Skip to main content
Top
Published in: European Radiology 7/2006

01-07-2006 | Cardiac

Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography

Comparison with cine magnetic resonance imaging

Authors: Bénédicte Belge, Emmanuel Coche, Agnès Pasquet, Jean-Louis J. Vanoverschelde, Bernhard L. Gerber

Published in: European Radiology | Issue 7/2006

Login to get access

Abstract

Retrospective reconstruction of ECG-gated images at different parts of the cardiac cycle allows the assessment of cardiac function by multi-detector row CT (MDCT) at the time of non-invasive coronary imaging. We compared the accuracy of such measurements by MDCT to cine magnetic resonance (MR). Forty patients underwent the assessment of global and regional cardiac function by 16-slice MDCT and cine MR. Left ventricular (LV) end-diastolic and end-systolic volumes estimated by MDCT (134±51 and 67±56 ml) were similar to those by MR (137±57 and 70±60 ml, respectively; both P=NS) and strongly correlated (r=0.92 and r=0.95, respectively; both P<0.001). Consequently, LV ejection fractions by MDCT and MR were also similar (55±21 vs. 56±21%; P=NS) and highly correlated (r=0.95; P<0.001). Regional end-diastolic and end-systolic wall thicknesses by MDCT were highly correlated (r=0.84 and r=0.92, respectively; both P<0.001), but significantly lower than by MR (8.3±1.8 vs. 8.8±1.9 mm and 12.7±3.4 vs. 13.3±3.5 mm, respectively; both P<0.001). Values of regional wall thickening by MDCT and MR were similar (54±30 vs. 51±31%; P=NS) and also correlated well (r=0.91; P<0.001). Retrospectively gated MDCT can accurately estimate LV volumes, EF and regional LV wall thickening compared to cine MR.
Literature
1.
go back to reference Achenbach S, Giesler T, Ropers D, Ulzheimer S, Derlien H, Schulte C et al (2001) Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography. Circulation 103:2535–2538PubMed Achenbach S, Giesler T, Ropers D, Ulzheimer S, Derlien H, Schulte C et al (2001) Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography. Circulation 103:2535–2538PubMed
2.
go back to reference Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B et al (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.Circulation 107:664–666CrossRefPubMed Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B et al (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.Circulation 107:664–666CrossRefPubMed
3.
go back to reference Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054CrossRefPubMed Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054CrossRefPubMed
4.
go back to reference Kopp AF, Schroeder S, Kuettner A, Heuschmid M, Georg C, Ohnesorge B et al (2001) Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window. Radiology 221:683–688PubMedCrossRef Kopp AF, Schroeder S, Kuettner A, Heuschmid M, Georg C, Ohnesorge B et al (2001) Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window. Radiology 221:683–688PubMedCrossRef
5.
go back to reference Wintersperger BJ, Nikolaou K (2005) Basics of cardiac MDCT: techniques and contrast application. Eur Radiol 15(Suppl 2):B2–B9PubMed Wintersperger BJ, Nikolaou K (2005) Basics of cardiac MDCT: techniques and contrast application. Eur Radiol 15(Suppl 2):B2–B9PubMed
6.
go back to reference Mochizuki T, Murase K, Higashino H, Koyama Y, Doi M, Miyagawa M et al (2000) Two- and three-dimensional CT ventriculography: a new application of helical CT. AJR Am J Roentgenol 174:203–208PubMed Mochizuki T, Murase K, Higashino H, Koyama Y, Doi M, Miyagawa M et al (2000) Two- and three-dimensional CT ventriculography: a new application of helical CT. AJR Am J Roentgenol 174:203–208PubMed
7.
go back to reference Juergens KU, Grude M, Fallenberg EM, Opitz C, Wichter T, Heindel W et al (2002) Using ECG-gated multidetector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease. AJR Am J Roentgenol 179:1545–1550PubMed Juergens KU, Grude M, Fallenberg EM, Opitz C, Wichter T, Heindel W et al (2002) Using ECG-gated multidetector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease. AJR Am J Roentgenol 179:1545–1550PubMed
