Skip to main content
Top
Published in: Aesthetic Plastic Surgery 5/2013

01-10-2013 | Letter to the Editor

Interlocking Circumareolar Suture With Undyed Polyamide Thread: A Personal Experience

Authors: Marzia Salgarello, Giuseppe Visconti, Liliana Barone-Adesi

Published in: Aesthetic Plastic Surgery | Issue 5/2013

Login to get access

Abstract

In plastic breast surgery, the interlocking areolar suture has gained wide popularity since its introduction in 2007 by Hammond and colleagues. The interlocking circumareolar suture plays its role in the setting of circumareolar excisions to achieve a durable areola shaping and to prevent scar widening/hypertrophy and areola spreading/distortion. This study retrospectively reviewed 49 breasts that underwent interlocking suture after July 2011 for both aesthetic and reconstructive indications. For the suturing, 3–0 undyed polyamide thread with a straight cutting needle (Dafilon; B. Braun Melsungen AG, Melsungen, Germany) was used. This suture material was preferred to Gore-Tex reported by Hammond and colleagues because it is undyed without any microporous configuration, more wieldy, and less expensive. All 49 breasts showed good results in terms of areola shaping and diameter control as well as good scar quality during a mean follow-up period of 12 months (range 2–18 months) (Fig. 2). No infection, suture extrusion, skin fistula, or granuloma were experienced. The suture was not visible at all, and the patients did not report its palpability. However, at careful examination, the thread resulted slightly palpable.
Level of Evidence V This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.​springer.​com/​00266.
Literature
1.
go back to reference Hammond DC, Khuthaila DK, Kim J (2007) The interlocking Gore-Tex suture for control of areolar diameter and shape. Plast Reconstr Surg 119:804–809PubMedCrossRef Hammond DC, Khuthaila DK, Kim J (2007) The interlocking Gore-Tex suture for control of areolar diameter and shape. Plast Reconstr Surg 119:804–809PubMedCrossRef
2.
go back to reference Righi B, Robotti E (2011) Successfully exploiting two opposing forces: a rational explanation for the “interlocking suture.”. Aesthetic Plast Surg 35:177–183PubMedCrossRef Righi B, Robotti E (2011) Successfully exploiting two opposing forces: a rational explanation for the “interlocking suture.”. Aesthetic Plast Surg 35:177–183PubMedCrossRef
Metadata
Title
Interlocking Circumareolar Suture With Undyed Polyamide Thread: A Personal Experience
Authors
Marzia Salgarello
Giuseppe Visconti
Liliana Barone-Adesi
Publication date
01-10-2013
Publisher
Springer US
Published in
Aesthetic Plastic Surgery / Issue 5/2013
Print ISSN: 0364-216X
Electronic ISSN: 1432-5241
DOI
https://doi.org/10.1007/s00266-013-0186-1

Other articles of this Issue 5/2013

Aesthetic Plastic Surgery 5/2013 Go to the issue