Virtual endoscopy of the tracheo-bronchial system: sub-millimeter collimation with the 16-row multidetector scanner

Authors: M. Fawad Khan, Christopher Herzog, Hanns Ackermann, Thomas O. F. Wagner, Adel Maataoui, Marc Harth, Nasreddin D. Abolmaali, Volkmar Jacobi, Thomas J. Vogl

Published in: European Radiology | Issue 8/2004

Login to get access

Abstract

The purpose of this study was to evaluate the scope of sub-millimeter collimation reconstruction parameters using 16-row computer tomography and ECG triggering on image quality in virtual bronchoscopy. Thirty-two patients (5 women, 27 men, mean age 66.6±1.4) who had been admitted for coronary artery bypass graft surgery underwent CT examination of the thorax (Sensation 16, Siemens, Inc., Forchheim, Germany). All patients were examined with 16×0.75-mm collimation. Image reconstruction was performed for two groups. In group A (n=32), slice thickness of 1.5 mm and an overlap of 0.75 mm were used. In group B (n=32), slice thickness of 0.75 mm and an overlap of 0.4 mm were applied. Retrospective ECG triggering was performed in all patients. The maximum order of recognizable bronchi was determined in each data set. In addition to assessing the maximum order of bronchial bifurcation, bronchial diameter was determined in truly perpendicular sections in each patient. For every segment proximal to a bifurcation, image quality was subjectively graded as poor (grade 1), moderate (grade 2) or good (grade 3). The observers were asked to identify the minimum cardiac movement ECG-triggered image sets assuming that they would be of better quality than the maximum cardiac movement ECG-triggered image sets. The Mann-Whitney U-test and the Fisher’s Exact Test were used for statistical evaluation. In group A, a mean of 4.8±0.2 bifurcations was ascertained vs. 6.5±0.3 bifurcations in group B [P<0.0003]. For bronchial diameters in group A, a mean of 7.5±0.4 mm was determined vs. 4.6±0.4 mm in group B [P<0.0001]. In group B, two independent radiologists observed a significant shift to better image quality in all segments evaluated [P<0.006 to P<0.000001]. Motion artifacts were judged as being significantly reduced by minimum cardiac movement ECG-triggering in group B [observer 1: P=0.0007 (20/32); observer 2: P=0.008 (18/32)], but not in group A [observer 1: P=0.286 (13/32); observer 2: P=0.123 (16/32)]. Sub-millimeter collimation and minimum cardiac movement ECG-triggered data acquisition allow deeper penetration into the tracheo-bronchial system allowing visualization of the bronchial surface down to diameters below 5 mm in certain cases up to the eighth bifurcation. Along with an enhanced visualization as such, better image quality is acquired in all segments evaluated. Trade off between better image quality, of doubtful diagnostic consequence, and much higher irradiation dose must be made.
Literature
1.
go back to reference Naidich DP, Lee JJ, Garay SM et al (1987) Comparison of CT and fiberoptic bronchoscopy in the evaluation of bronchial disease. Am J Roentgenol 148:1–7 Naidich DP, Lee JJ, Garay SM et al (1987) Comparison of CT and fiberoptic bronchoscopy in the evaluation of bronchial disease. Am J Roentgenol 148:1–7
2.
go back to reference Henschke CI, Davis SD, Romando AP et al (1987) Detection of bronchial abnormalities: comparison of CT and bronchoscopy. J Comput Assist Tomogr 11:432–435PubMed Henschke CI, Davis SD, Romando AP et al (1987) Detection of bronchial abnormalities: comparison of CT and bronchoscopy. J Comput Assist Tomogr 11:432–435PubMed
3.
go back to reference Naidich DP, Harkin TJ (1995) Airways and lung correlation of CT with fiberoptic bronchoscopy. Radiology 197:1–12 Naidich DP, Harkin TJ (1995) Airways and lung correlation of CT with fiberoptic bronchoscopy. Radiology 197:1–12
4.
go back to reference McAdams HP, Palmer SM, Erasmus JJ et al (1998) Bronchial anastomotic complications in lung transplant recipients: virtual bronchoscopy for noninvasive assessment. Radiology 209:689–695PubMed McAdams HP, Palmer SM, Erasmus JJ et al (1998) Bronchial anastomotic complications in lung transplant recipients: virtual bronchoscopy for noninvasive assessment. Radiology 209:689–695PubMed
