Abstract

Purpose

Cone-beam computed tomography (CBCT) is an imaging technique, first developed for use during oral and pre-implant surgery. In sinonasal surgery, CBCT might represent a valuable tool for anatomical research given its high spatial resolution and low irradiation dose. However, clinical and anatomical evidence pertaining to its efficacy is lacking. This study assessed the morphological concordance between CBCT and multislice detector computed tomography (MDCT) in the context of sinonasal anatomy.

Methods

We performed an anatomical study using 15 fresh cadaver heads. Each head underwent both CBCT and MDCT. Two independent reviewers evaluated 26 notable anatomical landmarks. The primary outcome was the overall morphological concordance between the two imaging techniques. Secondary objectives included assessment of inter-rater agreement and comparison of the radiation doses received by different parts of the anatomy.

Results

Overall morphological concordance between the two imaging techniques was excellent (>98 %); the inter-rater agreement for CBCT was approximately 97 %, which is highly similar to MDCT, but achieved using a significantly decreased irradiation dose.

Conclusion

Our preliminary study indicates that CBCT represents a valid, reproducible, and safe technique for the identification of relevant sinonasal anatomical structures. Further research, particularly in pathological contexts, is required.
Literature
1.
go back to reference Alspaugh J, Goodsitt M (2007) Dose and image quality of flat-panel detector volume computed tomography for sinus imaging. Madison WI Med Phys 34:26–30 Alspaugh J, Goodsitt M (2007) Dose and image quality of flat-panel detector volume computed tomography for sinus imaging. Madison WI Med Phys 34:26–30
2.
go back to reference Bremke M, Sesterhenn AM, Murthum T, Hail Al A, Bien S, Werner JA (2009) Digital volume tomography (DVT) as a diagnostic modality of the anterior skull base. Acta Otolaryngol 129:1106–1114CrossRefPubMed Bremke M, Sesterhenn AM, Murthum T, Hail Al A, Bien S, Werner JA (2009) Digital volume tomography (DVT) as a diagnostic modality of the anterior skull base. Acta Otolaryngol 129:1106–1114CrossRefPubMed
3.
go back to reference Dahmani-Causse M, Marx M, Deguine O, Fraysse B, Lepage B, Escudé B (2011) Morphologic examination of the temporal bone by cone beam computed tomography: comparison with multislice helical computed tomography. Eur Ann Otorhinolaryngol Head Neck Dis 128:230–235CrossRefPubMed Dahmani-Causse M, Marx M, Deguine O, Fraysse B, Lepage B, Escudé B (2011) Morphologic examination of the temporal bone by cone beam computed tomography: comparison with multislice helical computed tomography. Eur Ann Otorhinolaryngol Head Neck Dis 128:230–235CrossRefPubMed
4.
go back to reference DelGaudio JM, Hudgins PA, Venkatraman G, Beningfield A (2005) Multiplanar computed tomographic analysis of frontal recess cells: effect on frontal isthmus size and frontal sinusitis. Arch Otolaryngol Head Neck Surg 131:230–235CrossRefPubMed DelGaudio JM, Hudgins PA, Venkatraman G, Beningfield A (2005) Multiplanar computed tomographic analysis of frontal recess cells: effect on frontal isthmus size and frontal sinusitis. Arch Otolaryngol Head Neck Surg 131:230–235CrossRefPubMed
5.
go back to reference Georgel T, Jankowski R, Henrot P, Baumann C, Kacha S, Grignon B et al (2009) CT assessment of woodworkers’ nasal adenocarcinomas confirms the origin in the olfactory cleft. AJNR Am J Neuroradiol 30:1440–1444CrossRefPubMed Georgel T, Jankowski R, Henrot P, Baumann C, Kacha S, Grignon B et al (2009) CT assessment of woodworkers’ nasal adenocarcinomas confirms the origin in the olfactory cleft. AJNR Am J Neuroradiol 30:1440–1444CrossRefPubMed
6.
go back to reference Grignon B, Mainard L, Delion M, Hodez C, Oldrini G (2012) Recent advances in medical imaging: anatomical and clinical applications. Surg Radiol Anat 34:675–686CrossRefPubMed Grignon B, Mainard L, Delion M, Hodez C, Oldrini G (2012) Recent advances in medical imaging: anatomical and clinical applications. Surg Radiol Anat 34:675–686CrossRefPubMed
7.
go back to reference Güldner C, Diogo I, Windfuhr J, Bien S, Teymoortash A, Werner JA et al (2011) Analysis of the fossa olfactoria using cone beam tomography (CBT). Acta Otolaryngol 131:72–78CrossRefPubMed Güldner C, Diogo I, Windfuhr J, Bien S, Teymoortash A, Werner JA et al (2011) Analysis of the fossa olfactoria using cone beam tomography (CBT). Acta Otolaryngol 131:72–78CrossRefPubMed
8.
