Skip to main content
Top
Published in: European Radiology 3/2009

01-03-2009 | Urogenital

Evaluation of T2-weighted and dynamic contrast-enhanced MRI in localizing prostate cancer before repeat biopsy

Authors: Alexandre Ben Cheikh, Nicolas Girouin, Marc Colombel, Jean-Marie Maréchal, Albert Gelet, Alvine Bissery, Muriel Rabilloud, Denis Lyonnet, Olivier Rouvière

Published in: European Radiology | Issue 3/2009

Login to get access

Abstract

We assessed the accuracy of T2-weighted (T2w) and dynamic contrast-enhanced (DCE) 1.5-T magnetic resonance imaging (MRI) in localizing prostate cancer before transrectal ultrasound-guided repeat biopsy. Ninety-three patients with abnormal PSA level and negative prostate biopsy underwent T2w and DCE prostate MRI using pelvic coil before repeat biopsy. T2w and DCE images were interpreted using visual criteria only. MR results were correlated with repeat biopsy findings in ten prostate sectors. Repeat biopsy found prostate cancer in 23 patients (24.7%) and 44 sectors (6.6%). At per patient analysis, the sensitivity, specificity, positive and negative predictive values were 47.8%, 44.3%, 20.4% and 79.5% for T2w imaging and 82.6%, 20%, 24.4% and 93.3% for DCE imaging. When all suspicious areas (on T2w or DCE imaging) were taken into account, a sensitivity of 82.6% and a negative predictive value of 100% could be achieved. At per sector analysis, DCE imaging was significantly less specific (83.5% vs. 89.7%, p < 0.002) than T2w imaging; it was more sensitive (52.4% vs. 32.1%), but the difference was hardly significant (p = 0.09). T2w and DCE MRI using pelvic coil and visual diagnostic criteria can guide prostate repeat biopsy, with a good sensitivity and NPV.
Literature
1.
go back to reference Hodge KK, McNeal JE, Terris MK et al (1989) Random systematic versus directed ultrasound guided transrectal core biopsies of the prostate. J Urol 142:71–74PubMed Hodge KK, McNeal JE, Terris MK et al (1989) Random systematic versus directed ultrasound guided transrectal core biopsies of the prostate. J Urol 142:71–74PubMed
2.
go back to reference Sadeghi-Nejad H, Simmons M, Dakwar G et al (2006) Controversies in transrectal ultrasonography and prostate biopsy. Ultrasound Q 22:169–175CrossRefPubMed Sadeghi-Nejad H, Simmons M, Dakwar G et al (2006) Controversies in transrectal ultrasonography and prostate biopsy. Ultrasound Q 22:169–175CrossRefPubMed
3.
go back to reference Presti JC Jr., O’Dowd GJ, Miller MC et al (2003) Extended peripheral zone biopsy schemes increase cancer detection rates and minimize variance in prostate specific antigen and age related cancer rates: results of a community multi-practice study. J Urol 169:125–129CrossRefPubMed Presti JC Jr., O’Dowd GJ, Miller MC et al (2003) Extended peripheral zone biopsy schemes increase cancer detection rates and minimize variance in prostate specific antigen and age related cancer rates: results of a community multi-practice study. J Urol 169:125–129CrossRefPubMed
4.
go back to reference Gore JL, Shariat SF, Miles BJ et al (2001) Optimal combinations of systematic sextant and laterally directed biopsies for the detection of prostate cancer. J Urol 165:1554–1559CrossRefPubMed Gore JL, Shariat SF, Miles BJ et al (2001) Optimal combinations of systematic sextant and laterally directed biopsies for the detection of prostate cancer. J Urol 165:1554–1559CrossRefPubMed
5.
