Skip to main content
Top
Published in: European Radiology 1/2006

01-01-2006 | Neuro

Fractional anisotropy and mean diffusivity measurements on normal human brain: comparison between low- and high-resolution diffusion tensor imaging sequences

Published in: European Radiology | Issue 1/2006

Login to get access

Abstract

Non-invasive in vivo visualization of white matter fiber tracts is currently feasible by means of diffusion tensor imaging (DTI) techniques. DTI-derived metrics, like fractional anisotropy (FA) and mean diffusivity (MD), have the potential to improve tissue characterization. Technical optimization of diffusion tensor sequences, including signal-to-noise ratio and spatial resolution, was performed for 20 normal subjects. High- and low-resolution DTI sequences were applied on all subjects and FA, MD parametric maps were reconstructed for both protocols. Voxel-based statistical analysis revealed regions with significantly different FA and MD values between the two sequences, while the same type of analysis was performed to illustrate regions with significantly different signal-to-noise ratio. In conclusion, optimized DTI sequences may be applied routinely in clinical practice with a standard MR scanner, while accurate quantification of FA and MD may improve lesion characterization.
Literature
1.
go back to reference Le Bihan D, Breton E, Lallemand D, Grenier P, Cabanis E, Laval-Jeantet M (1986) MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology 161:401–407PubMed Le Bihan D, Breton E, Lallemand D, Grenier P, Cabanis E, Laval-Jeantet M (1986) MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology 161:401–407PubMed
2.
go back to reference Chenevert TL, Brunberg JA, Pipe JG (1990) Anisotropic diffusion in human white matter: demonstration with MR techniques in vivo. Radiology 177:401–405PubMed Chenevert TL, Brunberg JA, Pipe JG (1990) Anisotropic diffusion in human white matter: demonstration with MR techniques in vivo. Radiology 177:401–405PubMed
3.
go back to reference Basser PJ, Pierpaoli C (1996) Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI. J Magn Reson B 111:209–219CrossRefPubMed Basser PJ, Pierpaoli C (1996) Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI. J Magn Reson B 111:209–219CrossRefPubMed
4.
go back to reference Werring D, Clark C, Barker G et al (1999) Diffusion tensor imaging of lesions and normal-appearing white matter in multiple sclerosis. Neurology 52:1626–1632PubMed Werring D, Clark C, Barker G et al (1999) Diffusion tensor imaging of lesions and normal-appearing white matter in multiple sclerosis. Neurology 52:1626–1632PubMed
5.
go back to reference Tievsky A, Ptak T, Farkas J (1999) Investigation of apparent diffusion coefficient and diffusion tensor anisotropy in acute and chronic multiple sclerosis lesions. Am J Neuroradiol 20:1491–1499PubMed Tievsky A, Ptak T, Farkas J (1999) Investigation of apparent diffusion coefficient and diffusion tensor anisotropy in acute and chronic multiple sclerosis lesions. Am J Neuroradiol 20:1491–1499PubMed
6.
go back to reference Bammer R, Augustin M, Strasser-Fuchs S et al (2000) Magnetic resonance diffusion tensor imaging for characterizing diffuse and focal white matter abnormalities in multiple sclerosis. Magn Reson Med 44:583–591CrossRefPubMed Bammer R, Augustin M, Strasser-Fuchs S et al (2000) Magnetic resonance diffusion tensor imaging for characterizing diffuse and focal white matter abnormalities in multiple sclerosis. Magn Reson Med 44:583–591CrossRefPubMed
7.
go back to reference Sorensen A, Wu O, Copen W et al (1999) Human acute cerebral ischemia: detection of changes in water diffusion anisotropy by using MR imaging. Radiology 212:785–792PubMed Sorensen A, Wu O, Copen W et al (1999) Human acute cerebral ischemia: detection of changes in water diffusion anisotropy by using MR imaging. Radiology 212:785–792PubMed
8.
go back to reference Kunimatsu A, Aoki S, Masutani Y, Abe O, Mori H, Ohtomo K (2003) Three-dimensional white matter tractography by diffusion tensor imaging in ischaemic stroke involving the corticospinal tract. Neuroradiology 45:532–535CrossRefPubMed Kunimatsu A, Aoki S, Masutani Y, Abe O, Mori H, Ohtomo K (2003) Three-dimensional white matter tractography by diffusion tensor imaging in ischaemic stroke involving the corticospinal tract. Neuroradiology 45:532–535CrossRefPubMed
9.
