Age related changes of human aortic distensibility: evaluation with ECG-gated CT

Authors: Marika Ganten, Ute Krautter, Waldemar Hosch, Jochen Hansmann, Hendrik von Tengg-Kobligk, Stefan Delorme, Hans-Ulrich Kauczor, Günter W. Kauffmann, Michael Bock

Published in: European Radiology | Issue 3/2007

Login to get access

Abstract

Aortic distensibility is a parameter to grade vascular diseases and age-related effects because it is related to the elastic properties of the vessel wall. In this study vascular cross-sectional area changes have been determined using ECG-gated CT to analyse the age dependency of aortic distensibility. Distensibility measurements of the aorta were performed in 31 subjects (28 to 85 years). Time-resolved images were acquired either with a 4- or 16-detector row CT system using a modified CT angiography protocol. Cross-sectional area changes of the aorta were calculated by semiautomatic segmentation, and distensibility values were obtained using additional systemic blood pressure measurements. The aorta could be segmented successfully in all subjects. A decrease of aortic distensibility with age was found (r=0.50). Below (above) the renal arteries, the annual decrease was Δ D infrarenal =(−2.1±0.7)·10−7 Pa−1a−1, (D suprarenal Δ=(−3.5±1.1)·10−7 Pa−1a−1). Differences between the ages, the youngest third and oldest third studied, were found to be significant (P suprarenal =0.003; P infrarenal =0.025). An age-dependent decrease of aortic wall elasticity can be determined in a modified routine CT angiography study.
Literature
1.
go back to reference Metafratzi ZM, Efremidis SC, Skopelitou AS et al (2002) The clinical significance of aortic compliance and its assessment with magnetic resonance imaging. J Cardiovasc Magn Reson 4(4):481–491CrossRefPubMed Metafratzi ZM, Efremidis SC, Skopelitou AS et al (2002) The clinical significance of aortic compliance and its assessment with magnetic resonance imaging. J Cardiovasc Magn Reson 4(4):481–491CrossRefPubMed
2.
go back to reference Laurent S, Katsahian S, Fassot C et al (2003) Aortic stiffness is an independent predictor of fatal stroke in essential hypertension. Stroke 34(5):1203–1206CrossRefPubMed Laurent S, Katsahian S, Fassot C et al (2003) Aortic stiffness is an independent predictor of fatal stroke in essential hypertension. Stroke 34(5):1203–1206CrossRefPubMed
3.
go back to reference Herrington DM, Kesler K, Reiber JC et al (2003) Arterial compliance adds to conventional risk factors for prediction of angiographic coronary artery disease. Am Heart J 146(4):662–667CrossRefPubMed Herrington DM, Kesler K, Reiber JC et al (2003) Arterial compliance adds to conventional risk factors for prediction of angiographic coronary artery disease. Am Heart J 146(4):662–667CrossRefPubMed
4.
go back to reference Blacher J, Safar ME, Guerin AP et al (2003) Aortic pulse wave velocity index and mortality in end-stage renal disease. Kidney Int 63(5):1852–1860CrossRefPubMed Blacher J, Safar ME, Guerin AP et al (2003) Aortic pulse wave velocity index and mortality in end-stage renal disease. Kidney Int 63(5):1852–1860CrossRefPubMed
5.
go back to reference Boese JM, Bock M, Schoenberg SO et al (2000) Estimation of aortic compliance using magnetic resonance pulse wave velocity measurement. Phys Med Biol 45(6):1703–1713CrossRefPubMed Boese JM, Bock M, Schoenberg SO et al (2000) Estimation of aortic compliance using magnetic resonance pulse wave velocity measurement. Phys Med Biol 45(6):1703–1713CrossRefPubMed
6.
go back to reference Kraft KA, Itskovich VV, Fei DY (2001) Rapid measurement of aortic wave velocity: in vivo evaluation. Magn Reson Med 46(1):95–102CrossRefPubMed Kraft KA, Itskovich VV, Fei DY (2001) Rapid measurement of aortic wave velocity: in vivo evaluation. Magn Reson Med 46(1):95–102CrossRefPubMed
7.
go back to reference Itskovich VV, Kraft KA, Fei DY (2001) Rapid aortic wave velocity measurement with MR imaging. Radiology 219(2):551–557PubMed Itskovich VV, Kraft KA, Fei DY (2001) Rapid aortic wave velocity measurement with MR imaging. Radiology 219(2):551–557PubMed
8.