go back to reference Scattoni V, Zlotta A, Montironi R et al (2007) Extended and saturation prostatic biopsy in the diagnosis and characterisation of prostate cancer: a critical analysis of the literature. Eur Urol 52:1309–1322CrossRefPubMed Scattoni V, Zlotta A, Montironi R et al (2007) Extended and saturation prostatic biopsy in the diagnosis and characterisation of prostate cancer: a critical analysis of the literature. Eur Urol 52:1309–1322CrossRefPubMed
6.
go back to reference Levine MA, Ittman M, Melamed J et al (1998) Two consecutive sets of transrectal ultrasound guided sextant biopsies of the prostate for the detection of prostate cancer. J Urol 159:471–475CrossRefPubMed Levine MA, Ittman M, Melamed J et al (1998) Two consecutive sets of transrectal ultrasound guided sextant biopsies of the prostate for the detection of prostate cancer. J Urol 159:471–475CrossRefPubMed
7.
go back to reference Chang JJ, Shinohara K, Bhargava V et al (1998) Prospective evaluation of lateral biopsies of the peripheral zone for prostate cancer detection. J Urol 160:2111–2114CrossRefPubMed Chang JJ, Shinohara K, Bhargava V et al (1998) Prospective evaluation of lateral biopsies of the peripheral zone for prostate cancer detection. J Urol 160:2111–2114CrossRefPubMed
8.
go back to reference King CR, McNeal JE, Gill H et al (2004) Extended prostate biopsy scheme improves reliability of Gleason grading: implications for radiotherapy patients. Int J Radiat Oncol Biol Phys 59:386–391PubMed King CR, McNeal JE, Gill H et al (2004) Extended prostate biopsy scheme improves reliability of Gleason grading: implications for radiotherapy patients. Int J Radiat Oncol Biol Phys 59:386–391PubMed
9.
go back to reference Singh H, Canto EI, Shariat SF et al (2004) Predictors of prostate cancer after initial negative systematic 12 core biopsy. J Urol 171:1850–1854CrossRefPubMed Singh H, Canto EI, Shariat SF et al (2004) Predictors of prostate cancer after initial negative systematic 12 core biopsy. J Urol 171:1850–1854CrossRefPubMed
10.
go back to reference Mian BM, Naya Y, Okihara K et al (2002) Predictors of cancer in repeat extended multisite prostate biopsy in men with previous negative extended multisite biopsy. Urology 60:836–840CrossRefPubMed Mian BM, Naya Y, Okihara K et al (2002) Predictors of cancer in repeat extended multisite prostate biopsy in men with previous negative extended multisite biopsy. Urology 60:836–840CrossRefPubMed
11.
go back to reference Stewart CS, Leibovich BC, Weaver AL et al (2001) Prostate cancer diagnosis using a saturation needle biopsy technique after previous negative sextant biopsies. J Urol 166:86–91CrossRefPubMed Stewart CS, Leibovich BC, Weaver AL et al (2001) Prostate cancer diagnosis using a saturation needle biopsy technique after previous negative sextant biopsies. J Urol 166:86–91CrossRefPubMed
12.
go back to reference Djavan B, Remzi M, Marberger M (2003) When to biopsy and when to stop biopsying. Urol Clin North Am 30:253–262 viiiCrossRefPubMed Djavan B, Remzi M, Marberger M (2003) When to biopsy and when to stop biopsying. Urol Clin North Am 30:253–262 viiiCrossRefPubMed
13.
go back to reference Busby JE, Evans CP (2004) Determining variables for repeat prostate biopsy. Prostate Cancer Prostatic Dis 7:93–98CrossRefPubMed Busby JE, Evans CP (2004) Determining variables for repeat prostate biopsy. Prostate Cancer Prostatic Dis 7:93–98CrossRefPubMed
14.
go back to reference Park SJ, Miyake H, Hara I et al (2003) Predictors of prostate cancer on repeat transrectal ultrasound-guided systematic prostate biopsy. Int J Urol 10:68–71CrossRefPubMed Park SJ, Miyake H, Hara I et al (2003) Predictors of prostate cancer on repeat transrectal ultrasound-guided systematic prostate biopsy. Int J Urol 10:68–71CrossRefPubMed
15.
