Abstract

Background

In this era of expanding life expectancy and popularity of aesthetic breast surgeries, more women are likely to live more years with their augmented breasts. Thus, consistent attention to general breast health is crucial, and preoperative ultrasound is helpful to locate suspicious lesions. In this study, we present a combinative procedure of augmentation mammoplasty and vacuum-assisted breast biopsy (VABB).

Methods

From January of 2018 to December of 2019, a total of 102 patients received simultaneous augmentation mammoplasty and VABB in our institute. Only patients of primary augmentation mammoplasty who received VABB on unilateral breasts were included. We sought to investigate the results of each breast and safety of adding VABB before performing augmentation within the same incision.

Results

Among 204 breasts and implants, 28.43% were done via endoscopic transaxillary approach and 71.57% via inframammary approach. The mean implant volume was 329.34 ± 44.79 ml, and the mean follow-up period was 14.23 ± 4.64 months. All of the complication rates exhibited no statistically significant differences between the two groups.

Conclusion

Simultaneous augmentation mammoplasty and VABB prevented unnecessary scars and pain, and the complication rates did not statistically differ from those of augmentation only group. This co-operation is a safe and simple method potentially beneficial to many women interested in breast surgery.

Level of Evidence III

This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.​springer.​com/​00266.
Literature
1.
go back to reference Lee DW, Kim SJ, Kim H (2019) Endoscopic transaxillary versus inframammary approaches for breast augmentation using shaped implants: a matched case-control study. Aesthet Plast Surg 43(3):563–568CrossRef Lee DW, Kim SJ, Kim H (2019) Endoscopic transaxillary versus inframammary approaches for breast augmentation using shaped implants: a matched case-control study. Aesthet Plast Surg 43(3):563–568CrossRef
2.
go back to reference Ozalp B, Aydinol M (2017) Breast augmentation combining fat injection and breast implants in patients with atrophied breasts. Ann Plast Surg 78(6):623–628CrossRef Ozalp B, Aydinol M (2017) Breast augmentation combining fat injection and breast implants in patients with atrophied breasts. Ann Plast Surg 78(6):623–628CrossRef
3.
go back to reference Heidekrueger PI, Sinno S, Hidalgo DA, Colombo M, Broer PN (2018) Current trends in breast augmentation: an international analysis. Aesthet Surg J 38(2):133–148CrossRef Heidekrueger PI, Sinno S, Hidalgo DA, Colombo M, Broer PN (2018) Current trends in breast augmentation: an international analysis. Aesthet Surg J 38(2):133–148CrossRef
5.
go back to reference Rojas K, Stuckey A (2016) Breast cancer epidemiology and risk factors. Clin Obstet Gynecol 59(4):651–672CrossRef Rojas K, Stuckey A (2016) Breast cancer epidemiology and risk factors. Clin Obstet Gynecol 59(4):651–672CrossRef
6.
go back to reference Feuer EJ, Wun LM, Boring CC, Flanders WD, Timmel MJ, Tong T (1993) The lifetime risk of developing breast cancer. J Natl Cancer Inst 85(11):892–897CrossRef Feuer EJ, Wun LM, Boring CC, Flanders WD, Timmel MJ, Tong T (1993) The lifetime risk of developing breast cancer. J Natl Cancer Inst 85(11):892–897CrossRef
8.
go back to reference Brem RF, Lenihan MJ, Lieberman J, Torrente J (2015) Screening breast ultrasound: past, present, and future. AJR Am J Roentgenol 204(2):234–240CrossRef Brem RF, Lenihan MJ, Lieberman J, Torrente J (2015) Screening breast ultrasound: past, present, and future. AJR Am J Roentgenol 204(2):234–240CrossRef
9.
