Abstract

Background

Recurrent laryngeal nerve (RLN) palsy ranks among the leading reasons for medicolegal litigation of surgeons because of its attendant reduction in quality of life. As a risk minimization tool, intraoperative nerve monitoring (IONM) has been introduced to verify RLN function integrity intraoperatively. Nevertheless, a systematic evidence-based assessment of this novel health technology has not been performed.

Methods

The present study was based on a systematic appraisal of the literature using evidence-based criteria.

Results

Recurrent laryngeal nerve palsy rates (RLNPR) varied widely after thyroid surgery, ranging from 0%–7.1% for transient RLN palsy to 0%–11% for permanent RLN palsy. These rates did not differ much from those reported for visual nerve identification without the use of IONM. Six studies with more than 100 nerves at risk (NAR) each evaluated RLNPR by contrasting IONM with visual nerve identification only. Recuurent laryngeal nerve palsy rates tended to be lower with IONM than without it, but this difference was not statistically significant. Six additional studies compared IONM findings with their corresponding postoperative laryngoscopic results. Those studies revealed high negative predictive values (NPV; 92%–100%), but relatively low and variable positive predictive values (PPV; 10%–90%) for IONM, limiting its utility for intraoperative RLN management.

Conclusions

Apart from navigating the surgeon through challenging anatomies, IONM may lend itself as a routine adjunct to the gold standard of visual nerve identification. To further reduce the number of false negative IONM signals, the causes underlying its relatively low PPV require additional clarification.
Literature
1.
go back to reference Kern KA (1993) Medicolegal analysis of errors in diagnosis and treatment of surgical endocrine disease. Surgery 114:1167–1174PubMed Kern KA (1993) Medicolegal analysis of errors in diagnosis and treatment of surgical endocrine disease. Surgery 114:1167–1174PubMed
2.
go back to reference Schulte KM, Röher HD (1999) Behandlungsfehler bei Operationen der Schilddrüse. Chirurg 70:1131–1138 PubMedCrossRef Schulte KM, Röher HD (1999) Behandlungsfehler bei Operationen der Schilddrüse. Chirurg 70:1131–1138 PubMedCrossRef
3.
go back to reference Smith E, Taylor M, Mendoza M (1998) Spasmodic dysphonia and vocal fold paralysis: outcomes of voice problems on work-related functioning. J Voice 12:223–232 PubMedCrossRef Smith E, Taylor M, Mendoza M (1998) Spasmodic dysphonia and vocal fold paralysis: outcomes of voice problems on work-related functioning. J Voice 12:223–232 PubMedCrossRef
4.
go back to reference Smith E, Verdolini K, Gray S et al (1996) Effect of voice disorders on quality of life. J Med Speech Language Pathol 4:223–244 Smith E, Verdolini K, Gray S et al (1996) Effect of voice disorders on quality of life. J Med Speech Language Pathol 4:223–244
5.
go back to reference Lamade W, Renz K, Willeke F et al (1999) Effect of training on the incidence of nerve damage in thyroid surgery. Br J Surg 86:388–391 PubMedCrossRef Lamade W, Renz K, Willeke F et al (1999) Effect of training on the incidence of nerve damage in thyroid surgery. Br J Surg 86:388–391 PubMedCrossRef
6.
go back to reference Dralle H, Sekulla C, Haerting J et al (2004) Risk factors of paralysis and functional outcome after recurrent laryngeal nerve monitoring in thyroid surgery. Surgery 136:1310–1322 PubMedCrossRef Dralle H, Sekulla C, Haerting J et al (2004) Risk factors of paralysis and functional outcome after recurrent laryngeal nerve monitoring in thyroid surgery. Surgery 136:1310–1322 PubMedCrossRef
7.
go back to reference Sosa JA, Bowman HM, Tielsch JM et al (1998) The importance of surgeon experience for clinical and economic outcomes from thyroidectomy. Ann Surg 228:320–330PubMedCrossRef Sosa JA, Bowman HM, Tielsch JM et al (1998) The importance of surgeon experience for clinical and economic outcomes from thyroidectomy. Ann Surg 228:320–330PubMedCrossRef
8.
go back to reference Lahey FH (1938) Routine dissection and demonstration of the recurrent laryngeal nerve in subtotal thyroidectomy. Surg Gynecol Obstet 66:775–777 Lahey FH (1938) Routine dissection and demonstration of the recurrent laryngeal nerve in subtotal thyroidectomy. Surg Gynecol Obstet 66:775–777
9.