8.
go back to reference Dirksen MS, Bax JJ, de Roos A, Jukema JW, van der Geest RJ, Geleijns K et al (2002) Usefulness of dynamic multislice computed tomography of left ventricular function in unstable angina pectoris and comparison with echocardiography. Am J Cardiol 90:1157–1160PubMedCrossRef Dirksen MS, Bax JJ, de Roos A, Jukema JW, van der Geest RJ, Geleijns K et al (2002) Usefulness of dynamic multislice computed tomography of left ventricular function in unstable angina pectoris and comparison with echocardiography. Am J Cardiol 90:1157–1160PubMedCrossRef
9.
go back to reference Grude M, Juergens KU, Wichter T, Paul M, Fallenberg EM, Muller JG et al (2003) Evaluation of global left ventricular myocardial function with electrocardiogram-gated multidetector computed tomography: comparison with magnetic resonance imaging. Invest Radiol 38:653–661PubMedCrossRef Grude M, Juergens KU, Wichter T, Paul M, Fallenberg EM, Muller JG et al (2003) Evaluation of global left ventricular myocardial function with electrocardiogram-gated multidetector computed tomography: comparison with magnetic resonance imaging. Invest Radiol 38:653–661PubMedCrossRef
10.
go back to reference Boehm T, Alkadhi H, Roffi M, Willmann JK, Desbiolles LM, Marincek B et al (2004) Time-effectiveness, observer-dependence, and accuracy of measurements of left ventricular ejection fraction using 4-channel MDCT. Rofo 176:529–537PubMed Boehm T, Alkadhi H, Roffi M, Willmann JK, Desbiolles LM, Marincek B et al (2004) Time-effectiveness, observer-dependence, and accuracy of measurements of left ventricular ejection fraction using 4-channel MDCT. Rofo 176:529–537PubMed
11.
go back to reference Juergens KU, Grude M, Maintz D, Fallenberg EM, Wichter T, Heindel W et al (2004) Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience. Radiology 230:403–410PubMedCrossRef Juergens KU, Grude M, Maintz D, Fallenberg EM, Wichter T, Heindel W et al (2004) Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience. Radiology 230:403–410PubMedCrossRef
12.
go back to reference Schuijf JD, Bax JJ, Jukema JW, Lamb HJ, Vliegen HW, Salm LP et al (2004) Noninvasive angiography and assessment of left ventricular function using multislice computed tomography in patients with type 2 diabetes. Diabetes Care 27:2905–2910PubMedCrossRef Schuijf JD, Bax JJ, Jukema JW, Lamb HJ, Vliegen HW, Salm LP et al (2004) Noninvasive angiography and assessment of left ventricular function using multislice computed tomography in patients with type 2 diabetes. Diabetes Care 27:2905–2910PubMedCrossRef
13.
go back to reference Salm LP, Bax JJ, Jukema JW, Schuijf JD, Vliegen HW, Lamb HJ et al (2005) Comprehensive assessment of patients after coronary artery bypass grafting by 16-detector-row computed tomography. Am Heart J 150:775–781CrossRefPubMed Salm LP, Bax JJ, Jukema JW, Schuijf JD, Vliegen HW, Lamb HJ et al (2005) Comprehensive assessment of patients after coronary artery bypass grafting by 16-detector-row computed tomography. Am Heart J 150:775–781CrossRefPubMed
14.
go back to reference Schuijf JD, Bax JJ, Salm LP, Jukema JW, Lamb HJ, van der Wall EE et al (2005) Noninvasive coronary imaging and assessment of left ventricular function using 16-slice computed tomography. Am J Cardiol 95:571–574CrossRefPubMed Schuijf JD, Bax JJ, Salm LP, Jukema JW, Lamb HJ, van der Wall EE et al (2005) Noninvasive coronary imaging and assessment of left ventricular function using 16-slice computed tomography. Am J Cardiol 95:571–574CrossRefPubMed
15.
