Skip to main content
Top
Published in: Surgical and Radiologic Anatomy 3/2007

01-04-2007 | Original Article

Morphometric parameters of the radial head: an anatomical study

Authors: T. C. Koslowsky, I. Germund, F. Beyer, K. Mader, C. F. Krieglstein, J. Koebke

Published in: Surgical and Radiologic Anatomy | Issue 3/2007

Login to get access

Abstract

Introduction

Exact anatomical description of the proximal radius is imperative for the development of radial head prostheses. The purpose of this study was to measure the anatomical parameters of the radial head.

Methods

Optosil imprints of 18 pairs of proximal radii fixed with formalin were taken. All possessed their native cartilage joint surface free of any arthritic defects. After being cut into 3 mm slices, the diameter of each slice was measured in steps of 30° of rotation with the margo interosseous acting as a reference point.

Results

Maximum radial head diameter was seen from the 0 to the 9 mm slice at a rotation of 30° to full supination perpendicular to the proximal radioulnar joint. The diameter increased from the radiocapitular joint surface to the 6 mm slice, and then it decreased (P < 0.001). At the level of 6 mm the maximum radial head diameter was 24.13 mm (range 21.2–27.3 mm). The minimum diameter was seen perpendicular to the maximum; it also increased from the radiocapitular joint surface to the 6 mm slice and then decreased. There was a significant difference between the minimum and maximum diameter of each slice at a P-level of P < 0.001. Left and right sides were not significantly different at a P-level of 0.01.