go back to reference Riddell VH (1956) Injury to recurrent laryngeal nerves during thyroidectomy—a comparison between the results of identification and non-identification in 1022 nerves exposed to risk. Lancet 29:638–641CrossRef Riddell VH (1956) Injury to recurrent laryngeal nerves during thyroidectomy—a comparison between the results of identification and non-identification in 1022 nerves exposed to risk. Lancet 29:638–641CrossRef
10.
go back to reference Hermann M, Alk G, Roka R et al (2002) Laryngeal recurrent nerve injury in surgery for benign thyroid diseases. Ann Surg 235:261–268PubMedCrossRef Hermann M, Alk G, Roka R et al (2002) Laryngeal recurrent nerve injury in surgery for benign thyroid diseases. Ann Surg 235:261–268PubMedCrossRef
11.
go back to reference Jatzko GR, Lisborg PH, Müller MG et al (1994) Recurrent nerve palsy after thyroid operations—principal nerve identification and a literature review. Surgery 115:139–144PubMed Jatzko GR, Lisborg PH, Müller MG et al (1994) Recurrent nerve palsy after thyroid operations—principal nerve identification and a literature review. Surgery 115:139–144PubMed
12.
go back to reference Moley JF, Lairmore TC, Doherty GM et al (1999) Preservation of the recurrent laryngeal nerves in thyroid and parathyroid reoperations. Surgery 125:673–679 Moley JF, Lairmore TC, Doherty GM et al (1999) Preservation of the recurrent laryngeal nerves in thyroid and parathyroid reoperations. Surgery 125:673–679
13.
go back to reference Steurer M, Passler C, Denk DM (2002) Advantages of recurrent laryngeal nerve identification in thyroidectomy and the importance of preoperative and postoperative laryngoscopic examination in more than 1000 nerves at risk. Laryngoscope 112:124–133PubMedCrossRef Steurer M, Passler C, Denk DM (2002) Advantages of recurrent laryngeal nerve identification in thyroidectomy and the importance of preoperative and postoperative laryngoscopic examination in more than 1000 nerves at risk. Laryngoscope 112:124–133PubMedCrossRef
15.
go back to reference Randolph GW (2003) Surgical anatomy of the recurrent laryngeal nerve. In: Randolph GW (ed) Surgery of the Thyroid and Parathyroid Glands. W. B. Saunders, Philadelphia, p. 300–342 Randolph GW (2003) Surgical anatomy of the recurrent laryngeal nerve. In: Randolph GW (ed) Surgery of the Thyroid and Parathyroid Glands. W. B. Saunders, Philadelphia, p. 300–342
16.
go back to reference Snyder SK, Hendricks JC (2005) Intraoperative neurophysiology testing of the recurrent laryngeal nerve: plaudits and pitfalls. Surgery 138:1183–1192PubMedCrossRef Snyder SK, Hendricks JC (2005) Intraoperative neurophysiology testing of the recurrent laryngeal nerve: plaudits and pitfalls. Surgery 138:1183–1192PubMedCrossRef
17.
go back to reference Echeverri A, Flexon PB (1998) Electrophysiologic nerve stimulation for identifying the recurrent laryngeal nerve in thyroid surgery: review of 70 consecutive thyroid surgeries. Am Surg 64:328–333PubMed Echeverri A, Flexon PB (1998) Electrophysiologic nerve stimulation for identifying the recurrent laryngeal nerve in thyroid surgery: review of 70 consecutive thyroid surgeries. Am Surg 64:328–333PubMed
18.
go back to reference Gavilan J, Gavilan C (1986) Recurrent laryngeal nerve. Arch Otolaryngol Head Neck Surg 112:1286–1288PubMed Gavilan J, Gavilan C (1986) Recurrent laryngeal nerve. Arch Otolaryngol Head Neck Surg 112:1286–1288PubMed
19.
go back to reference James AG, Crocker S, Woltering E et al (1985) A simple method for identifying and testing the recurrent laryngeal nerve. Surg Gynecol Obstet 161:185–186PubMed James AG, Crocker S, Woltering E et al (1985) A simple method for identifying and testing the recurrent laryngeal nerve. Surg Gynecol Obstet 161:185–186PubMed
20.
go back to reference Kratz RC (1973) The identification and protection of the laryngeal motor nerves during thyroid and laryngeal surgery: a new microsurgical technique. Laryngoscope 83:59–78PubMedCrossRef Kratz RC (1973) The identification and protection of the laryngeal motor nerves during thyroid and laryngeal surgery: a new microsurgical technique. Laryngoscope 83:59–78PubMedCrossRef
21.
