01-09-2020 | Hip-TEP | Original Paper

Transitioning the total hip arthroplasty technique from posterior approach in lateral position to direct anterior approach in supine position—risk factors for acetabular malpositioning and the learning curve

Authors: Constant Foissey, Cécile Batailler, Cam Fary, Francesco Luceri, Elvire Servien, Sébastien Lustig

Published in: International Orthopaedics | Issue 9/2020

Login to get access

Abstract

Purpose

Cup positioning is important for optimum hip stability, avoiding component impingement and decreasing both bearing surface wear and revision rate. Transitioning from posterior approach in a lateral position to direct anterior approach (DAA) in a supine presents unique challenges for surgeons. The aim of this study was to examine the learning curve when using standard instrumentation that was not specific to DAA.

Methods

A consecutive retrospective series of 537 total hip arthroplasty by DAA from May 2013 to December 2017. Cup positioning was analysed on radiographs and classified whether inside or outside two safe zones (inclination 30–50° and anteversion 10–30°). The demographic data (age, BMI, gender, neck shaft angle (NSA)), surgeon’s dominant side and experience were assessed as risk factors.

Results

Eighty per cent of cups (n = 426) were in the combined safe zones. Eighty-eight per cent (n = 470) were in appropriate anteversion and 87% (n = 463) abduction. Two factors that were significant were identified: Cups of left hips operated by right-handed surgeons were more anteverted (OR = 4.06) and more vertical (OR = 2.23); females had a higher anteversion of the cup (OR = 2.42). Obesity, age and NSA were not risk factors for cup malposition. There was a spike of cups too horizontal at the beginning of the experience (OR = 3.86), and no learning curve was observed in the other orientations.

Conclusion

With our DAA technique using standard instrumentation, there were no risk factors linked to the patient identified for cup malposition. DAA-specific instrumentation is not required to achieve optimum positioning of the cup. Surgeon has to be aware of an excess of abduction at the beginning of his experience and an excess of anteversion and adduction when performing THA on the opposite side of his dominant hand.
Appendix
Available only for authorised users
Literature
1.
go back to reference Waddell J, Johnson K, Hein W et al (2010) Orthopaedic practice in total hip arthroplasty and total knee arthroplasty: results from the Global Orthopaedic Registry (GLORY). Am J Orthop 39:5–13PubMed Waddell J, Johnson K, Hein W et al (2010) Orthopaedic practice in total hip arthroplasty and total knee arthroplasty: results from the Global Orthopaedic Registry (GLORY). Am J Orthop 39:5–13PubMed
3.
go back to reference Lewinnek G, Lewis J, Tarr R et al (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60:217–220CrossRef Lewinnek G, Lewis J, Tarr R et al (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60:217–220CrossRef
8.
go back to reference Reize P, Geiger EV, Suckel A et al (2008) Influence of surgical experience on accuracy of acetabular cup positioning in total hip arthroplasty. Am J Orthop 37:360–363PubMed Reize P, Geiger EV, Suckel A et al (2008) Influence of surgical experience on accuracy of acetabular cup positioning in total hip arthroplasty. Am J Orthop 37:360–363PubMed
20.
go back to reference Kobayashi H, Homma Y, Baba T et al (2016) Surgeons changing the approach for total hip arthroplasty from posterior to direct anterior with fluoroscopy should consider potential excessive cup anteversion and flexion implantation of the stem in their early experience. Int Orthop 40:1813–1819. https://doi.org/10.1007/s00264-015-3059-1CrossRefPubMed Kobayashi H, Homma Y, Baba T et al (2016) Surgeons changing the approach for total hip arthroplasty from posterior to direct anterior with fluoroscopy should consider potential excessive cup anteversion and flexion implantation of the stem in their early experience. Int Orthop 40:1813–1819. https://​doi.​org/​10.​1007/​s00264-015-3059-1CrossRefPubMed
22.
go back to reference Lustig S (2015) Anterior approach (without specific table) and dual mobility acetabular component. Maitrise Orthop 243:1–5 Lustig S (2015) Anterior approach (without specific table) and dual mobility acetabular component. Maitrise Orthop 243:1–5
26.
go back to reference Crawford DA, Adams JB, Hobbs GR et al (2019) Surgical approach and hip laterality affect accuracy of acetabular component placement in primary total hip arthroplasty. Surg Technol Int 35:377–385PubMed Crawford DA, Adams JB, Hobbs GR et al (2019) Surgical approach and hip laterality affect accuracy of acetabular component placement in primary total hip arthroplasty. Surg Technol Int 35:377–385PubMed
35.
go back to reference Todkar M (2008) Obesity does not necessarily affect the accuracy of acetabular cup implantation in total hip replacement. Acta Orthop Belg 74:206–209PubMed Todkar M (2008) Obesity does not necessarily affect the accuracy of acetabular cup implantation in total hip replacement. Acta Orthop Belg 74:206–209PubMed
43.
go back to reference Honl M, Dierk O, Gauck C et al (2003) Comparison of robotic-assisted and manual implantation of a primary total hip replacement: a prospective study. J Bone Joint Surg Am 85:1470–1478CrossRef Honl M, Dierk O, Gauck C et al (2003) Comparison of robotic-assisted and manual implantation of a primary total hip replacement: a prospective study. J Bone Joint Surg Am 85:1470–1478CrossRef
44.
Metadata
Title
Transitioning the total hip arthroplasty technique from posterior approach in lateral position to direct anterior approach in supine position—risk factors for acetabular malpositioning and the learning curve
Authors
Constant Foissey
Cécile Batailler
Cam Fary
Francesco Luceri
Elvire Servien
Sébastien Lustig
Publication date
01-09-2020
Publisher
Springer Berlin Heidelberg
Keywords
Hip-TEP
Hip-TEP
Published in
International Orthopaedics / Issue 9/2020
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-020-04583-0

Other articles of this Issue 9/2020

International Orthopaedics 9/2020 Go to the issue