Skip to main content
Top
Published in: European Radiology 8/2011

01-08-2011 | Musculoskeletal

Brachial plexus MR imaging: accuracy and reproducibility of DTI-derived measurements and fibre tractography at 3.0-T

Authors: Alberto Tagliafico, Massimo Calabrese, Matteo Puntoni, Daniele Pace, Gabriella Baio, Carlo Emanuele Neumaier, Carlo Martinoli

Published in: European Radiology | Issue 8/2011

Login to get access

Abstract

Objective

To estimate intrastudy, intraobserver and interobserver reproducibility of DTI-derived measurements and fibre tractography (FT) at 3.0 T MR imaging in subjects without known brachial plexus pathology.

Methods

IRB approval and written informed consent were obtained. Forty healthy volunteers underwent bilateral 3.0-T DTI of the brachial plexus. Postprocessing included FT and analysis of fractional anisotropy (FA) and apparent diffusion coefficient (ADC). Four authors performed postprocessing and analysis independently and in different sessions at baseline and after 4 weeks. Non-parametric tests and Bland-Altman statistics were used.

Results

Minimum and maximum percent variability were 6% and 20% for FA (85%–93% reproducibility). For ADC minimum and maximum percent variability were 6% and 18% (86%–97% reproducibility). Quality of fibre tract was rated equal in 80% and slightly different in 20% of subjects. Minimum detectable differences between limb were 37% for FA and 32% for ADC. Intra- and inter-observer agreement were good. Evaluating the combined influence of the observer and of the repeated measurements the reproducibility was 81–92%.

