Skip to main content
Top
Published in: CardioVascular and Interventional Radiology 2/2003

01-04-2003 | Clinical Investigations

Carbon Dioxide in the Aortic Arch: Coronary Effects and Implications in a Swine Study

Authors: William C. Culp, Thomas R. Porter, William C. Culp Jr., Brian N. Vonk

Published in: CardioVascular and Interventional Radiology | Issue 2/2003

Login to get access

Abstract

Purpose: CO2 angiography is considered dangerous in the aortic arch where bubbles may cause critical cerebral and cardiac ischemia. We investigated CO2 distribution, physiologic effects in the heart, methods of detection and treatments. Methods: Eight pigs had CO2 and iodinated contrast arch angiograms in supine and both lateral decubitus positions. An electrocardiogram, physiologic data and cardiac ultrasound were obtained. Therapies included precordial thumps and rolls to lateral decubitus positions. Results: Supine high descending aorta CO2 injections floated retrograde up the arch during diastole and preferentially filled the right coronary artery (RCA): mean score 3.5 (of 4), innominate artery 2.4, left coronary artery 1.2; n = 17; p = 0.0001. Aortic root injections preferentially filled the RCA when the animal was supine, left coronary in the right decubitus position, and showed a diffuse pattern in the left decubitus position. Right decubitus rolls filled both coronaries causing several lethal arrhythmias. Precordial thumps successfully cleared CO2. Ultrasound is a sensitive detector of myocardial CO2. Conclusion: Arch distribution of CO2 primarily involves the RCA. Diagnostic ultrasound detects cardiac CO2 well. Precordial thumps are an effective treatment.
Literature
1.
go back to reference Kerns, SR, Hawkins, IF Jr. 1995Carbon dioxide digital subtraction angiography: Expanding applications and technical evolution.AJR Am J Roentgenol164735741PubMed Kerns, SR, Hawkins, IF Jr. 1995Carbon dioxide digital subtraction angiography: Expanding applications and technical evolution.AJR Am J Roentgenol164735741PubMed
2.
go back to reference Hawkins, I, Caridi, J, Kerns, S 1995Plastic bag delivery system for hand injection of carbon dioxide.AJR Am J Roentgenol16514871489 Hawkins, I, Caridi, J, Kerns, S 1995Plastic bag delivery system for hand injection of carbon dioxide.AJR Am J Roentgenol16514871489
3.
go back to reference Hawkins, IF, Caridi, JG, Klioze, SD, Mladinich, CR 2001Modified plastic bag system with O-ring fitting connection for carbon dioxide angiography.AJR Am J Roentgenol176229232 Hawkins, IF, Caridi, JG, Klioze, SD, Mladinich, CR 2001Modified plastic bag system with O-ring fitting connection for carbon dioxide angiography.AJR Am J Roentgenol176229232
4.
go back to reference Hahn, ST, Pfammatter, T, Cho, KJ 1995Carbon dioxide gas as a venous contrast agent to guide upper-arm insertion of central venous catheters.Cardiovasc Intervent Radiol18146149PubMed Hahn, ST, Pfammatter, T, Cho, KJ 1995Carbon dioxide gas as a venous contrast agent to guide upper-arm insertion of central venous catheters.Cardiovasc Intervent Radiol18146149PubMed
5.
go back to reference Boyd-Kranis, R, Sullivan, KL, Eschelman, DJ, Bonn, J, Gardiner, GA 1999Accuracy and safety of carbon dioxide inferior vena cavography.J Vasc Interv Radiol1011831189 Boyd-Kranis, R, Sullivan, KL, Eschelman, DJ, Bonn, J, Gardiner, GA 1999Accuracy and safety of carbon dioxide inferior vena cavography.J Vasc Interv Radiol1011831189
6.
go back to reference Hawkins, IF Jr, Caridi, JG 1999Fine needle transjugular intrahepatic portosystemic shunt procedure with CO2.AJR Am J Roentgenol173625629PubMed Hawkins, IF Jr, Caridi, JG 1999Fine needle transjugular intrahepatic portosystemic shunt procedure with CO2.AJR Am J Roentgenol173625629PubMed