go back to reference Djavan B, Zlotta A, Remzi M et al (2000) Optimal predictors of prostate cancer on repeat prostate biopsy: a prospective study of 1,051 men. J Urol 163:1144–1148CrossRefPubMed Djavan B, Zlotta A, Remzi M et al (2000) Optimal predictors of prostate cancer on repeat prostate biopsy: a prospective study of 1,051 men. J Urol 163:1144–1148CrossRefPubMed
16.
go back to reference Zackrisson B, Aus G, Lilja H et al (2003) Follow-up of men with elevated prostate-specific antigen and one set of benign biopsies at prostate cancer screening. Eur Urol 43:327–332CrossRefPubMed Zackrisson B, Aus G, Lilja H et al (2003) Follow-up of men with elevated prostate-specific antigen and one set of benign biopsies at prostate cancer screening. Eur Urol 43:327–332CrossRefPubMed
17.
go back to reference Rouviere O, Hartman RP, Lyonnet D (2006) Prostate MR imaging at high-field strength: evolution or revolution? Eur Radiol 16:276–284CrossRefPubMed Rouviere O, Hartman RP, Lyonnet D (2006) Prostate MR imaging at high-field strength: evolution or revolution? Eur Radiol 16:276–284CrossRefPubMed
18.
go back to reference Kirkham AP, Emberton M, Allen C (2006) How good is MRI at detecting and characterising cancer within the prostate? Eur Urol 50:1163–1174CrossRefPubMed Kirkham AP, Emberton M, Allen C (2006) How good is MRI at detecting and characterising cancer within the prostate? Eur Urol 50:1163–1174CrossRefPubMed
19.
go back to reference Girouin N, Mege-Lechevallier F, Tonina Senes A et al (2007) Prostate dynamic contrast-enhanced MRI with simple visual diagnostic criteria: is it reasonable? Eur Radiol 17:1498–1509CrossRefPubMed Girouin N, Mege-Lechevallier F, Tonina Senes A et al (2007) Prostate dynamic contrast-enhanced MRI with simple visual diagnostic criteria: is it reasonable? Eur Radiol 17:1498–1509CrossRefPubMed
20.
go back to reference Villers A, Puech P, Mouton D et al (2006) Dynamic contrast enhanced, pelvic phased array magnetic resonance imaging of localized prostate cancer for predicting tumor volume: correlation with radical prostatectomy findings. J Urol 176:2432–2437CrossRefPubMed Villers A, Puech P, Mouton D et al (2006) Dynamic contrast enhanced, pelvic phased array magnetic resonance imaging of localized prostate cancer for predicting tumor volume: correlation with radical prostatectomy findings. J Urol 176:2432–2437CrossRefPubMed
21.
go back to reference Kim JK, Hong SS, Choi YJ et al (2005) Wash-in rate on the basis of dynamic contrast-enhanced MRI: usefulness for prostate cancer detection and localization. J Magn Reson Imaging 22:639–646CrossRefPubMed Kim JK, Hong SS, Choi YJ et al (2005) Wash-in rate on the basis of dynamic contrast-enhanced MRI: usefulness for prostate cancer detection and localization. J Magn Reson Imaging 22:639–646CrossRefPubMed
22.
go back to reference Futterer JJ, Heijmink SW, Scheenen TW et al (2006) Prostate cancer localization with dynamic contrast-enhanced MR imaging and proton MR spectroscopic imaging. Radiology 241:449–458CrossRefPubMed Futterer JJ, Heijmink SW, Scheenen TW et al (2006) Prostate cancer localization with dynamic contrast-enhanced MR imaging and proton MR spectroscopic imaging. Radiology 241:449–458CrossRefPubMed
23.
