Skip to main content
Top
Published in: Aesthetic Plastic Surgery 5/2007

01-10-2007 | ORIGINAL ARTICLE

Reliability of Handheld Doppler in Planning Local Perforator–Based Flaps for Extremities

Authors: Umar Daraz Khan, J. G. Miller

Published in: Aesthetic Plastic Surgery | Issue 5/2007

Login to get access

Abstract

Background

The perforator-based flap is one of the most common and frequently used options for soft tissue reconstruction on extremities to remedy small to medium-size defects. A Doppler probe has been used to identify these perforators for the designing of the flap base, axis and dimensions. The reliability of the handheld Doppler was assessed for its sensitivity and positive predictive values.

Methods

A prospective study on upper and lower extremities was designed, and 14 volunteers were selected for the study. A handheld Doppler with 8- and 10-MHz probes was used, and the volunteers were subsequently scanned using a color duplex with a linear-array probe of 7 and 10 MHz. A total of 94 perforators were identified on the back of the hand, wrist, and distal 24 cm of the leg.

Results

The 49 perforators marked on 10 legs produced 40 correct, 3 false-positive, and 6 false-negative results. The 33 distal intermetacarpal perforators marked on the back of 11 hands yielded 26 correct, 5 false-positive, and 2 false-negative results. The 12 dorsal carpal arch perforators marked gave 6 correct and 6 false-positive results.

Conclusion

Unidirectional flowmetry using a handheld Doppler is a practical and reliable method for identifying skin perforators. It can be used to plan and design a flap for soft tissue defect reconstruction of extremities in selected cases. The reliability of its use is size dependent, and vessels with a smaller diameter showed unacceptably high false-positive results.
Literature
1.
go back to reference Taylor GI, M Doyle, McCarten G (1990) The Doppler probe for planning flaps: Anatomical study and clinical applications. Br J Plast Surg 43:1–16CrossRefPubMed Taylor GI, M Doyle, McCarten G (1990) The Doppler probe for planning flaps: Anatomical study and clinical applications. Br J Plast Surg 43:1–16CrossRefPubMed
2.
go back to reference Khan UD, McArthur P, Miller JG Extended distally based perforator flap. Autumn meeting of the British Society for Surgery of the Hand and the Swiss Society of Surgery of the Hand at Blackpool, 27–29 October 1999 Khan UD, McArthur P, Miller JG Extended distally based perforator flap. Autumn meeting of the British Society for Surgery of the Hand and the Swiss Society of Surgery of the Hand at Blackpool, 27–29 October 1999
3.
go back to reference Spyriounis PK (2006) The extended approach to the vascular pedicle of the ALT-thigh perforator flap: Anatomical and clinical study. Plast Reconstr Surg 117:997–1001CrossRef Spyriounis PK (2006) The extended approach to the vascular pedicle of the ALT-thigh perforator flap: Anatomical and clinical study. Plast Reconstr Surg 117:997–1001CrossRef
4.
go back to reference Dujon DG, Khan UD, Aslam S (1997) Bipedicle flaps: Simple solutions for difficult problems in the extremities. Br J Plast Surg 50:641–645CrossRefPubMed Dujon DG, Khan UD, Aslam S (1997) Bipedicle flaps: Simple solutions for difficult problems in the extremities. Br J Plast Surg 50:641–645CrossRefPubMed
5.
go back to reference Bisson M, Spyriounis P, Miller J (2004) Perforator-based flaps in distal upper and lower extremity defects. Eur J Plast Surg 25:86–90CrossRef Bisson M, Spyriounis P, Miller J (2004) Perforator-based flaps in distal upper and lower extremity defects. Eur J Plast Surg 25:86–90CrossRef
6.
go back to reference Blondeel PN, Beyens G, Verhaeghe R, Landuyt VK, Tonnard P, Monstrey SJ, Matton G (1998) Doppler flowmetry in the planning of perforator flaps. Br J Plast Surg 51:202–209CrossRefPubMed Blondeel PN, Beyens G, Verhaeghe R, Landuyt VK, Tonnard P, Monstrey SJ, Matton G (1998) Doppler flowmetry in the planning of perforator flaps. Br J Plast Surg 51:202–209CrossRefPubMed
7.
go back to reference Koshima I, Soeda S (1989) Inferior epigastric artery skin flap without rectus abdominis muscle. Br J Plast Surg 42:645–648CrossRefPubMed Koshima I, Soeda S (1989) Inferior epigastric artery skin flap without rectus abdominis muscle. Br J Plast Surg 42:645–648CrossRefPubMed
8.
9.
go back to reference Costa H, Soutar DS (1988) The distally based island posterior interosseous flap. Br J Plast Surg 41:221CrossRefPubMed Costa H, Soutar DS (1988) The distally based island posterior interosseous flap. Br J Plast Surg 41:221CrossRefPubMed
10.
go back to reference Breakwell LM, Khan UD, Miller JG, Spyriounis P Perforator-based flaps. Winter Meeting, British Association of Plastic Surgeons, 2–4 Dec 1998, BOA, Prontaprint, Darlington, UK, p. 31 Breakwell LM, Khan UD, Miller JG, Spyriounis P Perforator-based flaps. Winter Meeting, British Association of Plastic Surgeons, 2–4 Dec 1998, BOA, Prontaprint, Darlington, UK, p. 31
12.
go back to reference Salmon M (1988) Arteries of the skin. Taylor GI, Tempest, MN, Churchill Livingstone, London, p 29–34 Salmon M (1988) Arteries of the skin. Taylor GI, Tempest, MN, Churchill Livingstone, London, p 29–34
13.
14.
go back to reference Komuro Y, Iwata H, Inoue M, Yanai A (2002) Versatility of scanning laser Doppler imaging to detect cutaneous perforators. Ann Plast Surg 48:613–616CrossRefPubMed Komuro Y, Iwata H, Inoue M, Yanai A (2002) Versatility of scanning laser Doppler imaging to detect cutaneous perforators. Ann Plast Surg 48:613–616CrossRefPubMed
15.
go back to reference Khan UD, McArthur P, Miller JG, Shariff S, Ashurst H Reliability of handheld Doppler in planning local skin flaps. Third International Course on Perforator Flaps at Munich, Germany, 12–14 November 1999 Khan UD, McArthur P, Miller JG, Shariff S, Ashurst H Reliability of handheld Doppler in planning local skin flaps. Third International Course on Perforator Flaps at Munich, Germany, 12–14 November 1999
16.
go back to reference Taylor IG, Pan WR (1998) Angiosomes of the leg: Anatomic study and clinical implications. Plast Reconstr Surg 102:599–615CrossRefPubMed Taylor IG, Pan WR (1998) Angiosomes of the leg: Anatomic study and clinical implications. Plast Reconstr Surg 102:599–615CrossRefPubMed
Metadata
Title
Reliability of Handheld Doppler in Planning Local Perforator–Based Flaps for Extremities
Authors
Umar Daraz Khan
J. G. Miller
Publication date
01-10-2007
Publisher
Springer New York
Published in
Aesthetic Plastic Surgery / Issue 5/2007
Print ISSN: 0364-216X
Electronic ISSN: 1432-5241
DOI
https://doi.org/10.1007/s00266-007-0072-9

Other articles of this Issue 5/2007

Aesthetic Plastic Surgery 5/2007 Go to the issue