go back to reference Berg WA, Gilbreath PL (2000) Multicentric and multifocal cancer: whole-breast US in preoperative evaluation. Radiology 214(1):59–66CrossRef Berg WA, Gilbreath PL (2000) Multicentric and multifocal cancer: whole-breast US in preoperative evaluation. Radiology 214(1):59–66CrossRef
10.
go back to reference Kolb TM, Lichy J, Newhouse JH (1998) Occult cancer in women with dense breasts: detection with screening US–diagnostic yield and tumor characteristics. Radiology 207(1):191–199CrossRef Kolb TM, Lichy J, Newhouse JH (1998) Occult cancer in women with dense breasts: detection with screening US–diagnostic yield and tumor characteristics. Radiology 207(1):191–199CrossRef
11.
go back to reference McIntosh SA, Horgan K (2008) Augmentation mammoplasty: effect on diagnosis of breast cancer. J Plast Reconstr Aesthet Surg 61(2):124–129CrossRef McIntosh SA, Horgan K (2008) Augmentation mammoplasty: effect on diagnosis of breast cancer. J Plast Reconstr Aesthet Surg 61(2):124–129CrossRef
12.
go back to reference Etzioni R, Urban N, Ramsey S, McIntosh M, Schwartz S, Reid B, Radich J, Anderson G, Hartwell L (2003) The case for early detection. Nat Rev Cancer 3(4):243–252CrossRef Etzioni R, Urban N, Ramsey S, McIntosh M, Schwartz S, Reid B, Radich J, Anderson G, Hartwell L (2003) The case for early detection. Nat Rev Cancer 3(4):243–252CrossRef
13.
go back to reference Qu S, Zhang W, Zhang J, Zhang Q, Lu R, Wang N (2019) The vacuum-assisted breast biopsy system is an effective treatment strategy for breast lumps after augmentation with autologous fat grafting. Aesthet Plast Surg 43(5):1152–1157CrossRef Qu S, Zhang W, Zhang J, Zhang Q, Lu R, Wang N (2019) The vacuum-assisted breast biopsy system is an effective treatment strategy for breast lumps after augmentation with autologous fat grafting. Aesthet Plast Surg 43(5):1152–1157CrossRef
14.
go back to reference Nakano S, Imawari Y, Mibu A, Otsuka M, Oinuma T (2018) Differentiating vacuum-assisted breast biopsy from core needle biopsy: is it necessary? Br J Radiol 91(1092):20180250CrossRef Nakano S, Imawari Y, Mibu A, Otsuka M, Oinuma T (2018) Differentiating vacuum-assisted breast biopsy from core needle biopsy: is it necessary? Br J Radiol 91(1092):20180250CrossRef
15.
go back to reference Wang T, Zhu L (2020) Mammotome-assisted removal with minimal incision of large juvenile fibroadenoma of breast: a case report. Medicine (Baltimore) 99(10):e19442CrossRef Wang T, Zhu L (2020) Mammotome-assisted removal with minimal incision of large juvenile fibroadenoma of breast: a case report. Medicine (Baltimore) 99(10):e19442CrossRef
16.
go back to reference Grady I, Gorsuch H, Wilburn-Bailey S (2008) Long-term outcome of benign fibroadenomas treated by ultrasound-guided percutaneous excision. Breast J 14(3):275–278CrossRef Grady I, Gorsuch H, Wilburn-Bailey S (2008) Long-term outcome of benign fibroadenomas treated by ultrasound-guided percutaneous excision. Breast J 14(3):275–278CrossRef
17.
go back to reference Bozzini A, Cassano E, Raciti D, Disalvatore D, Pala O, Vingiani A, Renne G (2018) Analysis of efficacy and accuracy of 2 vacuum-assisted breast biopsy devices: mammotome and elite. Clin Breast Cancer 18(6):e1277–e1282CrossRef Bozzini A, Cassano E, Raciti D, Disalvatore D, Pala O, Vingiani A, Renne G (2018) Analysis of efficacy and accuracy of 2 vacuum-assisted breast biopsy devices: mammotome and elite. Clin Breast Cancer 18(6):e1277–e1282CrossRef
18.
go back to reference Sperber F, Blank A, Metser U, Flusser G, Klausner JM, Lev-Chelouche D (2003) Diagnosis and treatment of breast fibroadenomas by ultrasound-guided vacuum-assisted biopsy. Arch Surg 138(7):796–800CrossRef Sperber F, Blank A, Metser U, Flusser G, Klausner JM, Lev-Chelouche D (2003) Diagnosis and treatment of breast fibroadenomas by ultrasound-guided vacuum-assisted biopsy. Arch Surg 138(7):796–800CrossRef
