Abstract

Purpose

The intent of this report is to describe the technical details and rationale of endovascular septectomy using a wire saw maneuver in cases of chronic aortic dissection and associated infra-renal aortic aneurysm to allow standard endovascular abdominal aortic graft placement; preliminary clinical experience is also retrospectively reviewed.

Materials and Methods

Between June 2013 and June 2016, four consecutive patients (mean age 55.3 years; range 52–58 years) with chronic type B aortic dissection and isolated infra-renal abdominal aortic aneurysm (AAA) underwent endovascular aneurysm repair (EVAR) following guidewire septectomy to create a suitable proximal aortic landing zone. Technical success was evaluated by angiography performed at the end of the procedure. Procedural safety was determined by assessing any major adverse events through 30 days of follow-up. Endoleaks and longer-term efficacy were evaluated.

Results

Four patients with chronic aortic dissections had associated AAA with a mean maximum diameter of 60 ± 13 mm (range 50–77 mm). All underwent guidewire saw septectomy to facilitate EVAR. Following successful septectomy, standard abdominal bifurcated endografts were implanted uneventfully. No major adverse events and no endoleaks were noted on CT angiographic examinations through 30 days following the procedure. Also, no rupture, re-intervention or endoleak has been noted during follow-up at a mean of 21.8 ± 15 months (range 4–39 months).

Conclusions

Guidewire saw septectomy is a technique that has the potential to create an anatomically suitable proximal neck for successful EVAR management of AAA in select patients with associated chronic aortic dissection.
Literature
1.
go back to reference Williams DM, Brothers TE, Messina LM. Relief of mesenteric ischemia in type III aortic dissection with percutaneous fenestration of the aortic septum. Radiology. 1990;174:450–2.CrossRefPubMed Williams DM, Brothers TE, Messina LM. Relief of mesenteric ischemia in type III aortic dissection with percutaneous fenestration of the aortic septum. Radiology. 1990;174:450–2.CrossRefPubMed
2.
go back to reference Hartnell GG, Gates J. Aortic fenestration: a why, when, and how-to guide. Radiographics. 2005;25:175–89.CrossRefPubMed Hartnell GG, Gates J. Aortic fenestration: a why, when, and how-to guide. Radiographics. 2005;25:175–89.CrossRefPubMed
3.
go back to reference Wuest W, Goltz J, Ritter C, Yildirim C, Hahn D, Kickuth R. Fenestration of aortic dissection using a fluoroscopy-based needle re-entry catheter system. Cardiovasc Interv Radiol. 2011;34:S44–7.CrossRef Wuest W, Goltz J, Ritter C, Yildirim C, Hahn D, Kickuth R. Fenestration of aortic dissection using a fluoroscopy-based needle re-entry catheter system. Cardiovasc Interv Radiol. 2011;34:S44–7.CrossRef
4.
go back to reference Tashiro J, Baqai A, Goldstein LJ, Salsamendi JT, Taubman M, Rey J. “Cheese wire” fenestration of a chronic aortic dissection flap for endovascular repair of a contained aneurysm rupture. J Vasc Surg. 2014;60:497–9.CrossRefPubMed Tashiro J, Baqai A, Goldstein LJ, Salsamendi JT, Taubman M, Rey J. “Cheese wire” fenestration of a chronic aortic dissection flap for endovascular repair of a contained aneurysm rupture. J Vasc Surg. 2014;60:497–9.CrossRefPubMed
5.
go back to reference Ullery BW, Chandra V, Dake M, Lee JT. Cheese wire fenestration of a chronic juxtarenal dissection flap to facilitate proximal neck fixation during EVAR. Ann Vasc Surg. 2015;29:124.e1–5.CrossRef Ullery BW, Chandra V, Dake M, Lee JT. Cheese wire fenestration of a chronic juxtarenal dissection flap to facilitate proximal neck fixation during EVAR. Ann Vasc Surg. 2015;29:124.e1–5.CrossRef
6.
go back to reference Kos S, Gürke L, Jacob AL. A novel fenestration technique for abdominal aortic dissection membranes using a combination of a needle re-entry catheter and the “cheese-wire” technique. Cardiovasc Interv Radiol. 2011;34:1296–302.CrossRef Kos S, Gürke L, Jacob AL. A novel fenestration technique for abdominal aortic dissection membranes using a combination of a needle re-entry catheter and the “cheese-wire” technique. Cardiovasc Interv Radiol. 2011;34:1296–302.CrossRef
7.
go back to reference Watkinson AF. A novel “cheese wire” technique for stent positioning following difficult iliac artery subintimal dissection and aortic re-entry. Cardiovasc Interv Radiol. 2009;32:781–4.CrossRef Watkinson AF. A novel “cheese wire” technique for stent positioning following difficult iliac artery subintimal dissection and aortic re-entry. Cardiovasc Interv Radiol. 2009;32:781–4.CrossRef
8.
go back to reference Brunori A, Bruni P, Greco R, Giuffré R, Chiappetta F. Celebrating the centennial (1894–1994): Leonardo Gigli and his wire saw. J Neurosurg. 1995;82:1086–90.CrossRefPubMed Brunori A, Bruni P, Greco R, Giuffré R, Chiappetta F. Celebrating the centennial (1894–1994): Leonardo Gigli and his wire saw. J Neurosurg. 1995;82:1086–90.CrossRefPubMed
Metadata
Title
Percutaneous Septectomy in Chronic Dissection with Abdominal Aortic Aneurysm Creates Uniluminal Neck for EVAR
Authors
Mark Colin Gissler
Yukihisa Ogawa
Jason T. Lee
Venita Chandra
Michael D. Dake
Publication date
01-10-2017
Publisher
Springer US
Published in
CardioVascular and Interventional Radiology / Issue 10/2017
Print ISSN: 0174-1551
Electronic ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-017-1668-3

Other articles of this Issue 10/2017

CardioVascular and Interventional Radiology 10/2017 Go to the issue