Purpose

The purpose of this study was to determine, during anterior plating of the distal radius, the length of a screw above which there is a risk for the extensor tendons and the optimal shape of an anterior plate. It was also to determine the projection of the axis of the distal third of the radius on the distal articular surface in case of wrist arthroplasty in order to simplify the procedure.

Methods

We studied 74 dry radii from adult cadavers. Each one underwent a CT scan. We measured the thickness of each radius at the dorsal tubercle level, at the second compartment level and at the third compartment level. We calculated the metaphyseal–epiphyseal angles of the lateral column and of the intermediate column (Rikli and Regazzoni in J Bone Joint Surg (Br) 78(4):588–592, 1996). We also calculated the projection of the longitudinal axis of the most distal 7 cm of the radius on the distal carpal surface of the radius.

Results

Mean thickness at the dorsal tubercle level was 22.1 mm (18–26.1). The mean slope of the lateral column was 155° (143–167) while that of the intermediate column was 145° (134–153). We have found a statistically significant difference (p < 0.0001) between these two slopes. The axis of the distal radius was projected on the posterior-lateral quadrant of the distal articular surface.

Conclusions

The emergence of new implants needs a precise evaluation of a fractured, an arthritic or a reconstructed distal radius. The double slope of the distal radius complicates the manufacturing of an “anatomical” plate. The optimal shape is between these two slopes. Moreover, ancillaries for wrist replacement are still approximations, which means that it is important to know the projection of the radial axis on the articular surface of the distal radius.
Literature
1.
go back to reference Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21(5):316–322PubMedCrossRef Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21(5):316–322PubMedCrossRef
2.
go back to reference Benson EC, DeCarvalho A, Mikola EA, Veitch JM, Moneim MS (2006) Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res 451:218–222PubMedCrossRef Benson EC, DeCarvalho A, Mikola EA, Veitch JM, Moneim MS (2006) Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res 451:218–222PubMedCrossRef
3.
go back to reference Buzzell JE, Weikert DR, Watson JT, Lee DH (2008) Precontoured fixed-angle volar distal radius plates: a comparison of anatomic fit. J Hand Surg Am 33(7):1144–1152PubMedCrossRef Buzzell JE, Weikert DR, Watson JT, Lee DH (2008) Precontoured fixed-angle volar distal radius plates: a comparison of anatomic fit. J Hand Surg Am 33(7):1144–1152PubMedCrossRef
4.
go back to reference Chen NC, Jupiter JB (2007) Management of distal radial fractures. J Bone Joint Surg Am 89(9):2051–2062PubMedCrossRef Chen NC, Jupiter JB (2007) Management of distal radial fractures. J Bone Joint Surg Am 89(9):2051–2062PubMedCrossRef
5.
go back to reference Clement H, Pichler W, Nelson D, Hausleitner L, Tesch NP, Grechenig W (2008) Morphometric analysis of Lister’s tubercle and its consequences on volar plate fixation of distal radius fractures. J Hand Surg Am 33(10):1716–1719PubMedCrossRef Clement H, Pichler W, Nelson D, Hausleitner L, Tesch NP, Grechenig W (2008) Morphometric analysis of Lister’s tubercle and its consequences on volar plate fixation of distal radius fractures. J Hand Surg Am 33(10):1716–1719PubMedCrossRef
6.
go back to reference Constantine KJ, Clawson MC, Stern PJ (2002) Volar neutralization plate fixation of dorsally displaced distal radius fractures. Orthopedics 25(2):125–128PubMed Constantine KJ, Clawson MC, Stern PJ (2002) Volar neutralization plate fixation of dorsally displaced distal radius fractures. Orthopedics 25(2):125–128PubMed
