Skip to main content
Top
Published in: European Radiology 7/2010

01-07-2010 | Breast

Vacuum-assisted biopsies under MR guidance: results of 72 procedures

Authors: C. Malhaire, C. El Khoury, F. Thibault, A. Athanasiou, P. Petrow, L. Ollivier, A. Tardivon

Published in: European Radiology | Issue 7/2010

Login to get access

Abstract

Objective

To investigate the clinical accuracy of magnetic resonance imaging-guided breast vacuum-assisted biopsy (MR-VAB).

Methods

Of 97 scheduled MR-VAB for single MRI lesions (negative second-look sonography) categorised as BI-RADS 4 or 5, 4 were cancelled (undetected lesion = 2, technical problems = 2). Twenty-one patients lost to follow-up were excluded.

Results

Twenty-three patients (median age 51 years) were at high risk (BRCA1 = 11, BRCA2 = 7, familial risk = 5), 23 had a suspected local recurrence of breast cancer. Seventy-two imaged lesions (focus = 1, mass enhancement = 32, non-mass-like enhancement = 39) were targeted with a 10-gauge VAB probe using MRI guidance, with a median of 18 specimens per lesion (median procedural time 72 min, range 50–131 min) followed by clip placement. In the case of benignity, MRI follow-up was performed (19 patients, median 389 days, range 33–1,592) or mammography (3 patients, median 420 days, range 372–1,354). According to histopathology results, 29 lesions were benign, 10 were high-risk (papillary = 2, radial scar = 1, atypical epithelial hyperplasia = 7) and 33 malignant (ductal carcinoma in situ = 8, invasive cancers = 25). Three false negative results and 3 complications occurred (1 malaise, 1 skin defect, 1 infection).