Conclusion

DTI of brachial plexus nerves is reliable. The healthy contralateral side can be used as an internal control considering that changes in FA and ADC values of less that 37% and 32% will not be clinically detectable with confidence.
Literature
1.
go back to reference Mori S, van Zijl PC (2002) Fiber tracking: principles and strategies: a technical review. NMR Biomed 15:468–480PubMedCrossRef Mori S, van Zijl PC (2002) Fiber tracking: principles and strategies: a technical review. NMR Biomed 15:468–480PubMedCrossRef
2.
go back to reference Mori S, Barker PB (1999) Diffusion magnetic resonance imaging: its principle and applications. Anat Rec 257:102–109PubMedCrossRef Mori S, Barker PB (1999) Diffusion magnetic resonance imaging: its principle and applications. Anat Rec 257:102–109PubMedCrossRef
4.
go back to reference Bammer R, Acar B, Moseley ME (2003) In vivo MR tractography using diffusion imaging. Eur J Radiol 45:223–234PubMedCrossRef Bammer R, Acar B, Moseley ME (2003) In vivo MR tractography using diffusion imaging. Eur J Radiol 45:223–234PubMedCrossRef
5.
go back to reference Nucifora PG, Verma R, Lee SK, Melhem ER (2007) Diffusion-tensor MR imaging and tractography: exploring brain microstructure and connectivity. Radiology 245:367–384PubMedCrossRef Nucifora PG, Verma R, Lee SK, Melhem ER (2007) Diffusion-tensor MR imaging and tractography: exploring brain microstructure and connectivity. Radiology 245:367–384PubMedCrossRef
6.
go back to reference Basser P, Mattiello J, LeBihan D (1994) MR diffusion tensor spectroscopy and imaging. Biophys J 66:259–267PubMedCrossRef Basser P, Mattiello J, LeBihan D (1994) MR diffusion tensor spectroscopy and imaging. Biophys J 66:259–267PubMedCrossRef
7.
go back to reference Toosy AT, Werring DJ, Orrell RW et al (2003) Diffusion tensor imaging detects corticospinal tract involvement at multiple levels in amyotrophic lateral sclerosis. J Neurol Neurosurg Psychiatry 74:1250–1257PubMedCrossRef Toosy AT, Werring DJ, Orrell RW et al (2003) Diffusion tensor imaging detects corticospinal tract involvement at multiple levels in amyotrophic lateral sclerosis. J Neurol Neurosurg Psychiatry 74:1250–1257PubMedCrossRef
8.
go back to reference Conturo TE, Lori NF, Cull TS et al (1999) Tracking neuronal fiber pathways in the living human brain. Proc Natl Acad Sci USA 96:10422–10427PubMedCrossRef Conturo TE, Lori NF, Cull TS et al (1999) Tracking neuronal fiber pathways in the living human brain. Proc Natl Acad Sci USA 96:10422–10427PubMedCrossRef
9.
go back to reference Renoux J, Facon D, Fillard P et al (2006) MR diffusion tensor imaging and fiber tracking in inflammatory diseases of the spinal cord. AJNR Am J Neuroradiol 27:1947–1951PubMed Renoux J, Facon D, Fillard P et al (2006) MR diffusion tensor imaging and fiber tracking in inflammatory diseases of the spinal cord. AJNR Am J Neuroradiol 27:1947–1951PubMed
10.
go back to reference Demir A, Ries M, Moonen CT et al (2003) Diffusion-weighted MR imaging with apparent diffusion coefficient and apparent diffusion tensor maps in cervical spondylotic myelopathy. Radiology 229:37–43PubMedCrossRef Demir A, Ries M, Moonen CT et al (2003) Diffusion-weighted MR imaging with apparent diffusion coefficient and apparent diffusion tensor maps in cervical spondylotic myelopathy. Radiology 229:37–43PubMedCrossRef
11.
go back to reference Hori M, Okubo T, Aoki S et al (2006) Line scan diffusion tensor MRI at low magnetic field strength: feasibility study of cervical spondylotic myelopathy in an early clinical stage. J Magn Reson Imaging 23:183–188PubMedCrossRef Hori M, Okubo T, Aoki S et al (2006) Line scan diffusion tensor MRI at low magnetic field strength: feasibility study of cervical spondylotic myelopathy in an early clinical stage. J Magn Reson Imaging 23:183–188PubMedCrossRef
12.
go back to reference Mamata H, Jolesz FA, Maier SE (2005) Apparent diffusion coefficient and fractional anisotropy in spinal cord: age and cervical spondylosis-related changes. J Magn Reson Imaging 22:38–43PubMedCrossRef Mamata H, Jolesz FA, Maier SE (2005) Apparent diffusion coefficient and fractional anisotropy in spinal cord: age and cervical spondylosis-related changes. J Magn Reson Imaging 22:38–43PubMedCrossRef
13.
14.
go back to reference Xiangshui M, Xiangjun C, Xiaoming Z et al (2010) 3 T magnetic resonance diffusion tensor imaging and fibre tracking in cervical myelopathy. Clin Radiol 65:465–473PubMedCrossRef Xiangshui M, Xiangjun C, Xiaoming Z et al (2010) 3 T magnetic resonance diffusion tensor imaging and fibre tracking in cervical myelopathy. Clin Radiol 65:465–473PubMedCrossRef
15.
go back to reference Vargas MI, Viallon M, Nguyen D, Delavelle J, Becker M (2010) Diffusion tensor imaging (DTI) and tractography of the brachial plexus: feasibility and initial experience in neoplastic conditions. Neuroradiology 52:237–245PubMedCrossRef Vargas MI, Viallon M, Nguyen D, Delavelle J, Becker M (2010) Diffusion tensor imaging (DTI) and tractography of the brachial plexus: feasibility and initial experience in neoplastic conditions. Neuroradiology 52:237–245PubMedCrossRef