7.
go back to reference Drobetz H, Bryant AL, Pokorny T, Spitaler R, Leixnering M, Jupiter JB (2006) Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction–a biomechanical study in a cadaveric model. J Hand Surg Am 31(4):615–622PubMedCrossRef Drobetz H, Bryant AL, Pokorny T, Spitaler R, Leixnering M, Jupiter JB (2006) Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction–a biomechanical study in a cadaveric model. J Hand Surg Am 31(4):615–622PubMedCrossRef
8.
go back to reference Drobetz H, Kutscha-Lissberg E (2003) Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 27(1):1–6PubMed Drobetz H, Kutscha-Lissberg E (2003) Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 27(1):1–6PubMed
9.
go back to reference Facca S, Gherissi A, Liverneaux PA (2010) Contribution of computer-assisted surgery in total wrist prosthesis: a comparative preliminary study of eight cases. Int J Med Robot 6(2):136–141PubMed Facca S, Gherissi A, Liverneaux PA (2010) Contribution of computer-assisted surgery in total wrist prosthesis: a comparative preliminary study of eight cases. Int J Med Robot 6(2):136–141PubMed
10.
go back to reference Failla JM, Koniuch MP, Moed BR (1993) Extensor pollicis longus rupture at the tip of a prominent fixation screw: report of three cases. J Hand Surg Am 18(4):648–651PubMedCrossRef Failla JM, Koniuch MP, Moed BR (1993) Extensor pollicis longus rupture at the tip of a prominent fixation screw: report of three cases. J Hand Surg Am 18(4):648–651PubMedCrossRef
11.
go back to reference Fourastier J, Le Breton L, Alnot Y, Langlais F, Condamine JL, Pidhorz L (1996) Guepar’s total radio-carpal prosthesis in the surgery of the rheumatoid wrist. Apropos of 72 cases reviewed. Rev Chir Orthop Reparatrice Appar Mot 82(2):108–115PubMed Fourastier J, Le Breton L, Alnot Y, Langlais F, Condamine JL, Pidhorz L (1996) Guepar’s total radio-carpal prosthesis in the surgery of the rheumatoid wrist. Apropos of 72 cases reviewed. Rev Chir Orthop Reparatrice Appar Mot 82(2):108–115PubMed
12.
go back to reference Gruber G, Bernhardt GA, Kohler G, Gruber K (2006) Surgical treatment of distal radius fractures with an angle fixed bar palmar plating system: a single center study of 102 patients over a 2-year period. Arch Orthop Trauma Surg 126(10):680–685PubMedCrossRef Gruber G, Bernhardt GA, Kohler G, Gruber K (2006) Surgical treatment of distal radius fractures with an angle fixed bar palmar plating system: a single center study of 102 patients over a 2-year period. Arch Orthop Trauma Surg 126(10):680–685PubMedCrossRef
13.
go back to reference Herzberg G, Garret J, Erhard L (1998) The anatomy of the distal radius. Cahiers d’enseignement de la SOFCOT 67:1–13 Herzberg G, Garret J, Erhard L (1998) The anatomy of the distal radius. Cahiers d’enseignement de la SOFCOT 67:1–13
14.
go back to reference Margaliot Z, Haase SC, Kotsis SV, Kim HM, Chung KC (2005) A meta-analysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures. J Hand Surg Am 30(6):1185–1199PubMedCrossRef Margaliot Z, Haase SC, Kotsis SV, Kim HM, Chung KC (2005) A meta-analysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures. J Hand Surg Am 30(6):1185–1199PubMedCrossRef
15.
go back to reference McQueen M, Caspers J (1988) Colles’ fracture: does the anatomical result affect the final function? J Bone Joint Surg Br 70(4):649–651PubMed McQueen M, Caspers J (1988) Colles’ fracture: does the anatomical result affect the final function? J Bone Joint Surg Br 70(4):649–651PubMed
16.
go back to reference Murphy DM, Khoury JG, Imbriglia JE, Adams BD (2003) Comparison of arthroplasty and arthrodesis for the rheumatoid wrist. J Hand Surg Am 28(5):570–576PubMedCrossRef Murphy DM, Khoury JG, Imbriglia JE, Adams BD (2003) Comparison of arthroplasty and arthrodesis for the rheumatoid wrist. J Hand Surg Am 28(5):570–576PubMedCrossRef