go back to reference Akin O, Sala E, Moskowitz CS et al (2006) Transition zone prostate cancers: features, detection, localization, and staging at endorectal MR imaging. Radiology 239:784–792CrossRefPubMed Akin O, Sala E, Moskowitz CS et al (2006) Transition zone prostate cancers: features, detection, localization, and staging at endorectal MR imaging. Radiology 239:784–792CrossRefPubMed
24.
go back to reference Rouviere O, Raudrant A, Ecochard R et al (2003) Characterization of time-enhancement curves of benign and malignant prostate tissue at dynamic MR imaging. Eur Radiol 13:931–942PubMed Rouviere O, Raudrant A, Ecochard R et al (2003) Characterization of time-enhancement curves of benign and malignant prostate tissue at dynamic MR imaging. Eur Radiol 13:931–942PubMed
25.
go back to reference Naughton CK, Ornstein DK, Smith DS et al (2000) Pain and morbidity of transrectal ultrasound guided prostate biopsy: a prospective randomized trial of 6 versus 12 cores. J Urol 163:168–171CrossRefPubMed Naughton CK, Ornstein DK, Smith DS et al (2000) Pain and morbidity of transrectal ultrasound guided prostate biopsy: a prospective randomized trial of 6 versus 12 cores. J Urol 163:168–171CrossRefPubMed
26.
go back to reference Beyersdorff D, Taupitz M, Winkelmann B et al (2002) Patients with a history of elevated prostate-specific antigen levels and negative transrectal US-guided quadrant or sextant biopsy results: value of MR imaging. Radiology 224:701–706CrossRefPubMed Beyersdorff D, Taupitz M, Winkelmann B et al (2002) Patients with a history of elevated prostate-specific antigen levels and negative transrectal US-guided quadrant or sextant biopsy results: value of MR imaging. Radiology 224:701–706CrossRefPubMed
27.
go back to reference Perrotti M, Han KR, Epstein RE et al (1999) Prospective evaluation of endorectal magnetic resonance imaging to detect tumor foci in men with prior negative prostastic biopsy: a pilot study. J Urol 162:1314–1317CrossRefPubMed Perrotti M, Han KR, Epstein RE et al (1999) Prospective evaluation of endorectal magnetic resonance imaging to detect tumor foci in men with prior negative prostastic biopsy: a pilot study. J Urol 162:1314–1317CrossRefPubMed
28.
go back to reference Lattouf JB, Grubb RL 3rd, Lee SJ et al (2007) Magnetic resonance imaging-directed transrectal ultrasonography-guided biopsies in patients at risk of prostate cancer. BJU Int 99:1041–1046CrossRefPubMed Lattouf JB, Grubb RL 3rd, Lee SJ et al (2007) Magnetic resonance imaging-directed transrectal ultrasonography-guided biopsies in patients at risk of prostate cancer. BJU Int 99:1041–1046CrossRefPubMed
29.
go back to reference Portalez D, Malavaud B, Herigault G et al (2004) Predicting prostate cancer with dynamic endorectal coil MR and proton spectroscopic MR imaging. J Radiol 85:1999–2004PubMed Portalez D, Malavaud B, Herigault G et al (2004) Predicting prostate cancer with dynamic endorectal coil MR and proton spectroscopic MR imaging. J Radiol 85:1999–2004PubMed
30.
go back to reference Cirillo S, Petracchini M, Della Monica P et al (2008) Value of endorectal MRI and MRS in patients with elevated prostate-specific antigen levels and previous negative biopsies to localize peripheral zone tumours. Clin Radiol 63:871–879CrossRefPubMed Cirillo S, Petracchini M, Della Monica P et al (2008) Value of endorectal MRI and MRS in patients with elevated prostate-specific antigen levels and previous negative biopsies to localize peripheral zone tumours. Clin Radiol 63:871–879CrossRefPubMed
31.
