Abstract

Magnetic resonance angiography (MRA) is a safe and non-invasive imaging method that can readily depict the pulmonary veins (PV), whose imaging has acquired momentum with the advent of new techniques for radiofrequency ablation of atrial fibrillation (AF). We evaluated whether virtual endoscopy from 3D MRA images (MRA-VE) is feasible in studying the morphology of PV. Fifty patients with AF underwent pre-ablative MRA (1.5 T). Images were acquired with axial T-2 weighted and 3D-SPGR sequences after intravenous administration of Gd-DTPA and automatic triggering. Postprocessing was performed by an experienced radiologist with maximum intensity projection (MIP) and virtual endoscopy software (Navigator, GEMS). The venoatrial junction was visualized with MRA-VE in 49 of 50 patients (98.0%). Twenty-seven patients (55.1%) had two ostia on both sides, 13 patients (26.5%) had two ostia on the right and a single common ostium on the left, 5 patients (10.2%) had accessory PV and 4 patients (8.2%) had both an accessory right PV and a single common ostium on the left. Flythrough navigation showed the number and spatial disposition of second-order PV branches in 48 out of 49 patients (98.0%). MRA-VE is an excellent tool for at-a-glance visualization of ostia morphology, navigation of second-generation PV branches and easy endoluminal assessment of left atrial structures in pre-ablative imaging.
Literature
1.
go back to reference Godart F, Cocheteux B, Willoteaux S et al (2002) Importance of magnetic resonance angiography with gadolinium injection in pulmonary vein diseases. Arch Mal Coeur Vaiss 95:433–437PubMed Godart F, Cocheteux B, Willoteaux S et al (2002) Importance of magnetic resonance angiography with gadolinium injection in pulmonary vein diseases. Arch Mal Coeur Vaiss 95:433–437PubMed
2.
go back to reference Wood MA, Wittkamp M, Henry D et al (2004) A comparison of pulmonary vein ostial anatomy by computerized tomography, echocardiography, and venography in patients with atrial fibrillation having radiofrequency catheter ablation. Am J Cardiol 93:49–53CrossRefPubMed Wood MA, Wittkamp M, Henry D et al (2004) A comparison of pulmonary vein ostial anatomy by computerized tomography, echocardiography, and venography in patients with atrial fibrillation having radiofrequency catheter ablation. Am J Cardiol 93:49–53CrossRefPubMed
3.
go back to reference Lacomis JM, Wigginton W, Fuhrman C, Schwartzman D, Armfield DR, Pealer KM (2003) Multi-detector row CT of the left atrium and pulmonary veins before radio-frequency catheter ablation for atrial fibrillation. Radiographics 23(Spec No):S35–S48 (discussion S48–S50)PubMed Lacomis JM, Wigginton W, Fuhrman C, Schwartzman D, Armfield DR, Pealer KM (2003) Multi-detector row CT of the left atrium and pulmonary veins before radio-frequency catheter ablation for atrial fibrillation. Radiographics 23(Spec No):S35–S48 (discussion S48–S50)PubMed
4.
go back to reference Maksimovic R, Cademartiri F, Scholten M, Jordaens LJ, Pattynama PM (2004) Sixteen-row multislice computed tomography in the assessment of pulmonary veins prior to ablative treatment: validation vs. conventional pulmonary venography and study of reproducibility. Eur Radiol 14:369–374CrossRefPubMed Maksimovic R, Cademartiri F, Scholten M, Jordaens LJ, Pattynama PM (2004) Sixteen-row multislice computed tomography in the assessment of pulmonary veins prior to ablative treatment: validation vs. conventional pulmonary venography and study of reproducibility. Eur Radiol 14:369–374CrossRefPubMed
5.
go back to reference Prince MR (1996) Body MR angiography with gadolinium contrast agents. Magn Reson Imaging Clin N Am 4:11–24PubMed Prince MR (1996) Body MR angiography with gadolinium contrast agents. Magn Reson Imaging Clin N Am 4:11–24PubMed
6.
go back to reference Ernst S, Broemel T, Krumsdorf U et al (2003) Three-dimensional reconstruction of pulmonary veins and left atrium. Implications for catheter ablation of atrial fibrillation. Herz 28:559–565PubMed Ernst S, Broemel T, Krumsdorf U et al (2003) Three-dimensional reconstruction of pulmonary veins and left atrium. Implications for catheter ablation of atrial fibrillation. Herz 28:559–565PubMed
7.
go back to reference Pilleul F, Merchant N (2000) MRI of the pulmonary veins: comparison between 3D MR angiography and T1-weighted spin echo. J Comput Assist Tomogr 24:683–687CrossRefPubMed Pilleul F, Merchant N (2000) MRI of the pulmonary veins: comparison between 3D MR angiography and T1-weighted spin echo. J Comput Assist Tomogr 24:683–687CrossRefPubMed
8.
go back to reference Hoffmann U, Schima W, Herold C (1999) Pulmonary magnetic resonance angiography. Eur Radiol 9:1745–1754CrossRefPubMed Hoffmann U, Schima W, Herold C (1999) Pulmonary magnetic resonance angiography. Eur Radiol 9:1745–1754CrossRefPubMed
9.