Conclusion

Our data show that the radial head is neither round nor conical. It has a complex shape with an increasing size from the radiocapitular joint surface to the middle of the proximal radioulnar joint surface. No statistically significant differences could be observed between right and left radii.
Literature
1.
go back to reference Alcaniz M, Montserrat C, Grau V, Chinesta F, Ramon A, Albalat S (1998) An advanced system for the simulation and planning of orthodontic treatment. Med Image Anal 2(1):61–77PubMedCrossRef Alcaniz M, Montserrat C, Grau V, Chinesta F, Ramon A, Albalat S (1998) An advanced system for the simulation and planning of orthodontic treatment. Med Image Anal 2(1):61–77PubMedCrossRef
2.
go back to reference Beredjiklian PK, Nalbantoglu U, Potter H, Hotchkiss RN (1998) Prosthetic radial head components and proximal radial morphology: a mismatch. J Shoulder Elbow Surg 8:471–475CrossRef Beredjiklian PK, Nalbantoglu U, Potter H, Hotchkiss RN (1998) Prosthetic radial head components and proximal radial morphology: a mismatch. J Shoulder Elbow Surg 8:471–475CrossRef
3.
go back to reference Captier G, Canovas F, Mercier N, Thomas E, Bonnel F (2002) Biometry of the radial head: biomechanical implications in pronation and supination. Surg Radiol Anat 24(5):295–301PubMedCrossRef Captier G, Canovas F, Mercier N, Thomas E, Bonnel F (2002) Biometry of the radial head: biomechanical implications in pronation and supination. Surg Radiol Anat 24(5):295–301PubMedCrossRef
4.
go back to reference Carn RM, Medige J, Curtain D, Koenig A (1986) Silicone rubber replacement of the severely fractured radial head. Clin Orthop 209:259–269PubMed Carn RM, Medige J, Curtain D, Koenig A (1986) Silicone rubber replacement of the severely fractured radial head. Clin Orthop 209:259–269PubMed
5.
go back to reference Carr CR, Howard JW (1951) Metallic cap replacement of radial head following fracture. West J Surg Obstet Gynecol 59:539–546PubMed Carr CR, Howard JW (1951) Metallic cap replacement of radial head following fracture. West J Surg Obstet Gynecol 59:539–546PubMed
6.
go back to reference Cherry JC (1953) Use of acrylic prosthesis in treatment of fracture of the head of the radius. J Bone Joint Surg 35-B:70–71 Cherry JC (1953) Use of acrylic prosthesis in treatment of fracture of the head of the radius. J Bone Joint Surg 35-B:70–71
7.
go back to reference Gupta GG, Moore-Jansen PH, Lucas GL (1992) Differences in radial head dimensions based on gender, race, age and side. Orthop Trans 16:342 Gupta GG, Moore-Jansen PH, Lucas GL (1992) Differences in radial head dimensions based on gender, race, age and side. Orthop Trans 16:342
8.
go back to reference Herbertsson P, Josefsson PO, Hasserius R, Besjakov J, Nyqvist F, Karlsson MK (2004) Fractures of the radial head treated with radial head excision. J Bone Joint Surg 86-A(9):1925–1930PubMed Herbertsson P, Josefsson PO, Hasserius R, Besjakov J, Nyqvist F, Karlsson MK (2004) Fractures of the radial head treated with radial head excision. J Bone Joint Surg 86-A(9):1925–1930PubMed
9.
go back to reference Ikeda M, Sugiyama K, Kang C, Takagaki T, Oka Y (2005) Comminuted fractures of the radial head. Comparison of resection and internal fixation. J Bone Joint Surg 87-A:76–84CrossRef Ikeda M, Sugiyama K, Kang C, Takagaki T, Oka Y (2005) Comminuted fractures of the radial head. Comparison of resection and internal fixation. J Bone Joint Surg 87-A:76–84CrossRef
10.
go back to reference Ikeda M, Yamashina Y, Kamimoto M, Oka Y (2003) Open reduction and internal fixation of comminuted fractures of the radial head using low-profile mini-plates. J Bone Joint Surg 84-B:1040–1044CrossRef Ikeda M, Yamashina Y, Kamimoto M, Oka Y (2003) Open reduction and internal fixation of comminuted fractures of the radial head using low-profile mini-plates. J Bone Joint Surg 84-B:1040–1044CrossRef
11.
go back to reference King GJ, Zarzour ZD, Patterson SD, Johnson JA (2001) An anthropometric study of the radial head: implications in the design of a prosthesis. J Arthroplasty 16(1):112–116PubMedCrossRef King GJ, Zarzour ZD, Patterson SD, Johnson JA (2001) An anthropometric study of the radial head: implications in the design of a prosthesis. J Arthroplasty 16(1):112–116PubMedCrossRef
12.
go back to reference König S, Goldammer A, Vitzthum HE (2005) Anatomical data on the craniocervical junction and its correlation with degenerative changes in 30 cadaveric specimens. J Neurosurg Spine 3:379–385PubMedCrossRef König S, Goldammer A, Vitzthum HE (2005) Anatomical data on the craniocervical junction and its correlation with degenerative changes in 30 cadaveric specimens. J Neurosurg Spine 3:379–385PubMedCrossRef
13.
go back to reference Mahaisavariya B, Saekee B, Sitthiseripratip K, Oris P, Tongdee T, Bohez EL, Vander Sloten J (2004) Morphology of the radial head: a reverse engineering based evaluation using three-dimensional anatomical data of radial bone. Proc Inst Mech Eng (H) 218(1):79–84 Mahaisavariya B, Saekee B, Sitthiseripratip K, Oris P, Tongdee T, Bohez EL, Vander Sloten J (2004) Morphology of the radial head: a reverse engineering based evaluation using three-dimensional anatomical data of radial bone. Proc Inst Mech Eng (H) 218(1):79–84
14.
go back to reference Murai Lau HK, Pereira BP, Pho RW (1997) A cadaveric study on volume and surface area of the fingertip. J Hand Surg 22(5):935–941CrossRef Murai Lau HK, Pereira BP, Pho RW (1997) A cadaveric study on volume and surface area of the fingertip. J Hand Surg 22(5):935–941CrossRef
