Skip to main content
Top
Published in: European Radiology 8/2011

01-08-2011 | Cardiac

Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients

Authors: Ming-li Sun, Bin Lu, Run-ze Wu, Laura Johnson, Lei Han, Gang Liu, Fang-Fang Yu, Zhi-hui Hou, Yang Gao, Hong-yu Wang, Shiliang Jiang, Yue-jin Yang, Shu-bin Qiao

Published in: European Radiology | Issue 8/2011

Login to get access

Abstract

Objective

To evaluate the diagnostic accuracy of dual-source CT (DSCT) prospective ECG-triggering coronary angiography in patients with different heart rate (HR).

Methods

103 patients with suspected coronary artery disease underwent DSCT prospective ECG-triggered coronary angiography and invasive coronary angiography (ICA). The patients were grouped by HR during CT scans: low HR (≤60 bpm, n = 34); medium HR (60 < HR ≤ 70 bpm, n = 36) and high HR (>70 bpm, n = 33). The sensitivity and specificity of DSCT in detecting ≥50% stenosis were compared among subgroups where ICA was the gold standard. Image quality was scored using a 4-point scale.

Results

A total of 1,580 (95.9%) coronary artery segments were evaluable. Sensitivity and specificity were 82.8% and 98.4%, 88.3% and 98.7%, and 80.3% and 98.6% for different subgroups (all p > 0.05). The overall area under the curve of the receiver-operating characteristic analysis was 0.94. The image quality scores were 3.1 ± 0.3, 3.1 ± 0.3 and 3.0 ± 0.4 for subgroups (p > 0.05). The overall average effective radiation dose was 3.60 ± 1.60 mSv.