go back to reference Bock M, Schad LR, Muller E et al (1995) Pulse wave velocity measurement using a new real-time MR-method. Magn Reson Imaging 13(1):21–29CrossRefPubMed Bock M, Schad LR, Muller E et al (1995) Pulse wave velocity measurement using a new real-time MR-method. Magn Reson Imaging 13(1):21–29CrossRefPubMed
9.
go back to reference Nollen GJ, Westerhof BE, Groenink M et al (2004) Aortic pressure-area relation in Marfan patients with and without beta blocking agents: a new non-invasive approach. Heart 90(3):314–318CrossRefPubMed Nollen GJ, Westerhof BE, Groenink M et al (2004) Aortic pressure-area relation in Marfan patients with and without beta blocking agents: a new non-invasive approach. Heart 90(3):314–318CrossRefPubMed
10.
go back to reference Mohiaddin RH, Yang GZ, Burger P et al (1992) Automatic enhancement, animation, and segmentation of flow in peripheral arteries from MR phase-shift velocity mapping. J Comput Assist Tomogr 16(2):176–181PubMedCrossRef Mohiaddin RH, Yang GZ, Burger P et al (1992) Automatic enhancement, animation, and segmentation of flow in peripheral arteries from MR phase-shift velocity mapping. J Comput Assist Tomogr 16(2):176–181PubMedCrossRef
11.
go back to reference Lalande A, Khau van Kien P, Salve N et al (2002) Automatic determination of aortic compliance with cine-magnetic resonance imaging: an application of fuzzy logic theory. Invest Radiol 37(12):685–691CrossRefPubMed Lalande A, Khau van Kien P, Salve N et al (2002) Automatic determination of aortic compliance with cine-magnetic resonance imaging: an application of fuzzy logic theory. Invest Radiol 37(12):685–691CrossRefPubMed
12.
go back to reference Wilson KA, Hoskins PR, Lee AJ et al (2000) Ultrasonic measurement of abdominal aortic aneurysm wall compliance: a reproducibility study. J Vasc Surg 31(3):507–513CrossRefPubMed Wilson KA, Hoskins PR, Lee AJ et al (2000) Ultrasonic measurement of abdominal aortic aneurysm wall compliance: a reproducibility study. J Vasc Surg 31(3):507–513CrossRefPubMed
13.
go back to reference Long A, Rouet L, Bissery A et al (2004) Aortic compliance in healthy subjects: evaluation of tissue Doppler imaging. Ultrasound Med Biol 30(6):753–759CrossRefPubMed Long A, Rouet L, Bissery A et al (2004) Aortic compliance in healthy subjects: evaluation of tissue Doppler imaging. Ultrasound Med Biol 30(6):753–759CrossRefPubMed
14.
go back to reference Erbel R, Alfonso F, Boileau C et al (2001) Diagnosis and management of aortic dissection. Eur Heart J 22(18):1642–1681CrossRefPubMed Erbel R, Alfonso F, Boileau C et al (2001) Diagnosis and management of aortic dissection. Eur Heart J 22(18):1642–1681CrossRefPubMed
15.
go back to reference Kachelriess M, Ulzheimer S, Kalender WA (2000) ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart. Med Phys 27(8):1881–1902CrossRefPubMed Kachelriess M, Ulzheimer S, Kalender WA (2000) ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart. Med Phys 27(8):1881–1902CrossRefPubMed
16.
go back to reference Boese JM, Bahner ML, Albers J et al (2000) [Optimizing temporal resolution in CT with retrospective ECG gating]. Radiologe 40(2):123–129CrossRefPubMed Boese JM, Bahner ML, Albers J et al (2000) [Optimizing temporal resolution in CT with retrospective ECG gating]. Radiologe 40(2):123–129CrossRefPubMed
17.
go back to reference Bahner ML, Boese JM, Wallschläger H et al (1999) Spiral CT of the heart with retrospective ECG-gating. Electromedica 67:37–41 Bahner ML, Boese JM, Wallschläger H et al (1999) Spiral CT of the heart with retrospective ECG-gating. Electromedica 67:37–41
18.
go back to reference Luboldt W, Straub J, Seemann M et al (1999) Effective contrast use in CT angiography and dual-phase hepatic CT performed with a subsecond scanner. Invest Radiol 34(12):751–760CrossRefPubMed Luboldt W, Straub J, Seemann M et al (1999) Effective contrast use in CT angiography and dual-phase hepatic CT performed with a subsecond scanner. Invest Radiol 34(12):751–760CrossRefPubMed
19.
go back to reference Bahner ML, Bengel A, Brix G et al (2005) Improved vascular opacification in cerebral computed tomography angiography with 80 kVp. Invest Radiol 40(4):229–234CrossRefPubMed Bahner ML, Bengel A, Brix G et al (2005) Improved vascular opacification in cerebral computed tomography angiography with 80 kVp. Invest Radiol 40(4):229–234CrossRefPubMed
