01-11-2003 | Case Report
Use of the Trellis™ Peripheral Infusion System for Enhancement of rt-PA Thrombolysis in Acute Lower Limb Ischemia
Published in: CardioVascular and Interventional Radiology | Issue 6/2003
Login to get accessAbstract
The Trellis™ Peripheral Infusion System is an over-the-wire 0.035″ guidewire compatible device, designed to isolate a region of the peripheral vasculature to allow for lytic drug infusion and dispersion. We used it successfully through a percutaneous approach in two cases of acute thrombosis of a native lower limb artery. The total amount of rt-PA used was 12 and 9 mg, respectively and was delivered through bolus injections obviating the need for a supplementary continuous infusion of the agent. The time for dissolution of thrombus was 45 and 35 minutes, respectively. No complications were observed.