 0.0001). Image quality parameters were insignificant between examined groups.

Conclusion

The novel robotic guided approach improved the accuracy of targeting the target tumour, reduced patient dose and increased procedural performance (which influences the procedural safety) during ablation.

Key Points

Few reports are available in the literature regarding robotic-assisted liver microwave ablation.
The robotic guided approach improved accuracy of localizing the target tumour.
Radiation dose on patients was reduced with the robotic guidance.
Numbers of insertions and readjustments were reduced, lowering chances of complications.
Literature
2.
go back to reference Vogl TJ, Naguib NNN, Gruber-Rouh T, Koitka K, Lehnert T, Nour-Eldin NE (2011) Microwave ablation therapy: clinical utility in treatment of pulmonary metastases. Radiology 261:643–651PubMedCrossRef Vogl TJ, Naguib NNN, Gruber-Rouh T, Koitka K, Lehnert T, Nour-Eldin NE (2011) Microwave ablation therapy: clinical utility in treatment of pulmonary metastases. Radiology 261:643–651PubMedCrossRef
3.
go back to reference Ma X, Arellano RS, Gervais DA, Hahn PF, Mueller PR, Sahani DV (2010) Success of image-guided biopsy for small (<3 cm) focal liver lesions in cirrhotic and non-cirrhotic individuals. J Vasc Interv Radiol 21:1539–1547PubMedCrossRef Ma X, Arellano RS, Gervais DA, Hahn PF, Mueller PR, Sahani DV (2010) Success of image-guided biopsy for small (<3 cm) focal liver lesions in cirrhotic and non-cirrhotic individuals. J Vasc Interv Radiol 21:1539–1547PubMedCrossRef
4.
go back to reference Yu SC, Liew CT, Lau WY, Leung TW, Metreweli C (2001) US-guided percutaneous biopsy of small (<1-cm) hepatic lesions. Radiology 218:195–199PubMedCrossRef Yu SC, Liew CT, Lau WY, Leung TW, Metreweli C (2001) US-guided percutaneous biopsy of small (<1-cm) hepatic lesions. Radiology 218:195–199PubMedCrossRef
5.
go back to reference Nour-Eldin NE, Naguib NN, Mack M, Abskharon JE, Vogl TJ (2011) Pulmonary hemorrhage complicating radiofrequency ablation, from mild hemoptysis to life threatening pattern. Eur Radiol 21(1):197–204PubMedCrossRef Nour-Eldin NE, Naguib NN, Mack M, Abskharon JE, Vogl TJ (2011) Pulmonary hemorrhage complicating radiofrequency ablation, from mild hemoptysis to life threatening pattern. Eur Radiol 21(1):197–204PubMedCrossRef
6.
go back to reference Ding J, Jing X, Liu J et al (2013) Complications of thermal ablation of hepatic tumours: comparison of radiofrequency and microwave ablative techniques. Clin Radiol 68(6):608–615PubMedCrossRef Ding J, Jing X, Liu J et al (2013) Complications of thermal ablation of hepatic tumours: comparison of radiofrequency and microwave ablative techniques. Clin Radiol 68(6):608–615PubMedCrossRef
7.
go back to reference Kloeckner R, dos Santos DP, Schneider J, Kara L, Dueber C, Pitton MB (2013) Radiation exposure in CT-guided interventions. Eur J Radiol 82(12):2253–2257PubMedCrossRef Kloeckner R, dos Santos DP, Schneider J, Kara L, Dueber C, Pitton MB (2013) Radiation exposure in CT-guided interventions. Eur J Radiol 82(12):2253–2257PubMedCrossRef
8.
go back to reference Kato R, Katada K, Anno H, Suzuki S, Ida Y, Koga S (1996) Radiation dosimetry at CT fluoroscopy: physician’s hand dose and development of needle holders. Radiology 201:576–578PubMedCrossRef Kato R, Katada K, Anno H, Suzuki S, Ida Y, Koga S (1996) Radiation dosimetry at CT fluoroscopy: physician’s hand dose and development of needle holders. Radiology 201:576–578PubMedCrossRef
9.
go back to reference Solomon SB, Patriciu A, Bohlman ME, Kavoussi LR, Stoianovici D (2002) Robotically driven interventions: a method of using CT fluoroscopy without radiation exposure to the physician. Radiology 225:277–282PubMedCentralPubMedCrossRef Solomon SB, Patriciu A, Bohlman ME, Kavoussi LR, Stoianovici D (2002) Robotically driven interventions: a method of using CT fluoroscopy without radiation exposure to the physician. Radiology 225:277–282PubMedCentralPubMedCrossRef
10.
go back to reference Shin TY, Choi KH, Lim SK et al (2013) Simplified zero ischemia in robot assisted partial nephrectomy: initial yonsei experience. Kor J Urol 54:78–84CrossRef Shin TY, Choi KH, Lim SK et al (2013) Simplified zero ischemia in robot assisted partial nephrectomy: initial yonsei experience. Kor J Urol 54:78–84CrossRef
11.
go back to reference Paul J, Vogl TJ, Mbalisike EC (2012) Radiation dose and image quality evaluation relative to different contrast media using cone-beam CT. Imaging Med 4(5):505–513CrossRef Paul J, Vogl TJ, Mbalisike EC (2012) Radiation dose and image quality evaluation relative to different contrast media using cone-beam CT. Imaging Med 4(5):505–513CrossRef