15.
go back to reference Popovic N, Djekic Jire R, Lemaire R, Gellet P (2005) A comparative study between proximal radial morphology and the floating radial head prosthesis. J Shoulder Elbow Surg 14/4:433–440CrossRef Popovic N, Djekic Jire R, Lemaire R, Gellet P (2005) A comparative study between proximal radial morphology and the floating radial head prosthesis. J Shoulder Elbow Surg 14/4:433–440CrossRef
16.
go back to reference Ring D, Quintero J, Jupiter JB (2002) Open reduction and internal fixation of the fractures of the radial head. J Bone Joint Surg (Am) 84-A:1811–1815 Ring D, Quintero J, Jupiter JB (2002) Open reduction and internal fixation of the fractures of the radial head. J Bone Joint Surg (Am) 84-A:1811–1815
17.
go back to reference Roidis N, Stevanovic M, Martirosian A, Abbott DD, McPherson EJ, Itamura JM (2003) A radiographic study of proximal radius anatomy with implications in radial head replacement. J Shoulder Elbow Surg 12(4):380–384PubMedCrossRef Roidis N, Stevanovic M, Martirosian A, Abbott DD, McPherson EJ, Itamura JM (2003) A radiographic study of proximal radius anatomy with implications in radial head replacement. J Shoulder Elbow Surg 12(4):380–384PubMedCrossRef
18.
go back to reference Sanchez-Sotelo J, Romanillos O, Garay EG (2000) Results of acute excision of the radial head in elbow radial head fracture-dislocation. J Orthop Trauma 14(5):354–358PubMedCrossRef Sanchez-Sotelo J, Romanillos O, Garay EG (2000) Results of acute excision of the radial head in elbow radial head fracture-dislocation. J Orthop Trauma 14(5):354–358PubMedCrossRef
19.
go back to reference Sarnat BG (1980) Orbital volume in young and adult rabbits. Anat Embryol (Berl) 159(2):211–221CrossRef Sarnat BG (1980) Orbital volume in young and adult rabbits. Anat Embryol (Berl) 159(2):211–221CrossRef
20.
go back to reference Skalski K, Swieszkowski W, Pomianowski St, Kedzior K, Kowalik St (2004) Radial head prosthesis with a mobile head. J Shoulder Elbow Surg 13/1:78–85CrossRef Skalski K, Swieszkowski W, Pomianowski St, Kedzior K, Kowalik St (2004) Radial head prosthesis with a mobile head. J Shoulder Elbow Surg 13/1:78–85CrossRef
21.
go back to reference Spector MR, Donovan TE, Nicholls (1990) An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 63:444–447PubMedCrossRef Spector MR, Donovan TE, Nicholls (1990) An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 63:444–447PubMedCrossRef
22.
go back to reference Speed K (1941) Ferrule caps for the head of the radius Surg. Gynecol Obstet 73: 845–850 Speed K (1941) Ferrule caps for the head of the radius Surg. Gynecol Obstet 73: 845–850
23.
go back to reference Swieszkowski W, Skalski K, Pomianowski S, Kedzior K (2001) The anatomic features of the radial head and their implication for prosthesis design. Clin Biomech (Bristol, Avon) 16(10):880–887CrossRef Swieszkowski W, Skalski K, Pomianowski S, Kedzior K (2001) The anatomic features of the radial head and their implication for prosthesis design. Clin Biomech (Bristol, Avon) 16(10):880–887CrossRef
24.
go back to reference Toksvig-Larsen S, Kroon PO, Ryd L (1994) Improved bone cutting using a semi-rotating saw. A cadaver study of the cut surface on tibial condyles. Acta Orthop Scand 65(4):412–414PubMedCrossRef Toksvig-Larsen S, Kroon PO, Ryd L (1994) Improved bone cutting using a semi-rotating saw. A cadaver study of the cut surface on tibial condyles. Acta Orthop Scand 65(4):412–414PubMedCrossRef
25.
go back to reference Van Glabbeck F, Van Riet R, Verstreken J (2001) Current concepts in the treatment of radial head fractures in adults: a clinical and biomechanical approach. Acta Orthopedica Belgica 67-5:430–441 Van Glabbeck F, Van Riet R, Verstreken J (2001) Current concepts in the treatment of radial head fractures in adults: a clinical and biomechanical approach. Acta Orthopedica Belgica 67-5:430–441
26.
go back to reference van Riet RP, Van Glabbeek F, Baumfeld JA, Neale PG, Morrey BF, O’Driscoll SW, An KN (2004) The effect of the orientation of the non-circular radial head on elbow kinematics. Clin Biomech 19:595–599CrossRef van Riet RP, Van Glabbeek F, Baumfeld JA, Neale PG, Morrey BF, O’Driscoll SW, An KN (2004) The effect of the orientation of the non-circular radial head on elbow kinematics. Clin Biomech 19:595–599CrossRef
27.
go back to reference van Riet RP, Van Glabbeek F, Neale PG, Bortier H, An KN, O’Driscoll SW (2003) The non-circular shape of the radial head. J Hand Surg (Am) 28(6):972–978CrossRef van Riet RP, Van Glabbeek F, Neale PG, Bortier H, An KN, O’Driscoll SW (2003) The non-circular shape of the radial head. J Hand Surg (Am) 28(6):972–978CrossRef
28.
go back to reference Weiss A-PC, Hastings H II (1992) The anatomy of the proximal radioulnar joint. J Shoulder Elbow Surg 1:193–199CrossRef Weiss A-PC, Hastings H II (1992) The anatomy of the proximal radioulnar joint. J Shoulder Elbow Surg 1:193–199CrossRef
Metadata
Title
Morphometric parameters of the radial head: an anatomical study
Authors
T. C. Koslowsky
I. Germund
F. Beyer
K. Mader
C. F. Krieglstein
J. Koebke
Publication date
01-04-2007
Publisher
Springer-Verlag
Published in
Surgical and Radiologic Anatomy / Issue 3/2007
Print ISSN: 0930-1038
Electronic ISSN: 1279-8517
DOI
https://doi.org/10.1007/s00276-007-0197-1

Other articles of this Issue 3/2007

Surgical and Radiologic Anatomy 3/2007 Go to the issue