go back to reference Otto RA, Cochran SP (2002) Sensitivity and specificity of intraoperative recurrent laryngeal nerve stimulation in predicting postoperative nerve paralysis. Ann Otol Rhinol Laryngol 111:1005–1007PubMed Otto RA, Cochran SP (2002) Sensitivity and specificity of intraoperative recurrent laryngeal nerve stimulation in predicting postoperative nerve paralysis. Ann Otol Rhinol Laryngol 111:1005–1007PubMed
22.
go back to reference Randolph GW, Kobler JB, Wilkins J (2004) Recurrent laryngeal nerve identification and assessment during thyroid surgery: laryngeal palpation. World J Surg 28:755–760 PubMedCrossRef Randolph GW, Kobler JB, Wilkins J (2004) Recurrent laryngeal nerve identification and assessment during thyroid surgery: laryngeal palpation. World J Surg 28:755–760 PubMedCrossRef
23.
go back to reference Tomoda C, Hirokawa Y, Uruno T (2006) Sensitivity and specificity of intraoperative recurrent laryngeal nerve stimulation test for predicting vocal cord palsy after thyroid surgery. World J Surg 30:1230–1233PubMedCrossRef Tomoda C, Hirokawa Y, Uruno T (2006) Sensitivity and specificity of intraoperative recurrent laryngeal nerve stimulation test for predicting vocal cord palsy after thyroid surgery. World J Surg 30:1230–1233PubMedCrossRef
24.
go back to reference Hvidegaard T, Vase P, Dalsgaard SC, Jorgensen K (1984) Endolaryngeal devices for perioperative identification and functional testing of the recurrent nerve. Otolaryngol Head Neck Surg 92:292–294PubMed Hvidegaard T, Vase P, Dalsgaard SC, Jorgensen K (1984) Endolaryngeal devices for perioperative identification and functional testing of the recurrent nerve. Otolaryngol Head Neck Surg 92:292–294PubMed
25.
go back to reference Sheed DP, Burget GC, Haven N (1966) Identification of the recurrent laryngeal nerve. Arch Surg 92:861–864 Sheed DP, Burget GC, Haven N (1966) Identification of the recurrent laryngeal nerve. Arch Surg 92:861–864
26.
go back to reference Woltering EA, Dumond D, Ferrara J et al (1984) A method for intraoperative identification of the recurrent laryngeal nerve. Am J Surg 148:438–440PubMedCrossRef Woltering EA, Dumond D, Ferrara J et al (1984) A method for intraoperative identification of the recurrent laryngeal nerve. Am J Surg 148:438–440PubMedCrossRef
27.
go back to reference Eltzschig HK, Posner M, Moore FD (2002) The use of readily available equipment in a simple method for intraoperative monitoring of recurrent laryngeal nerve function during thyroid surgery. Arch Surg 137:452–457PubMedCrossRef Eltzschig HK, Posner M, Moore FD (2002) The use of readily available equipment in a simple method for intraoperative monitoring of recurrent laryngeal nerve function during thyroid surgery. Arch Surg 137:452–457PubMedCrossRef
28.
go back to reference Hillermann CL, Tarpey J, Phillips DE (2003) Laryngeal nerve identification during thyroid surgery—feasibility of a novel approach. Can J Anesth 50:189–192PubMed Hillermann CL, Tarpey J, Phillips DE (2003) Laryngeal nerve identification during thyroid surgery—feasibility of a novel approach. Can J Anesth 50:189–192PubMed
29.
go back to reference Premachandra DJ, Radcliffe GJ, Stearns MP (1990) Intraoperative identification of the recurrent laryngeal nerve and demonstration of its function. Laryngoscope 100:94–96PubMed Premachandra DJ, Radcliffe GJ, Stearns MP (1990) Intraoperative identification of the recurrent laryngeal nerve and demonstration of its function. Laryngoscope 100:94–96PubMed
30.
go back to reference Scheuller MC, Ellison D (2002) Laryngeal mask anesthesia with intraoperative laryngoscopy for identification of the recurrent laryngeal nerve during thyroidectomy. Laryngoscope 112:1594–1597 PubMedCrossRef Scheuller MC, Ellison D (2002) Laryngeal mask anesthesia with intraoperative laryngoscopy for identification of the recurrent laryngeal nerve during thyroidectomy. Laryngoscope 112:1594–1597 PubMedCrossRef
31.
