Published in: European Radiology 5/2006

01-05-2006 | Neuro

Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results

Authors: Andrea Bink, Melanie Schmitt, Jochen Gaa, John P. Mugler 3rd, Heinrich Lanfermann, Friedhelm E. Zanella

Published in: European Radiology | Issue 5/2006

Login to get access

Abstract

The aim of this study was to compare conventional 2D FLAIR and single-slab 3D FLAIR sequences in the detection of lesions in patients with multiple sclerosis. Eight patients with MS were examined at 3.0 T by using a 2D FLAIR sequence and a single-slab 3D FLAIR sequence. A comparison of lesion detectability was performed for the following regions: periventricular, nonperiventricular/juxtacortical and infratentorial. The contrast-to-noise ratios (CNRs) between lesions and brain tissue and CSF were calculated for each sequence. A total of 424 lesions were found using the 2D FLAIR sequence, while with the 3D FLAIR sequence 719 lesions were found. With the 2D FLAIR sequence, 41% fewer lesions were detected than with the 3D FLAIR sequence. Further, 40% fewer supratentorial and 62.5% fewer infratentorial lesions were found with the 2D FLAIR sequence. In images acquired with the 3D FLAIR sequence, the lesions had significantly higher CNRs than in images acquired with the 2D FLAIR sequence. These are the first results using a single-slab 3D FLAIR sequence at 3.0 T for detection of lesions in patients with MS. With the 3D FLAIR sequence significantly higher CNRs were achieved and significantly more lesions in patients with MS were detected.
Literature
1.
go back to reference Hajnal JV, Bryant DJ, Kasuboski L, Pattany PM, De Coene B, Lewis PD et al (1992) Use of fluid attenuated inversion recovery (FLAIR) pulse sequences in MRI of the brain. J Comput Assist Tomogr 16:841–844PubMedCrossRef Hajnal JV, Bryant DJ, Kasuboski L, Pattany PM, De Coene B, Lewis PD et al (1992) Use of fluid attenuated inversion recovery (FLAIR) pulse sequences in MRI of the brain. J Comput Assist Tomogr 16:841–844PubMedCrossRef
2.
go back to reference De Coene B, Hajnal JV, Gatehouse P, Longmore DB, White SJ, Oatridge A et al (1992) MR of the brain using fluid-attenuated inversion recovery (FLAIR) pulse sequences. AJNR Am J Neuroradiol 13:1555–1564PubMed De Coene B, Hajnal JV, Gatehouse P, Longmore DB, White SJ, Oatridge A et al (1992) MR of the brain using fluid-attenuated inversion recovery (FLAIR) pulse sequences. AJNR Am J Neuroradiol 13:1555–1564PubMed
3.
go back to reference Tubridy N, Barker GJ, MacManus DG, Moseley IF, Miller DH (1998) Three-dimensional fast fluid attenuated inversion recovery (3D fast FLAIR):a new MRI sequence which increases the detectable cerebral lesion load in multiple sclerosis. Br J Radiol 71:840–845PubMed Tubridy N, Barker GJ, MacManus DG, Moseley IF, Miller DH (1998) Three-dimensional fast fluid attenuated inversion recovery (3D fast FLAIR):a new MRI sequence which increases the detectable cerebral lesion load in multiple sclerosis. Br J Radiol 71:840–845PubMed
4.
go back to reference Tan IL, Pouwels PJW, van Schijndel RA, Adèr HJ, Manoliu RA, Barkhof F (2002) Isotropic 3D fast FLAIR imaging of brain in multiple sclerosis patients: initial experience. Eur Radiol 12:559–567PubMed Tan IL, Pouwels PJW, van Schijndel RA, Adèr HJ, Manoliu RA, Barkhof F (2002) Isotropic 3D fast FLAIR imaging of brain in multiple sclerosis patients: initial experience. Eur Radiol 12:559–567PubMed
5.
go back to reference Tan IL, van Schijndel RA, Pouwels PJW, Adèr HJ, Barkhof F (2002) Serial isotropic three-dimensional fast FLAIR imaging: using image registration and subtraction to reveal active multiple sclerosis lesions. AJR Am J Roentgenol 179:777–782PubMed Tan IL, van Schijndel RA, Pouwels PJW, Adèr HJ, Barkhof F (2002) Serial isotropic three-dimensional fast FLAIR imaging: using image registration and subtraction to reveal active multiple sclerosis lesions. AJR Am J Roentgenol 179:777–782PubMed
6.
go back to reference Barker GJB (1998) 3D fast FLAIR: a CSF-nulled 3D fast spin-echo pulse sequence. Magn Reson Imaging 16:715–720CrossRefPubMed Barker GJB (1998) 3D fast FLAIR: a CSF-nulled 3D fast spin-echo pulse sequence. Magn Reson Imaging 16:715–720CrossRefPubMed
