Skip to main content
Top
Published in: European Radiology 9/2009

01-09-2009 | Musculoskeletal

CT-guided radiofrequency ablation of spinal osteoid osteomas with concomitant perineural and epidural irrigation for neuroprotection

Authors: Darren Klass, Tom Marshall, Andoni Toms

Published in: European Radiology | Issue 9/2009

Login to get access

Abstract

Here we report our experience of a neuroprotective adaptation of the technique of CT-guided radiofrequency (RF) ablation of spinal osteoid osteomas. Over 9 years seven patients underwent eight CT-guided RF treatments for osteoid osteoma. CT-guided RF ablation was performed with general anaesthesia. The lesion was heated to 90°C for 2 min for two cycles by using a Cosman SMK TC-10 RF electrode. This was preceded by a bolus of room temperature sterile water (10 ml) injected through a 26G curved spinal needle into the exit foramen and adjacent epidural space for neuroprotection. The age of the patient, sex, lesion location, biopsy results and complications were recorded. All the biopsies (n = 7) demonstrated histological features of osteoid osteoma. All the procedures were technically successful. Clinical success was assessed up to 3 years post procedure. There was an 85% clinical success rate (6 of the 7 patients), with recurrence of a lesion at 6 months, necessitating a repeat procedure (successful). CT-guided percutaneous RF ablation of spinal osteoid osteoma preceded by bolus of sterile water, injected through a spinal needle into the exit foramen and adjacent epidural space for neuroprotection, is a safe and effective procedure.
Literature
1.
go back to reference Zileli M, Cagli S, Basdemir G, Ersahin Y (2003) Osteoid osteomas and osteoblastomas of the spine. Neurosurg Focus 15;15(5):E5 Zileli M, Cagli S, Basdemir G, Ersahin Y (2003) Osteoid osteomas and osteoblastomas of the spine. Neurosurg Focus 15;15(5):E5
2.
go back to reference Samaha EI, Ghanem IB, Moussa RF, Kharrat KE, Okais NM, Dagher FM (2005) Percutaneous radiofrequency coagulation of osteoid osteoma of the “neural spinal ring”. Eur Spine J 14:702–705PubMedCrossRef Samaha EI, Ghanem IB, Moussa RF, Kharrat KE, Okais NM, Dagher FM (2005) Percutaneous radiofrequency coagulation of osteoid osteoma of the “neural spinal ring”. Eur Spine J 14:702–705PubMedCrossRef
3.
go back to reference Rosenthal DI, Springfield DS, Gebhardt MC, Rosenberg AE, Mankin HJ (1995) Osteoid osteoma: percutaneous radio-frequency ablation. Radiology 197(2):451–454PubMed Rosenthal DI, Springfield DS, Gebhardt MC, Rosenberg AE, Mankin HJ (1995) Osteoid osteoma: percutaneous radio-frequency ablation. Radiology 197(2):451–454PubMed
4.
go back to reference Hadjipavlou AG, Lander PH, Marchesi D, Katonis PG, Gaitanis IN (2003) Minimally invasive surgery for ablation of osteoid osteoma of the spine. Spine 28(22):E472–E477PubMedCrossRef Hadjipavlou AG, Lander PH, Marchesi D, Katonis PG, Gaitanis IN (2003) Minimally invasive surgery for ablation of osteoid osteoma of the spine. Spine 28(22):E472–E477PubMedCrossRef
5.
go back to reference Gangi A, Alizadeh H, Wong L, Buy X, Dietemann JL, Roy C (2007) Osteoid osteoma: percutaneous laser ablation and follow-up in 114 patients. Radiology 242(1):293–301PubMedCrossRef Gangi A, Alizadeh H, Wong L, Buy X, Dietemann JL, Roy C (2007) Osteoid osteoma: percutaneous laser ablation and follow-up in 114 patients. Radiology 242(1):293–301PubMedCrossRef