go back to reference Yuen JS, Thng CH, Tan PH et al (2004) Endorectal magnetic resonance imaging and spectroscopy for the detection of tumor foci in men with prior negative transrectal ultrasound prostate biopsy. J Urol 171:1482–1486CrossRefPubMed Yuen JS, Thng CH, Tan PH et al (2004) Endorectal magnetic resonance imaging and spectroscopy for the detection of tumor foci in men with prior negative transrectal ultrasound prostate biopsy. J Urol 171:1482–1486CrossRefPubMed
32.
go back to reference Shukla-Dave A, Hricak H, Eberhardt SC et al (2004) Chronic prostatitis: MR imaging and 1H MR spectroscopic imaging findings–initial observations. Radiology 231:717–724CrossRefPubMed Shukla-Dave A, Hricak H, Eberhardt SC et al (2004) Chronic prostatitis: MR imaging and 1H MR spectroscopic imaging findings–initial observations. Radiology 231:717–724CrossRefPubMed
33.
go back to reference Futterer JJ, Engelbrecht MR, Jager GJ et al (2007) Prostate cancer: comparison of local staging accuracy of pelvic phased-array coil alone versus integrated endorectal-pelvic phased-array coils. Local staging accuracy of prostate cancer using endorectal coil MR imaging. Eur Radiol 17:1055–1065CrossRefPubMed Futterer JJ, Engelbrecht MR, Jager GJ et al (2007) Prostate cancer: comparison of local staging accuracy of pelvic phased-array coil alone versus integrated endorectal-pelvic phased-array coils. Local staging accuracy of prostate cancer using endorectal coil MR imaging. Eur Radiol 17:1055–1065CrossRefPubMed
34.
go back to reference Puech PFJ, Ballereau C, Leroy X, Villers A, Lemaître L (2004) Etude comparative de l’IRM de prostate par voie suspubienne ou endorectale. J Radiol 85:1402CrossRef Puech PFJ, Ballereau C, Leroy X, Villers A, Lemaître L (2004) Etude comparative de l’IRM de prostate par voie suspubienne ou endorectale. J Radiol 85:1402CrossRef
35.
go back to reference Futterer JJ, Heijmink SW, Scheenen TW et al (2006) Prostate cancer: local staging at 3-T endorectal MR imaging–early experience. Radiology 238:184–191CrossRefPubMed Futterer JJ, Heijmink SW, Scheenen TW et al (2006) Prostate cancer: local staging at 3-T endorectal MR imaging–early experience. Radiology 238:184–191CrossRefPubMed
36.
go back to reference Heijmink SW, Futterer JJ, Hambrock T et al (2007) Prostate cancer: body-array versus endorectal coil MR imaging at 3 T–comparison of image quality, localization, and staging performance. Radiology 244:184–195CrossRefPubMed Heijmink SW, Futterer JJ, Hambrock T et al (2007) Prostate cancer: body-array versus endorectal coil MR imaging at 3 T–comparison of image quality, localization, and staging performance. Radiology 244:184–195CrossRefPubMed
37.
go back to reference Anastasiadis AG, Lichy MP, Nagele U et al (2006) MRI-guided biopsy of the prostate increases diagnostic performance in men with elevated or increasing PSA levels after previous negative TRUS biopsies. Eur Urol 50:738–748CrossRefPubMed Anastasiadis AG, Lichy MP, Nagele U et al (2006) MRI-guided biopsy of the prostate increases diagnostic performance in men with elevated or increasing PSA levels after previous negative TRUS biopsies. Eur Urol 50:738–748CrossRefPubMed
38.
go back to reference Singh AK, Kruecker J, Xu S et al (2008) Initial clinical experience with real-time transrectal ultrasonography-magnetic resonance imaging fusion-guided prostate biopsy. BJU Int 101:841–845CrossRefPubMed Singh AK, Kruecker J, Xu S et al (2008) Initial clinical experience with real-time transrectal ultrasonography-magnetic resonance imaging fusion-guided prostate biopsy. BJU Int 101:841–845CrossRefPubMed
39.