go back to reference Jankowski R, Russel A, Gallet P, Henrot P, Vignaud JM, Nguyen DT (2015) Olfactory neuroblastoma behavior inside and outside the olfactory cleft. Surg Radiol Anat 37:507–515CrossRefPubMed Jankowski R, Russel A, Gallet P, Henrot P, Vignaud JM, Nguyen DT (2015) Olfactory neuroblastoma behavior inside and outside the olfactory cleft. Surg Radiol Anat 37:507–515CrossRefPubMed
9.
go back to reference Keros P (1962) On the practical value of differences in the level of the lamina cribrosa of the ethmoid. Z Laryngol Rhinol Otol 41:809–813PubMed Keros P (1962) On the practical value of differences in the level of the lamina cribrosa of the ethmoid. Z Laryngol Rhinol Otol 41:809–813PubMed
10.
go back to reference Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed
11.
go back to reference Liang X, Jacobs R, Hassan B, Li L, Pauwels R, Corpas L et al (2010) A comparative evaluation of cone beam computed tomography (CBCT) and multi-slice CT (MSCT) part I. On subjective image quality. Eur J Radiol 75:265–269CrossRefPubMed Liang X, Jacobs R, Hassan B, Li L, Pauwels R, Corpas L et al (2010) A comparative evaluation of cone beam computed tomography (CBCT) and multi-slice CT (MSCT) part I. On subjective image quality. Eur J Radiol 75:265–269CrossRefPubMed
12.
go back to reference Lofthag-Hansen S, Gröndahl K, Ekestubbe A (2009) Cone-beam CT for preoperative implant planning in the posterior mandible: visibility of anatomic landmarks. Clin Implant Dent Relat Res 11:246–255CrossRefPubMed Lofthag-Hansen S, Gröndahl K, Ekestubbe A (2009) Cone-beam CT for preoperative implant planning in the posterior mandible: visibility of anatomic landmarks. Clin Implant Dent Relat Res 11:246–255CrossRefPubMed
13.
go back to reference Meloni F, Mini R, Rovasio S, Stomeo F, Teatini GP (1992) Anatomic variations of surgical importance in ethmoid labyrinth and sphenoid sinus. A study of radiological anatomy. Surg Radiol Anat 14:65–70CrossRefPubMed Meloni F, Mini R, Rovasio S, Stomeo F, Teatini GP (1992) Anatomic variations of surgical importance in ethmoid labyrinth and sphenoid sinus. A study of radiological anatomy. Surg Radiol Anat 14:65–70CrossRefPubMed
14.
go back to reference Peltonen LI, Aarnisalo AA, Käser Y, Kortesniemi MK, Robinson S, Suomalainen A et al (2009) Cone-beam computed tomography: a new method for imaging of the temporal bone. Acta Radiol 50:543–548CrossRefPubMed Peltonen LI, Aarnisalo AA, Käser Y, Kortesniemi MK, Robinson S, Suomalainen A et al (2009) Cone-beam computed tomography: a new method for imaging of the temporal bone. Acta Radiol 50:543–548CrossRefPubMed
15.
go back to reference Rusu MC, Didilescu AC, Jianu AM, Păduraru D (2013) 3D CBCT anatomy of the pterygopalatine fossa. Surg Radiol Anat 35:143–159PubMed Rusu MC, Didilescu AC, Jianu AM, Păduraru D (2013) 3D CBCT anatomy of the pterygopalatine fossa. Surg Radiol Anat 35:143–159PubMed
16.
go back to reference Savvateeva DM, Güldner C, Murthum T, Bien S, Teymoortash A, Werner JA et al (2010) Digital volume tomography (DVT) measurements of the olfactory cleft and olfactory fossa. Acta Otolaryngol 130:398–404CrossRefPubMed Savvateeva DM, Güldner C, Murthum T, Bien S, Teymoortash A, Werner JA et al (2010) Digital volume tomography (DVT) measurements of the olfactory cleft and olfactory fossa. Acta Otolaryngol 130:398–404CrossRefPubMed
17.
go back to reference Scarfe WC, Farman AG (2008) What is cone-beam CT and how does it work? Dent Clin North Am 52:707–730CrossRefPubMed Scarfe WC, Farman AG (2008) What is cone-beam CT and how does it work? Dent Clin North Am 52:707–730CrossRefPubMed
18.
go back to reference Vaid S, Vaid N, Rawat S, Ahuja AT (2011) An imaging checklist for pre-FESS CT: framing a surgically relevant report. Clin Radiol 66:459–470CrossRefPubMed Vaid S, Vaid N, Rawat S, Ahuja AT (2011) An imaging checklist for pre-FESS CT: framing a surgically relevant report. Clin Radiol 66:459–470CrossRefPubMed
19.
go back to reference Zoumalan RA, Lebowitz RA, Wang E, Yung K, Babb JS, Jacobs JB (2009) Flat panel cone beam computed tomography of the sinuses. Otolaryngol Head Neck Surg 140:841–844CrossRefPubMed Zoumalan RA, Lebowitz RA, Wang E, Yung K, Babb JS, Jacobs JB (2009) Flat panel cone beam computed tomography of the sinuses. Otolaryngol Head Neck Surg 140:841–844CrossRefPubMed
Metadata
Title
Morphological concordance between CBCT and MDCT: a paranasal sinus-imaging anatomical study
Authors
J. Demeslay
S. Vergez
E. Serrano
P. Chaynes
P. Cantet
B. Chaput
G. de Bonnecaze
Publication date
01-01-2016
Publisher
Springer Paris
Published in
Surgical and Radiologic Anatomy / Issue 1/2016
Print ISSN: 0930-1038
Electronic ISSN: 1279-8517
DOI
https://doi.org/10.1007/s00276-015-1509-5

Other articles of this Issue 1/2016

Surgical and Radiologic Anatomy 1/2016 Go to the issue