7.
go back to reference Rolland, Y, Duvauferrier, R, Lucas, A, Gourlay, C, Morcet, N, Rambeau, M, Chaperon, J 1998Lower limb angiography: A prospective study comparing carbon dioxide with iodinated contrast material in 30 patients.AJR Am J Roentgenol171333337PubMed Rolland, Y, Duvauferrier, R, Lucas, A, Gourlay, C, Morcet, N, Rambeau, M, Chaperon, J 1998Lower limb angiography: A prospective study comparing carbon dioxide with iodinated contrast material in 30 patients.AJR Am J Roentgenol171333337PubMed
8.
go back to reference Caridi, J, Hawkins, I 1997CO2 digital subtraction angiography: Potential complications and their prevention.J Vasc Interv Radiol8383391PubMed Caridi, J, Hawkins, I 1997CO2 digital subtraction angiography: Potential complications and their prevention.J Vasc Interv Radiol8383391PubMed
9.
go back to reference Rundback, J, Shah, P, Wong, J, Babu, SC, Rozenblit, G, Poplausky, MR 1997Livedo reticularis, rhabdomyolysis, massive intestinal infarction, and death after carbon dioxide arteriography.J Vasc Surg26337340PubMed Rundback, J, Shah, P, Wong, J, Babu, SC, Rozenblit, G, Poplausky, MR 1997Livedo reticularis, rhabdomyolysis, massive intestinal infarction, and death after carbon dioxide arteriography.J Vasc Surg26337340PubMed
10.
go back to reference Culp, WC, McCowan, T, Goertzen, T, Habbe, T 1998CO2 angiography: Complications and pseudocomplications (letter).J Vasc Interv Radiol10100101 Culp, WC, McCowan, T, Goertzen, T, Habbe, T 1998CO2 angiography: Complications and pseudocomplications (letter).J Vasc Interv Radiol10100101
11.
go back to reference Culp, WC, Goertzen, T, McCowan, T, Habbe, T, Hummel, M 1999Patient intolerance of CO2 angiography. (letter).AJR Am J Roentgenol173240241 Culp, WC, Goertzen, T, McCowan, T, Habbe, T, Hummel, M 1999Patient intolerance of CO2 angiography. (letter).AJR Am J Roentgenol173240241
12.
go back to reference Spinosa, DJ, Matsumoto, AH, Angle, JF, Hagspiel, KD, Hooper, TN 1998Transient mesenteric ischemia: A complication of CO2 angiography.J Vasc Interv Radiol9561564PubMed Spinosa, DJ, Matsumoto, AH, Angle, JF, Hagspiel, KD, Hooper, TN 1998Transient mesenteric ischemia: A complication of CO2 angiography.J Vasc Interv Radiol9561564PubMed
13.
go back to reference Wilson, AJ, Boxer, MM 1998Safety of carbon dioxide as a contrast medium in cerebral angiography.Acad Radiol5S51S53PubMed Wilson, AJ, Boxer, MM 1998Safety of carbon dioxide as a contrast medium in cerebral angiography.Acad Radiol5S51S53PubMed
14.
go back to reference Dimakakos, PB, Stefanopoulos, T, Doufas, AG, Papasava, M, Gouliamos, A, Mourikis, D, Deligiorgi, H 1998The cerebral effects of carbon dioxide during digital subtraction angiography in the aortic arch and its branches in rabbits.AJNR Am J Neuroradiol19261266PubMed Dimakakos, PB, Stefanopoulos, T, Doufas, AG, Papasava, M, Gouliamos, A, Mourikis, D, Deligiorgi, H 1998The cerebral effects of carbon dioxide during digital subtraction angiography in the aortic arch and its branches in rabbits.AJNR Am J Neuroradiol19261266PubMed
15.
go back to reference Linstedt, U, Link, J, Grabener, M, Kloess, W 1997Effects of selective angiography of the carotid artery with CO2 on electroencephalogram somatosensory evoked potentials and histopathologic findings: A pilot study in pigs.Invest Radiol32507510CrossRef Linstedt, U, Link, J, Grabener, M, Kloess, W 1997Effects of selective angiography of the carotid artery with CO2 on electroencephalogram somatosensory evoked potentials and histopathologic findings: A pilot study in pigs.Invest Radiol32507510CrossRef
