Skip to main content
Top
Published in: European Radiology 2/2005

01-02-2005 | Vascular-Interventional

Improved diagnosis of vascular dissection by ultrasound B-flow: a comparison with color-coded Doppler and power Doppler sonography

Authors: D.-A. Clevert, N. Rupp, M. Reiser, E. M. Jung

Published in: European Radiology | Issue 2/2005

Login to get access

Abstract

The purpose was to evaluate the diagnostic results of different ultrasound techniques: color-coded Doppler (CCD), power Doppler (PD) and B-flow in the diagnosis of vascular dissection. Findings from 68 patients with arterial dissection proven either by vascular ultrasound (US) or by magnetic resonance angiography (MRA), computed tomographic angiography (CTA) or intra-arterial digital subtraction angiography (DSA) were reviewed in retrospect. The study compared results from three different modes of ultrasound, i.e., CCD, PD and B-flow, in dissections of the carotid artery (n=11), of the vertebral artery (n=9), of the abdominal aorta (n=13), of the iliac artery (n=12) and of the femoral artery (n=23). MRA, CTA and DSA were considered as reference standard. The sensitivity of CCD for detecting all dissections was 78%, 84% for the PD and 98% for B-flow. For carotid artery dissection, the sensitivity of CCD, PD and B-flow was 82, 91 and 98%, for the vertebral artery 67, 78 and 98%, for the abdominal aorta 85, 85 and 98%, for the iliac artery 67, 75 and 98%, for the femoral artery 83, 87 and 98%, respectively. Intima flaps, fissures of membranes and residual flow within the true and false lumen were better detected by B-flow than by CCD and PD. The lack of angle dependence of the US probe in B-flow made the examination procedure easier. In the cine mode of B-flow, the pulse synchronic movement of the membrane was more apparent than in any other imaging method. With B-flow, accuracy for the diagnosis of arterial dissection is improved compared to CCD and PD. Flow within the true and false lumen, low-echo thrombi, intramural hematoma and even movements of the dissection membrane are clearly distinguished.
Literature
1.
go back to reference Koennecke HC, Trocio SH, Mast H, Mohr JP (1997) Microemboli on transcranial Doppler in patients with spontaneous carotid artery dissection. J Neuroimaging 7:217–220 Koennecke HC, Trocio SH, Mast H, Mohr JP (1997) Microemboli on transcranial Doppler in patients with spontaneous carotid artery dissection. J Neuroimaging 7:217–220
2.
go back to reference Murphy TP, Dorfman GS, Segall M, Carney WI Jr (1991) Iatrogenic arterial dissection: treatment by percutaneous transluminal angioplasty. Cardiovasc Intervent Radiol 14:302–306PubMed Murphy TP, Dorfman GS, Segall M, Carney WI Jr (1991) Iatrogenic arterial dissection: treatment by percutaneous transluminal angioplasty. Cardiovasc Intervent Radiol 14:302–306PubMed
3.
go back to reference De Bakey ME, McCollum CH, Crawford ES, Morris GC Jr, Howell J, Non GP, Lawrie G (1982) Dissection and dissecting aneurysms of the aorta: 20-year follow-up of 527 patients treated surgically. Surgery 92:118–134 De Bakey ME, McCollum CH, Crawford ES, Morris GC Jr, Howell J, Non GP, Lawrie G (1982) Dissection and dissecting aneurysms of the aorta: 20-year follow-up of 527 patients treated surgically. Surgery 92:118–134
4.
go back to reference Lu CJ, Sun Y, Jeng JS, Huang KM, Hwang BS, Lin BS, Lin WH, Chen RC, Yip PK (2000) Imaging in the diagnosis and follow-up evaluation of vertebral artery dissection. J Ultrasound Med 19:263–270PubMed Lu CJ, Sun Y, Jeng JS, Huang KM, Hwang BS, Lin BS, Lin WH, Chen RC, Yip PK (2000) Imaging in the diagnosis and follow-up evaluation of vertebral artery dissection. J Ultrasound Med 19:263–270PubMed