20.
go back to reference Ganten M, Boese JM, Leitermann D et al (2005) Quantification of aortic elasticity: development and experimental validation of a method using computed tomography. Eur Radiol Ganten M, Boese JM, Leitermann D et al (2005) Quantification of aortic elasticity: development and experimental validation of a method using computed tomography. Eur Radiol
21.
go back to reference Boese JM, Bahner ML, Albers J, ea (2001) An improved algorithm for multi-slice cardiac CT imaging with high temporal resolution (abstr). Radiology 221(P):457 Boese JM, Bahner ML, Albers J, ea (2001) An improved algorithm for multi-slice cardiac CT imaging with high temporal resolution (abstr). Radiology 221(P):457
22.
go back to reference Lobregt S, Viergever MA (1995) A discrete dynamic contour model. Trans Med Imaging 14:12–24CrossRef Lobregt S, Viergever MA (1995) A discrete dynamic contour model. Trans Med Imaging 14:12–24CrossRef
23.
go back to reference Cohen L (1991) On active contour modelsand ballons. Image Underst 53:211–218CrossRef Cohen L (1991) On active contour modelsand ballons. Image Underst 53:211–218CrossRef
24.
go back to reference Krug R, Boese JM, Schad LR (2003) Determination of aortic compliance from magnetic resonance images using an automatic active contour model. Phys Med Biol 48(15):2391–2404CrossRefPubMed Krug R, Boese JM, Schad LR (2003) Determination of aortic compliance from magnetic resonance images using an automatic active contour model. Phys Med Biol 48(15):2391–2404CrossRefPubMed
25.
go back to reference Malina M, Lanne T, Ivancev K et al (1998) Reduced pulsatile wall motion of abdominal aortic aneurysms after endovascular repair. J Vasc Surg 27(4):624–631CrossRefPubMed Malina M, Lanne T, Ivancev K et al (1998) Reduced pulsatile wall motion of abdominal aortic aneurysms after endovascular repair. J Vasc Surg 27(4):624–631CrossRefPubMed
26.
go back to reference Nichols WW (1990) Properties of the arterial wall. In: Nichols WW, O’ Rourke MF (eds) McDonald’s blood flow in arteries. Edward Arnold, London, p 96 Nichols WW (1990) Properties of the arterial wall. In: Nichols WW, O’ Rourke MF (eds) McDonald’s blood flow in arteries. Edward Arnold, London, p 96
27.
go back to reference Mohiaddin RH, Schoser K, Amanuma M et al (1990) MR imaging of age-related dimensional changes of thoracic aorta. J Comput Assist Tomogr 14(5):748–752PubMedCrossRef Mohiaddin RH, Schoser K, Amanuma M et al (1990) MR imaging of age-related dimensional changes of thoracic aorta. J Comput Assist Tomogr 14(5):748–752PubMedCrossRef
28.
go back to reference Schoenberg SO, Wunsch C, Knopp MV et al (1999) Abdominal aortic aneurysm. Detection of multilevel vascular pathology by time-resolved multiphase 3D gadolinium MR angiography: initial report. Invest Radiol 34(10):648–659CrossRefPubMed Schoenberg SO, Wunsch C, Knopp MV et al (1999) Abdominal aortic aneurysm. Detection of multilevel vascular pathology by time-resolved multiphase 3D gadolinium MR angiography: initial report. Invest Radiol 34(10):648–659CrossRefPubMed
29.
go back to reference Hamilton M, Pickering GW, Roberts JA et al (1954) The aetiology of essential hypertension. I. The arterial pressure in the general population. Clin Sci (Lond) 13(1):11–35 Hamilton M, Pickering GW, Roberts JA et al (1954) The aetiology of essential hypertension. I. The arterial pressure in the general population. Clin Sci (Lond) 13(1):11–35
30.
go back to reference Simon AC, Safar ME, Levenson JA et al (1979) An evaluation of large arteries compliance in man. Am J Physiol 237(5):H550–H554PubMed Simon AC, Safar ME, Levenson JA et al (1979) An evaluation of large arteries compliance in man. Am J Physiol 237(5):H550–H554PubMed
31.
go back to reference Mohiaddin RH, Firmin DN, Longmore DB (1993) Age-related changes of human aortic flow wave velocity measured noninvasively by magnetic resonance imaging. J Appl Physiol 74(1):492–497PubMed Mohiaddin RH, Firmin DN, Longmore DB (1993) Age-related changes of human aortic flow wave velocity measured noninvasively by magnetic resonance imaging. J Appl Physiol 74(1):492–497PubMed