6.
go back to reference Kirwan EO, Hutton PA, Pozo JL, Ransford AO (1984) Osteoid osteoma and benign osteoblastoma of the spine. Clinical presentation and treatment. J Bone Joint Surg Br 66(1):81–86 Kirwan EO, Hutton PA, Pozo JL, Ransford AO (1984) Osteoid osteoma and benign osteoblastoma of the spine. Clinical presentation and treatment. J Bone Joint Surg Br 66(1):81–86
7.
go back to reference Poey C, Clement JL, Baunin C, Assoun C, Puget-Mechinaud C, Giron J et al (1991) Percutaneous extraction of an osteoid osteoma of the lumbar spine under CT guidance. J Comput Assist Tomogr 15(6):1056–1058PubMedCrossRef Poey C, Clement JL, Baunin C, Assoun C, Puget-Mechinaud C, Giron J et al (1991) Percutaneous extraction of an osteoid osteoma of the lumbar spine under CT guidance. J Comput Assist Tomogr 15(6):1056–1058PubMedCrossRef
8.
go back to reference Labbe JL, Clement JL, Duparc B, Poey C, Railhac JJ (1995) Percutaneous extraction of vertebral osteoid osteoma under computed tomography guidance. Eur Spine J 4(6):368–371PubMedCrossRef Labbe JL, Clement JL, Duparc B, Poey C, Railhac JJ (1995) Percutaneous extraction of vertebral osteoid osteoma under computed tomography guidance. Eur Spine J 4(6):368–371PubMedCrossRef
9.
go back to reference Sans N, Galy-Fourcade, Assoun J, Jarlaud T, Chiavassa H, Bonnevialle P, Railhac N, Giron J, Morera-Maupome H, Railhac J-J (1999) Osteoid osteoma: CT-guided percutaneous resection and follow-up in 38 patients. Radiology 212(3):687–692 Sans N, Galy-Fourcade, Assoun J, Jarlaud T, Chiavassa H, Bonnevialle P, Railhac N, Giron J, Morera-Maupome H, Railhac J-J (1999) Osteoid osteoma: CT-guided percutaneous resection and follow-up in 38 patients. Radiology 212(3):687–692
10.
go back to reference Vanderschueren GM, Taminiau AHM, Obermann WR, Bloem JL (2002) Osteoid osteoma: clinical results with thermocoagulation. Radiology 224(1):82–86PubMedCrossRef Vanderschueren GM, Taminiau AHM, Obermann WR, Bloem JL (2002) Osteoid osteoma: clinical results with thermocoagulation. Radiology 224(1):82–86PubMedCrossRef
11.
go back to reference Laus M, Albisinni U, Alfonso C, Zappoli FA (2007) Osteoid osteoma of the cervical spine: surgical treatment or percutaneous radiofrequency coagulation? Eur Spine J 16:2078–2082PubMedCrossRef Laus M, Albisinni U, Alfonso C, Zappoli FA (2007) Osteoid osteoma of the cervical spine: surgical treatment or percutaneous radiofrequency coagulation? Eur Spine J 16:2078–2082PubMedCrossRef
12.
go back to reference Woertler K, Vestring T, Boettner F, Winkelmann W, Heindel W, Lindner N (2001) Osteoid osteoma: CT-guided percutaneous radiofrequency ablation and follow-up in 47 patients. J Vasc Interv Radiol 12(6):717–722PubMedCrossRef Woertler K, Vestring T, Boettner F, Winkelmann W, Heindel W, Lindner N (2001) Osteoid osteoma: CT-guided percutaneous radiofrequency ablation and follow-up in 47 patients. J Vasc Interv Radiol 12(6):717–722PubMedCrossRef
13.
go back to reference Rosenthal DI, Hornicek FJ, Wolfe MW, Jennings LC, Gebhardt MC, Mankin HJ (1998) Percutaneous radiofrequency coagulation of osteoid osteoma compared with operative treatment. J Bone Joint Surg Am 7(5):422–425 Rosenthal DI, Hornicek FJ, Wolfe MW, Jennings LC, Gebhardt MC, Mankin HJ (1998) Percutaneous radiofrequency coagulation of osteoid osteoma compared with operative treatment. J Bone Joint Surg Am 7(5):422–425
14.