go back to reference Schlosser T, Pagonidis K, Herborn CU, Hunold P, Waltering KU, Lauenstein TC et al (2005) Assessment of left ventricular parameters using 16-MDCT and new software for endocardial and epicardial border delineation. AJR Am J Roentgenol 184:765–773PubMed Schlosser T, Pagonidis K, Herborn CU, Hunold P, Waltering KU, Lauenstein TC et al (2005) Assessment of left ventricular parameters using 16-MDCT and new software for endocardial and epicardial border delineation. AJR Am J Roentgenol 184:765–773PubMed
16.
go back to reference Dirksen MS, Jukema JW, Bax JJ, Lamb HJ, Boersma E, Tuinenburg JC et al (2005) Cardiac multidetector-row computed tomography in patients with unstable angina. Am J Cardiol 95:457–461CrossRefPubMed Dirksen MS, Jukema JW, Bax JJ, Lamb HJ, Boersma E, Tuinenburg JC et al (2005) Cardiac multidetector-row computed tomography in patients with unstable angina. Am J Cardiol 95:457–461CrossRefPubMed
17.
go back to reference Juergens KU, Fischbach R (2005) Left ventricular function studied with MDCT. Eur Radiol 15(1)111–117 JanPubMedCrossRef Juergens KU, Fischbach R (2005) Left ventricular function studied with MDCT. Eur Radiol 15(1)111–117 JanPubMedCrossRef
18.
go back to reference Begemann PG, van Stevendaal U, Manzke R, Stork A, Weiss F, Nolte-Ernsting C et al (2005) Evaluation of spatial and temporal resolution for ECG-gated 16-row multidetector CT using a dynamic cardiac phantom. Eur Radiol 15:1015–1026PubMedCrossRef Begemann PG, van Stevendaal U, Manzke R, Stork A, Weiss F, Nolte-Ernsting C et al (2005) Evaluation of spatial and temporal resolution for ECG-gated 16-row multidetector CT using a dynamic cardiac phantom. Eur Radiol 15:1015–1026PubMedCrossRef
19.
go back to reference Coche E, Vynckier S, Prignot M (2006) Radiation dose during diagnostic work-up of pulmonary embolism: a comparative phantom study with 4-, 16-detector row CT scanners with dose modulation program and digital pulmonary angiography. Radiology. in press Coche E, Vynckier S, Prignot M (2006) Radiation dose during diagnostic work-up of pulmonary embolism: a comparative phantom study with 4-, 16-detector row CT scanners with dose modulation program and digital pulmonary angiography. Radiology. in press
20.
go back to reference Schiller NB, Shah PM, Crawford M, DeMaria A, Devereux R, Feigenbaum H et al (1989) Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr 2:358–367PubMed Schiller NB, Shah PM, Crawford M, DeMaria A, Devereux R, Feigenbaum H et al (1989) Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr 2:358–367PubMed
21.
go back to reference Juergens KU, Maintz D, Grude M, Boese JM, Heimes B, Fallenberg EM et al (2005) Multi-detector row computed tomography of the heart: does a multi-segment reconstruction algorithm improve left ventricular volume measurements? Eur Radiol 15:111–117PubMedCrossRef Juergens KU, Maintz D, Grude M, Boese JM, Heimes B, Fallenberg EM et al (2005) Multi-detector row computed tomography of the heart: does a multi-segment reconstruction algorithm improve left ventricular volume measurements? Eur Radiol 15:111–117PubMedCrossRef
22.
go back to reference Grass M, Manzke R, Nielsen T, Koken P, Proksa R, Natanzon M et al (2003) Helical cardiac cone beam reconstruction using retrospective ECG gating. Phys Med Biol 48:3069–3084CrossRefPubMed Grass M, Manzke R, Nielsen T, Koken P, Proksa R, Natanzon M et al (2003) Helical cardiac cone beam reconstruction using retrospective ECG gating. Phys Med Biol 48:3069–3084CrossRefPubMed
23.
go back to reference Schuijf JD, Bax JJ, Jukema JW, Lamb HJ, Vliegen HW, van der Wall EE et al (2005) Noninvasive evaluation of the coronary arteries with multislice computed tomography in hypertensive patients. Hypertension 45:227–232CrossRefPubMed Schuijf JD, Bax JJ, Jukema JW, Lamb HJ, Vliegen HW, van der Wall EE et al (2005) Noninvasive evaluation of the coronary arteries with multislice computed tomography in hypertensive patients. Hypertension 45:227–232CrossRefPubMed
24.