Conclusion

DSCT coronary angiography with prospective ECG-triggering could be just as accurate in patients with medium to high HR compared to those with low HR.
Literature
1.
go back to reference Donald LJ, Robert JA, Todd MB et al (2010) Heart disease and stroke statistics—2010 update: a report from the American Heart Association. Circulation 121:948–954CrossRef Donald LJ, Robert JA, Todd MB et al (2010) Heart disease and stroke statistics—2010 update: a report from the American Heart Association. Circulation 121:948–954CrossRef
2.
go back to reference Gaziano TA (2007) Reducing the growing burden of cardiovascular disease in the developing world. Health Aff 26:13–24CrossRef Gaziano TA (2007) Reducing the growing burden of cardiovascular disease in the developing world. Health Aff 26:13–24CrossRef
3.
4.
go back to reference Einstein AJ, Henzlova MJ, Rajagopalan S (2007) Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 298:317–323PubMedCrossRef Einstein AJ, Henzlova MJ, Rajagopalan S (2007) Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 298:317–323PubMedCrossRef
5.
go back to reference Ketelsen D, Thomas C, Werner M et al (2010) Dual-source computed tomography: estimation of radiation exposure of ECG-gated and ECG-triggered coronary angiography. Eur J Radiol 73:274–279PubMedCrossRef Ketelsen D, Thomas C, Werner M et al (2010) Dual-source computed tomography: estimation of radiation exposure of ECG-gated and ECG-triggered coronary angiography. Eur J Radiol 73:274–279PubMedCrossRef
6.
go back to reference Schoenhagen P (2008) Back to the future: coronary CT angiography using prospective ECG triggering. Eur Heart J 29:153–154PubMedCrossRef Schoenhagen P (2008) Back to the future: coronary CT angiography using prospective ECG triggering. Eur Heart J 29:153–154PubMedCrossRef
7.
go back to reference Ko SM, Kim NR, Kim DH et al (2010) Assessment of image quality and radiation dose in prospective ECG-triggered coronary CT angiography compared with retrospective ECG-gated coronary CT angiography. Int J Cardiovasc Imaging 26:93–101PubMedCrossRef Ko SM, Kim NR, Kim DH et al (2010) Assessment of image quality and radiation dose in prospective ECG-triggered coronary CT angiography compared with retrospective ECG-gated coronary CT angiography. Int J Cardiovasc Imaging 26:93–101PubMedCrossRef
8.
go back to reference Klass O, Jeltsch M, Feuerlein S et al (2009) Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique. Eur Radiol 19:829–836PubMedCrossRef Klass O, Jeltsch M, Feuerlein S et al (2009) Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique. Eur Radiol 19:829–836PubMedCrossRef
9.
go back to reference Earls JP, Berman E, Urban BA et al (2008) Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 246:742–753PubMedCrossRef Earls JP, Berman E, Urban BA et al (2008) Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 246:742–753PubMedCrossRef
10.
go back to reference Alkadhi H, Stolzmann P, Scheffel H et al (2008) Radiation dose of cardiac dual-source CT: the effect of tailoring the protocol to patient-specific parameters. Eur J Radiol 68:385–391PubMedCrossRef Alkadhi H, Stolzmann P, Scheffel H et al (2008) Radiation dose of cardiac dual-source CT: the effect of tailoring the protocol to patient-specific parameters. Eur J Radiol 68:385–391PubMedCrossRef
11.
go back to reference Pflederer T, Jakstat J, Marwan M et al (2010) Radiation exposure and image quality in staged low-dose protocols for coronary dual-source CT angiography: a randomized comparison. Eur Radiol 20:1197–1206PubMedCrossRef Pflederer T, Jakstat J, Marwan M et al (2010) Radiation exposure and image quality in staged low-dose protocols for coronary dual-source CT angiography: a randomized comparison. Eur Radiol 20:1197–1206PubMedCrossRef
12.
go back to reference Hein F, Meyer T, Hadamitzky M et al (2009) Prospective ECG-triggered sequential scan protocol for coronary dual-source CT angiography: initial experience. Int J Cardiovasc Imaging 25:231–239CrossRef Hein F, Meyer T, Hadamitzky M et al (2009) Prospective ECG-triggered sequential scan protocol for coronary dual-source CT angiography: initial experience. Int J Cardiovasc Imaging 25:231–239CrossRef
13.
go back to reference Scheffel H, Alkadhi H, Leschka S et al (2008) Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance. Heart 94:1132–1137PubMedCrossRef Scheffel H, Alkadhi H, Leschka S et al (2008) Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance. Heart 94:1132–1137PubMedCrossRef
14.
go back to reference Herzog BA, Husmann L, Burkhard N et al (2008) Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience. Eur Heart J 29:3037–3042PubMedCrossRef Herzog BA, Husmann L, Burkhard N et al (2008) Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience. Eur Heart J 29:3037–3042PubMedCrossRef
15.
go back to reference Achenbach S, Anders K, Kalender WA (2008) Dual-source cardiac computed tomography: image quality and dose considerations. Eur Radiol 18:1188–1198PubMedCrossRef Achenbach S, Anders K, Kalender WA (2008) Dual-source cardiac computed tomography: image quality and dose considerations. Eur Radiol 18:1188–1198PubMedCrossRef