go back to reference Bigelow DC, Patterson T, Weber R et al (2002) Comparison of endotrachial tube and hookwire electrodes for monitoring the vagus nerve. J Clin Monit 17:217–220CrossRef Bigelow DC, Patterson T, Weber R et al (2002) Comparison of endotrachial tube and hookwire electrodes for monitoring the vagus nerve. J Clin Monit 17:217–220CrossRef
32.
go back to reference Davis WE, Rea JL, Templer J (1979) Recurrent laryngeal nerve localization using a microlaryngeal electrode. Otolaryngol Head Neck Surg 87:330–333PubMed Davis WE, Rea JL, Templer J (1979) Recurrent laryngeal nerve localization using a microlaryngeal electrode. Otolaryngol Head Neck Surg 87:330–333PubMed
33.
go back to reference Lipton RJ, McCaffrey TV, Litchy WJ (1988) Intraoperative electrophysiologic monitoring of laryngeal muscle during thyroid surgery. Laryngoscope 98:1292–1296PubMedCrossRef Lipton RJ, McCaffrey TV, Litchy WJ (1988) Intraoperative electrophysiologic monitoring of laryngeal muscle during thyroid surgery. Laryngoscope 98:1292–1296PubMedCrossRef
34.
go back to reference Maloney RW, Murcek BW, Steehler KW et al (1994) A new method for intraoperative recurrent laryngeal nerve monitoring. ENT J 73:30–33 Maloney RW, Murcek BW, Steehler KW et al (1994) A new method for intraoperative recurrent laryngeal nerve monitoring. ENT J 73:30–33
35.
go back to reference Rice DH, Cone Wesson B (1991) Intraoperative recurrent laryngeal nerve monitoring. Otolaryngol Head Neck Surg 105:372–375PubMed Rice DH, Cone Wesson B (1991) Intraoperative recurrent laryngeal nerve monitoring. Otolaryngol Head Neck Surg 105:372–375PubMed
36.
go back to reference Tschopp K, Probst R (1994) Neue Aspekte in der Schilddrüsenchirurgie mit dem intraoperativen Neuromonitoring des N. laryngeus recurrens. Laryngo Rhino Otol 73:568–572CrossRef Tschopp K, Probst R (1994) Neue Aspekte in der Schilddrüsenchirurgie mit dem intraoperativen Neuromonitoring des N. laryngeus recurrens. Laryngo Rhino Otol 73:568–572CrossRef
37.
go back to reference Yarbrough DE, Thompson GB, Kasperbauer JL et al (2004) Intraoperative electromyographic monitoring of the recurrent laryngeal nerve in reoperative thyroid and parathyroid surgery. Surgery 136:1107–1115 PubMedCrossRef Yarbrough DE, Thompson GB, Kasperbauer JL et al (2004) Intraoperative electromyographic monitoring of the recurrent laryngeal nerve in reoperative thyroid and parathyroid surgery. Surgery 136:1107–1115 PubMedCrossRef
38.
go back to reference Brauckhoff M, Gimm O, Thanh PN (2002) First experiences in intraoperative neurostimulation of the recurrent laryngeal nerve during thyroid surgery of children and adolescents. J Pediatr Surg 37:1414–1418PubMedCrossRef Brauckhoff M, Gimm O, Thanh PN (2002) First experiences in intraoperative neurostimulation of the recurrent laryngeal nerve during thyroid surgery of children and adolescents. J Pediatr Surg 37:1414–1418PubMedCrossRef
39.
go back to reference Brauckhoff M, Thanh NP, Dralle H (2004) Images in thyroidology—nervus laryngeus inferior non recurrens and lusorial artery. Thyroid 14:79–81PubMedCrossRef Brauckhoff M, Thanh NP, Dralle H (2004) Images in thyroidology—nervus laryngeus inferior non recurrens and lusorial artery. Thyroid 14:79–81PubMedCrossRef
40.
go back to reference Brauckhoff M, Walls G, Brauckhoff K (2002) Identification of the non-recurrent inferior laryngeal nerve using intraoperative neurostimulation. Langenbecks Arch Surg 386:482–487PubMedCrossRef Brauckhoff M, Walls G, Brauckhoff K (2002) Identification of the non-recurrent inferior laryngeal nerve using intraoperative neurostimulation. Langenbecks Arch Surg 386:482–487PubMedCrossRef
41.