7.
go back to reference Mugler JP III, Bao S, Mulkern RV, Guttmann CRG, Robertson RL, Jolesz FA, Brookeman JR (2000) Optimized single-slab three-dimensional spin-echo MR imaging of the Brain. Radiology 216:891–899PubMed Mugler JP III, Bao S, Mulkern RV, Guttmann CRG, Robertson RL, Jolesz FA, Brookeman JR (2000) Optimized single-slab three-dimensional spin-echo MR imaging of the Brain. Radiology 216:891–899PubMed
8.
go back to reference Kallmes DF, Hui FK, Mugler JP III (2001) Suppression of cerebrospinal fluid and blood flow artifacts in FLAIR MR imaging with a single slab three-dimensional pulse sequence: initial experience. Radiology 221:251–255PubMedCrossRef Kallmes DF, Hui FK, Mugler JP III (2001) Suppression of cerebrospinal fluid and blood flow artifacts in FLAIR MR imaging with a single slab three-dimensional pulse sequence: initial experience. Radiology 221:251–255PubMedCrossRef
9.
go back to reference U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health. Guidance for the submission of premarket notifications for magnetic resonance diagnostic devices. Washington, DC: Nov. 14, 1998 U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health. Guidance for the submission of premarket notifications for magnetic resonance diagnostic devices. Washington, DC: Nov. 14, 1998
10.
go back to reference Schwindt W, Kugel H, Bachmann R, Allkemper T, Maintz D, Pfleiderer B, Tombach B, Heindel W (2003) Magnetic resonance imaging protocols for examination of the neurocranium at 3T. Eur Radiol 13:2170–2179CrossRefPubMed Schwindt W, Kugel H, Bachmann R, Allkemper T, Maintz D, Pfleiderer B, Tombach B, Heindel W (2003) Magnetic resonance imaging protocols for examination of the neurocranium at 3T. Eur Radiol 13:2170–2179CrossRefPubMed
11.
go back to reference Barkhof F, Filippi M, Miller DH et al (1997) Comparison of MRI at first presentation to predict conversion to clinically definite multiple sclerosis. Brain 120:2059–2069CrossRefPubMed Barkhof F, Filippi M, Miller DH et al (1997) Comparison of MRI at first presentation to predict conversion to clinically definite multiple sclerosis. Brain 120:2059–2069CrossRefPubMed
12.
go back to reference McDonald WI, Compston A, Edan G et al (2001) Recommended diagnostic criteria for multiple sclerosis: guidelines from the international panel on the diagnosis of multiple sclerosis. Ann Neurol 50:121–127CrossRefPubMed McDonald WI, Compston A, Edan G et al (2001) Recommended diagnostic criteria for multiple sclerosis: guidelines from the international panel on the diagnosis of multiple sclerosis. Ann Neurol 50:121–127CrossRefPubMed
13.
go back to reference Filippi M, Yousry T, Baratti C, Horsfield MA, Mammi S, Becker C et al (1996) Quantitative assessment of MRI lesion load in multiple sclerosis. A comparison of conventional spin-echo with fast fluid-attenuated inversion recovery. Brain 119:1349–1355PubMedCrossRef Filippi M, Yousry T, Baratti C, Horsfield MA, Mammi S, Becker C et al (1996) Quantitative assessment of MRI lesion load in multiple sclerosis. A comparison of conventional spin-echo with fast fluid-attenuated inversion recovery. Brain 119:1349–1355PubMedCrossRef
14.
go back to reference Bastianello S, Bozzao A, Paolillo A, Giugni E, Gasperini C, Koudriavtseva T et al (1997) Fast spin-echo and fast fluid-attenuated inversion-recovery versus conventional spin-echo sequences for MR quantification of multiple sclerosis lesions. AJNR Am J Neuroradiol 18:699–704PubMed Bastianello S, Bozzao A, Paolillo A, Giugni E, Gasperini C, Koudriavtseva T et al (1997) Fast spin-echo and fast fluid-attenuated inversion-recovery versus conventional spin-echo sequences for MR quantification of multiple sclerosis lesions. AJNR Am J Neuroradiol 18:699–704PubMed
15.
go back to reference Tubridy N, Barker GJ, MacManus DG, Moseley IF, Miller DH (1998) Optimisation of unenhanced MRI for detection of lesions in multiple sclerosis: a comparison of five pulse sequences with variable slice thickness. Neuroradiology 40:293–297CrossRefPubMed Tubridy N, Barker GJ, MacManus DG, Moseley IF, Miller DH (1998) Optimisation of unenhanced MRI for detection of lesions in multiple sclerosis: a comparison of five pulse sequences with variable slice thickness. Neuroradiology 40:293–297CrossRefPubMed