16.
go back to reference Kabakci N, Gurses B, Firat Z et al (2007) Diffusion tensor imaging and tractography of median nerve: normative diffusion values. AJR Am J Roentgenol 189:923–927PubMedCrossRef Kabakci N, Gurses B, Firat Z et al (2007) Diffusion tensor imaging and tractography of median nerve: normative diffusion values. AJR Am J Roentgenol 189:923–927PubMedCrossRef
17.
go back to reference Andreisek G, White LM, Kassner A, Sussman MS (2010) Evaluation of diffusion tensor imaging and fiber tractography of the median nerve: preliminary results on intrasubject variability and precision of measurements. AJR Am J Roentgenol 194:W65–W72PubMedCrossRef Andreisek G, White LM, Kassner A, Sussman MS (2010) Evaluation of diffusion tensor imaging and fiber tractography of the median nerve: preliminary results on intrasubject variability and precision of measurements. AJR Am J Roentgenol 194:W65–W72PubMedCrossRef
18.
go back to reference Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef
19.
go back to reference Bland JM, Altman DG (1996) Measurement error proportional to the mean. BMJ 313:106PubMed Bland JM, Altman DG (1996) Measurement error proportional to the mean. BMJ 313:106PubMed
20.
21.
go back to reference Padhani AR, Hayes C, Landau S, Leach MO (2002) Reproducibility of quantitative dynamic MRI of normal human tissues. NMR Biomed 15:143–153PubMedCrossRef Padhani AR, Hayes C, Landau S, Leach MO (2002) Reproducibility of quantitative dynamic MRI of normal human tissues. NMR Biomed 15:143–153PubMedCrossRef
22.
go back to reference Di Leo G, Di Terlizzi F, Flor N, Morganti A, Sardanelli F (2010) Measurement of renal volume using respiratory-gated MRI in subjects without known kidney disease: intraobserver, interobserver, and interstudy reproducibility. Eur J Radiol. doi:10.1016/j.ejrad.2010.09.005 Di Leo G, Di Terlizzi F, Flor N, Morganti A, Sardanelli F (2010) Measurement of renal volume using respiratory-gated MRI in subjects without known kidney disease: intraobserver, interobserver, and interstudy reproducibility. Eur J Radiol. doi:10.​1016/​j.​ejrad.​2010.​09.​005
23.
go back to reference Farrell JA, Landman BA, Jones CK, Smith SA, Prince JL, van Zijl PC et al (2007) Effects of signal-to-noise ratio on the accuracy and reproducibility of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5 T. J Magn Reson Imaging 26:756–767PubMedCrossRef Farrell JA, Landman BA, Jones CK, Smith SA, Prince JL, van Zijl PC et al (2007) Effects of signal-to-noise ratio on the accuracy and reproducibility of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5 T. J Magn Reson Imaging 26:756–767PubMedCrossRef
24.
go back to reference Bankier AA, Levine D, Halpern EF, Kressel HY (2010) Consensus interpretation in imaging research: is there a better way? Radiology 257:14–17PubMedCrossRef Bankier AA, Levine D, Halpern EF, Kressel HY (2010) Consensus interpretation in imaging research: is there a better way? Radiology 257:14–17PubMedCrossRef
25.
go back to reference Braithwaite AC, Dale BM, Boll DT, Merkle EM (2009) Short- and midterm reproducibility of apparent diffusion coefficient measurements at 3.0-T diffusion-weighted imaging of the abdomen. Radiology 250:459–465PubMedCrossRef Braithwaite AC, Dale BM, Boll DT, Merkle EM (2009) Short- and midterm reproducibility of apparent diffusion coefficient measurements at 3.0-T diffusion-weighted imaging of the abdomen. Radiology 250:459–465PubMedCrossRef
26.
go back to reference Martinoli C, Gandolfo N, Miguel Perez M, Klauser A, Palmieri F, Padua L et al (2010) Brachial plexus and nerves about the shoulder. Semin Musculoskelet Radiol 14:523–546PubMedCrossRef Martinoli C, Gandolfo N, Miguel Perez M, Klauser A, Palmieri F, Padua L et al (2010) Brachial plexus and nerves about the shoulder. Semin Musculoskelet Radiol 14:523–546PubMedCrossRef
27.
go back to reference Tagliafico A, Altafini L, Garello I, Marchetti A, Gennaro S, Martinoli C (2010) Traumatic neuropathies: spectrum of imaging findings and postoperative assessment. Semin Musculoskelet Radiol 14:512–522PubMedCrossRef Tagliafico A, Altafini L, Garello I, Marchetti A, Gennaro S, Martinoli C (2010) Traumatic neuropathies: spectrum of imaging findings and postoperative assessment. Semin Musculoskelet Radiol 14:512–522PubMedCrossRef
Metadata
Title
Brachial plexus MR imaging: accuracy and reproducibility of DTI-derived measurements and fibre tractography at 3.0-T
Authors
Alberto Tagliafico
Massimo Calabrese
Matteo Puntoni
Daniele Pace
Gabriella Baio
Carlo Emanuele Neumaier
Carlo Martinoli
Publication date
01-08-2011
Publisher
Springer-Verlag
Published in
European Radiology / Issue 8/2011
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-011-2100-z

Other articles of this Issue 8/2011

European Radiology 8/2011 Go to the issue