19.
go back to reference Sie A, Bryan DC, Gaines V, Killebrew LK, Kim CH, Morrison CC, Poller WR, Romilly AP, Schilling K, Sung JH (2006) Multicenter evaluation of the breast lesion excision system, a percutaneous, vacuum-assisted, intact-specimen breast biopsy device. Cancer 107(5):945–949CrossRef Sie A, Bryan DC, Gaines V, Killebrew LK, Kim CH, Morrison CC, Poller WR, Romilly AP, Schilling K, Sung JH (2006) Multicenter evaluation of the breast lesion excision system, a percutaneous, vacuum-assisted, intact-specimen breast biopsy device. Cancer 107(5):945–949CrossRef
20.
go back to reference Johnson AT, Henry-Tillman RS, Smith LF, Harshfield D, Korourian S, Brown H, Lane S, Colvert M, Klimberg VS (2002) Percutaneous excisional breast biopsy. Am J Surg 184(6):550–554 (discussion 554)CrossRef Johnson AT, Henry-Tillman RS, Smith LF, Harshfield D, Korourian S, Brown H, Lane S, Colvert M, Klimberg VS (2002) Percutaneous excisional breast biopsy. Am J Surg 184(6):550–554 (discussion 554)CrossRef
21.
go back to reference Povoski SP, Jimenez RE (2007) A comprehensive evaluation of the 8-gauge vacuum-assisted Mammotome(R) system for ultrasound-guided diagnostic biopsy and selective excision of breast lesions. World J Surg Oncol 5:83CrossRef Povoski SP, Jimenez RE (2007) A comprehensive evaluation of the 8-gauge vacuum-assisted Mammotome(R) system for ultrasound-guided diagnostic biopsy and selective excision of breast lesions. World J Surg Oncol 5:83CrossRef
22.
go back to reference Fang M, Liu G, Luo G, Wu T (2019) Feasibility and safety of image-guided vacuum-assisted breast biopsy: a PRISMA-compliant systematic review and meta-analysis of 20,000 population from 36 longitudinal studies. Int Wound J 16(6):1506–1512CrossRef Fang M, Liu G, Luo G, Wu T (2019) Feasibility and safety of image-guided vacuum-assisted breast biopsy: a PRISMA-compliant systematic review and meta-analysis of 20,000 population from 36 longitudinal studies. Int Wound J 16(6):1506–1512CrossRef
23.
go back to reference Pagni P, Spunticchia F, Barberi S, Caprio G, Paglicci C (2014) Use of core needle biopsy rather than fine-needle aspiration cytology in the diagnostic approach of breast cancer. Case Rep Oncol 7(2):452–458CrossRef Pagni P, Spunticchia F, Barberi S, Caprio G, Paglicci C (2014) Use of core needle biopsy rather than fine-needle aspiration cytology in the diagnostic approach of breast cancer. Case Rep Oncol 7(2):452–458CrossRef
24.
go back to reference Yi W, Xu F, Zou Q, Tang Z (2013) Completely removing solitary intraductal papillomas using the Mammotome system guided by ultrasonography is feasible and safe. World J Surg 37(11):2613–2617CrossRef Yi W, Xu F, Zou Q, Tang Z (2013) Completely removing solitary intraductal papillomas using the Mammotome system guided by ultrasonography is feasible and safe. World J Surg 37(11):2613–2617CrossRef
25.
go back to reference Steiert AE, Boyce M, Sorg H (2013) Capsular contracture by silicone breast implants: possible causes, biocompatibility, and prophylactic strategies. Med Dev (Auckl) 6:211–218 Steiert AE, Boyce M, Sorg H (2013) Capsular contracture by silicone breast implants: possible causes, biocompatibility, and prophylactic strategies. Med Dev (Auckl) 6:211–218
26.
go back to reference Chong SJ, Deva AK (2015) Understanding the etiology and prevention of capsular contracture: translating science into practice. Clin Plast Surg 42(4):427–436CrossRef Chong SJ, Deva AK (2015) Understanding the etiology and prevention of capsular contracture: translating science into practice. Clin Plast Surg 42(4):427–436CrossRef
