Purpose

Medial closing-wedge distal femoral osteotomy (MCWDFO) was used to treat valgus knee malalignment combined with lateral compartment disease. The clinical outcome of the osteotomy depends on the accurate correction of valgus malalignment. The aim of this study was to evaluate the accuracy of a MCWDFO assisted by three-dimensional (3D)-printed cutting guides and locking guides.

Patients and methods

Thirty-three consecutive patients (33 knees) were operated on using the same MCWDFO. 3D-printed cutting guides and locking guides were used to locate the osteotomy cut plane and to facilitate closing the wedge in 12 patients (3D-guide group). Another 21 patients (conventional group) underwent MCWDFO following the conventional technique. The desired correction was defined as a weight-bearing line (WBL) coordinate 50% of the width of the tibial plateau from the medial tibial margin. The deviation between the planned and executed WBL coordinate, surgical time and fluoroscopic time were compared.

Results

The mean deviation between the planned and executed WBL coordinate was 4.9% in the 3D-guide group and 7.6% in the conventional group (P = 0.024). Shorter surgical time was found in the 3D-guide group (mean, 77.7 minutes vs. mean, 96.5 minutes; P < 0.001), while the mean number of intra-operative fluoroscopic images was 6.1, compared with 34.7 in the conventional group (P < 0.001).