go back to reference Salm LP, Schuijf JD, de Roos A, Lamb HJ, Vliegen HW, Jukema JW et al (2005) Global and regional left ventricular function assessment with 16-detector row CT: comparison with echocardiography and cardiovascular magnetic resonance. Eur J Echocardiogr Salm LP, Schuijf JD, de Roos A, Lamb HJ, Vliegen HW, Jukema JW et al (2005) Global and regional left ventricular function assessment with 16-detector row CT: comparison with echocardiography and cardiovascular magnetic resonance. Eur J Echocardiogr
25.
go back to reference Yamamuro M, Tadamura E, Kubo S, Toyoda H, Nishina T, Ohba M et al (2005) Cardiac functional analysis with multi-detector row CT and segmental reconstruction algorithm: comparison with echocardiography, SPECT, and MR imaging. Radiology 234:381–390PubMedCrossRef Yamamuro M, Tadamura E, Kubo S, Toyoda H, Nishina T, Ohba M et al (2005) Cardiac functional analysis with multi-detector row CT and segmental reconstruction algorithm: comparison with echocardiography, SPECT, and MR imaging. Radiology 234:381–390PubMedCrossRef
26.
go back to reference Mahnken AH, Koos R, Katoh M, Spuentrup E, Busch P, Wildberger JE et al (2005) Sixteen-slice spiral CT versus MR imaging for the assessment of left ventricular function in acute myocardial infarction. Eur Radiol 15:714–720CrossRefPubMed Mahnken AH, Koos R, Katoh M, Spuentrup E, Busch P, Wildberger JE et al (2005) Sixteen-slice spiral CT versus MR imaging for the assessment of left ventricular function in acute myocardial infarction. Eur Radiol 15:714–720CrossRefPubMed
27.
go back to reference Hamer AW, Takayama M, Abraham KA, Roche AHG, Kerr AR, Williams BF et al (1994) End-systolic volume and long term survival after coronary artery bypass graft surgery in patients with impaired left ventricular function. Circulation 90:2899–2904PubMed Hamer AW, Takayama M, Abraham KA, Roche AHG, Kerr AR, Williams BF et al (1994) End-systolic volume and long term survival after coronary artery bypass graft surgery in patients with impaired left ventricular function. Circulation 90:2899–2904PubMed
28.
go back to reference Quinones MA, Greenberg BH, Kopelen HA, Koilpillai C, Limacher MC, Shindler DM et al (2000) Echocardiographic predictors of clinical outcome in patients with left ventricular dysfunction enrolled in the SOLVD registry and trials: significance of left ventricular hypertrophy. Studies of Left Ventricular Dysfunction. J Am Coll Cardiol 35:1237–1244CrossRefPubMed Quinones MA, Greenberg BH, Kopelen HA, Koilpillai C, Limacher MC, Shindler DM et al (2000) Echocardiographic predictors of clinical outcome in patients with left ventricular dysfunction enrolled in the SOLVD registry and trials: significance of left ventricular hypertrophy. Studies of Left Ventricular Dysfunction. J Am Coll Cardiol 35:1237–1244CrossRefPubMed
29.
go back to reference Haider AW, Larson MG, Benjamin EJ, Levy D (1998) Increased left ventricular mass and hypertrophy are associated with increased risk for sudden death. J Am Coll Cardiol 32:1454–1459CrossRefPubMed Haider AW, Larson MG, Benjamin EJ, Levy D (1998) Increased left ventricular mass and hypertrophy are associated with increased risk for sudden death. J Am Coll Cardiol 32:1454–1459CrossRefPubMed
30.
go back to reference Verdecchia P, Carini G, Circo A, Dovellini E, Giovannini E, Lombardo M et al (2001) Left ventricular mass and cardiovascular morbidity in essential hypertension: the MAVI study. J Am Coll Cardiol 38:1829–1835CrossRefPubMed Verdecchia P, Carini G, Circo A, Dovellini E, Giovannini E, Lombardo M et al (2001) Left ventricular mass and cardiovascular morbidity in essential hypertension: the MAVI study. J Am Coll Cardiol 38:1829–1835CrossRefPubMed
31.