27.
go back to reference Adams WP Jr, Culbertson EJ, Deva AK, Magnusson RM, Layt C, Jewell ML, Mallucci P, Heden P (2017) Macrotextured breast implants with defined steps to minimize bacterial contamination around the device: experience in 42,000 implants. Plast Reconstr Surg 140(3):427–431CrossRef Adams WP Jr, Culbertson EJ, Deva AK, Magnusson RM, Layt C, Jewell ML, Mallucci P, Heden P (2017) Macrotextured breast implants with defined steps to minimize bacterial contamination around the device: experience in 42,000 implants. Plast Reconstr Surg 140(3):427–431CrossRef
28.
go back to reference Stevens WG, Calobrace MB, Harrington J, Alizadeh K, Zeidler KR, d’Incelli RC (2016) Nine-year core study data for Sientra’s FDA-approved round and shaped implants with high-strength cohesive silicone gel. Aesthet Surg J 36(4):404–416CrossRef Stevens WG, Calobrace MB, Harrington J, Alizadeh K, Zeidler KR, d’Incelli RC (2016) Nine-year core study data for Sientra’s FDA-approved round and shaped implants with high-strength cohesive silicone gel. Aesthet Surg J 36(4):404–416CrossRef
29.
go back to reference Spear SL, Murphy DK (2014) Natrelle round silicone breast implants: core Study results at 10 years. Plast Reconstr Surg 133(6):1354–1361CrossRef Spear SL, Murphy DK (2014) Natrelle round silicone breast implants: core Study results at 10 years. Plast Reconstr Surg 133(6):1354–1361CrossRef
30.
go back to reference Caplin DA (2014) Indications for the use of MemoryShape breast implants in aesthetic and reconstructive breast surgery: long-term clinical outcomes of shaped versus round silicone breast implants. Plast Reconstr Surg 134(3 Suppl):27S–37SCrossRef Caplin DA (2014) Indications for the use of MemoryShape breast implants in aesthetic and reconstructive breast surgery: long-term clinical outcomes of shaped versus round silicone breast implants. Plast Reconstr Surg 134(3 Suppl):27S–37SCrossRef
31.
go back to reference Maxwell GP, Van Natta BW, Bengtson BP, Murphy DK (2015) Ten-year results from the Natrelle 410 anatomical form-stable silicone breast implant core study. Aesthet Surg J 35(2):145–155CrossRef Maxwell GP, Van Natta BW, Bengtson BP, Murphy DK (2015) Ten-year results from the Natrelle 410 anatomical form-stable silicone breast implant core study. Aesthet Surg J 35(2):145–155CrossRef
32.
go back to reference Blount AL, Martin MD, Lineberry KD, Kettaneh N, Alfonso DR (2013) Capsular contracture rate in a low-risk population after primary augmentation mammaplasty. Aesthet Surg J 33(4):516–521CrossRef Blount AL, Martin MD, Lineberry KD, Kettaneh N, Alfonso DR (2013) Capsular contracture rate in a low-risk population after primary augmentation mammaplasty. Aesthet Surg J 33(4):516–521CrossRef
33.
go back to reference Namnoum JD, Largent J, Kaplan HM, Oefelein MG, Brown MH (2013) Primary breast augmentation clinical trial outcomes stratified by surgical incision, anatomical placement and implant device type. J Plast Reconstr Aesthet Surg 66(9):1165–1172CrossRef Namnoum JD, Largent J, Kaplan HM, Oefelein MG, Brown MH (2013) Primary breast augmentation clinical trial outcomes stratified by surgical incision, anatomical placement and implant device type. J Plast Reconstr Aesthet Surg 66(9):1165–1172CrossRef
34.
go back to reference Stevens WG, Nahabedian MY, Calobrace MB, Harrington JL, Capizzi PJ, Cohen R, d’Incelli RC, Beckstrand M (2013) Risk factor analysis for capsular contracture: a 5-year Sientra study analysis using round, smooth, and textured implants for breast augmentation. Plast Reconstr Surg 132(5):1115–1123CrossRef Stevens WG, Nahabedian MY, Calobrace MB, Harrington JL, Capizzi PJ, Cohen R, d’Incelli RC, Beckstrand M (2013) Risk factor analysis for capsular contracture: a 5-year Sientra study analysis using round, smooth, and textured implants for breast augmentation. Plast Reconstr Surg 132(5):1115–1123CrossRef