16.
go back to reference Herskovits EH, Itoh R, Melhem ER (2001) Accuracy for detection of simulated lesions: comparison of fluid-attenuated inversion-recovery, proton density-weighted, and T2-weighted synthetic brain MR imaging. AJR Am J Roentgenol 118:1313–1318 Herskovits EH, Itoh R, Melhem ER (2001) Accuracy for detection of simulated lesions: comparison of fluid-attenuated inversion-recovery, proton density-weighted, and T2-weighted synthetic brain MR imaging. AJR Am J Roentgenol 118:1313–1318
17.
go back to reference Melki PS, Mulkern RV (1992) Magnetization transfer effects in multislice RARE sequences. Magn Reson Med 24:189–195PubMedCrossRef Melki PS, Mulkern RV (1992) Magnetization transfer effects in multislice RARE sequences. Magn Reson Med 24:189–195PubMedCrossRef
18.
go back to reference Molyneux PD, Tubridy N, Parker GJM, Barker GJ, MacManus DG, Tofts PS et al (1998) The Effect of section thickness on MR lesion detection and quantification in multiple sclerosis. AJNR Am J Neuroradiol 19:1715–1720PubMed Molyneux PD, Tubridy N, Parker GJM, Barker GJ, MacManus DG, Tofts PS et al (1998) The Effect of section thickness on MR lesion detection and quantification in multiple sclerosis. AJNR Am J Neuroradiol 19:1715–1720PubMed
19.
go back to reference McGowan JC, Patel RS (2000) Technical issues of MRI examination of posterior fossa. J Neurol Sci 172:S20–S42 McGowan JC, Patel RS (2000) Technical issues of MRI examination of posterior fossa. J Neurol Sci 172:S20–S42
20.
go back to reference Stevenson VL, Parker GJM, Barker GJ, Birnie K, Tofts PS, Miller DH, Thompson AJ (2000) Variations in T1 and T2 relaxation times of normal appearing white matter and lesions in multiple sclerosis. J Neurol Sci 178:81–87CrossRefPubMed Stevenson VL, Parker GJM, Barker GJ, Birnie K, Tofts PS, Miller DH, Thompson AJ (2000) Variations in T1 and T2 relaxation times of normal appearing white matter and lesions in multiple sclerosis. J Neurol Sci 178:81–87CrossRefPubMed
21.
go back to reference Naganawa S, Koshikawa T, Nakamura T, Kawai H, Fukatsu H, Ishigaki T et al (2004) Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3 T. Eur Radiol 14:1901–1908PubMed Naganawa S, Koshikawa T, Nakamura T, Kawai H, Fukatsu H, Ishigaki T et al (2004) Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3 T. Eur Radiol 14:1901–1908PubMed
22.
go back to reference Lu H, Nagae-Poetscher LM, Golay X, Lin D, Pomper M, Zijl van PCM (2005) Routine clinical brain MRI sequences for use at 3.0 Tesla. J Magn Reson Imaging 22:13–22CrossRefPubMed Lu H, Nagae-Poetscher LM, Golay X, Lin D, Pomper M, Zijl van PCM (2005) Routine clinical brain MRI sequences for use at 3.0 Tesla. J Magn Reson Imaging 22:13–22CrossRefPubMed
23.
go back to reference Busse RF. Equivalent T2-contrast for fast spin echo sequences with low and variable flip refocusing. Proceedings of the International Society for Magnetic Resonance in Medicine 2344; 2005. Thirteenth Meeting, Miami Busse RF. Equivalent T2-contrast for fast spin echo sequences with low and variable flip refocusing. Proceedings of the International Society for Magnetic Resonance in Medicine 2344; 2005. Thirteenth Meeting, Miami
24.
go back to reference Papanikolaou N, Papadaki E, Karampekios S (2004) T2 relaxation time analysis in patients with multiple sclerosis: correlation with magnetization transfer ratio. Eur Radiol 14:115–122CrossRefPubMed Papanikolaou N, Papadaki E, Karampekios S (2004) T2 relaxation time analysis in patients with multiple sclerosis: correlation with magnetization transfer ratio. Eur Radiol 14:115–122CrossRefPubMed
Metadata
Title
Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results
Authors
Andrea Bink
Melanie Schmitt
Jochen Gaa
John P. Mugler 3rd
Heinrich Lanfermann
Friedhelm E. Zanella
Publication date
01-05-2006
Publisher
Springer-Verlag
Published in
European Radiology / Issue 5/2006
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-0107-z

Other articles of this Issue 5/2006

European Radiology 5/2006 Go to the issue