16.
go back to reference Srichai MB, Hecht EM, Kim D et al (2009) Dual-Source computed tomography angiography image quality in patients with fast heart rates. J Cardiovasc Comput Tomogr 3:300–309PubMedCrossRef Srichai MB, Hecht EM, Kim D et al (2009) Dual-Source computed tomography angiography image quality in patients with fast heart rates. J Cardiovasc Comput Tomogr 3:300–309PubMedCrossRef
17.
go back to reference Maruyama T, Takada M, Hasuike T et al (2008) Radiation dose reduction and coronary assessability of prospective electrocardiogram-gated computed tomography coronary angiography: comparison with retrospective electrocardiogram-gated helical scan. J Am Coll Cardiol 52:1450–1455PubMedCrossRef Maruyama T, Takada M, Hasuike T et al (2008) Radiation dose reduction and coronary assessability of prospective electrocardiogram-gated computed tomography coronary angiography: comparison with retrospective electrocardiogram-gated helical scan. J Am Coll Cardiol 52:1450–1455PubMedCrossRef
18.
go back to reference Husmann L, Valenta I, Gaemperli O et al (2008) Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating. Eur Heart J 29:191–197PubMedCrossRef Husmann L, Valenta I, Gaemperli O et al (2008) Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating. Eur Heart J 29:191–197PubMedCrossRef
19.
go back to reference Alkadhi H, Scheffel H, Desbiolles L et al (2008) Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy. Eur Heart J 29:766–776PubMedCrossRef Alkadhi H, Scheffel H, Desbiolles L et al (2008) Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy. Eur Heart J 29:766–776PubMedCrossRef
20.
go back to reference Rixe J, Rolf A, Conradi G et al (2008) Image quality on dual-source computed-tomographic coronary angiography. Eur Radiol 18:1857–1862PubMedCrossRef Rixe J, Rolf A, Conradi G et al (2008) Image quality on dual-source computed-tomographic coronary angiography. Eur Radiol 18:1857–1862PubMedCrossRef
21.
go back to reference Rixe J, Rolf A, Conradi G et al (2009) Detection of relevant coronary artery disease using dual-source computed tomography in a high probability patient series: comparison with invasive angiography. Circ J 73:316–322PubMedCrossRef Rixe J, Rolf A, Conradi G et al (2009) Detection of relevant coronary artery disease using dual-source computed tomography in a high probability patient series: comparison with invasive angiography. Circ J 73:316–322PubMedCrossRef
22.
go back to reference Ropers U, Ropers D, Pflederer T et al (2007) Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography. J Am Coll Cardiol 50:2393–2398PubMedCrossRef Ropers U, Ropers D, Pflederer T et al (2007) Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography. J Am Coll Cardiol 50:2393–2398PubMedCrossRef
23.
go back to reference Lu B, Mao SS, Zhuang N et al (2001) Coronary artery motion during the cardiac cycle and optimal ECG triggering for coronary artery imaging. Invest Radiol 36:250–256PubMedCrossRef Lu B, Mao SS, Zhuang N et al (2001) Coronary artery motion during the cardiac cycle and optimal ECG triggering for coronary artery imaging. Invest Radiol 36:250–256PubMedCrossRef
24.
go back to reference Lell M, Marwan M, Schepis T et al (2009) Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience. Eur Radiol 19:2576–2583PubMedCrossRef Lell M, Marwan M, Schepis T et al (2009) Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience. Eur Radiol 19:2576–2583PubMedCrossRef
25.
go back to reference Xu Y, Tang LJ, Zhu XM et al (2010) Comparison of dual-source CT coronary angiography and conventional coronary angiography for detecting coronary artery disease. Int J Cardiovasc Imaging 26:75–81PubMedCrossRef Xu Y, Tang LJ, Zhu XM et al (2010) Comparison of dual-source CT coronary angiography and conventional coronary angiography for detecting coronary artery disease. Int J Cardiovasc Imaging 26:75–81PubMedCrossRef
26.
go back to reference Herzog BA, Wyss CA, Husmann L et al (2009) First head-to-head comparison of effective radiation dose from low-dose 64-slice CT with prospective ECG-triggering versus invasive coronary angiography. Heart 95:1656–1661PubMedCrossRef Herzog BA, Wyss CA, Husmann L et al (2009) First head-to-head comparison of effective radiation dose from low-dose 64-slice CT with prospective ECG-triggering versus invasive coronary angiography. Heart 95:1656–1661PubMedCrossRef
Metadata
Title
Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients
Authors
Ming-li Sun
Bin Lu
Run-ze Wu
Laura Johnson
Lei Han
Gang Liu
Fang-Fang Yu
Zhi-hui Hou
Yang Gao
Hong-yu Wang
Shiliang Jiang
Yue-jin Yang
Shu-bin Qiao
Publication date
01-08-2011
Publisher
Springer-Verlag
Published in
European Radiology / Issue 8/2011
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-011-2107-5

Other articles of this Issue 8/2011

European Radiology 8/2011 Go to the issue