go back to reference Venbrux AC, Montague BJ, Murphy KP, Bobonis LA, Washington SB, Soltes AP, Frassica FJ (2003) Image-guided percutaneous radiofrequency ablation for osteoid osteomas. J Vasc Interv Radiol 14(3):375–380PubMed Venbrux AC, Montague BJ, Murphy KP, Bobonis LA, Washington SB, Soltes AP, Frassica FJ (2003) Image-guided percutaneous radiofrequency ablation for osteoid osteomas. J Vasc Interv Radiol 14(3):375–380PubMed
15.
go back to reference Rosenthal DI, Hornicek FJ, Torriani M, Gebhardt MC, Mankin HJ (2003) Osteoid osteoma: percutaneous treatment with radiofrequency energy. Radiology 229(1):171–175PubMedCrossRef Rosenthal DI, Hornicek FJ, Torriani M, Gebhardt MC, Mankin HJ (2003) Osteoid osteoma: percutaneous treatment with radiofrequency energy. Radiology 229(1):171–175PubMedCrossRef
16.
go back to reference Yamada T, Tateishi A, Cho S (1992) The effects of hyperthermia on the spinal cord. Spine 17:1386–1391 Yamada T, Tateishi A, Cho S (1992) The effects of hyperthermia on the spinal cord. Spine 17:1386–1391
17.
go back to reference Osti OL, Sebben R (1998) High-frequency radio-wave ablation of osteoid osteoma in the lumbar spine. Eur Spine J 7(5):422–425PubMedCrossRef Osti OL, Sebben R (1998) High-frequency radio-wave ablation of osteoid osteoma in the lumbar spine. Eur Spine J 7(5):422–425PubMedCrossRef
18.
go back to reference Wewers ME, Lowe MK (1990) A critical review of visual analogue scales in the measurement of clinical phenomena. Res Nurs Health 13(4):227–236PubMedCrossRef Wewers ME, Lowe MK (1990) A critical review of visual analogue scales in the measurement of clinical phenomena. Res Nurs Health 13(4):227–236PubMedCrossRef
19.
go back to reference Rosenthal DI (1997) Percutaneous radiofrequency treatment of osteoid osteomas. Semin Musculoskelet Radiol 1(2):265–272PubMedCrossRef Rosenthal DI (1997) Percutaneous radiofrequency treatment of osteoid osteomas. Semin Musculoskelet Radiol 1(2):265–272PubMedCrossRef
20.
go back to reference Vanderschueren GM, Taminiau AHM, Obermann WR, van den Berg-Huysmans AA, Bloem JL (2004) Osteoid osteoma: factors for increased risk of unsuccessful thermal coagulation. Radiology 233(3):757–761PubMedCrossRef Vanderschueren GM, Taminiau AHM, Obermann WR, van den Berg-Huysmans AA, Bloem JL (2004) Osteoid osteoma: factors for increased risk of unsuccessful thermal coagulation. Radiology 233(3):757–761PubMedCrossRef
21.
go back to reference Van Royan BJ, Baayen JC, Pijpers R, Noske DP, Schakenraad D, Wuisman PIJM (2005) Osteoid osteoma of the spine: a novel technique using combined computer-assisted and gamma probe-guided high-speed intralesional drill excision. Spine 30(3):369–373CrossRef Van Royan BJ, Baayen JC, Pijpers R, Noske DP, Schakenraad D, Wuisman PIJM (2005) Osteoid osteoma of the spine: a novel technique using combined computer-assisted and gamma probe-guided high-speed intralesional drill excision. Spine 30(3):369–373CrossRef
22.
go back to reference Nour SG, Aschoff AJ, Mitchell ICS, Emancipator SN, Duerk JL, Lewin JS (2002) MR imaging-guided radio-frequency ablation of the lumbar vertebrae in porcine models. Radiology 224(2):252–262CrossRef Nour SG, Aschoff AJ, Mitchell ICS, Emancipator SN, Duerk JL, Lewin JS (2002) MR imaging-guided radio-frequency ablation of the lumbar vertebrae in porcine models. Radiology 224(2):252–262CrossRef
23.
