Skip to main content
Top
Published in: Aesthetic Plastic Surgery 3/2003

01-06-2003

Optimizing Outcomes in Breast Augmentation: Seven Years of Experience with the Subfascial Plane

Authors: João Carlos Sampaio Góes, Alan Landecker

Published in: Aesthetic Plastic Surgery | Issue 3/2003

Login to get access

Abstract

Introduction: Breast augmentation has enjoyed worldwide acceptance in the last few decades. In order to optimize the outcomes of this operation, numerous variables such as incision location, pocket plane, implant design, and materials, and individual tissue characteristics must be carefully considered. Although no combination of choices may be considered superior, satisfactory results depend on adjusting the available options to each patient’s requirements. In this paper, the authors present a seven-year experience with augmentation mammaplasty using the subfascial plane, analyzing important aspects of surgical technique, benefits and trade-offs when compared to other approaches, and the resulting outcomes. Method: A total of 241 primary and secondary breast augmentation procedures were performed over a seven-year period, employing anatomical high-cohesivity gel textured implants (McGhan 410 Style). After choosing the appropriate approach and performing the skin incision, dissection proceeds parallel to the skin (as in skin-sparing mastectomies) for approximately 4 cm. The breast’s parenchyma is then incised in a radial direction (perpendicular to the skin incision) and vertically until the fascial layer is reached. Dissection of the implant’s pocket is then performed in the well-defined subfascial plane. After insertion of the implants, the distance between the areola’s inferior border and the inframammary fold should be approximately equal to 6–7 cm (or X). The distance between the areola’s superior border and the uppermost point of the breast should be approximately equal to 9–10.5 cm (or 1.5X). Another important parameter is the distance between the implants, which should be approximately 2–3 cm. Finally, the distance between the areola’s medial border and the midsternal line should be about 9–10 cm. Postoperative care issues are specified. Results: Pleasing long-term results have been obtained, with maintenance of a natural breast shape, a smooth transition between the soft tissues and implant in the upper pole, and low morbidity. The rate of capsular contracture was extremely low and there were no complaints regarding displacement of the implants with contraction of the pectoralis major muscle. Conclusion: The presented technique offers improved long-term aesthetic results due to the creation of a stronger supporting system for the implant’s superior pole. This tends to keep the implant’s upper third from altering its shape and position over time and combines the potential benefits of the subglandular approach with the improvements that may be achieved by having more tissue available to cover the implant’s upper pole. The trade-offs of the subpectoral approach have been significantly reduced and factors such as morbidity and postoperative recovery are acceptable. The presented technique is extremely versatile and may also be used in patients requiring removal and replacement of breast implants.
Literature
1.
go back to reference Barnett, A 1990Transaxillary subpectoral augmentation in the ptotic breast: Augmentation by disruption of the extended pectoral fascia and parenchymal sweep.Plast Reconstr Surg8676 Barnett, A 1990Transaxillary subpectoral augmentation in the ptotic breast: Augmentation by disruption of the extended pectoral fascia and parenchymal sweep.Plast Reconstr Surg8676
2.
go back to reference Biggs, TM, Yarish, RS 1988Augmentation mammaplasty: Retropectoral versus retromammary implantation.Clin Plast Surg15549PubMed Biggs, TM, Yarish, RS 1988Augmentation mammaplasty: Retropectoral versus retromammary implantation.Clin Plast Surg15549PubMed
3.
go back to reference Dempsey, WC, Latham, WD 1968Subpectoral implants in augmentation mammaplasty: Preliminary report.Plast Reconstr Surg42515 Dempsey, WC, Latham, WD 1968Subpectoral implants in augmentation mammaplasty: Preliminary report.Plast Reconstr Surg42515
4.
go back to reference Graf, RM, et al. 2000Subfascial endoscopic transaxillary augmentation mammaplasty.Aesthetic Plast Surg24216 Graf, RM,  et al. 2000Subfascial endoscopic transaxillary augmentation mammaplasty.Aesthetic Plast Surg24216
5.
go back to reference Gray, H 1989Gray’s anatomy, 37th edition.Longman Group UK LimitedLondon Gray, H 1989Gray’s anatomy, 37th edition.Longman Group UK LimitedLondon
6.
go back to reference Hidalgo, DA 2000Breast augmentation: Choosing the optimal incision, implant, and pocket plane.Plast Reconstr Surg1052202PubMed Hidalgo, DA 2000Breast augmentation: Choosing the optimal incision, implant, and pocket plane.Plast Reconstr Surg1052202PubMed
7.
go back to reference Mahler, D, Ben-Yakar, J, Hauben, DJ 1982The retropectoral route for breast augmentation.Aesthetic Plast Surg6237 Mahler, D, Ben-Yakar, J, Hauben, DJ 1982The retropectoral route for breast augmentation.Aesthetic Plast Surg6237
8.
go back to reference Papillon, J 1976Pros and cons of subpectoral implantation.Clin Plast Surg3321 Papillon, J 1976Pros and cons of subpectoral implantation.Clin Plast Surg3321
9.
go back to reference Puckett, CL, et al. 1987A critical look at capsular contracture in subglandular versus subpectoral mammary augmentation.Aesthetic Plast Surg1123 Puckett, CL,  et al. 1987A critical look at capsular contracture in subglandular versus subpectoral mammary augmentation.Aesthetic Plast Surg1123
10.
go back to reference Regnault, P 1977Partially submuscular breast augmentation.Plast Reconstr Surg5972 Regnault, P 1977Partially submuscular breast augmentation.Plast Reconstr Surg5972
11.
go back to reference Tebbetts, JB 1984Transaxillary subpectoral augmentation mammaplasty: Long-term follow-up and refinements.Plast Reconstr Surg74636 Tebbetts, JB 1984Transaxillary subpectoral augmentation mammaplasty: Long-term follow-up and refinements.Plast Reconstr Surg74636
12.
go back to reference Tebbetts, JB 2001Dual plane breast augmentation: Optimizing implant-soft-tissue relationships in a wide range of breast types.Plast Reconstr Surg1071255 Tebbetts, JB 2001Dual plane breast augmentation: Optimizing implant-soft-tissue relationships in a wide range of breast types.Plast Reconstr Surg1071255
Metadata
Title
Optimizing Outcomes in Breast Augmentation: Seven Years of Experience with the Subfascial Plane
Authors
João Carlos Sampaio Góes
Alan Landecker
Publication date
01-06-2003
Publisher
Springer-Verlag
Published in
Aesthetic Plastic Surgery / Issue 3/2003
Print ISSN: 0364-216X
Electronic ISSN: 1432-5241
DOI
https://doi.org/10.1007/s00266-003-0004-2

Other articles of this Issue 3/2003

Aesthetic Plastic Surgery 3/2003 Go to the issue