Conclusion

The use of 3D-printed cutting guides and locking guides can increase the precision of the MCWDFO in patients with lateral compartment disease and valgus deformity, making our surgery more efficiency and occupying less fluoroscopic time.
Literature
1.
go back to reference Julin J, Jämsen E, Puolakka T, Konttinen YT, Moilanen T (2010) Younger age increases the risk of early prosthesis failure following primary total knee replacement for osteoarthritis. A follow-up study of 32,019 total knee replacements in the Finnish Arthroplasty Register. Acta Orthop 81(4):413–419CrossRef Julin J, Jämsen E, Puolakka T, Konttinen YT, Moilanen T (2010) Younger age increases the risk of early prosthesis failure following primary total knee replacement for osteoarthritis. A follow-up study of 32,019 total knee replacements in the Finnish Arthroplasty Register. Acta Orthop 81(4):413–419CrossRef
2.
go back to reference Hui C, Salmon LJ, Kok A, Williams HA, Hockers N, van der Tempel WM et al (2011) Long-termsurvival of high tibial osteotomy for medial compartment osteoarthritis of the knee. Am J Sports Med 39(1):64–70CrossRef Hui C, Salmon LJ, Kok A, Williams HA, Hockers N, van der Tempel WM et al (2011) Long-termsurvival of high tibial osteotomy for medial compartment osteoarthritis of the knee. Am J Sports Med 39(1):64–70CrossRef
3.
go back to reference Coventry MB (1987) Proximal tibial varus osteotomy for osteoarthritis of the lateral compartment of the knee. J Bone Joint Surg Am 69:32–38CrossRef Coventry MB (1987) Proximal tibial varus osteotomy for osteoarthritis of the lateral compartment of the knee. J Bone Joint Surg Am 69:32–38CrossRef
4.
go back to reference Shoji H, Insall J (1973) High tibial osteotomy for osteoarthritis of the knee with valgus deformity. J Bone Joint Surg Am 55:963–973CrossRef Shoji H, Insall J (1973) High tibial osteotomy for osteoarthritis of the knee with valgus deformity. J Bone Joint Surg Am 55:963–973CrossRef
5.
go back to reference Cameron JI, McCauley JC, Kermanshahi AY, Bugbee WD (2015) Lateral opening-wedge distal femoral osteotomy: pain relief, functional improvement, and survivorship at 5 years. Clin Orthop Relat Res 473(6):2009–2015CrossRef Cameron JI, McCauley JC, Kermanshahi AY, Bugbee WD (2015) Lateral opening-wedge distal femoral osteotomy: pain relief, functional improvement, and survivorship at 5 years. Clin Orthop Relat Res 473(6):2009–2015CrossRef
6.
go back to reference Ekeland A, Nerhus TK, Dimmen S, Heir S (2016) Good functional results of distal femoral opening-wedge osteotomy of knees with lateral osteoarthritis. Knee Surg Sports Traumatol Arthrosc 24(5):1702–1709CrossRef Ekeland A, Nerhus TK, Dimmen S, Heir S (2016) Good functional results of distal femoral opening-wedge osteotomy of knees with lateral osteoarthritis. Knee Surg Sports Traumatol Arthrosc 24(5):1702–1709CrossRef
7.
go back to reference Puddu G, Cipolla M, Cerullo G, Franco V, Giannì E (2010) Which osteotomy for a valgus knee? Int Orthop 34(2):239–247CrossRef Puddu G, Cipolla M, Cerullo G, Franco V, Giannì E (2010) Which osteotomy for a valgus knee? Int Orthop 34(2):239–247CrossRef
8.
go back to reference Ribeiro CH, Severino NR, Fucs PM (2013) Preoperative surgical planning versus navigation system in valgus tibial osteotomy: a cross-sectional study. Int Orthop 37(8):1483–1486CrossRef Ribeiro CH, Severino NR, Fucs PM (2013) Preoperative surgical planning versus navigation system in valgus tibial osteotomy: a cross-sectional study. Int Orthop 37(8):1483–1486CrossRef
9.
go back to reference Wagner JD, Baack B, Brown GA, Kelly J (2004) Rapid 3-dimensional prototyping for surgical repair of maxillofacial fractures: a technical note. J Oral Maxillofac Surg 62:898–901CrossRef Wagner JD, Baack B, Brown GA, Kelly J (2004) Rapid 3-dimensional prototyping for surgical repair of maxillofacial fractures: a technical note. J Oral Maxillofac Surg 62:898–901CrossRef
10.
go back to reference Arnal-Burro J, Perez-Mananes R, Gallo-Del-Valle E, Igualada-Blazquez C, Cuervas-Mons M, Vaquero-Martin J (2017) Three dimensional-printed patient-specific cutting guides for femoral varization osteotomy: do it yourself. Knee 24(6):1359–1368CrossRef Arnal-Burro J, Perez-Mananes R, Gallo-Del-Valle E, Igualada-Blazquez C, Cuervas-Mons M, Vaquero-Martin J (2017) Three dimensional-printed patient-specific cutting guides for femoral varization osteotomy: do it yourself. Knee 24(6):1359–1368CrossRef
11.
go back to reference Perez-Mananes R, Burro JA, Manaute JR, Rodriguez FC, Martin JV (2016) 3D surgical printing cutting guides for open-wedge high tibial osteotomy: do it yourself. J Knee Surg 29(8):690–695CrossRef Perez-Mananes R, Burro JA, Manaute JR, Rodriguez FC, Martin JV (2016) 3D surgical printing cutting guides for open-wedge high tibial osteotomy: do it yourself. J Knee Surg 29(8):690–695CrossRef
12.
go back to reference Saragaglia D, Roberts J (2005) Navigated osteotomies around the knee in 170 patients with osteoarthritis secondary to genu varum. Orthopedics 28(10 Suppl):s1269–s1274PubMed Saragaglia D, Roberts J (2005) Navigated osteotomies around the knee in 170 patients with osteoarthritis secondary to genu varum. Orthopedics 28(10 Suppl):s1269–s1274PubMed