go back to reference Dill T, Neumann T, Ekinci O et al (2003) Pulmonary vein diameter reduction after radiofrequency catheter ablation for paroxysmal atrial fibrillation evaluated by contrast-enhanced three-dimensional magnetic resonance imaging. Circulation 107:845–850CrossRefPubMed Dill T, Neumann T, Ekinci O et al (2003) Pulmonary vein diameter reduction after radiofrequency catheter ablation for paroxysmal atrial fibrillation evaluated by contrast-enhanced three-dimensional magnetic resonance imaging. Circulation 107:845–850CrossRefPubMed
10.
go back to reference Wittkampf FH, Vonken EJ, Derksen R et al (2003) Pulmonary vein ostium geometry: analysis by magnetic resonance angiography. Circulation 107:21–23CrossRefPubMed Wittkampf FH, Vonken EJ, Derksen R et al (2003) Pulmonary vein ostium geometry: analysis by magnetic resonance angiography. Circulation 107:21–23CrossRefPubMed
11.
go back to reference Collins JD, Pereles FS, Bello D, Betts T, Song GK, Finn JP (2002) Pre-ablative pulmonary venous mapping by high-resolution MRA angiography facilitates electrophysiologic pulmonary vein ablation and reduces fluoroscopy time in patients with paroxysmal atrial fibrillation. RSNA Scientific Sessions, Chicago, p 473 Collins JD, Pereles FS, Bello D, Betts T, Song GK, Finn JP (2002) Pre-ablative pulmonary venous mapping by high-resolution MRA angiography facilitates electrophysiologic pulmonary vein ablation and reduces fluoroscopy time in patients with paroxysmal atrial fibrillation. RSNA Scientific Sessions, Chicago, p 473
12.
go back to reference Kato R, Lickfett L, Meininger G et al (2003) Pulmonary vein anatomy in patients undergoing catheter ablation of atrial fibrillation: lessons learned by use of magnetic resonance imaging. Circulation 107:2004–2010CrossRefPubMed Kato R, Lickfett L, Meininger G et al (2003) Pulmonary vein anatomy in patients undergoing catheter ablation of atrial fibrillation: lessons learned by use of magnetic resonance imaging. Circulation 107:2004–2010CrossRefPubMed
13.
go back to reference Yazar F, Ozdogmus O, Tuccar E, Bayramoglu A, Ozan H (2002) Drainage patterns of middle lobe vein of right lung: an anatomical study. Eur J Cardiothorac Surg 22:717–720CrossRefPubMed Yazar F, Ozdogmus O, Tuccar E, Bayramoglu A, Ozan H (2002) Drainage patterns of middle lobe vein of right lung: an anatomical study. Eur J Cardiothorac Surg 22:717–720CrossRefPubMed
14.
go back to reference Buthiau D, Antoine E, Piette JC, Nizri D, Baldeyrou P, Khayat D (1996) Virtual tracheo-bronchial endoscopy: educational and diagnostic value. Surg Radiol Anat 18:125–131PubMed Buthiau D, Antoine E, Piette JC, Nizri D, Baldeyrou P, Khayat D (1996) Virtual tracheo-bronchial endoscopy: educational and diagnostic value. Surg Radiol Anat 18:125–131PubMed
15.
go back to reference Wood BJ, Razavi P (2002) Virtual endoscopy: a promising new technology. Am Fam Physician 66:107–112PubMed Wood BJ, Razavi P (2002) Virtual endoscopy: a promising new technology. Am Fam Physician 66:107–112PubMed
16.
go back to reference World Medical Association Declaration of Helsinki (1964) Ethical principles for medical research involving human subjects. World Medical Association, Helsinki World Medical Association Declaration of Helsinki (1964) Ethical principles for medical research involving human subjects. World Medical Association, Helsinki
17.
go back to reference Foo TK, Saranathan M, Prince MR, Chenevert TL (1997) Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography. Radiology 203:275–280PubMed Foo TK, Saranathan M, Prince MR, Chenevert TL (1997) Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography. Radiology 203:275–280PubMed
18.
go back to reference Davis CP, Ladd ME, Romanowski BJ, Wildermuth S, Knoplioch JF, Debatin JF (1996) Human aorta: preliminary results with virtual endoscopy based on three-dimensional MR imaging data sets. Radiology 199:37–40PubMed Davis CP, Ladd ME, Romanowski BJ, Wildermuth S, Knoplioch JF, Debatin JF (1996) Human aorta: preliminary results with virtual endoscopy based on three-dimensional MR imaging data sets. Radiology 199:37–40PubMed
19.
go back to reference Ladd ME, Gohde SC, Steiner P, Pfammatter T, McKinnon GC, Debatin JF (1996) Virtual MR angioscopy of the pulmonary artery tree. J Comput Assist Tomogr 20:782–785CrossRefPubMed Ladd ME, Gohde SC, Steiner P, Pfammatter T, McKinnon GC, Debatin JF (1996) Virtual MR angioscopy of the pulmonary artery tree. J Comput Assist Tomogr 20:782–785CrossRefPubMed
20.
