Skip to main content
Top
Published in: European Radiology 1/2006

01-01-2006 | Cardiac

The reproducibility of left ventricular volume and mass measurements: a comparison between dual-inversion-recovery black-blood sequence and SSFP

Authors: Sarah Clay, Khaled Alfakih, Daniel R. Messroghli, Timothy Jones, John P. Ridgway, Mohan U. Sivananthan

Published in: European Radiology | Issue 1/2006

Login to get access

Abstract

The aim of this study was to compare a dual-inversion-recovery black-blood (BB) magnetic resonance imaging (MRI) sequence with steady-state free precession (SSFP) for the assessment of left ventricular parameters. The improved endocardial border definition seen with SSFP was not observed at the epicardial border. Improvements in segmentation at the left ventricular epicardial border have been observed with this black-blood sequence. Left ventricular (LV) mass and LV end-diastolic volume (EDV) measurements as well as inter-observer and intra-observer variability were compared between images acquired with a dual inversion BB and SSFP sequence. The mean±1 standard deviation (SD) for LV EDV was 178.3±52.7 ml measured with SSFP and 158.8±62.2 ml with BB. This difference was not statistically significant (p=0.22). For SSFP, the mean value of LV mass was 124.0±27.0 g and 147.5±37.4 g for BB, a statistically significant difference (p<0.0001). The dual-inversion-recovery BB imaging showed improved reproducibility for LV mass measurements compared with SSFP and improved spatial resolution. For studies requiring LV mass measurements, the dual-inversion-recovery BB sequence offers improved spatial resolution and improved reproducibility to SSFP.
Literature
1.
go back to reference Bloomer T, Plein S, Radjenovic A, Higgins DM, Jones TR, Ridgway JP, Sivananthan MU (2001) Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle. J Magn Reson 14:685–692CrossRef Bloomer T, Plein S, Radjenovic A, Higgins DM, Jones TR, Ridgway JP, Sivananthan MU (2001) Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle. J Magn Reson 14:685–692CrossRef
2.
go back to reference Westbrook C (2002) MRI at a glance. Blackwell Publishing, Oxford Westbrook C (2002) MRI at a glance. Blackwell Publishing, Oxford
3.
go back to reference Plein S, Bloomer TN, Ridgway JP, Jones TR, Bainbridge GJ, Sivananthan MU (2001) Steady state free precession magnetic resonance imaging of the heart: comparison with segmented K-space gradient-echo imaging. J Magn Reson 14:230–236CrossRef Plein S, Bloomer TN, Ridgway JP, Jones TR, Bainbridge GJ, Sivananthan MU (2001) Steady state free precession magnetic resonance imaging of the heart: comparison with segmented K-space gradient-echo imaging. J Magn Reson 14:230–236CrossRef
4.
go back to reference Sinha S, Sinha U (1996) Black blood dual phase turbo FLASH MR imaging of the heart. J Magn Reson 6(3):484–494 Sinha S, Sinha U (1996) Black blood dual phase turbo FLASH MR imaging of the heart. J Magn Reson 6(3):484–494
5.
go back to reference Sinha S, Mather R, Sinha U, Goldin J, Fonarow G, Yoon H (1997) Estimation of the left ventricular ejection fraction using a multiphase, dark-blood breath-hold MR imaging technique. Am J Roentgenol 169:101–112 Sinha S, Mather R, Sinha U, Goldin J, Fonarow G, Yoon H (1997) Estimation of the left ventricular ejection fraction using a multiphase, dark-blood breath-hold MR imaging technique. Am J Roentgenol 169:101–112
6.
go back to reference Forbat SM, Karwatowski SP, Gatehouse PD, Firmin DN, Longmore DB, Underwood SR (1994) Technical note: rapid measurement of left ventricular mass by spin echo magnetic resonance imaging. Br J Radiol 67:86–90PubMed Forbat SM, Karwatowski SP, Gatehouse PD, Firmin DN, Longmore DB, Underwood SR (1994) Technical note: rapid measurement of left ventricular mass by spin echo magnetic resonance imaging. Br J Radiol 67:86–90PubMed
7.
go back to reference Longmore DB, Underwood SR, Hounsfield GN (1985) Dimensional accuracy of magnetic resonance in studies of the heart. Lancet 4:1360–1362CrossRef Longmore DB, Underwood SR, Hounsfield GN (1985) Dimensional accuracy of magnetic resonance in studies of the heart. Lancet 4:1360–1362CrossRef
8.