5.
go back to reference McAdams HP, Goodman PC, Kussin P (1998) Virtual bronchoscopy for directing transbronchial needle aspiration of hilar and mediastinal lymph nodes: a pilot study. Am J Roentgenol 170:1361–1364 McAdams HP, Goodman PC, Kussin P (1998) Virtual bronchoscopy for directing transbronchial needle aspiration of hilar and mediastinal lymph nodes: a pilot study. Am J Roentgenol 170:1361–1364
6.
go back to reference Morrin MM, LaMont JT (2003) Screening virtual colonoscopy—ready for prime time? N Engl J Med 349:2191–2200CrossRefPubMed Morrin MM, LaMont JT (2003) Screening virtual colonoscopy—ready for prime time? N Engl J Med 349:2191–2200CrossRefPubMed
7.
go back to reference Kay CL, Evangelou HA (1996) A review of the technical and clinical aspects of virtual endoscopy. Endoscopy 28:768–775PubMed Kay CL, Evangelou HA (1996) A review of the technical and clinical aspects of virtual endoscopy. Endoscopy 28:768–775PubMed
8.
go back to reference Vining DJ, Liu K, Choplin RH (1996) Virtual bronchoscopy: relationship of virtual reality endobronchial simulations to actual bronchoscopic findings. Chest 109:549–553PubMed Vining DJ, Liu K, Choplin RH (1996) Virtual bronchoscopy: relationship of virtual reality endobronchial simulations to actual bronchoscopic findings. Chest 109:549–553PubMed
9.
go back to reference Hoppe H, Dinkel HP, Walder B, Von Allmen G, Gugger M, Vock P (2004) Grading airway stenosis down to the segmental level using virtual bronchoscopy. Chest 125:704–711CrossRefPubMed Hoppe H, Dinkel HP, Walder B, Von Allmen G, Gugger M, Vock P (2004) Grading airway stenosis down to the segmental level using virtual bronchoscopy. Chest 125:704–711CrossRefPubMed
10.
go back to reference Finkelstein SE, Schrump DS, Nguyen DM, Hewitt SM, Kunst TF, Summers RM (2003) Comparative evaluation of super high-resolution CT scan and virtual bronchoscopy for the detection of tracheobronchial malignancies. Chest 124:1834–1840CrossRefPubMed Finkelstein SE, Schrump DS, Nguyen DM, Hewitt SM, Kunst TF, Summers RM (2003) Comparative evaluation of super high-resolution CT scan and virtual bronchoscopy for the detection of tracheobronchial malignancies. Chest 124:1834–1840CrossRefPubMed
11.
go back to reference Summers RH, Feng DH, Holland SM (1996) Virtual bronchoscopy: segmentation method for real-time display. Radiology 199:321–330PubMed Summers RH, Feng DH, Holland SM (1996) Virtual bronchoscopy: segmentation method for real-time display. Radiology 199:321–330PubMed
12.
go back to reference Kalender WA (2003) Computed tomography. Publicis MCD, Munich, p 110 Kalender WA (2003) Computed tomography. Publicis MCD, Munich, p 110
13.
go back to reference Neumann K, Winterer J, Kimmig M et al (2000) Real-time interactive virtual endoscopy of the tracheo-bronchial system: influence of CT imaging protocols and observer ability. Eur J Radiol 33:50–54CrossRefPubMed Neumann K, Winterer J, Kimmig M et al (2000) Real-time interactive virtual endoscopy of the tracheo-bronchial system: influence of CT imaging protocols and observer ability. Eur J Radiol 33:50–54CrossRefPubMed
14.
go back to reference Herzog C, Abolmaali N, Balzer JO et al (2002) Heart-rate adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678PubMed Herzog C, Abolmaali N, Balzer JO et al (2002) Heart-rate adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678PubMed
15.
go back to reference Costello P (1994) Spiral CT of the thorax. Semin Ultrasound CT MR 15:90–106PubMed Costello P (1994) Spiral CT of the thorax. Semin Ultrasound CT MR 15:90–106PubMed
16.
go back to reference Fleiter T, Merkle EM, Aschoff AJ, Lang G, Stein M, Gorich J, Liewald F, Rilinger N, Sokiranski R (1997) Comparison of real-time virtual and fiberoptic bronchoscopy in patients with bronchial carcinoma: opportunities and limitations. Am J Roentgenol 169:1591–1595PubMed Fleiter T, Merkle EM, Aschoff AJ, Lang G, Stein M, Gorich J, Liewald F, Rilinger N, Sokiranski R (1997) Comparison of real-time virtual and fiberoptic bronchoscopy in patients with bronchial carcinoma: opportunities and limitations. Am J Roentgenol 169:1591–1595PubMed