go back to reference Picard JD, Buthiau D (1999) Virtual endoscopy. Bull Acad Natl Med 183:465–475 (discussion 466–475)PubMed Picard JD, Buthiau D (1999) Virtual endoscopy. Bull Acad Natl Med 183:465–475 (discussion 466–475)PubMed
21.
go back to reference Fenlon HM, Nunes DP, Schroy PC III, Barish MA, Clarke PD, Ferrucci JT (1999) A comparison of virtual and conventional colonoscopy for the detection of colorectal polyps. N Engl J Med 341:1496–1503CrossRefPubMed Fenlon HM, Nunes DP, Schroy PC III, Barish MA, Clarke PD, Ferrucci JT (1999) A comparison of virtual and conventional colonoscopy for the detection of colorectal polyps. N Engl J Med 341:1496–1503CrossRefPubMed
22.
go back to reference Neri E, Caramella D, Bisogni C et al (1999) Detection of accessory renal arteries with virtual vascular endoscopy of the aorta. Cardiovasc Intervent Radiol 22:1–6CrossRefPubMed Neri E, Caramella D, Bisogni C et al (1999) Detection of accessory renal arteries with virtual vascular endoscopy of the aorta. Cardiovasc Intervent Radiol 22:1–6CrossRefPubMed
23.
go back to reference Lickfett L, Kato R, Berger R, Halperin H, Calkins H (2002) Magnetic resonance angiography and virtual endoscopic view of a left common pulmonary vein trunk. J Cardiovasc Electrophysiol 13:955CrossRefPubMed Lickfett L, Kato R, Berger R, Halperin H, Calkins H (2002) Magnetic resonance angiography and virtual endoscopic view of a left common pulmonary vein trunk. J Cardiovasc Electrophysiol 13:955CrossRefPubMed
24.
go back to reference Davis CP, Hany TF, Wildermuth S, Schmidt M, Debatin JF (1997) Postprocessing techniques for gadolinium-enhanced three-dimensional MR angiography. Radiographics 17:1061–1077PubMed Davis CP, Hany TF, Wildermuth S, Schmidt M, Debatin JF (1997) Postprocessing techniques for gadolinium-enhanced three-dimensional MR angiography. Radiographics 17:1061–1077PubMed
25.
go back to reference Moubarak JB, Rozwadowski JV, Strzalka CT et al (2000) Pulmonary veins—left atrial junction: anatomic and histological study. Pacing Clin Electrophysiol 23:1836–1838PubMed Moubarak JB, Rozwadowski JV, Strzalka CT et al (2000) Pulmonary veins—left atrial junction: anatomic and histological study. Pacing Clin Electrophysiol 23:1836–1838PubMed
26.
go back to reference Weiss C, Gocht A, Willems S, Hoffmann M, Risius T, Meinertz T (2002) Impact of the distribution and structure of myocardium in the pulmonary veins for radiofrequency ablation of atrial fibrillation. Pacing Clin Electrophysiol 25:1352–1356CrossRefPubMed Weiss C, Gocht A, Willems S, Hoffmann M, Risius T, Meinertz T (2002) Impact of the distribution and structure of myocardium in the pulmonary veins for radiofrequency ablation of atrial fibrillation. Pacing Clin Electrophysiol 25:1352–1356CrossRefPubMed
27.
go back to reference Ho SY, Sanchez-Quintana D, Cabrera JA, Anderson RH (1999) Anatomy of the left atrium: implications for radiofrequency ablation of atrial fibrillation. J Cardiovasc Electrophysiol 10:1525–1533PubMed Ho SY, Sanchez-Quintana D, Cabrera JA, Anderson RH (1999) Anatomy of the left atrium: implications for radiofrequency ablation of atrial fibrillation. J Cardiovasc Electrophysiol 10:1525–1533PubMed
28.
go back to reference Moak JP, Moore HJ, Lee SW et al (2000) Case report: pulmonary vein stenosis following RF ablation of paroxysmal atrial fibrillation: successful treatment with balloon dilation. J Interv Card Electrophysiol 4:621–631CrossRefPubMed Moak JP, Moore HJ, Lee SW et al (2000) Case report: pulmonary vein stenosis following RF ablation of paroxysmal atrial fibrillation: successful treatment with balloon dilation. J Interv Card Electrophysiol 4:621–631CrossRefPubMed
29.
go back to reference 1990 Recommendations of the International Commission on Radiological Protection (1991) ICRP Publication 60. Annals of ICRP 21 1990 Recommendations of the International Commission on Radiological Protection (1991) ICRP Publication 60. Annals of ICRP 21
Metadata
Title
Magnetic resonance angiography virtual endoscopy in the assessment of pulmonary veins before radiofrequency ablation procedures for atrial fibrillation
Authors
S. Cirillo
R. Bonamini
F. Gaita
Irene Tosetti
M. De Giuseppe
M. Longo
F. Bianchi
L. Vivalda
D. Regge
Publication date
01-11-2004
Publisher
Springer-Verlag
Published in
European Radiology / Issue 11/2004
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2406-1

Other articles of this Issue 11/2004

European Radiology 11/2004 Go to the issue