go back to reference Hamelmann WH, Meyer T, Timm S et al (2002) Kritische Beurteilung und Fehlermöglichkeiten des intraoperativen Neuromonitorings (IONM) bei Operationen an der Schilddrüse. Zentralbl Chir 127:409–413PubMedCrossRef Hamelmann WH, Meyer T, Timm S et al (2002) Kritische Beurteilung und Fehlermöglichkeiten des intraoperativen Neuromonitorings (IONM) bei Operationen an der Schilddrüse. Zentralbl Chir 127:409–413PubMedCrossRef
42.
go back to reference Hermann M, Hellebart C, Freissmuth M (2004) Neuromonitoring in thyroid surgery—prospective evaluation of intraoperative electrophysiological response for the prediction of recurrent laryngeal nerve injury. Ann Surg 240:9–17PubMedCrossRef Hermann M, Hellebart C, Freissmuth M (2004) Neuromonitoring in thyroid surgery—prospective evaluation of intraoperative electrophysiological response for the prediction of recurrent laryngeal nerve injury. Ann Surg 240:9–17PubMedCrossRef
43.
go back to reference Jonas J, Bähr R (2006) Intraoperative Neuromonitoring des Nervus laryngeus recurrens - Ergebnisse und Lernkurve. Zentralbl Chir 131:443–448PubMedCrossRef Jonas J, Bähr R (2006) Intraoperative Neuromonitoring des Nervus laryngeus recurrens - Ergebnisse und Lernkurve. Zentralbl Chir 131:443–448PubMedCrossRef
44.
go back to reference Kunath M, Marusch F, Horschig P et al (2003) Zum Stellenwert des intraoperativen Neuromonitorings in der Schilddrüsenchirurgie—eine prospective Beobachtungsstudie mit 926 Patienten. Zentralbl Chir 128:187–190PubMedCrossRef Kunath M, Marusch F, Horschig P et al (2003) Zum Stellenwert des intraoperativen Neuromonitorings in der Schilddrüsenchirurgie—eine prospective Beobachtungsstudie mit 926 Patienten. Zentralbl Chir 128:187–190PubMedCrossRef
45.
go back to reference Spahn JG, Bizal J, Ferguson S et al (1981) Identification of the motor laryngeal nerves—a new electrical stimulation technique. Laryngoscope 91:1865–1868PubMedCrossRef Spahn JG, Bizal J, Ferguson S et al (1981) Identification of the motor laryngeal nerves—a new electrical stimulation technique. Laryngoscope 91:1865–1868PubMedCrossRef
46.
go back to reference Thomusch O, Sekulla C, Machens A et al (2004) Validity of intra-operative neuromonitoring signals in thyroid surgery. Langenbecks Arch Surg 389:499–503PubMedCrossRef Thomusch O, Sekulla C, Machens A et al (2004) Validity of intra-operative neuromonitoring signals in thyroid surgery. Langenbecks Arch Surg 389:499–503PubMedCrossRef
47.
go back to reference Thomusch O, Sekulla C, Walls G et al (2002) Intraoperative neuromonitoring of surgery for benign goiter. Am J Surg 183:673–678PubMedCrossRef Thomusch O, Sekulla C, Walls G et al (2002) Intraoperative neuromonitoring of surgery for benign goiter. Am J Surg 183:673–678PubMedCrossRef
48.
go back to reference Tschopp KP, Gottardo C (2002) Comparison of various methods of electromyographic monitoring of the recurrent laryngeal nerve in thyroid surgery. Ann Otol Rhinol Laryngol 111:811–816PubMed Tschopp KP, Gottardo C (2002) Comparison of various methods of electromyographic monitoring of the recurrent laryngeal nerve in thyroid surgery. Ann Otol Rhinol Laryngol 111:811–816PubMed
49.
go back to reference Bailleux S, Bozbc A, Cstillo L et al (2006) Thyroid surgery and recurrent laryngeal nerve monitoringJ Laryngol Otol 120:566–599 Bailleux S, Bozbc A, Cstillo L et al (2006) Thyroid surgery and recurrent laryngeal nerve monitoringJ Laryngol Otol 120:566–599
50.
go back to reference Barwell J, Lytle J, Page R et al (1997) The NIM-2 nerve integrity monitor in thyroid and parathyroid surgery. Br J Surg 84:854PubMedCrossRef Barwell J, Lytle J, Page R et al (1997) The NIM-2 nerve integrity monitor in thyroid and parathyroid surgery. Br J Surg 84:854PubMedCrossRef
51.