Conclusion

MRI-guided VAB represents an accurate tool for the histological diagnosis of lesions visible only at MRI.
Literature
1.
go back to reference Kuhl CK (2007) Current status of breast imaging. Part 1. Choice of technique, image interpretation, diagnostic accuracy, and transfer to clinical practice. Radiology 244:356–378CrossRefPubMed Kuhl CK (2007) Current status of breast imaging. Part 1. Choice of technique, image interpretation, diagnostic accuracy, and transfer to clinical practice. Radiology 244:356–378CrossRefPubMed
2.
go back to reference Morrow M (2008) Magnetic resonance imaging in the breast cancer patient: curb your enthusiasm. J Clin Oncol 26:352–353CrossRefPubMed Morrow M (2008) Magnetic resonance imaging in the breast cancer patient: curb your enthusiasm. J Clin Oncol 26:352–353CrossRefPubMed
3.
go back to reference Morrow M (2004) Magnetic resonance imaging in the preoperative evaluation of breast cancer: primum non nocere. J Am Coll Surg 198:240–241CrossRefPubMed Morrow M (2004) Magnetic resonance imaging in the preoperative evaluation of breast cancer: primum non nocere. J Am Coll Surg 198:240–241CrossRefPubMed
4.
go back to reference Houssami N, Ciatto S, Macaskill P, Lord SJ, Warren RM, Dixon JM, Irwing L (2008) Accuracy and surgical impact of magnetic resonance imaging in breast cancer staging: systematic review and meta-analysis in detection of multifocal and multicentric cancer. J Clin Oncol 26:3248–3258CrossRefPubMed Houssami N, Ciatto S, Macaskill P, Lord SJ, Warren RM, Dixon JM, Irwing L (2008) Accuracy and surgical impact of magnetic resonance imaging in breast cancer staging: systematic review and meta-analysis in detection of multifocal and multicentric cancer. J Clin Oncol 26:3248–3258CrossRefPubMed
5.
go back to reference Solin LJ, Orel SG, Hwang WT, Harris EE, Schnall MD (2008) Relationship of breast magnetic resonance imaging to outcome after breast-conservation treatment with radiation for women with early-stage invasive breast carcinoma or ductal carcinoma in situ. J Clin Oncol 26:386–391CrossRefPubMed Solin LJ, Orel SG, Hwang WT, Harris EE, Schnall MD (2008) Relationship of breast magnetic resonance imaging to outcome after breast-conservation treatment with radiation for women with early-stage invasive breast carcinoma or ductal carcinoma in situ. J Clin Oncol 26:386–391CrossRefPubMed
6.
go back to reference Fischer U, Zachariae O, Baum F, von Heyden D, Funke M, Liersch T (2004) The influence of preoperative MRI of the breasts on recurrence rate in patients with breast cancer. Eur Radiol 14:1725–1731PubMed Fischer U, Zachariae O, Baum F, von Heyden D, Funke M, Liersch T (2004) The influence of preoperative MRI of the breasts on recurrence rate in patients with breast cancer. Eur Radiol 14:1725–1731PubMed
7.
go back to reference Lee CH, Smith RC, Levine JA, Troiano RN, Tocino I (1999) Clinical usefulness of MR imaging of the breast in the evaluation of the problematic mammogram. AJR Am J Roentgenol 173:1323–1329PubMed Lee CH, Smith RC, Levine JA, Troiano RN, Tocino I (1999) Clinical usefulness of MR imaging of the breast in the evaluation of the problematic mammogram. AJR Am J Roentgenol 173:1323–1329PubMed
8.
go back to reference Orel SG, Weinstein SP, Schnall MD, Reynolds CA, Schuchter LM, Fraker DL, Solin LJ (1999) Breast MR imaging in patients with axillary node metastases and unknown primary site. Radiology 212:543–549PubMed Orel SG, Weinstein SP, Schnall MD, Reynolds CA, Schuchter LM, Fraker DL, Solin LJ (1999) Breast MR imaging in patients with axillary node metastases and unknown primary site. Radiology 212:543–549PubMed
9.
go back to reference Kuhl CK (2007) Current status of breast MR imaging. Part 2. Clinical applications. Radiology 244:672–691CrossRefPubMed Kuhl CK (2007) Current status of breast MR imaging. Part 2. Clinical applications. Radiology 244:672–691CrossRefPubMed
10.
