Unusual Presentation of Infected Vertebroplasty with Delayed Cement Dislodgment in an Immunocompromised Patient: Case Report and Review of Literature

Authors: Wei-Che Lin, Chen-Hsiang Lee, Shih-Hao Chen, Chun-Chung Lui

Published in: CardioVascular and Interventional Radiology | Special Issue 2/2008

Login to get access

Abstract

Percutaneous vertebroplasty has been established as a safe and effective treatment for compression fractures of osteoporotic vertebrae. Complications of vertebroplasty, such as infection or anterior cement extrusion, are rare. Herein, we report an unusual presentation in an immunocompromised patient with an insidious infection of the disk. This infection resulted in dislodgment of the cement inferiorly and a compression fracture of the adjacent vertebra 6 months after vertebroplasty. We discuss the significance of this case and compare it with 7 others found in the literature.
Literature
1.
go back to reference Kallmes DF, Schweickert PA, Marx WF, et al. (2002) Vertebroplasty in the mid- and upper thoracic spine. AJNR Am J Neuroradiol 23:1117–1120PubMed Kallmes DF, Schweickert PA, Marx WF, et al. (2002) Vertebroplasty in the mid- and upper thoracic spine. AJNR Am J Neuroradiol 23:1117–1120PubMed
2.
go back to reference Jensen ME, Evans AJ, Mathis JM, et al. (1997) Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects. AJNR Am J Neuroradiol 18:1897–1904PubMed Jensen ME, Evans AJ, Mathis JM, et al. (1997) Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects. AJNR Am J Neuroradiol 18:1897–1904PubMed
3.
go back to reference Yu SW, Chen WJ, Lin WC, et al. (2004) Serious pyogenic spondylitis following vertebroplasty: A case report. Spine 29:E209–211PubMedCrossRef Yu SW, Chen WJ, Lin WC, et al. (2004) Serious pyogenic spondylitis following vertebroplasty: A case report. Spine 29:E209–211PubMedCrossRef
4.
go back to reference Walker DH, Mummaneni P, Rodts GE Jr (2004) Infected vertebroplasty. Report of two cases and review of the literature. Neurosurg Focus 17:E6PubMedCrossRef Walker DH, Mummaneni P, Rodts GE Jr (2004) Infected vertebroplasty. Report of two cases and review of the literature. Neurosurg Focus 17:E6PubMedCrossRef
5.
go back to reference Vats HS, McKiernan FE (2006) Infected vertebroplasty: Case report and review of literature. Spine 31:E859–862PubMedCrossRef Vats HS, McKiernan FE (2006) Infected vertebroplasty: Case report and review of literature. Spine 31:E859–862PubMedCrossRef
6.
go back to reference Schmid KE, Boszczyk BM, Bierschneider M, et al. (2005) Spondylitis following vertebroplasty: A case report. Eur Spine J 14:895–899PubMedCrossRef Schmid KE, Boszczyk BM, Bierschneider M, et al. (2005) Spondylitis following vertebroplasty: A case report. Eur Spine J 14:895–899PubMedCrossRef
7.
go back to reference Alfonso Olmos M, Silva Gonzalez A, Duart Clemente J, et al. (2006) Infected vertebroplasty due to uncommon bacteria solved surgically: A rare and threatening life complication of a common procedure. Report of a case and a review of the literature. Spine 31:E770–773PubMedCrossRef Alfonso Olmos M, Silva Gonzalez A, Duart Clemente J, et al. (2006) Infected vertebroplasty due to uncommon bacteria solved surgically: A rare and threatening life complication of a common procedure. Report of a case and a review of the literature. Spine 31:E770–773PubMedCrossRef
8.
go back to reference Lee BJ, Lee SR, Yoo TY (2002) Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: A case report. Spine 27:E419–422PubMedCrossRef Lee BJ, Lee SR, Yoo TY (2002) Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: A case report. Spine 27:E419–422PubMedCrossRef
9.
go back to reference Francois K, Taeymans Y, Poffyn B, et al. (2003) Successful management of a large pulmonary cement embolus after percutaneous vertebroplasty: A case report. Spine 28:E424–425PubMedCrossRef Francois K, Taeymans Y, Poffyn B, et al. (2003) Successful management of a large pulmonary cement embolus after percutaneous vertebroplasty: A case report. Spine 28:E424–425PubMedCrossRef
10.
go back to reference Wagner AL, Baskurt E (2006) Refracture with cement extrusion following percutaneous vertebroplasty of a large interbody cleft. AJNR Am J Neuroradiol 27:230–231PubMed Wagner AL, Baskurt E (2006) Refracture with cement extrusion following percutaneous vertebroplasty of a large interbody cleft. AJNR Am J Neuroradiol 27:230–231PubMed
11.
go back to reference Tsai TT, Chen WJ, Lai PL, et al. (2003) Polymethylmethacrylate cement dislodgment following percutaneous vertebroplasty: A case report. Spine 28:E457–460PubMedCrossRef Tsai TT, Chen WJ, Lai PL, et al. (2003) Polymethylmethacrylate cement dislodgment following percutaneous vertebroplasty: A case report. Spine 28:E457–460PubMedCrossRef
12.
go back to reference Larsen HS, Mahon CR (2000) Staphylococci. In: Mahon CR, Manuselis G (eds) Textbook of diagnostic microbiology. WB Saunders, Philadelphia, pp 330–343 Larsen HS, Mahon CR (2000) Staphylococci. In: Mahon CR, Manuselis G (eds) Textbook of diagnostic microbiology. WB Saunders, Philadelphia, pp 330–343
13.
go back to reference Lewis G (1997) Properties of acrylic bone cement: State of the art review. J Biomed Mater Res 38:155–182PubMedCrossRef Lewis G (1997) Properties of acrylic bone cement: State of the art review. J Biomed Mater Res 38:155–182PubMedCrossRef
14.
go back to reference Lim TH, Brebach GT, Renner SM, et al. (2002) Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty. Spine 27:1297–1302PubMedCrossRef Lim TH, Brebach GT, Renner SM, et al. (2002) Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty. Spine 27:1297–1302PubMedCrossRef
15.
go back to reference Joly-Guillou ML (2005) Clinical impact and pathogenicity of Acinetobacter. Clin Microbiol Infect 11:868–873PubMedCrossRef Joly-Guillou ML (2005) Clinical impact and pathogenicity of Acinetobacter. Clin Microbiol Infect 11:868–873PubMedCrossRef
16.
go back to reference Lidwell OM (1986) Clean air at operation and subsequent sepsis in the joint. Clin Orthop:91–102 Lidwell OM (1986) Clean air at operation and subsequent sepsis in the joint. Clin Orthop:91–102
17.
go back to reference Buchholz HW, Elson RA, Heinert K (1984) Antibiotic-loaded acrylic cement: Current concepts. Clin Orthop:96–108 Buchholz HW, Elson RA, Heinert K (1984) Antibiotic-loaded acrylic cement: Current concepts. Clin Orthop:96–108
Metadata
Title
Unusual Presentation of Infected Vertebroplasty with Delayed Cement Dislodgment in an Immunocompromised Patient: Case Report and Review of Literature
Authors
Wei-Che Lin
Chen-Hsiang Lee
Shih-Hao Chen
Chun-Chung Lui
Publication date
01-07-2008
Publisher
Springer-Verlag
Published in
CardioVascular and Interventional Radiology / Issue Special Issue 2/2008
Print ISSN: 0174-1551
Electronic ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-007-9234-z

Other articles of this Special Issue 2/2008

CardioVascular and Interventional Radiology 2/2008 Go to the issue