go back to reference Wong M, Staszewsky L, Latini R, Barlera S, Glazer R, Aknay N et al (2004) Severity of left ventricular remodeling defines outcomes and response to therapy in heart failure: valsartan heart failure trial (Val-HeFT) echocardiographic data. J Am Coll Cardiol 43:2022–2027CrossRefPubMed Wong M, Staszewsky L, Latini R, Barlera S, Glazer R, Aknay N et al (2004) Severity of left ventricular remodeling defines outcomes and response to therapy in heart failure: valsartan heart failure trial (Val-HeFT) echocardiographic data. J Am Coll Cardiol 43:2022–2027CrossRefPubMed
32.
go back to reference Connolly HM, Oh JK, Schaff HV, Roger VL, Osborn SL, Hodge DO et al (2000) Severe aortic stenosis with low transvalvular gradient and severe left ventricular dysfunction:result of aortic valve replacement in 52 patients. Circulation 101:1940–1946PubMed Connolly HM, Oh JK, Schaff HV, Roger VL, Osborn SL, Hodge DO et al (2000) Severe aortic stenosis with low transvalvular gradient and severe left ventricular dysfunction:result of aortic valve replacement in 52 patients. Circulation 101:1940–1946PubMed
33.
go back to reference Mock MB, Rinqvist I, Fisher LD, Davis KD, Chaitman BR, Kouchoukos NT et al (1982) Survival in medically treated patients in the coronary artery surgery study (CASS) registry. Circulation 66:562–568PubMed Mock MB, Rinqvist I, Fisher LD, Davis KD, Chaitman BR, Kouchoukos NT et al (1982) Survival in medically treated patients in the coronary artery surgery study (CASS) registry. Circulation 66:562–568PubMed
34.
go back to reference Spirito P, Bellone P, Harris KM, Bernabo P, Bruzzi P, Maron BJ (2000) Magnitude of left ventricular hypertrophy and risk of sudden death in hypertrophic cardiomyopathy. N Engl J Med 342:1778–1785CrossRefPubMed Spirito P, Bellone P, Harris KM, Bernabo P, Bruzzi P, Maron BJ (2000) Magnitude of left ventricular hypertrophy and risk of sudden death in hypertrophic cardiomyopathy. N Engl J Med 342:1778–1785CrossRefPubMed
35.
go back to reference Baer FM, Voth E, Schneider CA, Theissen P, Schicha H, Sechtem U (1995) Comparison of low-dose dobutamine-gradient-echo magnetic resonance imaging and positron emission tomography with [18F]fluorodeoxyglucose in patients with chronic coronary artery disease. A functional and morphological approach to the detection of residual myocardial viability. Circulation 91:1006–1015PubMed Baer FM, Voth E, Schneider CA, Theissen P, Schicha H, Sechtem U (1995) Comparison of low-dose dobutamine-gradient-echo magnetic resonance imaging and positron emission tomography with [18F]fluorodeoxyglucose in patients with chronic coronary artery disease. A functional and morphological approach to the detection of residual myocardial viability. Circulation 91:1006–1015PubMed
36.
go back to reference Bonow RO, Bacharach SL, Crawford-Green C, Green MV (1989) Influence of temporal smoothing on quantitation of left ventricular function by gated blood pool scintigraphy. Am J Cardiol 64:921–925CrossRefPubMed Bonow RO, Bacharach SL, Crawford-Green C, Green MV (1989) Influence of temporal smoothing on quantitation of left ventricular function by gated blood pool scintigraphy. Am J Cardiol 64:921–925CrossRefPubMed
37.
go back to reference Setser RM, Fischer SE, Lorenz CH (2000) Quantification of left ventricular function with magnetic resonance images acquired in real time. J Magn Reson Imaging 12:430–438PubMedCrossRef Setser RM, Fischer SE, Lorenz CH (2000) Quantification of left ventricular function with magnetic resonance images acquired in real time. J Magn Reson Imaging 12:430–438PubMedCrossRef
Metadata
Title
Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography
Comparison with cine magnetic resonance imaging
Authors
Bénédicte Belge
Emmanuel Coche
Agnès Pasquet
Jean-Louis J. Vanoverschelde
Bernhard L. Gerber
Publication date
01-07-2006
Publisher
Springer-Verlag
Published in
European Radiology / Issue 7/2006
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-006-0169-6

Other articles of this Issue 7/2006

European Radiology 7/2006 Go to the issue