35.
go back to reference Tanner B (2018) Low rate of capsular contracture in a series of 214 consecutive primary and revision breast augmentations using microtextured implants. JPRAS Open 15:66–73CrossRef Tanner B (2018) Low rate of capsular contracture in a series of 214 consecutive primary and revision breast augmentations using microtextured implants. JPRAS Open 15:66–73CrossRef
36.
go back to reference Quiros MC, Bolanos MC, Fassero JJ (2019) Six-year prospective outcomes of primary breast augmentation with nano surface implants. Aesthet Surg J 39(5):495–508CrossRef Quiros MC, Bolanos MC, Fassero JJ (2019) Six-year prospective outcomes of primary breast augmentation with nano surface implants. Aesthet Surg J 39(5):495–508CrossRef
37.
go back to reference Sforza M, Zaccheddu R, Alleruzzo A, Seno A, Mileto D, Paganelli A, Sulaiman H, Payne M, Maurovich-Horvat L (2018) Preliminary 3-year evaluation of experience with silk surface and velvet surface motiva silicone breast implants: a single-center experience with 5813 consecutive breast augmentation cases. Aesthet Surg J 38(suppl_2):S62–S73CrossRef Sforza M, Zaccheddu R, Alleruzzo A, Seno A, Mileto D, Paganelli A, Sulaiman H, Payne M, Maurovich-Horvat L (2018) Preliminary 3-year evaluation of experience with silk surface and velvet surface motiva silicone breast implants: a single-center experience with 5813 consecutive breast augmentation cases. Aesthet Surg J 38(suppl_2):S62–S73CrossRef
38.
go back to reference Adams WP Jr, Rios JL, Smith SJ (2006) Enhancing patient outcomes in aesthetic and reconstructive breast surgery using triple antibiotic breast irrigation: six-year prospective clinical study. Plast Reconstr Surg 118(7 Suppl):46S–52SCrossRef Adams WP Jr, Rios JL, Smith SJ (2006) Enhancing patient outcomes in aesthetic and reconstructive breast surgery using triple antibiotic breast irrigation: six-year prospective clinical study. Plast Reconstr Surg 118(7 Suppl):46S–52SCrossRef
39.
go back to reference Fine RE, Israel PZ, Walker LC, Corgan KR, Greenwald LV, Berenson JE, Boyd BA, Oliver MK, McClure T, Elberfeld J (2001) A prospective study of the removal rate of imaged breast lesions by an 11-gauge vacuum-assisted biopsy probe system. Am J Surg 182(4):335–340CrossRef Fine RE, Israel PZ, Walker LC, Corgan KR, Greenwald LV, Berenson JE, Boyd BA, Oliver MK, McClure T, Elberfeld J (2001) A prospective study of the removal rate of imaged breast lesions by an 11-gauge vacuum-assisted biopsy probe system. Am J Surg 182(4):335–340CrossRef
40.
go back to reference Baez E, Huber A, Vetter M, Hackeloer BJ (2003) Minimal invasive complete excision of benign breast tumors using a three-dimensional ultrasound-guided mammotome vacuum device. Ultrasound Obstet Gynecol 21(3):267–272CrossRef Baez E, Huber A, Vetter M, Hackeloer BJ (2003) Minimal invasive complete excision of benign breast tumors using a three-dimensional ultrasound-guided mammotome vacuum device. Ultrasound Obstet Gynecol 21(3):267–272CrossRef
Metadata
Title
Simultaneous Augmentation Mammoplasty and Vacuum-Assisted Breast Biopsy for Enhanced Cosmesis and Efficacy
Authors
Il Hwan Byun
Hyun Kook Koo
Soo Jung Kim
Hye-Jin Kim
Sang Woo Lee
Publication date
01-12-2020
Publisher
Springer US
Published in
Aesthetic Plastic Surgery / Issue 6/2020
Print ISSN: 0364-216X
Electronic ISSN: 1432-5241
DOI
https://doi.org/10.1007/s00266-020-01858-0

Other articles of this Issue 6/2020

Aesthetic Plastic Surgery 6/2020 Go to the issue