go back to reference Beldi G, Kinsbergen T, Schlumpf R (2004) Evaluation of intraoperative recurrent nerve monitoring in thyroid surgery. World J Surg 28:589–591 PubMedCrossRef Beldi G, Kinsbergen T, Schlumpf R (2004) Evaluation of intraoperative recurrent nerve monitoring in thyroid surgery. World J Surg 28:589–591 PubMedCrossRef
52.
go back to reference Brennan J, Moore EJ, Schuler KJ (2001) Prospective analysis of the efficacy of continuous intraoperative nerve monitoring during thyroidectomy, parathyroidectomy, and parotidectomy. Otolaryngol Head Neck Surg 124:537–543 PubMedCrossRef Brennan J, Moore EJ, Schuler KJ (2001) Prospective analysis of the efficacy of continuous intraoperative nerve monitoring during thyroidectomy, parathyroidectomy, and parotidectomy. Otolaryngol Head Neck Surg 124:537–543 PubMedCrossRef
53.
go back to reference Chan WF, Lo CY (2001) Pitfalls of intraoperative neuromonitoring for predicting postoperative recurrent laryngeal nerve function during thyroidectomy. World J Surg 30:806–812 CrossRef Chan WF, Lo CY (2001) Pitfalls of intraoperative neuromonitoring for predicting postoperative recurrent laryngeal nerve function during thyroidectomy. World J Surg 30:806–812 CrossRef
54.
go back to reference Chan WF, Lang BHH, Lo CY (2006) The role of intraoperative neuromonitoring of recurrent laryngeal nerve during thyroidectomy: a comparative study on 1000 nerves at risk. Surgery 140:866–873PubMedCrossRef Chan WF, Lang BHH, Lo CY (2006) The role of intraoperative neuromonitoring of recurrent laryngeal nerve during thyroidectomy: a comparative study on 1000 nerves at risk. Surgery 140:866–873PubMedCrossRef
55.
go back to reference Dackiw APB, Rotstein LE, Clark OH (2002) Computer-assisted evoked electromyography with stimulating surgical instruments for recurrent/external laryngeal nerve identification and preservation in thyroid and parathyroid operation. Surgery 132:1100–1108PubMedCrossRef Dackiw APB, Rotstein LE, Clark OH (2002) Computer-assisted evoked electromyography with stimulating surgical instruments for recurrent/external laryngeal nerve identification and preservation in thyroid and parathyroid operation. Surgery 132:1100–1108PubMedCrossRef
56.
go back to reference Djohan RS, Rodriguez HE, Connolly MM et al (2000) Intraoperative monitoring of recurrent laryngeal nerve function. Am Surg 66:595–597PubMed Djohan RS, Rodriguez HE, Connolly MM et al (2000) Intraoperative monitoring of recurrent laryngeal nerve function. Am Surg 66:595–597PubMed
57.
go back to reference Eisele DW (1996) Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve. Laryngoscope 106:442–449 CrossRef Eisele DW (1996) Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve. Laryngoscope 106:442–449 CrossRef
58.
go back to reference Hemmerling TM, Schmidt J, Bosert C et al (2001) Intraoperative monitoring of the recurrent laryngeal nerve in 151 consecutive patients undergoing thyroid surgery. Anesth Analg 193:396–399CrossRef Hemmerling TM, Schmidt J, Bosert C et al (2001) Intraoperative monitoring of the recurrent laryngeal nerve in 151 consecutive patients undergoing thyroid surgery. Anesth Analg 193:396–399CrossRef
59.
go back to reference Horn D, Rötzscher V (1999) Intraoperative electromyogram monitoring of the recurrent laryngeal nerve: experience with an intralaryngeal surface electrode—a method to reduce the risk of recurrent laryngeal nerve injury during thyroid surgery. Langenbecks Arch Surg 384:392–395PubMedCrossRef Horn D, Rötzscher V (1999) Intraoperative electromyogram monitoring of the recurrent laryngeal nerve: experience with an intralaryngeal surface electrode—a method to reduce the risk of recurrent laryngeal nerve injury during thyroid surgery. Langenbecks Arch Surg 384:392–395PubMedCrossRef
60.
go back to reference Khan A, Pearlman RC, Bianchi DA et al (1997) Experience with two types of electromyography monitoring electrodes during thyroid surgery. Am J Otol 18:99–102CrossRef Khan A, Pearlman RC, Bianchi DA et al (1997) Experience with two types of electromyography monitoring electrodes during thyroid surgery. Am J Otol 18:99–102CrossRef
61.