go back to reference Lehman CD, Isaacs C, Schnall MD, Pisano ED, Asher SM, Weatherall PT, Bluemke DA, Bowen DJ, Marcom PK, Armstrong DK, Domchek SM, Tomlinson G, Skates SJ, Gatsonis C (2007) Cancer yield of mammography, MR and US in high-risk women: prospective multi-institution breast cancer screening study. Radiology 244:381–388CrossRefPubMed Lehman CD, Isaacs C, Schnall MD, Pisano ED, Asher SM, Weatherall PT, Bluemke DA, Bowen DJ, Marcom PK, Armstrong DK, Domchek SM, Tomlinson G, Skates SJ, Gatsonis C (2007) Cancer yield of mammography, MR and US in high-risk women: prospective multi-institution breast cancer screening study. Radiology 244:381–388CrossRefPubMed
11.
go back to reference Kriege M, Brekelmans CT, Boetes C, Besnard PE, Zonderland HM, Obdeijn IM, Manoliu RA, Kok T, Peterse H, Tilanus-Linthorst MM, Muller SH, Meijer S, Oosterwijk JC, Beex LV, Tollenaar RA, de Koning HJ, Rutgers EJ, Klijn JG (2004) Efficacy of MRI and mammography for breast-cancer screening in women with a familial or genetic predisposition. N Engl J Med 351:427–437CrossRefPubMed Kriege M, Brekelmans CT, Boetes C, Besnard PE, Zonderland HM, Obdeijn IM, Manoliu RA, Kok T, Peterse H, Tilanus-Linthorst MM, Muller SH, Meijer S, Oosterwijk JC, Beex LV, Tollenaar RA, de Koning HJ, Rutgers EJ, Klijn JG (2004) Efficacy of MRI and mammography for breast-cancer screening in women with a familial or genetic predisposition. N Engl J Med 351:427–437CrossRefPubMed
12.
go back to reference Leach MO, Boggis CR, Dixon AK, Easton DF, Eeles RA, Evans DG, Gilbert FJ, Griebsch I, Hoff RJ, Kessar P, Lakhani SR, Moss SM, Nerurkar A, Padhani AR, Pointon LJ, Thompson D, Warren RM, MARIBS study group (2005) Screening with magnetic resonance imaging and mammography of a UK population at high familial risk of breast cancer: a prospective multicentre cohort study (MARIBS). Lancet 365:1769–1778CrossRefPubMed Leach MO, Boggis CR, Dixon AK, Easton DF, Eeles RA, Evans DG, Gilbert FJ, Griebsch I, Hoff RJ, Kessar P, Lakhani SR, Moss SM, Nerurkar A, Padhani AR, Pointon LJ, Thompson D, Warren RM, MARIBS study group (2005) Screening with magnetic resonance imaging and mammography of a UK population at high familial risk of breast cancer: a prospective multicentre cohort study (MARIBS). Lancet 365:1769–1778CrossRefPubMed
13.
go back to reference DeMartini WB, Eby PR, Peacock S, Lehman CD (2009) Utility of targeted sonography for breast lesions that were suspicious on MRI. AJR Am J Roentgenol 192:1128–1134CrossRefPubMed DeMartini WB, Eby PR, Peacock S, Lehman CD (2009) Utility of targeted sonography for breast lesions that were suspicious on MRI. AJR Am J Roentgenol 192:1128–1134CrossRefPubMed
14.
go back to reference Heywang-Kobrunner SH, Sinnatamby R, Lebeau A, Lebrecht A, Britton PD, Schreer I, consensus group (2008) Interdisciplinary consensus on the uses and technique of MRI-guided vacuum assisted breast biopsy (VAB): results of a consensus meeting. Eur J Radiol. doi:10.1016/j.ejrad.2008.07.010 PubMed Heywang-Kobrunner SH, Sinnatamby R, Lebeau A, Lebrecht A, Britton PD, Schreer I, consensus group (2008) Interdisciplinary consensus on the uses and technique of MRI-guided vacuum assisted breast biopsy (VAB): results of a consensus meeting. Eur J Radiol. doi:10.​1016/​j.​ejrad.​2008.​07.​010 PubMed
15.
go back to reference Jackman RJ, Marzoni FA, Rosenberg J (2009) False-negative diagnoses at stereotactic vacuum-assisted needle breast biopsy: long-term follow-up of 1280 lesions and review of the literature. AJR Am J Roentgenol 192:341–351CrossRefPubMed Jackman RJ, Marzoni FA, Rosenberg J (2009) False-negative diagnoses at stereotactic vacuum-assisted needle breast biopsy: long-term follow-up of 1280 lesions and review of the literature. AJR Am J Roentgenol 192:341–351CrossRefPubMed
16.
go back to reference Philpotts LE, Hooley RJ, Lee CH (2003) Comparison of automated versus vacuum-assisted biopsy methods for sonographically guided core biopsy of the breast. AJR Am J Roentgenol 180:347–351PubMed Philpotts LE, Hooley RJ, Lee CH (2003) Comparison of automated versus vacuum-assisted biopsy methods for sonographically guided core biopsy of the breast. AJR Am J Roentgenol 180:347–351PubMed
17.
go back to reference Heywang-Kobrunner SH, Heinig A, Schaumloffel U, Viehweg P, Buchmann J, Lampe D, Spielmann RP (1999) MR-guided percutaneous excisional and incisional biopsy of breast lesions. Eur Radiol 9:1656–1665CrossRefPubMed Heywang-Kobrunner SH, Heinig A, Schaumloffel U, Viehweg P, Buchmann J, Lampe D, Spielmann RP (1999) MR-guided percutaneous excisional and incisional biopsy of breast lesions. Eur Radiol 9:1656–1665CrossRefPubMed
