Skip to main content
Top
Published in: International Orthopaedics 12/2019

01-12-2019 | Original Paper

Clinical and radiological outcomes in thoracolumbar fractures using the SpineJack device. A prospective study of seventy-four patients with a two point three year mean of follow-up

Authors: Gael Kerschbaumer, Benoit Gaulin, Sébastien Ruatti, Jérôme Tonetti, Mehdi Boudissa

Published in: International Orthopaedics | Issue 12/2019

Login to get access

Abstract

Purpose

The aim of this study was to assess clinical and radiological results of SpineJack on the treatment of vertebral body fractures in a continuous prospective series of patients.

Material and methods

Between May 2012 and April 2015, all patients operated using the SpineJack device were prospectively included in this monocentric study. Demographic data, clinical, and radiological results were recorded. Complications and surgical managements were recorded.

Results

At a mean follow-up of 2.3 years, 74 patients with 77 fractured vertebrae were included. The stand-alone SpineJack group comprised 60 patients with 63 fractured vertebrae (group 1) and the group with additional posterior fixation 14 patients with 14 fractured vertebrae (group 2). The average initial vertebral wedge angle was 13.3 ± 6.1 degrees for group 1 and 15.3 ± 5.7 degrees for group 2 (p = 0.25). Post-operative values were 6.5 ± 4.6 degrees for group 1 and 5.1 ± 3.9 degrees for group 2 (p = 0.31). The differences within the same group were highly significant (p < 0.0005). The loss of reduction at last follow-up was 0.8 ± 1.6 degrees in group 1 and 0.6 ± 2.0 degrees in group 2 (p = 0.77). Subjective results were considered as very good or good for 57 patients (95%) in group 1 and for 11 patients (79%) in group 2, p = 0.07.