go back to reference Lambert AW, Cosgrove C, Barwell J et al (2000) Vagus nerve stimulation: quality control in thyroid and parathyroid surgery. J Laryngol Otol 114:125–127 PubMedCrossRef Lambert AW, Cosgrove C, Barwell J et al (2000) Vagus nerve stimulation: quality control in thyroid and parathyroid surgery. J Laryngol Otol 114:125–127 PubMedCrossRef
62.
go back to reference Mermelstein M, Nonweiler R, Rubinstein EH (1996) Intraoperative identification of laryngeal nerves with laryngeal electromyography. Laryngoscope 106:752–756PubMedCrossRef Mermelstein M, Nonweiler R, Rubinstein EH (1996) Intraoperative identification of laryngeal nerves with laryngeal electromyography. Laryngoscope 106:752–756PubMedCrossRef
63.
go back to reference Pearlman RC, Isley MR, Ruben GD et al (2005) Intraoperative monitoring of the recurrent laryngeal nerve using acoustic, free-run, and evoked electromyography. J Clin Neurophysiol 22:148–152PubMedCrossRef Pearlman RC, Isley MR, Ruben GD et al (2005) Intraoperative monitoring of the recurrent laryngeal nerve using acoustic, free-run, and evoked electromyography. J Clin Neurophysiol 22:148–152PubMedCrossRef
64.
go back to reference Rea LJ, Khan A (1998) Clinical evoked electromyography for recurrent laryngeal nerve preservation: use of an endotracheal tube electrode and a postcricoid surface electrode. Laryngoscope 108:1418–1420PubMedCrossRef Rea LJ, Khan A (1998) Clinical evoked electromyography for recurrent laryngeal nerve preservation: use of an endotracheal tube electrode and a postcricoid surface electrode. Laryngoscope 108:1418–1420PubMedCrossRef
65.
go back to reference Robertson ML, Steward DL, Gluckman JL et al (2004) Continuous laryngeal nerve integrity monitoring during thyroidectomy: does it reduce risk of injuy? Otolaryngol Head Neck Surg 131:596–600PubMedCrossRef Robertson ML, Steward DL, Gluckman JL et al (2004) Continuous laryngeal nerve integrity monitoring during thyroidectomy: does it reduce risk of injuy? Otolaryngol Head Neck Surg 131:596–600PubMedCrossRef
66.
go back to reference Shindo M, Chheda NN (2007) Incidence of vocal cord paralysis with and without recurrent laryngeal nerve monitoring during thyroidectomy. Arch Otolaryngol Head Neck Surg 133:481–485 PubMedCrossRef Shindo M, Chheda NN (2007) Incidence of vocal cord paralysis with and without recurrent laryngeal nerve monitoring during thyroidectomy. Arch Otolaryngol Head Neck Surg 133:481–485 PubMedCrossRef
67.
go back to reference Srinivasan V, Premachandra DJ (1998) Use of a disposable electrode for recurrent laryngeal nerve monitoring. J Laryngol Otol 112:561–564PubMed Srinivasan V, Premachandra DJ (1998) Use of a disposable electrode for recurrent laryngeal nerve monitoring. J Laryngol Otol 112:561–564PubMed
68.
go back to reference Timon CI, Rafferty M (1999) Nerve monitoring in thyroid surgery: is it worthwhile? Clin Otolaryngol 24:487–490CrossRefPubMed Timon CI, Rafferty M (1999) Nerve monitoring in thyroid surgery: is it worthwhile? Clin Otolaryngol 24:487–490CrossRefPubMed
69.
go back to reference Jonas J (2002) Wie zuverlässig ist das Neuromonitoring des Nervus laryngeus recurrens in der Schilddrüsenchirurgie? Zentralbl Chir 127:404–408PubMedCrossRef Jonas J (2002) Wie zuverlässig ist das Neuromonitoring des Nervus laryngeus recurrens in der Schilddrüsenchirurgie? Zentralbl Chir 127:404–408PubMedCrossRef
70.
go back to reference Dralle H, Kruse E, Hamelmann WH et al (2004) Nicht jeder Stimmlippenstillstand nach Schilddrüsenoperation ist eine chirurgisch bedingte Rekurrensparese. Chirurg 75:810–822PubMed Dralle H, Kruse E, Hamelmann WH et al (2004) Nicht jeder Stimmlippenstillstand nach Schilddrüsenoperation ist eine chirurgisch bedingte Rekurrensparese. Chirurg 75:810–822PubMed
71.