18.
go back to reference Perlet C, Heinig A, Prat X, Casselman J, Baath L, Sittek H, Stets C, Lamarque J, Anderson I, Schneider P, Taourel P, Reiser M, Heywang-Kobrunner SH (2002) Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast. Eur Radiol 12:1463–1470CrossRefPubMed Perlet C, Heinig A, Prat X, Casselman J, Baath L, Sittek H, Stets C, Lamarque J, Anderson I, Schneider P, Taourel P, Reiser M, Heywang-Kobrunner SH (2002) Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast. Eur Radiol 12:1463–1470CrossRefPubMed
19.
go back to reference Liberman L, Morris EA, Dershaw DD, Thornton CM, Van Zee KJ, Tan LK (2003) Fast MR-guided vacuum-assisted breast biopsy: initial experience. AJR Am J Roentgenol 181:1283–1293PubMed Liberman L, Morris EA, Dershaw DD, Thornton CM, Van Zee KJ, Tan LK (2003) Fast MR-guided vacuum-assisted breast biopsy: initial experience. AJR Am J Roentgenol 181:1283–1293PubMed
20.
go back to reference Lehman CD, DePeri ER, Peacock S, McDonough MD, DeMartini WB, Shook J (2005) Clinical experience with MRI-guided vacuum-assisted breast biopsy. AJR Am J Roentgenol 184:1782–1787PubMed Lehman CD, DePeri ER, Peacock S, McDonough MD, DeMartini WB, Shook J (2005) Clinical experience with MRI-guided vacuum-assisted breast biopsy. AJR Am J Roentgenol 184:1782–1787PubMed
21.
go back to reference Liberman L, Bracero N, Morris E, Thornton C, Dershaw DD (2005) MRI-guided 9-gauge vacuum-assisted breast biopsy: initial clinical experience. AJR Am J Roentgenol 185:183–193PubMed Liberman L, Bracero N, Morris E, Thornton C, Dershaw DD (2005) MRI-guided 9-gauge vacuum-assisted breast biopsy: initial clinical experience. AJR Am J Roentgenol 185:183–193PubMed
22.
go back to reference Orel SG, Rosen M, Mies C, Schnall MD (2006) MR imaging-guided 9-gauge vacuum-assisted core-needle breast biopsy: initial experience. Radiology 238:54–61CrossRefPubMed Orel SG, Rosen M, Mies C, Schnall MD (2006) MR imaging-guided 9-gauge vacuum-assisted core-needle breast biopsy: initial experience. Radiology 238:54–61CrossRefPubMed
23.
go back to reference Perlet C, Heywang-Kobrunner SH, Heinig A, Sittek H, Casselman J, Anderson I, Taourel P (2006) Magnetic resonance-guided, vacuum-assisted breast biopsy. Results from a European multicenter study of 538 lesions. Cancer 106:982–990CrossRefPubMed Perlet C, Heywang-Kobrunner SH, Heinig A, Sittek H, Casselman J, Anderson I, Taourel P (2006) Magnetic resonance-guided, vacuum-assisted breast biopsy. Results from a European multicenter study of 538 lesions. Cancer 106:982–990CrossRefPubMed
24.
go back to reference Ghate SV, Rosen EL, Soo MSC, Baker JA (2006) MRI-guided vacuum-assisted breast biopsy with a handheld portable biopsy system. AJR Am J Roentgenol 186:1733–1736CrossRefPubMed Ghate SV, Rosen EL, Soo MSC, Baker JA (2006) MRI-guided vacuum-assisted breast biopsy with a handheld portable biopsy system. AJR Am J Roentgenol 186:1733–1736CrossRefPubMed
25.
go back to reference American College of Radiology (2003) Magnetic resonance imaging. In: American College of Radiology. Breast imaging reporting and data system: breast imaging atlas (BI-RADS), 4th edn. American College of Radiology, Reston American College of Radiology (2003) Magnetic resonance imaging. In: American College of Radiology. Breast imaging reporting and data system: breast imaging atlas (BI-RADS), 4th edn. American College of Radiology, Reston
26.
go back to reference Claus EB, Risch N, Thompson WD (1991) Genetic analysis of breast cancer in the Cancer and Steroid Hormone Study. Am J Hum Genet 48:232–242PubMed Claus EB, Risch N, Thompson WD (1991) Genetic analysis of breast cancer in the Cancer and Steroid Hormone Study. Am J Hum Genet 48:232–242PubMed
27.
go back to reference Elston CW, Ellis IO (1991) Pathological prognostic factors in breast cancer. Part 1. The value of histological grade in breast cancer: experience from a large study with long term follow-up. Histopathology 19:403–410CrossRefPubMed Elston CW, Ellis IO (1991) Pathological prognostic factors in breast cancer. Part 1. The value of histological grade in breast cancer: experience from a large study with long term follow-up. Histopathology 19:403–410CrossRefPubMed