12.
go back to reference Paul J, Bauer RW, Maentele W, Vogl TJ (2011) Image fusion in dual energy computed tomography for detection of various anatomic structures–effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality. Eur J Radiol 80(2):612–619PubMedCrossRef Paul J, Bauer RW, Maentele W, Vogl TJ (2011) Image fusion in dual energy computed tomography for detection of various anatomic structures–effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality. Eur J Radiol 80(2):612–619PubMedCrossRef
13.
go back to reference Paul J, Krauss B, Banckwitz R, Maentele W, Bauer RW, Vogl TJ (2012) Relationships of clinical protocols and reconstruction kernels with image quality and radiation dose in a 128-slice CT scanner: study with an anthropomorphic and water phantom. Eur J Radiol 81(5):e699–e703PubMedCrossRef Paul J, Krauss B, Banckwitz R, Maentele W, Bauer RW, Vogl TJ (2012) Relationships of clinical protocols and reconstruction kernels with image quality and radiation dose in a 128-slice CT scanner: study with an anthropomorphic and water phantom. Eur J Radiol 81(5):e699–e703PubMedCrossRef
14.
go back to reference Paul J, Jacobi V, Bazrafshan B, Farshid P, Vogl T (2013) Effect of contrast material on radiation dose in an adult cardiac dual-energy CT using retrospective ECG-gating. Health Phys 105(2):156–164PubMedCrossRef Paul J, Jacobi V, Bazrafshan B, Farshid P, Vogl T (2013) Effect of contrast material on radiation dose in an adult cardiac dual-energy CT using retrospective ECG-gating. Health Phys 105(2):156–164PubMedCrossRef
15.
go back to reference Koelblinger C, Schima W, Berger-Kulemann V et al (2013) C-arm CT during hepatic arteriography tumour-to-liver contrast: intraindividual comparison of three different contrast media application protocols. Eur Radiol 23:938–942PubMedCrossRef Koelblinger C, Schima W, Berger-Kulemann V et al (2013) C-arm CT during hepatic arteriography tumour-to-liver contrast: intraindividual comparison of three different contrast media application protocols. Eur Radiol 23:938–942PubMedCrossRef
16.
go back to reference Goldberg SN, Grassi CJ, Cardella JF et al (2005) Image-guided tumor ablation: Standardization of terminology and reporting criteria. Radiology 235:728–739PubMedCentralPubMedCrossRef Goldberg SN, Grassi CJ, Cardella JF et al (2005) Image-guided tumor ablation: Standardization of terminology and reporting criteria. Radiology 235:728–739PubMedCentralPubMedCrossRef
17.
go back to reference Paul J, Schell B, Kerl JM, Maentele W, Vogl TJ, Bauer RW (2011) Effect of contrast material on image noise and radiation dose in adult chest computed tomography using automatic exposure control: a comparative study between 16-, 64-and 128-slice CT. Eur J Radiol 79(2):e128–e132PubMedCrossRef Paul J, Schell B, Kerl JM, Maentele W, Vogl TJ, Bauer RW (2011) Effect of contrast material on image noise and radiation dose in adult chest computed tomography using automatic exposure control: a comparative study between 16-, 64-and 128-slice CT. Eur J Radiol 79(2):e128–e132PubMedCrossRef
18.
go back to reference Paul J, Mbalisike EC, Nour-Eldin NE, Vogl TJ (2013) Dual-source 128-slice MDCT neck: radiation dose and image quality estimation of three different protocols. Eur J Radiol 82(5):787–796PubMedCrossRef Paul J, Mbalisike EC, Nour-Eldin NE, Vogl TJ (2013) Dual-source 128-slice MDCT neck: radiation dose and image quality estimation of three different protocols. Eur J Radiol 82(5):787–796PubMedCrossRef
19.
go back to reference Tam AL, Mohamed A, Pfister M et al (2010) C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty. Spine 35:1095–1099PubMed Tam AL, Mohamed A, Pfister M et al (2010) C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty. Spine 35:1095–1099PubMed
20.
go back to reference Schulz B, Eichler K, Siebenhandl P et al (2013) Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study. Eur Radiol 23:198–204PubMedCrossRef Schulz B, Eichler K, Siebenhandl P et al (2013) Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study. Eur Radiol 23:198–204PubMedCrossRef
Metadata
Title
Image-guided microwave thermoablation of hepatic tumours using novel robotic guidance: an early experience
Authors
Emmanuel C. Mbalisike
Thomas J. Vogl
Stefan Zangos
Katrin Eichler
Prakash Balakrishnan
Jijo Paul
Publication date
01-02-2015
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 2/2015
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-014-3398-0

Other articles of this Issue 2/2015

European Radiology 2/2015 Go to the issue