17.
go back to reference Rubin GD, Beaulieu CF, Argiro V et al (1996) Perspective volume rendering of CT and MR images: applications for endoscopic imaging. Radiology 199:321–330PubMed Rubin GD, Beaulieu CF, Argiro V et al (1996) Perspective volume rendering of CT and MR images: applications for endoscopic imaging. Radiology 199:321–330PubMed
18.
go back to reference Schaefer-Prokop C, Prokop M (2002) New imaging techniques in the treatment guidelines for lung cancer. Eur Respir J [Suppl] 35:71s–83sPubMed Schaefer-Prokop C, Prokop M (2002) New imaging techniques in the treatment guidelines for lung cancer. Eur Respir J [Suppl] 35:71s–83sPubMed
19.
go back to reference Schoepf UJ, Holzknecht N, Helmberger TK et al (2002) Subsegmental pulmonary emboli: improved detection with thin-collimation multi-detector row spiral CT. Radiology 222:483–490PubMed Schoepf UJ, Holzknecht N, Helmberger TK et al (2002) Subsegmental pulmonary emboli: improved detection with thin-collimation multi-detector row spiral CT. Radiology 222:483–490PubMed
20.
go back to reference Schoepf UJ, Becker CR, Obuchowski NA et al (2001) Multi-slice computed tomography as a screening tool for colon cancer, lung cancer, and coronary artery disease. Eur Radiol 11:1975–1985CrossRefPubMed Schoepf UJ, Becker CR, Obuchowski NA et al (2001) Multi-slice computed tomography as a screening tool for colon cancer, lung cancer, and coronary artery disease. Eur Radiol 11:1975–1985CrossRefPubMed
21.
go back to reference Schoepf UJ, Becker C, Brüning R et al (1999) Computertomographie des Abdomens mit der Mehrzeilen-Detektor Spiral CT (Computed tomography of the abdomen with multidetector-array CT). Radiologe 39:652–661PubMed Schoepf UJ, Becker C, Brüning R et al (1999) Computertomographie des Abdomens mit der Mehrzeilen-Detektor Spiral CT (Computed tomography of the abdomen with multidetector-array CT). Radiologe 39:652–661PubMed
22.
go back to reference Summers RM, Shaw DJ, Shelhamer JH (1998) CT virtual bronchoscopy of simulated endobronchial lesions: effect of scanning, reconstruction, and display settings and potential pitfalls. Am J Roentgenol 170:947–950 Summers RM, Shaw DJ, Shelhamer JH (1998) CT virtual bronchoscopy of simulated endobronchial lesions: effect of scanning, reconstruction, and display settings and potential pitfalls. Am J Roentgenol 170:947–950
23.
go back to reference Rubin GD (1996) Techniques of reconstruction. In: Remy Jardin M, Remy J (eds) Medical radiology spiral CT of the chest. Springer, Berlin Heidelberg New York, pp 101–127 Rubin GD (1996) Techniques of reconstruction. In: Remy Jardin M, Remy J (eds) Medical radiology spiral CT of the chest. Springer, Berlin Heidelberg New York, pp 101–127
24.
go back to reference Ferretti GR, Bricault I, Coulomb M (2001) Virtual tools of the thorax. Eur Respir J 18:381–392PubMed Ferretti GR, Bricault I, Coulomb M (2001) Virtual tools of the thorax. Eur Respir J 18:381–392PubMed
25.
go back to reference Schwarz Y, Mehta AC, Ernst A, Herth F, Engel A, Besser D, Becker HD (2003) Electromagnetic navigation during flexible bronchoscopy. Respiration 70:516–522CrossRefPubMed Schwarz Y, Mehta AC, Ernst A, Herth F, Engel A, Besser D, Becker HD (2003) Electromagnetic navigation during flexible bronchoscopy. Respiration 70:516–522CrossRefPubMed
Metadata
Title
Virtual endoscopy of the tracheo-bronchial system: sub-millimeter collimation with the 16-row multidetector scanner
Authors
M. Fawad Khan
Christopher Herzog
Hanns Ackermann
Thomas O. F. Wagner
Adel Maataoui
Marc Harth
Nasreddin D. Abolmaali
Volkmar Jacobi
Thomas J. Vogl
Publication date
01-08-2004
Publisher
Springer-Verlag
Published in
European Radiology / Issue 8/2004
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2325-1

Other articles of this Issue 8/2004

European Radiology 8/2004 Go to the issue