Skip to main content
Top
Published in: International Orthopaedics 2/2019

01-02-2019 | Original Paper

Conventional plate fixation method versus pre-operative virtual simulation and three-dimensional printing-assisted contoured plate fixation method in the treatment of anterior pelvic ring fracture

Authors: Chun-Chi Hung, Yuan-Ta Li, Yu-Ching Chou, Jia-En Chen, Chia-Chun Wu, Hsain-Chung Shen, Tsu-Te Yeh

Published in: International Orthopaedics | Issue 2/2019

Login to get access

Abstract

Purpose

Treating pelvic fractures remains a challenging task for orthopaedic surgeons. We aimed to evaluate the feasibility, accuracy, and effectiveness of three-dimensional (3D) printing technology and computer-assisted virtual surgery for pre-operative planning in anterior ring fractures of the pelvis. We hypothesized that using 3D printing models would reduce operation time and significantly improve the surgical outcomes of pelvic fracture repair.

Methods

We retrospectively reviewed the records of 30 patients with pelvic fractures treated by anterior pelvic fixation with locking plates (14 patients, conventional locking plate fixation; 16 patients, pre-operative virtual simulation with 3D, printing-assisted, pre-contoured, locking plate fixation). We compared operative time, instrumentation time, blood loss, and post-surgical residual displacements, as evaluated on X-ray films, among groups. Statistical analyses evaluated significant differences between the groups for each of these variables.

Results

The patients treated with the virtual simulation and 3D printing-assisted technique had significantly shorter internal fixation times, shorter surgery duration, and less blood loss (− 57 minutes, − 70 minutes, and − 274 ml, respectively; P < 0.05) than patients in the conventional surgery group. However, the post-operative radiological result was similar between groups (P > 0.05). The complication rate was less in the 3D printing group (1/16 patients) than in the conventional surgery group (3/14 patients).