32.
go back to reference Hansen F, Bergqvist D, Mangell P et al (1993) Non-invasive measurement of pulsatile vessel diameter change and elastic properties in human arteries: a methodological study. Clin Physiol 13(6):631–643PubMed Hansen F, Bergqvist D, Mangell P et al (1993) Non-invasive measurement of pulsatile vessel diameter change and elastic properties in human arteries: a methodological study. Clin Physiol 13(6):631–643PubMed
33.
go back to reference Hahmann M, Richter GM, Schuhmacher H et al (2001) [Post-traumatic dissection of the abdominal aorta]. Radiologe 41(7):590–594CrossRefPubMed Hahmann M, Richter GM, Schuhmacher H et al (2001) [Post-traumatic dissection of the abdominal aorta]. Radiologe 41(7):590–594CrossRefPubMed
34.
go back to reference Hansmann HJ, Dobert N, Kucherer H et al. (2000) [Various spiral CT protocols and their significance in the diagnosis of aortic dissections: results of a prospective study]. Rofo 172(11):879-87PubMed Hansmann HJ, Dobert N, Kucherer H et al. (2000) [Various spiral CT protocols and their significance in the diagnosis of aortic dissections: results of a prospective study]. Rofo 172(11):879-87PubMed
35.
go back to reference O’Rourke MF (1990) Aging, high blood pressure and disease in humans. In: Nichols WW, O’Rourke MF (eds) McDonald’s Blood flow in arteries. Edward Arnold, London, p 450 O’Rourke MF (1990) Aging, high blood pressure and disease in humans. In: Nichols WW, O’Rourke MF (eds) McDonald’s Blood flow in arteries. Edward Arnold, London, p 450
36.
go back to reference Imura T, Yamamoto K, Kanamori K et al (1986) Non-invasive ultrasonic measurement of the elastic properties of the human abdominal aorta. Cardiovasc Res 20(3):208–214PubMedCrossRef Imura T, Yamamoto K, Kanamori K et al (1986) Non-invasive ultrasonic measurement of the elastic properties of the human abdominal aorta. Cardiovasc Res 20(3):208–214PubMedCrossRef
37.
go back to reference Hahmann M, Boese JM, Leitermann D et al (2001) Measurement of aortic elasticity using ECG-gated multidetector-row CT: an ex-vivo experiment (abstr.). Radiology 221(P):33 Hahmann M, Boese JM, Leitermann D et al (2001) Measurement of aortic elasticity using ECG-gated multidetector-row CT: an ex-vivo experiment (abstr.). Radiology 221(P):33
38.
go back to reference Wintersperger B, Jakobs T, Herzog P et al (2005) Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose. Eur Radiol 15(2):334–341PubMedCrossRef Wintersperger B, Jakobs T, Herzog P et al (2005) Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose. Eur Radiol 15(2):334–341PubMedCrossRef
39.
go back to reference Flohr T, Ohnesorge B, Bruder H et al (2003) Image reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system. Med Phys 30(10):2650–2662CrossRefPubMed Flohr T, Ohnesorge B, Bruder H et al (2003) Image reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system. Med Phys 30(10):2650–2662CrossRefPubMed
40.
go back to reference Taguchi K, Aradate H (1998) Algorithm for image reconstruction in multi-slice helical CT. Med Phys 25(4):550–561CrossRefPubMed Taguchi K, Aradate H (1998) Algorithm for image reconstruction in multi-slice helical CT. Med Phys 25(4):550–561CrossRefPubMed
41.
go back to reference Bundesamt für Strahlenschutz B (2003) Bekanntmachung der diagnostischen Referenzwere für radiologische und nuklearmedizinische Untersuchungen. Bundesanzeiger Nr. 143(Tab 3):17503 Bundesamt für Strahlenschutz B (2003) Bekanntmachung der diagnostischen Referenzwere für radiologische und nuklearmedizinische Untersuchungen. Bundesanzeiger Nr. 143(Tab 3):17503
Metadata
Title
Age related changes of human aortic distensibility: evaluation with ECG-gated CT
Authors
Marika Ganten
Ute Krautter
Waldemar Hosch
Jochen Hansmann
Hendrik von Tengg-Kobligk
Stefan Delorme
Hans-Ulrich Kauczor
Günter W. Kauffmann
Michael Bock
Publication date
01-03-2007
Publisher
Springer-Verlag
Published in
European Radiology / Issue 3/2007
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-006-0309-z

Other articles of this Issue 3/2007

European Radiology 3/2007 Go to the issue