13.
go back to reference Puddu G, Cipolla M, Cerullo G, Franco V, Gianni E (2007) Osteotomies: the surgical treatment of the valgus knee. Sports Med Arthrosc Rev 15:15–22CrossRef Puddu G, Cipolla M, Cerullo G, Franco V, Gianni E (2007) Osteotomies: the surgical treatment of the valgus knee. Sports Med Arthrosc Rev 15:15–22CrossRef
14.
go back to reference Stahelin T, Hardegger F, Ward JC (2000) Supracondylar osteotomy of the femur with use of compression–osteosynthesis with a malleable implant. J Bone Joint Surg Am 82:712–722CrossRef Stahelin T, Hardegger F, Ward JC (2000) Supracondylar osteotomy of the femur with use of compression–osteosynthesis with a malleable implant. J Bone Joint Surg Am 82:712–722CrossRef
15.
go back to reference Lützner J, Gross AF, Günther KP, Kirschner S (2009) Reliability of limb alignment measurement for high tibial osteotomy with a navigation system. Eur J Med Res 14(10):447–450CrossRef Lützner J, Gross AF, Günther KP, Kirschner S (2009) Reliability of limb alignment measurement for high tibial osteotomy with a navigation system. Eur J Med Res 14(10):447–450CrossRef
16.
go back to reference Saragaglia D, Chedal-Bornu B (2014) Computer-assisted osteotomy for valgus knees: medium-term results of 29 cases. Orthop Traumatol Surg Res 100(5):527–530CrossRef Saragaglia D, Chedal-Bornu B (2014) Computer-assisted osteotomy for valgus knees: medium-term results of 29 cases. Orthop Traumatol Surg Res 100(5):527–530CrossRef
17.
go back to reference Munier M, Donnez M, Ollivier M, Flecher X, Chabrand P, Argenson JN, Parratte S (2017) Can three-dimensional patient-specific cutting guides be used to achieve optimal correction for high tibial osteotomy? Pilot study. Orthop Traumatol Surg Res 103(2):245–250CrossRef Munier M, Donnez M, Ollivier M, Flecher X, Chabrand P, Argenson JN, Parratte S (2017) Can three-dimensional patient-specific cutting guides be used to achieve optimal correction for high tibial osteotomy? Pilot study. Orthop Traumatol Surg Res 103(2):245–250CrossRef
18.
go back to reference Hoekstra H, Rosseels W, Sermon A, Nijs S (2016) Corrective limb osteotomy using patient specific 3D-printed guides: a technical note. Injury 47(10):2375–2380CrossRef Hoekstra H, Rosseels W, Sermon A, Nijs S (2016) Corrective limb osteotomy using patient specific 3D-printed guides: a technical note. Injury 47(10):2375–2380CrossRef
19.
go back to reference Victor J, Premanathan A (2013) Virtual 3D planning and patient specific surgical guides for osteotomies around the knee: a feasibility and proof-of-concept study. Bone Joint J 95-B(11 Suppl A):153–158CrossRef Victor J, Premanathan A (2013) Virtual 3D planning and patient specific surgical guides for osteotomies around the knee: a feasibility and proof-of-concept study. Bone Joint J 95-B(11 Suppl A):153–158CrossRef
20.
go back to reference Çalbıyık M (2017) Clinical outcome of total knee arthroplasty performed using patient-specific cutting guides. Med Sci Monit 23:6168–6173CrossRef Çalbıyık M (2017) Clinical outcome of total knee arthroplasty performed using patient-specific cutting guides. Med Sci Monit 23:6168–6173CrossRef
21.
go back to reference Radtke K, Becher C, Noll Y, Ostermeier S (2010) Effect of limb rotation on radiographic alignment in total knee arthroplasties. Arch Orthop Trauma Surg 130:451–457CrossRef Radtke K, Becher C, Noll Y, Ostermeier S (2010) Effect of limb rotation on radiographic alignment in total knee arthroplasties. Arch Orthop Trauma Surg 130:451–457CrossRef
22.
go back to reference Swanson KE, Stocks GW, Warren PD, Hazel MR, Janssen HF (2000) Does axial limb rotation affect the alignment measurements in deformed limbs? Clin Orthop Relat Res:246–252 Swanson KE, Stocks GW, Warren PD, Hazel MR, Janssen HF (2000) Does axial limb rotation affect the alignment measurements in deformed limbs? Clin Orthop Relat Res:246–252
23.
go back to reference Lee YS, Park SJ, Shin VI, Lee JH, Kim YH, Song EK (2010) Achievement of targeted posterior slope in the medial opening wedge high tibial osteotomy: a mathematical approach. Ann Biomed Eng 38:583–593CrossRef Lee YS, Park SJ, Shin VI, Lee JH, Kim YH, Song EK (2010) Achievement of targeted posterior slope in the medial opening wedge high tibial osteotomy: a mathematical approach. Ann Biomed Eng 38:583–593CrossRef
24.
go back to reference Subburaj K, Ravi B, Agarwal M (2010) Computer-aided methods for assessing lower limb deformities in orthopaedic surgery planning. Comput Med Imaging Graph 34:277–288CrossRef Subburaj K, Ravi B, Agarwal M (2010) Computer-aided methods for assessing lower limb deformities in orthopaedic surgery planning. Comput Med Imaging Graph 34:277–288CrossRef
Metadata
Title
Three dimensional patient-specific printed cutting guides for closing-wedge distal femoral osteotomy
Publication date
01-03-2019
Published in
International Orthopaedics / Issue 3/2019
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-018-4043-3

Other articles of this Issue 3/2019

International Orthopaedics 3/2019 Go to the issue