go back to reference Heijmink SW, van Moerkerk H, Kiemeney LA et al (2006) A comparison of the diagnostic performance of systematic versus ultrasound-guided biopsies of prostate cancer. Eur Radiol 16:927–938CrossRefPubMed Heijmink SW, van Moerkerk H, Kiemeney LA et al (2006) A comparison of the diagnostic performance of systematic versus ultrasound-guided biopsies of prostate cancer. Eur Radiol 16:927–938CrossRefPubMed
40.
go back to reference Mitterberger M, Pinggera GM, Horninger W et al (2007) Comparison of contrast enhanced color Doppler targeted biopsy to conventional systematic biopsy: impact on Gleason score. J Urol 178:464–468CrossRefPubMed Mitterberger M, Pinggera GM, Horninger W et al (2007) Comparison of contrast enhanced color Doppler targeted biopsy to conventional systematic biopsy: impact on Gleason score. J Urol 178:464–468CrossRefPubMed
41.
go back to reference Remzi M, Dobrovits M, Reissigl A et al (2004) Can Power Doppler enhanced transrectal ultrasound guided biopsy improve prostate cancer detection on first and repeat prostate biopsy? Eur Urol 46:451–456PubMed Remzi M, Dobrovits M, Reissigl A et al (2004) Can Power Doppler enhanced transrectal ultrasound guided biopsy improve prostate cancer detection on first and repeat prostate biopsy? Eur Urol 46:451–456PubMed
42.
go back to reference Ito H, Kamoi K, Yokoyama K et al (2003) Visualization of prostate cancer using dynamic contrast-enhanced MRI: comparison with transrectal power Doppler ultrasound. Br J Radiol 76:617–624CrossRefPubMed Ito H, Kamoi K, Yokoyama K et al (2003) Visualization of prostate cancer using dynamic contrast-enhanced MRI: comparison with transrectal power Doppler ultrasound. Br J Radiol 76:617–624CrossRefPubMed
43.
go back to reference Konig K, Scheipers U, Pesavento A et al (2005) Initial experiences with real-time elastography guided biopsies of the prostate. J Urol 174:115–117CrossRefPubMed Konig K, Scheipers U, Pesavento A et al (2005) Initial experiences with real-time elastography guided biopsies of the prostate. J Urol 174:115–117CrossRefPubMed
44.
go back to reference Souchon R, Rouviere O, Gelet A et al (2003) Visualisation of HIFU lesions using elastography of the human prostate in vivo: preliminary results. Ultrasound Med Biol 29:1007–1015CrossRefPubMed Souchon R, Rouviere O, Gelet A et al (2003) Visualisation of HIFU lesions using elastography of the human prostate in vivo: preliminary results. Ultrasound Med Biol 29:1007–1015CrossRefPubMed
45.
go back to reference Pallwein L, Mitterberger M, Gradl J et al (2007) Value of contrast-enhanced ultrasound and elastography in imaging of prostate cancer. Curr Opin Urol 17:39–47CrossRefPubMed Pallwein L, Mitterberger M, Gradl J et al (2007) Value of contrast-enhanced ultrasound and elastography in imaging of prostate cancer. Curr Opin Urol 17:39–47CrossRefPubMed
Metadata
Title
Evaluation of T2-weighted and dynamic contrast-enhanced MRI in localizing prostate cancer before repeat biopsy
Authors
Alexandre Ben Cheikh
Nicolas Girouin
Marc Colombel
Jean-Marie Maréchal
Albert Gelet
Alvine Bissery
Muriel Rabilloud
Denis Lyonnet
Olivier Rouvière
Publication date
01-03-2009
Publisher
Springer-Verlag
Published in
European Radiology / Issue 3/2009
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-1190-8

Other articles of this Issue 3/2009

European Radiology 3/2009 Go to the issue