5.
go back to reference Akkersdijk WL, de Valois JC, Overtom TT, Moll FL (1994) Spontaneous dissection of iliac artery: treatment with a stent. Ned Tijdschr Geneeskd 138:1626–1628PubMed Akkersdijk WL, de Valois JC, Overtom TT, Moll FL (1994) Spontaneous dissection of iliac artery: treatment with a stent. Ned Tijdschr Geneeskd 138:1626–1628PubMed
6.
go back to reference Jung EM, Kubale R, Clevert D-A, Lutz R, Rupp N (2002) B-Flow und kontrastmittelverstärkter Power Mode mit Optison—präoperative Diagnostik der hochgradigen Stenose der A. carotis interna. Fortschr Röntgenstr 174:62–69CrossRef Jung EM, Kubale R, Clevert D-A, Lutz R, Rupp N (2002) B-Flow und kontrastmittelverstärkter Power Mode mit Optison—präoperative Diagnostik der hochgradigen Stenose der A. carotis interna. Fortschr Röntgenstr 174:62–69CrossRef
7.
8.
go back to reference Jung EM, Lutz R, Clevert D-A, Rupp N (2001) B-Flow—sonographische Beurteilung und Therapie femoraler Pseudoaneurysmen. Fortschr Röntgenstr 173:805–809CrossRef Jung EM, Lutz R, Clevert D-A, Rupp N (2001) B-Flow—sonographische Beurteilung und Therapie femoraler Pseudoaneurysmen. Fortschr Röntgenstr 173:805–809CrossRef
9.
go back to reference Jung EM, Kubale R, Clevert D-A, Rupp N (2003) Improved evaluation of stenoses of hemodialysis fistulas by B-flow ultrasound. Fortschr Röntgenstr 175:387–392CrossRef Jung EM, Kubale R, Clevert D-A, Rupp N (2003) Improved evaluation of stenoses of hemodialysis fistulas by B-flow ultrasound. Fortschr Röntgenstr 175:387–392CrossRef
10.
go back to reference Zhang Z, Berg MH, Ikonen AE, Vanninen RL, Manninen HI (2004) Cartoid artery stenosis: reproducibility of automated 3D CT angiography analysis method. Eur Radiol 14:665–672CrossRefPubMed Zhang Z, Berg MH, Ikonen AE, Vanninen RL, Manninen HI (2004) Cartoid artery stenosis: reproducibility of automated 3D CT angiography analysis method. Eur Radiol 14:665–672CrossRefPubMed
11.
go back to reference Trattnig S, Rand T, Thurnher M, Breitenseher M, Daha K (1995) Colour-coded Doppler sonography of common carotid artery dissection. Neuroradiology 37:124–126 Trattnig S, Rand T, Thurnher M, Breitenseher M, Daha K (1995) Colour-coded Doppler sonography of common carotid artery dissection. Neuroradiology 37:124–126
12.
go back to reference Risse JH, Vorwerk D, Speckamp F, Gunther RW (1995) Color-coded duplex ultrasound in chronic dissecting abdominal aortic aneurysma. Differentiation between true and false aortic lumen with reference to the blood supply to larger abdominal arteries. Radiologe 35:759–766PubMed Risse JH, Vorwerk D, Speckamp F, Gunther RW (1995) Color-coded duplex ultrasound in chronic dissecting abdominal aortic aneurysma. Differentiation between true and false aortic lumen with reference to the blood supply to larger abdominal arteries. Radiologe 35:759–766PubMed
Metadata
Title
Improved diagnosis of vascular dissection by ultrasound B-flow: a comparison with color-coded Doppler and power Doppler sonography
Authors
D.-A. Clevert
N. Rupp
M. Reiser
E. M. Jung
Publication date
01-02-2005
Publisher
Springer-Verlag
Published in
European Radiology / Issue 2/2005
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2481-3

Other articles of this Issue 2/2005

European Radiology 2/2005 Go to the issue

Letter to the Editor

The fibrocartilage sesamoid