Skip to main content
Top
Published in: CardioVascular and Interventional Radiology 6/2009

01-11-2009 | Case Report

Second-Generation Amplatzer Vascular Plug (AVP) for the Treatment of Subsequent Subclavian Backflow Type II Endoleak After TEVAR

Authors: Carsten Meyer, Chris Probst, Holger Strunk, Wolfgang Schiller, Kai Wilhelm

Published in: CardioVascular and Interventional Radiology | Issue 6/2009

Login to get access

Abstract

Since its approval as an occlusive device in the peripheral vasculature in 2004, the first-generation Amplatzer Vascular Plug (AVP; AGA Medical, Golden Valley, MN, USA) has already become a therapeutic alternative to coil embolization in dedicated cases. Here, we present for the first time, a case of type II endoleak from the left subclavian artery after thoracic stent-graft placement successfully treated with a second-generation AVP.
Literature
1.
go back to reference Black SA, Wolfe JH, Clark M, Hamady M, Cheshire NJ, Jenkins MP (2006) Complex thoracoabdominal aortic aneurysms: endovascular exclusion with visceral revascularization. J Vasc Surg 43:1081–1089 discussion 1089CrossRefPubMed Black SA, Wolfe JH, Clark M, Hamady M, Cheshire NJ, Jenkins MP (2006) Complex thoracoabdominal aortic aneurysms: endovascular exclusion with visceral revascularization. J Vasc Surg 43:1081–1089 discussion 1089CrossRefPubMed
2.
go back to reference Probst C, Esmailzadeh B, Schiller W, Wilhelm K (2008) Emergent antegrade endovascular stent placement in a patient with perforated Stanford B dissection via right axillary artery. Eur J Cardiothorac Surg 33:1148–1149CrossRefPubMed Probst C, Esmailzadeh B, Schiller W, Wilhelm K (2008) Emergent antegrade endovascular stent placement in a patient with perforated Stanford B dissection via right axillary artery. Eur J Cardiothorac Surg 33:1148–1149CrossRefPubMed
3.
go back to reference Qu L, Raithel D (2008) Two-year single-center experience with thoracic endovascular aortic repair using the EndoFit thoracic stent-graft. J Endovasc Ther 15:530–538CrossRefPubMed Qu L, Raithel D (2008) Two-year single-center experience with thoracic endovascular aortic repair using the EndoFit thoracic stent-graft. J Endovasc Ther 15:530–538CrossRefPubMed
4.
go back to reference Gorich J, Asquan Y, Seifarth H et al (2002) Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs. J Endovasc Ther 9(Suppl 2):II39–II43PubMed Gorich J, Asquan Y, Seifarth H et al (2002) Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs. J Endovasc Ther 9(Suppl 2):II39–II43PubMed
5.
go back to reference Rehders TC, Petzsch M, Ince H et al (2004) Intentional occlusion of the left subclavian artery during stent-graft implantation in the thoracic aorta: risk and relevance. J Endovasc Ther 11:659–666CrossRefPubMed Rehders TC, Petzsch M, Ince H et al (2004) Intentional occlusion of the left subclavian artery during stent-graft implantation in the thoracic aorta: risk and relevance. J Endovasc Ther 11:659–666CrossRefPubMed
6.
go back to reference Riesenman PJ, Farber MA, Mendes RR, Marston WA, Fulton JJ, Keagy BA (2007) Coverage of the left subclavian artery during thoracic endovascular aortic repair. J Vasc Surg 45:90–94 discussion 94–95CrossRefPubMed Riesenman PJ, Farber MA, Mendes RR, Marston WA, Fulton JJ, Keagy BA (2007) Coverage of the left subclavian artery during thoracic endovascular aortic repair. J Vasc Surg 45:90–94 discussion 94–95CrossRefPubMed
7.
go back to reference Caronno R, Piffaretti G, Tozzi M, Lomazzi C, Rivolta N, Castelli P (2006) Intentional coverage of the left subclavian artery during endovascular stent graft repair for thoracic aortic disease. Surg Endosc 20:915–918CrossRefPubMed Caronno R, Piffaretti G, Tozzi M, Lomazzi C, Rivolta N, Castelli P (2006) Intentional coverage of the left subclavian artery during endovascular stent graft repair for thoracic aortic disease. Surg Endosc 20:915–918CrossRefPubMed
8.
go back to reference Dunning J, Martin JE, Shennib H, Cheng DC (2008) Is it safe to cover the left subclavian artery when placing an endovascular stent in the descending thoracic aorta? Interact Cardiovasc Thorac Surg 7:690–697CrossRefPubMed Dunning J, Martin JE, Shennib H, Cheng DC (2008) Is it safe to cover the left subclavian artery when placing an endovascular stent in the descending thoracic aorta? Interact Cardiovasc Thorac Surg 7:690–697CrossRefPubMed
9.
go back to reference Konya A, Maxin M, Wright KC (2001) New embolization coil containing a nitinol wire core: preliminary in vitro and in vivo experiences. J Vasc Interv Radiol. 12:869–877CrossRefPubMed Konya A, Maxin M, Wright KC (2001) New embolization coil containing a nitinol wire core: preliminary in vitro and in vivo experiences. J Vasc Interv Radiol. 12:869–877CrossRefPubMed
10.
go back to reference Ratnam LA, Walkden RM, Munneke GJ, Morgan RA, Belli AM (2008) The Amplatzer vascular plug for large vessel occlusion in the endovascular management of aneurysms. Eur Radiol 18:2006–2012CrossRefPubMed Ratnam LA, Walkden RM, Munneke GJ, Morgan RA, Belli AM (2008) The Amplatzer vascular plug for large vessel occlusion in the endovascular management of aneurysms. Eur Radiol 18:2006–2012CrossRefPubMed
Metadata
Title
Second-Generation Amplatzer Vascular Plug (AVP) for the Treatment of Subsequent Subclavian Backflow Type II Endoleak After TEVAR
Authors
Carsten Meyer
Chris Probst
Holger Strunk
Wolfgang Schiller
Kai Wilhelm
Publication date
01-11-2009
Publisher
Springer-Verlag
Published in
CardioVascular and Interventional Radiology / Issue 6/2009
Print ISSN: 0174-1551
Electronic ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-009-9517-7

Other articles of this Issue 6/2009

CardioVascular and Interventional Radiology 6/2009 Go to the issue