28.
go back to reference Hauth EA, Jaeger HJ, Lubnau J, Maderwald S, Otterbach F, Kimmig R, Forsting M (2008) MR-guided vacuum-assisted breast biopsy with a handheld biopsy system: clinical experience and results in postinterventional MR mammography after 24 h. Eur Radiol 18:168–176CrossRefPubMed Hauth EA, Jaeger HJ, Lubnau J, Maderwald S, Otterbach F, Kimmig R, Forsting M (2008) MR-guided vacuum-assisted breast biopsy with a handheld biopsy system: clinical experience and results in postinterventional MR mammography after 24 h. Eur Radiol 18:168–176CrossRefPubMed
29.
go back to reference Han BK, Schnall MD, Orel SG, Rosen M (2008) Outcome of MRI-guided breast biopsy. AJR Am J Roentgenol 191:1798–1804CrossRefPubMed Han BK, Schnall MD, Orel SG, Rosen M (2008) Outcome of MRI-guided breast biopsy. AJR Am J Roentgenol 191:1798–1804CrossRefPubMed
30.
go back to reference Kuhl CK, Schrading S, Bieling HB, Wardelmann E, Leutner CC, Koenig R, Kuhn W, Schild HH (2007) MRI for diagnosis of pure ductal carcinoma in situ: a prospective observational study. Lancet 11:485–492CrossRef Kuhl CK, Schrading S, Bieling HB, Wardelmann E, Leutner CC, Koenig R, Kuhn W, Schild HH (2007) MRI for diagnosis of pure ductal carcinoma in situ: a prospective observational study. Lancet 11:485–492CrossRef
31.
go back to reference Lee J, Kaplan JB, Murray MP, Mazur-Grbec M, Tadic T, Stimac D, Liberman L (2007) Underestimation of DCIS at MRI-guided vacuum-assisted breast biopsy. AJR Am J Roentgenol 189:468–474CrossRefPubMed Lee J, Kaplan JB, Murray MP, Mazur-Grbec M, Tadic T, Stimac D, Liberman L (2007) Underestimation of DCIS at MRI-guided vacuum-assisted breast biopsy. AJR Am J Roentgenol 189:468–474CrossRefPubMed
32.
go back to reference Lee J, Kaplan JB, Murray MP, Bartella L, Morris EA, Joo S, Dershaw DD, Liberman L (2007) Imaging histologic discordance at MRI-guided 9-gauge vacuum-assisted breast biopsy. AJR Am J Roentgenol 189:852–859CrossRefPubMed Lee J, Kaplan JB, Murray MP, Bartella L, Morris EA, Joo S, Dershaw DD, Liberman L (2007) Imaging histologic discordance at MRI-guided 9-gauge vacuum-assisted breast biopsy. AJR Am J Roentgenol 189:852–859CrossRefPubMed
33.
go back to reference Liberman L, Benton CL, Dershaw DD, Abramson AF, LaTrenta LR, Morris EA (2001) Learning curve for stereotactic breast biopsy: how many cases are enough? AJR Am J Roentgenol 176:721–727PubMed Liberman L, Benton CL, Dershaw DD, Abramson AF, LaTrenta LR, Morris EA (2001) Learning curve for stereotactic breast biopsy: how many cases are enough? AJR Am J Roentgenol 176:721–727PubMed
34.
go back to reference Gebauer B, Bostanjoglo M, Moesta KT, Schneider W, Schlag PM, Felix R (2006) Magnetic resonance-guided biopsy of suspicious breast lesions with a handheld vacuum biopsy device. Acta Radiol 47:903–913CrossRef Gebauer B, Bostanjoglo M, Moesta KT, Schneider W, Schlag PM, Felix R (2006) Magnetic resonance-guided biopsy of suspicious breast lesions with a handheld vacuum biopsy device. Acta Radiol 47:903–913CrossRef
35.
go back to reference Liberman L, Morris EA, Lee MJ, Kaplan JB, LaTrenta LR, Menell JH, Abramson AF, Dashnaw SM, Ballon DJ, Dershaw DD (2002) Breast lesions detected on MR imaging: features and positive predictive value. AJR Am J Roentgenol 179:171–178PubMed Liberman L, Morris EA, Lee MJ, Kaplan JB, LaTrenta LR, Menell JH, Abramson AF, Dashnaw SM, Ballon DJ, Dershaw DD (2002) Breast lesions detected on MR imaging: features and positive predictive value. AJR Am J Roentgenol 179:171–178PubMed
Metadata
Title
Vacuum-assisted biopsies under MR guidance: results of 72 procedures
Authors
C. Malhaire
C. El Khoury
F. Thibault
A. Athanasiou
P. Petrow
L. Ollivier
A. Tardivon
Publication date
01-07-2010
Publisher
Springer-Verlag
Published in
European Radiology / Issue 7/2010
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-009-1707-9

Other articles of this Issue 7/2010

European Radiology 7/2010 Go to the issue