17.
go back to reference Musgrave DS, Idler RS (2005) Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates. J Hand Surg Am 30(4):743–749PubMedCrossRef Musgrave DS, Idler RS (2005) Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates. J Hand Surg Am 30(4):743–749PubMedCrossRef
19.
go back to reference Orbay JL, Fernandez DL (2002) Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am 27(2):205–215PubMedCrossRef Orbay JL, Fernandez DL (2002) Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am 27(2):205–215PubMedCrossRef
20.
go back to reference Pichler W, Clement H, Hausleitner L, Tanzer K, Tesch NP, Grechenig W (2008) Various circular arc radii of the distal volar radius and the implications on volar plate osteosynthesis. Orthopedics 31(12):1192CrossRef Pichler W, Clement H, Hausleitner L, Tanzer K, Tesch NP, Grechenig W (2008) Various circular arc radii of the distal volar radius and the implications on volar plate osteosynthesis. Orthopedics 31(12):1192CrossRef
21.
go back to reference Pichler W, Windisch G, Schaffler G, Rienmüller R, Grechenig W (2009) Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on the volar plate osteosynthesis. J Hand Surg 34-E(5):598–602 Pichler W, Windisch G, Schaffler G, Rienmüller R, Grechenig W (2009) Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on the volar plate osteosynthesis. J Hand Surg 34-E(5):598–602
22.
go back to reference Rikli DA, Regazzoni P (1996) Fractures of the distal end of the radius treated by internal fixation and early function. A preliminary report of 20 cases. J Bone Joint Surg Br 78(4):588–592PubMed Rikli DA, Regazzoni P (1996) Fractures of the distal end of the radius treated by internal fixation and early function. A preliminary report of 20 cases. J Bone Joint Surg Br 78(4):588–592PubMed
23.
go back to reference Rozental TD, Blazar PE (2006) Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 31(3):359–365PubMedCrossRef Rozental TD, Blazar PE (2006) Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 31(3):359–365PubMedCrossRef
24.
go back to reference Ruch DS, Papadonikolakis A (2006) Volar versus dorsal plating in the management of intra-articular distal radius fractures. J Hand Surg Am 31(1):9–16PubMedCrossRef Ruch DS, Papadonikolakis A (2006) Volar versus dorsal plating in the management of intra-articular distal radius fractures. J Hand Surg Am 31(1):9–16PubMedCrossRef
25.
go back to reference Windisch G, Clement H, Tanzer K, Feigl G, Grechenig W, Anderhuber F, Pichler W (2007) Promontory of radius: a new anatomical description on the distal radius. Surg Radiol Anat 29(8):629–633PubMedCrossRef Windisch G, Clement H, Tanzer K, Feigl G, Grechenig W, Anderhuber F, Pichler W (2007) Promontory of radius: a new anatomical description on the distal radius. Surg Radiol Anat 29(8):629–633PubMedCrossRef
26.
go back to reference Wong-Chung J, Quinlan W (1989) Rupture of extensor pollicis longus following fixation of a distal radius fracture. Injury 20(6):375–376PubMedCrossRef Wong-Chung J, Quinlan W (1989) Rupture of extensor pollicis longus following fixation of a distal radius fracture. Injury 20(6):375–376PubMedCrossRef
Metadata
Title
Anatomical and radiological study applied to distal radius surgery
Authors
N. Gasse
D. Lepage
R. Pem
C. Bernard
J. M. Lerais
P. Garbuio
L. Obert
Publication date
01-08-2011
Publisher
Springer-Verlag
Published in
Surgical and Radiologic Anatomy / Issue 6/2011
Print ISSN: 0930-1038
Electronic ISSN: 1279-8517
DOI
https://doi.org/10.1007/s00276-010-0754-x

Other articles of this Issue 6/2011

Surgical and Radiologic Anatomy 6/2011 Go to the issue