Conclusion

The 3D simulation and printing technique is an effective and reliable method for treating anterior pelvic ring fractures. With precise pre-operative planning and accurate execution of the procedures, this time-saving approach can provide a more personalized treatment plan, allowing for a safer orthopaedic surgery.
Literature
2.
go back to reference Matta JM (1996) Indications for anterior fixation of pelvic fractures. Clin Orthop Relat Res 329:88–96CrossRef Matta JM (1996) Indications for anterior fixation of pelvic fractures. Clin Orthop Relat Res 329:88–96CrossRef
3.
go back to reference Tile M (2005) Fractures of the acetabulum. In: Schatzker J, Tile M (eds) The rationale of operative fracture care, 3rd edn. Springer, New York, pp 291–340CrossRef Tile M (2005) Fractures of the acetabulum. In: Schatzker J, Tile M (eds) The rationale of operative fracture care, 3rd edn. Springer, New York, pp 291–340CrossRef
4.
go back to reference Fuller SM, Butz DR, Vevang CB, Makhlouf MV (2014) Application of 3-dimensional printing in hand surgery for production of a novel bone reduction clamp. J Hand Surg 39(9):1840–1845CrossRef Fuller SM, Butz DR, Vevang CB, Makhlouf MV (2014) Application of 3-dimensional printing in hand surgery for production of a novel bone reduction clamp. J Hand Surg 39(9):1840–1845CrossRef
5.
go back to reference Rankin TM, Giovinco NA, Cucher DJ, Watts G, Hurwitz B, Armstrong DG (2014) 3D printing surgical instruments: are we there yet? J Surg Res 189:193–197CrossRefPubMedPubMedCentral Rankin TM, Giovinco NA, Cucher DJ, Watts G, Hurwitz B, Armstrong DG (2014) 3D printing surgical instruments: are we there yet? J Surg Res 189:193–197CrossRefPubMedPubMedCentral
6.
go back to reference Wu XB, Wang JQ, Zhao CP, Sun X, Shi Y, Zhang ZA, Li YN, Wang MY (2015) Printed three-dimensional anatomic templates for virtual preoperative planning before reconstruction of old pelvic injuries: initial results. Chin Med J 128:477–482CrossRefPubMedPubMedCentral Wu XB, Wang JQ, Zhao CP, Sun X, Shi Y, Zhang ZA, Li YN, Wang MY (2015) Printed three-dimensional anatomic templates for virtual preoperative planning before reconstruction of old pelvic injuries: initial results. Chin Med J 128:477–482CrossRefPubMedPubMedCentral
7.
go back to reference Rhee YG, Cho NS, Cha SW, Moon SC, Hwang SP (2014) Indirect reduction technique in proximal humeral fractures stabilized by locking plates. Clin Should Elbow 17:2–9CrossRef Rhee YG, Cho NS, Cha SW, Moon SC, Hwang SP (2014) Indirect reduction technique in proximal humeral fractures stabilized by locking plates. Clin Should Elbow 17:2–9CrossRef
8.
go back to reference Tam MD, Laycock SD, Bell D, Chojnowski A (2012) 3-D printout of a DICOM file to aid surgical planning in a 6-year-old patient with a large scapular osteochondroma complicating congenital diaphyseal aclasia. J Radiol Case Rep 6:31–37PubMedPubMedCentral Tam MD, Laycock SD, Bell D, Chojnowski A (2012) 3-D printout of a DICOM file to aid surgical planning in a 6-year-old patient with a large scapular osteochondroma complicating congenital diaphyseal aclasia. J Radiol Case Rep 6:31–37PubMedPubMedCentral
9.
go back to reference Munjal S, Leopold SS, Kornreich D, Shott S, Finn HA (2000) CT-generated 3-dimensional models for complex acetabular reconstruction. J Arthroplast 15:644–653CrossRef Munjal S, Leopold SS, Kornreich D, Shott S, Finn HA (2000) CT-generated 3-dimensional models for complex acetabular reconstruction. J Arthroplast 15:644–653CrossRef
11.
go back to reference Schwartz A, Money K, Spangehl M, Hattrup S, Claridge RJ, Beauchamp C (2015) Office-based rapid prototyping in orthopedic surgery: a novel planning technique and review of the literature. Am J Orthop (Belle Mead NJ) 44:19–25 Schwartz A, Money K, Spangehl M, Hattrup S, Claridge RJ, Beauchamp C (2015) Office-based rapid prototyping in orthopedic surgery: a novel planning technique and review of the literature. Am J Orthop (Belle Mead NJ) 44:19–25
12.
go back to reference Cimerman M, Kristan A (2007) Preoperative planning in pelvic and acetabular surgery: the value of advanced computerised planning modules. Injury 38:442–449CrossRefPubMed Cimerman M, Kristan A (2007) Preoperative planning in pelvic and acetabular surgery: the value of advanced computerised planning modules. Injury 38:442–449CrossRefPubMed
13.
go back to reference Shen F, Chen B, Guo Q, Qi Y, Shen Y (2013) Augmented reality patient specific reconstruction plate design for pelvic and acetabular fracture surgery. Int J Comput Assist Radiol Surg 8:169–179CrossRefPubMed Shen F, Chen B, Guo Q, Qi Y, Shen Y (2013) Augmented reality patient specific reconstruction plate design for pelvic and acetabular fracture surgery. Int J Comput Assist Radiol Surg 8:169–179CrossRefPubMed
14.
go back to reference Rose AS, Webster CE, Harrysson OL, Formeister EJ, Rawal RB, Iseli CE (2015) Preoperative simulation of pediatric mastoid surgery with 3D-printed temporal bone models. Int J Pediatr Otorhinolaryngol 79:740–744CrossRef Rose AS, Webster CE, Harrysson OL, Formeister EJ, Rawal RB, Iseli CE (2015) Preoperative simulation of pediatric mastoid surgery with 3D-printed temporal bone models. Int J Pediatr Otorhinolaryngol 79:740–744CrossRef
15.
go back to reference Tile M, Helfet D, Kellam J (2003) Fractures of pelvis and acetabulum. Lippincott Williams and Wilkins, Philadelphia Tile M, Helfet D, Kellam J (2003) Fractures of pelvis and acetabulum. Lippincott Williams and Wilkins, Philadelphia
16.
go back to reference Bagaria V, Deshpande S, Rasalkar DD, Kuthe A, Paunipagar BK (2011) Use of rapid prototyping and three-dimensional reconstruction modeling in the management of complex fractures. Eur J Radiol 80:814–820CrossRefPubMed Bagaria V, Deshpande S, Rasalkar DD, Kuthe A, Paunipagar BK (2011) Use of rapid prototyping and three-dimensional reconstruction modeling in the management of complex fractures. Eur J Radiol 80:814–820CrossRefPubMed
17.
go back to reference O’Shea K, Quinlan JF, Waheed K, Brady OH (2006) The usefulness of computed tomography following open reduction and internal fixation of acetabular fractures. J Orthop Surg (Hong Kong) 14:127–132CrossRef O’Shea K, Quinlan JF, Waheed K, Brady OH (2006) The usefulness of computed tomography following open reduction and internal fixation of acetabular fractures. J Orthop Surg (Hong Kong) 14:127–132CrossRef
18.
go back to reference Lindahl J, Hirvensalo E, Böstman O, Santavirta S (1999) Failure of reduction with an external fixator in the management of injuries of the pelvic ring. Long-term evaluation of 110 patients. J Bone Joint Surg Br 81:955–962CrossRefPubMed Lindahl J, Hirvensalo E, Böstman O, Santavirta S (1999) Failure of reduction with an external fixator in the management of injuries of the pelvic ring. Long-term evaluation of 110 patients. J Bone Joint Surg Br 81:955–962CrossRefPubMed
Metadata
Title
Conventional plate fixation method versus pre-operative virtual simulation and three-dimensional printing-assisted contoured plate fixation method in the treatment of anterior pelvic ring fracture
Authors
Chun-Chi Hung
Yuan-Ta Li
Yu-Ching Chou
Jia-En Chen
Chia-Chun Wu
Hsain-Chung Shen
Tsu-Te Yeh
Publication date
01-02-2019
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 2/2019
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-018-3963-2

Other articles of this Issue 2/2019

International Orthopaedics 2/2019 Go to the issue