go back to reference Lorenz CH, Walker ES, Morgan VL, Klein SS, Graham TP (1999) Normal human right and left ventricular mass, systolic function, and gender differences by cine magnetic resonance imaging. J Cardiovasc Magn Reson 1(1):7–21PubMed Lorenz CH, Walker ES, Morgan VL, Klein SS, Graham TP (1999) Normal human right and left ventricular mass, systolic function, and gender differences by cine magnetic resonance imaging. J Cardiovasc Magn Reson 1(1):7–21PubMed
9.
go back to reference Bland JM (1995) An introduction to medical statistics. Oxford Medical publications, Oxford, pp 266–273 Bland JM (1995) An introduction to medical statistics. Oxford Medical publications, Oxford, pp 266–273
10.
go back to reference Fieno DS, Jaffe WC, Simonetti OP, Judd RM, Finn JP (2001) TrueFISP: assessment of accuracy for measurement of left ventricular mass in an animal model. J Magn Reson 15:526–531 Fieno DS, Jaffe WC, Simonetti OP, Judd RM, Finn JP (2001) TrueFISP: assessment of accuracy for measurement of left ventricular mass in an animal model. J Magn Reson 15:526–531
11.
go back to reference Moon JC, Lorenz CH, Francis JM, Smith GC, Pennell DJ (2002) Breath-hold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility. Radiology 223(3):789–797PubMed Moon JC, Lorenz CH, Francis JM, Smith GC, Pennell DJ (2002) Breath-hold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility. Radiology 223(3):789–797PubMed
12.
go back to reference Carr JC, Simonetti O, Bundy J, Li D, Pereles S, Finn JP (2001) Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. Radiology 219:828–834PubMed Carr JC, Simonetti O, Bundy J, Li D, Pereles S, Finn JP (2001) Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. Radiology 219:828–834PubMed
13.
go back to reference Thiele H, Nagel E, Paetsch I, Schnackenburg B, Bornstedt A, Kouwenhoven M, Wahl A, Schuler G, Fleck E (2001) Functional cardiac MR imaging with steady-state free precession (SSFP) significantly improves endocardial border delineation without contrast agents. J Magn Reson 14(4):362–367CrossRef Thiele H, Nagel E, Paetsch I, Schnackenburg B, Bornstedt A, Kouwenhoven M, Wahl A, Schuler G, Fleck E (2001) Functional cardiac MR imaging with steady-state free precession (SSFP) significantly improves endocardial border delineation without contrast agents. J Magn Reson 14(4):362–367CrossRef
14.
go back to reference Wintersperger BJ, Nikolaou K, Dietrich O, Rieber J, Nittka M, Reiser MF, Schoenberg SO (2003) Single breath-hold real-time cine MR imaging: improved temporal resolution using generalised autocalibrating partially parallel acquisition (GRAPPA) algorithm. Eur Radiol 12:1931–1936CrossRef Wintersperger BJ, Nikolaou K, Dietrich O, Rieber J, Nittka M, Reiser MF, Schoenberg SO (2003) Single breath-hold real-time cine MR imaging: improved temporal resolution using generalised autocalibrating partially parallel acquisition (GRAPPA) algorithm. Eur Radiol 12:1931–1936CrossRef
15.
go back to reference Van der Brink JS, Watanabe Y, Kuhl CK, Chung T, Muthupillai R, Van Cauteren M, Yamada K, Dymarkowski S, Bogaert J, Maki JH, Matos C, Casselman JW, Hoogeveen RM (2003) Implications of SENSE MR in routine clinical practice. Eur J Radiol 46:3–27CrossRefPubMed Van der Brink JS, Watanabe Y, Kuhl CK, Chung T, Muthupillai R, Van Cauteren M, Yamada K, Dymarkowski S, Bogaert J, Maki JH, Matos C, Casselman JW, Hoogeveen RM (2003) Implications of SENSE MR in routine clinical practice. Eur J Radiol 46:3–27CrossRefPubMed
16.
go back to reference Barkhausen J, Hunold P, Waltering KU (2004) MRI in coronary artery disease. Eur Radiol 14:2155–2162CrossRefPubMed Barkhausen J, Hunold P, Waltering KU (2004) MRI in coronary artery disease. Eur Radiol 14:2155–2162CrossRefPubMed
17.
go back to reference Stuber M, Botnar RM, Kissinger KV, Manning WJ (2001) Free-breathing black-blood coronary MR angiography: initial results. Radiol 219:278–283 Stuber M, Botnar RM, Kissinger KV, Manning WJ (2001) Free-breathing black-blood coronary MR angiography: initial results. Radiol 219:278–283
Metadata
Title
The reproducibility of left ventricular volume and mass measurements: a comparison between dual-inversion-recovery black-blood sequence and SSFP
Authors
Sarah Clay
Khaled Alfakih
Daniel R. Messroghli
Timothy Jones
John P. Ridgway
Mohan U. Sivananthan
Publication date
01-01-2006
Publisher
Springer-Verlag
Published in
European Radiology / Issue 1/2006
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-2853-3

Other articles of this Issue 1/2006

European Radiology 1/2006 Go to the issue