go back to reference Koester M, Zorowka P, Wolf S (2003) Neuromonitoring in thyroid surgery: The view of the laryngologist. Eur Surg 35:246–249CrossRef Koester M, Zorowka P, Wolf S (2003) Neuromonitoring in thyroid surgery: The view of the laryngologist. Eur Surg 35:246–249CrossRef
72.
go back to reference Sackett DL (1989) Rules of evidence and clinical recommendations on the use of antithrombotic agents. Chest 95:2–4CrossRef Sackett DL (1989) Rules of evidence and clinical recommendations on the use of antithrombotic agents. Chest 95:2–4CrossRef
73.
go back to reference Heinrich S, Schäfer M, Rousson M et al (2006) Evidence-based treatment of acute pancreatitis: a look at established paradigms. Ann Surg 243:154–168PubMedCrossRef Heinrich S, Schäfer M, Rousson M et al (2006) Evidence-based treatment of acute pancreatitis: a look at established paradigms. Ann Surg 243:154–168PubMedCrossRef
74.
go back to reference Rosato L, Avenia N, Bernante P et al (2004) Complications of thyroid surgery: analysis of a multicentric study on 14,934 patients operated on in Italy over 5 years. World J Surg 28:271–276 PubMedCrossRef Rosato L, Avenia N, Bernante P et al (2004) Complications of thyroid surgery: analysis of a multicentric study on 14,934 patients operated on in Italy over 5 years. World J Surg 28:271–276 PubMedCrossRef
75.
go back to reference Pauslen FP, Rudert HH, Tillmann BN (2000) New insights into the pathomechanism of postintubation arythenoid subluxation. Anesthesiology 92:1507–1507CrossRef Pauslen FP, Rudert HH, Tillmann BN (2000) New insights into the pathomechanism of postintubation arythenoid subluxation. Anesthesiology 92:1507–1507CrossRef
76.
go back to reference Marusch F, Hussock J, Haring G (2005) Influence of muscle relaxation on neuromonitoring of the recurrent laryngeal nerve during thyroid surgery. Br J Anaesth 94:596–600PubMedCrossRef Marusch F, Hussock J, Haring G (2005) Influence of muscle relaxation on neuromonitoring of the recurrent laryngeal nerve during thyroid surgery. Br J Anaesth 94:596–600PubMedCrossRef
77.
go back to reference Marcus B, Edwards B, Yoo S et al (2003) Recurrent laryngeal nerve monitoring in thyroid and parathyroid surgery: the University of Michigan experience. Laryngoscope 113:356–361PubMedCrossRef Marcus B, Edwards B, Yoo S et al (2003) Recurrent laryngeal nerve monitoring in thyroid and parathyroid surgery: the University of Michigan experience. Laryngoscope 113:356–361PubMedCrossRef
78.
go back to reference Francois B, Bellissant E, Gissot V et al (2007) P12-h pretreatment with methylprednisolone versus placebo for prevention of postextubation laryngeal oedema: a randomized double-blind trial. Lancet 369:1083–1089PubMedCrossRef Francois B, Bellissant E, Gissot V et al (2007) P12-h pretreatment with methylprednisolone versus placebo for prevention of postextubation laryngeal oedema: a randomized double-blind trial. Lancet 369:1083–1089PubMedCrossRef
79.
go back to reference Wang LF, Lee KW, Ruo WR et al (2006) The efficacy of intraoperative corticosteroids in recurrent laryngeal nerve palsy after thyroid surgery. World J Surg 30:299–303PubMedCrossRef Wang LF, Lee KW, Ruo WR et al (2006) The efficacy of intraoperative corticosteroids in recurrent laryngeal nerve palsy after thyroid surgery. World J Surg 30:299–303PubMedCrossRef
Metadata
Title
Intraoperative Monitoring of the Recurrent Laryngeal Nerve in Thyroid Surgery
Authors
H. Dralle
C. Sekulla
K. Lorenz
M. Brauckhoff
A. Machens
the German IONM Study Group
Publication date
01-07-2008
Publisher
Springer-Verlag
Published in
World Journal of Surgery / Issue 7/2008
Print ISSN: 0364-2313
Electronic ISSN: 1432-2323
DOI
https://doi.org/10.1007/s00268-008-9483-2

Other articles of this Issue 7/2008

World Journal of Surgery 7/2008 Go to the issue