go back to reference Abe O, Yamada H, Masutani Y, Aoki S, Kunimatsu A, Yamasue H, Fukuda R, Kasai K, Hayashi N, Masumoto T, Mori H, Soma T, Ohtomo K (2004) Amyotrophic lateral sclerosis: diffusion tensor tractography and voxel-based analysis. NMR Biomed 17:411–416CrossRefPubMed Abe O, Yamada H, Masutani Y, Aoki S, Kunimatsu A, Yamasue H, Fukuda R, Kasai K, Hayashi N, Masumoto T, Mori H, Soma T, Ohtomo K (2004) Amyotrophic lateral sclerosis: diffusion tensor tractography and voxel-based analysis. NMR Biomed 17:411–416CrossRefPubMed
10.
go back to reference Assaf BA, Mohamed FB, Abou-Khaled KJ, Williams JM, Yazeji MS, Haselgrove J, Faro SH (2003) Diffusion tensor imaging of the hippocampal formation in temporal lobe epilepsy. Am J Neuroradiol 24:1857–1862PubMed Assaf BA, Mohamed FB, Abou-Khaled KJ, Williams JM, Yazeji MS, Haselgrove J, Faro SH (2003) Diffusion tensor imaging of the hippocampal formation in temporal lobe epilepsy. Am J Neuroradiol 24:1857–1862PubMed
11.
go back to reference Basser PJ, Pajevic S, Pierpaoli C, Duda J, Aldroubi A (2000) In vivo fiber tractography using DT-MRI data. Magn Reson Med 44:625–632CrossRefPubMed Basser PJ, Pajevic S, Pierpaoli C, Duda J, Aldroubi A (2000) In vivo fiber tractography using DT-MRI data. Magn Reson Med 44:625–632CrossRefPubMed
12.
go back to reference Catani M, Howard RJ, Pajevic S, Jones DK (2002) Virtual in vivo interactive dissection of white matter fasciculi in the human brain. NeuroImage 17:77–94CrossRefPubMed Catani M, Howard RJ, Pajevic S, Jones DK (2002) Virtual in vivo interactive dissection of white matter fasciculi in the human brain. NeuroImage 17:77–94CrossRefPubMed
13.
go back to reference Naganawa S, Koshikawa T, Kawai H, Fukatsu H, Ishigaki T, Maruyama K, Takizawa O (2004) Optimization of diffusion-tensor MR imaging data acquisition parameters for brain fiber tracking using parallel imaging at 3 T. Eur Radiol 14:234–238CrossRefPubMed Naganawa S, Koshikawa T, Kawai H, Fukatsu H, Ishigaki T, Maruyama K, Takizawa O (2004) Optimization of diffusion-tensor MR imaging data acquisition parameters for brain fiber tracking using parallel imaging at 3 T. Eur Radiol 14:234–238CrossRefPubMed
14.
go back to reference Hagmann P, Thiran JP, Jonasson L, Vandergheynst P, Clarke S, Maeder P, Meuli R (2003) DTI mapping of human brain connectivity: statistical fibre tracking and virtual dissection. NeuroImage 19:545–554CrossRefPubMed Hagmann P, Thiran JP, Jonasson L, Vandergheynst P, Clarke S, Maeder P, Meuli R (2003) DTI mapping of human brain connectivity: statistical fibre tracking and virtual dissection. NeuroImage 19:545–554CrossRefPubMed
15.
go back to reference Papadakis NG, Xing D, Houston GC, Smith JM, Smith MI, James MF, Parsons AA, Huang CL, Hall LD, Carpenter TA (1999) A study of rotationally invariant and symmetric indices of diffusion anisotropy. Magn Reson Imaging 17:881–892CrossRefPubMed Papadakis NG, Xing D, Houston GC, Smith JM, Smith MI, James MF, Parsons AA, Huang CL, Hall LD, Carpenter TA (1999) A study of rotationally invariant and symmetric indices of diffusion anisotropy. Magn Reson Imaging 17:881–892CrossRefPubMed
16.
go back to reference Talairach J, Tournoux P (1988) Co-planar stereotaxic atlas of the human brain. Thieme, New York Talairach J, Tournoux P (1988) Co-planar stereotaxic atlas of the human brain. Thieme, New York
17.
go back to reference Ashburner J, Friston KJ (1999) Nonlinear spatial normalization using basis functions. Hum Brain Mapp 7:254–266CrossRefPubMed Ashburner J, Friston KJ (1999) Nonlinear spatial normalization using basis functions. Hum Brain Mapp 7:254–266CrossRefPubMed
18.
go back to reference Poline JB, Worsley KJ et al (1997) Combining spatial extent and peak intensity to test for activations in functional imaging. NeuroImage 5:83–96CrossRefPubMed Poline JB, Worsley KJ et al (1997) Combining spatial extent and peak intensity to test for activations in functional imaging. NeuroImage 5:83–96CrossRefPubMed
19.
go back to reference Bastin ME, Armitage PA, Marshall I (1998) A theoretical study of the effect of experimental noise on the measurement of anisotropy in diffusion imaging. Magn Reson Imaging 16:773–785CrossRefPubMed Bastin ME, Armitage PA, Marshall I (1998) A theoretical study of the effect of experimental noise on the measurement of anisotropy in diffusion imaging. Magn Reson Imaging 16:773–785CrossRefPubMed
Metadata
Title
Fractional anisotropy and mean diffusivity measurements on normal human brain: comparison between low- and high-resolution diffusion tensor imaging sequences
Publication date
01-01-2006
Published in
European Radiology / Issue 1/2006
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-2833-7

Other articles of this Issue 1/2006

European Radiology 1/2006 Go to the issue