go back to reference Gangi A, Dietemann JL, Gasser B, Mortazavi R, Brunner P, Mourou MY, Dosch JC, Durckel J, Marescaux J, Roy C (1997) Interstitial laser photocoagulation of osteoid osteomas with use of CT guidance. Radiology 203:843–848PubMed Gangi A, Dietemann JL, Gasser B, Mortazavi R, Brunner P, Mourou MY, Dosch JC, Durckel J, Marescaux J, Roy C (1997) Interstitial laser photocoagulation of osteoid osteomas with use of CT guidance. Radiology 203:843–848PubMed
24.
go back to reference Gangi A, Dietemann J-L, Guth S, Vinclair L, Sibilia J, Mortazavi R, Steib JP, Roy C (1998) Percutaneous laser photocoagulation of spinal osteoid osteomas under CT guidance. Am J Neuroradiol 19:1955–1958PubMed Gangi A, Dietemann J-L, Guth S, Vinclair L, Sibilia J, Mortazavi R, Steib JP, Roy C (1998) Percutaneous laser photocoagulation of spinal osteoid osteomas under CT guidance. Am J Neuroradiol 19:1955–1958PubMed
25.
go back to reference Sequieiros RB, Hyvonen P, Sequeiros AB, Jyrkinen L, Ojala R, Klemola R, Vaara T, Tervonen O (2003) MR imaging guided laser ablation of osteoid osteoma with use of optical instrument guidance at 0.23T. Eur Radiol 13(10):2309–2314CrossRef Sequieiros RB, Hyvonen P, Sequeiros AB, Jyrkinen L, Ojala R, Klemola R, Vaara T, Tervonen O (2003) MR imaging guided laser ablation of osteoid osteoma with use of optical instrument guidance at 0.23T. Eur Radiol 13(10):2309–2314CrossRef
26.
go back to reference DeFriend DE, Smith SP, Hughes PM (2003) Percutaneous laser photo coagulation of osteoid osteomas under CT guidance. Clin Radiol 58(3):222–226PubMedCrossRef DeFriend DE, Smith SP, Hughes PM (2003) Percutaneous laser photo coagulation of osteoid osteomas under CT guidance. Clin Radiol 58(3):222–226PubMedCrossRef
27.
go back to reference Moser T, Giacomelli MC, Clavert JM, Buy X, Dietemann JL, Gangi A (2008) Image-guided laser ablation of osteoid osteoma in pediatric patients. J Pediatr Orthop 28(2):265–270PubMed Moser T, Giacomelli MC, Clavert JM, Buy X, Dietemann JL, Gangi A (2008) Image-guided laser ablation of osteoid osteoma in pediatric patients. J Pediatr Orthop 28(2):265–270PubMed
28.
go back to reference Mahnken AH, Tacke JA, Wildberger JE, Günther RW (2006) Radiofrequency ablation of osteoid osteoma: initial results with a bipolar ablation device. J Vasc Interv Radiol 17(9):1465–1470PubMedCrossRef Mahnken AH, Tacke JA, Wildberger JE, Günther RW (2006) Radiofrequency ablation of osteoid osteoma: initial results with a bipolar ablation device. J Vasc Interv Radiol 17(9):1465–1470PubMedCrossRef
29.
go back to reference Hadjipavlou AG, Tzermiadianos MN, Kakavelakis KN, Lander P (2008) Percutaneous core excision and radiofrequency thermo-coagulation for the ablation of osteoid osteoma of the spine. Eur Spine J. doi:10.1007/s00586-008-0791-x Hadjipavlou AG, Tzermiadianos MN, Kakavelakis KN, Lander P (2008) Percutaneous core excision and radiofrequency thermo-coagulation for the ablation of osteoid osteoma of the spine. Eur Spine J. doi:10.​1007/​s00586-008-0791-x
Metadata
Title
CT-guided radiofrequency ablation of spinal osteoid osteomas with concomitant perineural and epidural irrigation for neuroprotection
Authors
Darren Klass
Tom Marshall
Andoni Toms
Publication date
01-09-2009
Publisher
Springer-Verlag
Published in
European Radiology / Issue 9/2009
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-009-1404-8

Other articles of this Issue 9/2009

European Radiology 9/2009 Go to the issue