Conclusion

The SpineJack seems to be a promising tool in the treatment of traumatic vertebral fractures with a correction in the sagittal plane comparable with what can be found in the literature.
Literature
3.
go back to reference Van Meirhaeghe J, Bastian L, Boonen S, Ranstam J, Tillman JB, Wardlaw D, investigators FREE (2013) A randomized trial of balloon kyphoplasty and nonsurgical management for treating acute vertebral compression fractures: vertebral body kyphosis correction and surgical parameters. Spine (Phila Pa 1976) 38:971–983. https://doi.org/10.1097/BRS.0b013e31828e8e22 CrossRef Van Meirhaeghe J, Bastian L, Boonen S, Ranstam J, Tillman JB, Wardlaw D, investigators FREE (2013) A randomized trial of balloon kyphoplasty and nonsurgical management for treating acute vertebral compression fractures: vertebral body kyphosis correction and surgical parameters. Spine (Phila Pa 1976) 38:971–983. https://​doi.​org/​10.​1097/​BRS.​0b013e31828e8e22​ CrossRef
4.
go back to reference Zairi F, Court C, Tropiano P, Charles YP, Tonetti J, Fuentes S, Litrico S, Deramond H, Beaurain J, Orcel P, Delecrin J, Aebi M, Assaker R, French Society of Spine Surgery (2012) Minimally invasive management of thoraco-lumbar fractures: combined percutaneous fixation and balloon kyphoplasty. Orthop Traumatol Surg Res 98:S105–S111. https://doi.org/10.1016/j.otsr.2012.06.004 CrossRefPubMed Zairi F, Court C, Tropiano P, Charles YP, Tonetti J, Fuentes S, Litrico S, Deramond H, Beaurain J, Orcel P, Delecrin J, Aebi M, Assaker R, French Society of Spine Surgery (2012) Minimally invasive management of thoraco-lumbar fractures: combined percutaneous fixation and balloon kyphoplasty. Orthop Traumatol Surg Res 98:S105–S111. https://​doi.​org/​10.​1016/​j.​otsr.​2012.​06.​004 CrossRefPubMed
6.
go back to reference Ma XL, Xing D, Ma JX, Xu WG, Wang J, Chen Y (2012) Balloon kyphoplasty versus percutaneous vertebroplasty in treating osteoporotic vertebral compression fracture: grading the evidence through a systematic review and meta-analysis. Eur Spine J 21:1844–1859CrossRef Ma XL, Xing D, Ma JX, Xu WG, Wang J, Chen Y (2012) Balloon kyphoplasty versus percutaneous vertebroplasty in treating osteoporotic vertebral compression fracture: grading the evidence through a systematic review and meta-analysis. Eur Spine J 21:1844–1859CrossRef
8.
go back to reference Garnier L, Tonetti J, Bodin A, Vouaillat H, Merloz P, Assaker R, Court C, French Society for Spine Surgery (2012) Kyphoplasty versus vertebroplasty in osteoporotic thoracolumbar spine fractures. Short-term retrospective review of a multicentre cohort of 127 consecutive patients. Orthop Traumatol Surg Res 98:S112–S119. https://doi.org/10.1016/j.otsr.2012.03.018 CrossRefPubMed Garnier L, Tonetti J, Bodin A, Vouaillat H, Merloz P, Assaker R, Court C, French Society for Spine Surgery (2012) Kyphoplasty versus vertebroplasty in osteoporotic thoracolumbar spine fractures. Short-term retrospective review of a multicentre cohort of 127 consecutive patients. Orthop Traumatol Surg Res 98:S112–S119. https://​doi.​org/​10.​1016/​j.​otsr.​2012.​03.​018 CrossRefPubMed
11.
go back to reference Magerl F, Aebi M, Gertzbein SD, Harms J, Nazarian S (1994) A comprehensive classification of thoracic and lumbar injuries. Eur Spine J 3:184–201CrossRef Magerl F, Aebi M, Gertzbein SD, Harms J, Nazarian S (1994) A comprehensive classification of thoracic and lumbar injuries. Eur Spine J 3:184–201CrossRef
19.
go back to reference Noriega DC, Rodrίguez-Monsalve F, Ramajo R, Sánchez-Lite I, Toribio B, Ardura F (2019) Long-term safety and clinical performance of kyphoplasty and SpineJack® procedures in the treatment of osteoporotic vertebral compression fractures: a pilot, monocentric, investigator-initiated study. Osteoporos Int 30:637–645. https://doi.org/10.1007/s00198-018-4773-5 CrossRefPubMed Noriega DC, Rodrίguez-Monsalve F, Ramajo R, Sánchez-Lite I, Toribio B, Ardura F (2019) Long-term safety and clinical performance of kyphoplasty and SpineJack® procedures in the treatment of osteoporotic vertebral compression fractures: a pilot, monocentric, investigator-initiated study. Osteoporos Int 30:637–645. https://​doi.​org/​10.​1007/​s00198-018-4773-5 CrossRefPubMed
22.
go back to reference Yue JJ, Sossan A, Selgrath C, Deutsch LS, Wilkens K, Testaiuti M, Gabriel JP (2002) The treatment of unstable thoracic spine fractures with transpedicular screw instrumentation: a 3-year consecutive series. Spine (Phila Pa 1976) 27:2782–2787CrossRef Yue JJ, Sossan A, Selgrath C, Deutsch LS, Wilkens K, Testaiuti M, Gabriel JP (2002) The treatment of unstable thoracic spine fractures with transpedicular screw instrumentation: a 3-year consecutive series. Spine (Phila Pa 1976) 27:2782–2787CrossRef
24.
go back to reference McCormack T, Karaikovic E, Gaines RW (1994) The load sharing classification of spine fractures. Spine (Phila Pa 1976) 19:1741–1744CrossRef McCormack T, Karaikovic E, Gaines RW (1994) The load sharing classification of spine fractures. Spine (Phila Pa 1976) 19:1741–1744CrossRef
Metadata
Title
Clinical and radiological outcomes in thoracolumbar fractures using the SpineJack device. A prospective study of seventy-four patients with a two point three year mean of follow-up
Authors
Gael Kerschbaumer
Benoit Gaulin
Sébastien Ruatti
Jérôme Tonetti
Mehdi Boudissa
Publication date
01-12-2019
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 12/2019
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-019-04391-1

Other articles of this Issue 12/2019

International Orthopaedics 12/2019 Go to the issue