16.
go back to reference Coffey, R, Quisling, RG, Mickle, JP, Hawkins, IF, Ballinger, WB 1984The cerebral effects of intraarterial CO2 in quantities required for diagnostic imaging.Radiology151405410PubMed Coffey, R, Quisling, RG, Mickle, JP, Hawkins, IF, Ballinger, WB 1984The cerebral effects of intraarterial CO2 in quantities required for diagnostic imaging.Radiology151405410PubMed
17.
go back to reference Ehrman, KO, Taber, TE, Gaylord, GM, Brown, PB, Hague, JP 1994Comparison of diagnostic accuracy with carbon dioxide versus iodinated contrast material in the imaging of hemodialysis access fistulas.J Vasc Interv Radiol5771775PubMed Ehrman, KO, Taber, TE, Gaylord, GM, Brown, PB, Hague, JP 1994Comparison of diagnostic accuracy with carbon dioxide versus iodinated contrast material in the imaging of hemodialysis access fistulas.J Vasc Interv Radiol5771775PubMed
18.
go back to reference Lambert, CR, de Marchena, EJ, Bikkina, M, Arcement, BK 1996Effects of intracoronary carbon dioxide on left ventricular function in swine.Clin Cardiol19461465PubMed Lambert, CR, de Marchena, EJ, Bikkina, M, Arcement, BK 1996Effects of intracoronary carbon dioxide on left ventricular function in swine.Clin Cardiol19461465PubMed
19.
go back to reference Melany, ML, Grant, EG 1997Clinical experience with sonographic contrast agents.Semin Ultrasound CT MRI18312 Melany, ML, Grant, EG 1997Clinical experience with sonographic contrast agents.Semin Ultrasound CT MRI18312
20.
go back to reference Anon., . 1998The guide for the care and use of laboratory animalsNational Academy PressWashington, DC Anon., . 1998The guide for the care and use of laboratory animalsNational Academy PressWashington, DC
21.
22.
go back to reference Caldwell, G, Millar, G, Quinn, E, Vincent, R, Chamberlain, DA 1985Simple mechanical methods for cardioversion: Defense of the precordial thump and cough version.Br Med J Clin Res291627630 Caldwell, G, Millar, G, Quinn, E, Vincent, R, Chamberlain, DA 1985Simple mechanical methods for cardioversion: Defense of the precordial thump and cough version.Br Med J Clin Res291627630
23.
go back to reference Miller, J, Tresch, D, Horwitz, L, Thompson, BM, Aprahamian, C, Darin, JC 1984The precordial thump.Ann Emerg Med13791794PubMed Miller, J, Tresch, D, Horwitz, L, Thompson, BM, Aprahamian, C, Darin, JC 1984The precordial thump.Ann Emerg Med13791794PubMed
24.
go back to reference Yakaitis, RW, Redding, JS 1973Precordial thumping during cardiac resuscitation.Crit Care Med12226PubMed Yakaitis, RW, Redding, JS 1973Precordial thumping during cardiac resuscitation.Crit Care Med12226PubMed
25.
go back to reference Gertsch, M, Hottinger, S, Hess, T 1992Serial chest thumps for the treatment of ventricular tachycardia in patients with coronary artery disease.Clin Cardiol15181188PubMed Gertsch, M, Hottinger, S, Hess, T 1992Serial chest thumps for the treatment of ventricular tachycardia in patients with coronary artery disease.Clin Cardiol15181188PubMed
Metadata
Title
Carbon Dioxide in the Aortic Arch: Coronary Effects and Implications in a Swine Study
Authors
William C. Culp
Thomas R. Porter
William C. Culp Jr.
Brian N. Vonk
Publication date
01-04-2003
Publisher
Springer-Verlag
Published in
CardioVascular and Interventional Radiology / Issue 2/2003
Print ISSN: 0174-1551
Electronic ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-002-2623-4

Other articles of this Issue 2/2003

CardioVascular and Interventional Radiology 2/2003 Go to the issue