Skip to main content
Top
Published in: International Orthopaedics 3/2017

01-03-2017 | Original Paper

In total hip arthroplasty via the direct anterior approach, a dual-mobility cup prevents dislocation as effectively in hip fracture as in osteoarthritis

Authors: Yasuhiro Homma, Tomonori Baba, Yu Ozaki, Taiji Watari, Hideo Kobayashi, Hironori Ochi, Mikio Matsumoto, Kazuo Kaneko

Published in: International Orthopaedics | Issue 3/2017

Login to get access

Abstract

Purpose

The main purpose of this study was to compare the outcome of total hip arthroplasty (THA) via the direct anterior approach (DAA) using a dual-mobility cup (DMC) in patients with femoral neck fracture to those in patients undergoing elective THA for osteoarthritis.

Patients and methods

We retrospectively investigated 40 hips with femoral neck fracture (group A), and 81 hips with osteoarthritis (group B). THA via the DAA using the DMC was performed in both groups. A primary/secondary outcome variable were the presence of dislocation/operative time, intra- and/or peri-operative complication, and mortality.

Results

Dislocation did not occur in either group. The complication rate was slightly higher in group A than in group B, but not statistically significant.

Conclusion

THA with the DMC using the DAA was as effective for femoral neck facture as it was for elective THA in patients with osteoarthritis.
Literature
1.
go back to reference Adam P, Farizon F, Fessy MH (2005) Dual articulation retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants. Rev Chir Orthop Reparatrice Appar Mot 91:627–636CrossRefPubMed Adam P, Farizon F, Fessy MH (2005) Dual articulation retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants. Rev Chir Orthop Reparatrice Appar Mot 91:627–636CrossRefPubMed
2.
go back to reference Farizon F, De Lavison R, Azoulai JJ, Bousquet G (1998) Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up study. Int Orthop 22:219–224CrossRefPubMedPubMedCentral Farizon F, De Lavison R, Azoulai JJ, Bousquet G (1998) Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up study. Int Orthop 22:219–224CrossRefPubMedPubMedCentral
3.
go back to reference Leiber-Wackenheim F, Brunschweiler B, Ehlinger M, Gabrion A, Mertl P (2011) Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years’ follow-up. Orthop Traumatol Surg Res 97(1):8–13CrossRefPubMed Leiber-Wackenheim F, Brunschweiler B, Ehlinger M, Gabrion A, Mertl P (2011) Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years’ follow-up. Orthop Traumatol Surg Res 97(1):8–13CrossRefPubMed
4.
go back to reference Langlais FL, Ropars M, Gaucher F, Musset T, Chaix O (2008) Dual mobility cemented cups have low dislocation rates in THA revisions. Clin Orthop 466(2):389–395CrossRefPubMedPubMedCentral Langlais FL, Ropars M, Gaucher F, Musset T, Chaix O (2008) Dual mobility cemented cups have low dislocation rates in THA revisions. Clin Orthop 466(2):389–395CrossRefPubMedPubMedCentral
5.
go back to reference Guyen O, Pibarot V, Vaz G, Chevillotte C, Carret JP, Bejui-Hugues J (2007) Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation. J Arthroplasty 22:849–858CrossRefPubMed Guyen O, Pibarot V, Vaz G, Chevillotte C, Carret JP, Bejui-Hugues J (2007) Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation. J Arthroplasty 22:849–858CrossRefPubMed
6.
go back to reference Bouchet R, Mercier N, Saragaglia D (2011) Posterior approach and dislocation rate: a 213 total hip replacements case–control study comparing the dual mobility cup with a conventional 28-mm metal head/polyethylene prosthesis. Orthop Traumatol Surg Res 97(1):2–7CrossRefPubMed Bouchet R, Mercier N, Saragaglia D (2011) Posterior approach and dislocation rate: a 213 total hip replacements case–control study comparing the dual mobility cup with a conventional 28-mm metal head/polyethylene prosthesis. Orthop Traumatol Surg Res 97(1):2–7CrossRefPubMed
7.
go back to reference Bauchu P, Bonnard O, Cypres A, Fiquet A, Girardin P, Noyer D (2008) The dual-mobility POLARCUP: first results from a multicenter study. Orthopedics 31(12 Suppl 2):1663–1772 Bauchu P, Bonnard O, Cypres A, Fiquet A, Girardin P, Noyer D (2008) The dual-mobility POLARCUP: first results from a multicenter study. Orthopedics 31(12 Suppl 2):1663–1772
8.
go back to reference Caton JH, Prudhon JL, Ferreira A, Aslanian T, Verdier R (2014) A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk. Int Orthop 38(6):1125–1129CrossRefPubMedPubMedCentral Caton JH, Prudhon JL, Ferreira A, Aslanian T, Verdier R (2014) A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk. Int Orthop 38(6):1125–1129CrossRefPubMedPubMedCentral
9.
go back to reference Baker RP, Squires B, Gargan MF, Bannister GC (2006) Total hip arthroplasty and hemiarthroplasty in mobile, independent patients with a displaced intracapsular fracture of the femoral neck: a randomized controlled trial. J Bone Joint Surg Am 88:2583–2589PubMed Baker RP, Squires B, Gargan MF, Bannister GC (2006) Total hip arthroplasty and hemiarthroplasty in mobile, independent patients with a displaced intracapsular fracture of the femoral neck: a randomized controlled trial. J Bone Joint Surg Am 88:2583–2589PubMed
10.
go back to reference Keating JF, Grant A, Masson M, Scott NW, Forbes JF (2006) Randomized comparison of reduction and fixation, bipolar hemiarthroplasty, and total hip arthroplasty. Treatment of displaced intracapsular hip fractures in healthy older patients. J Bone Joint Surg Am 88(2):249–260. doi:10.2106/jbjs.e.00215 PubMed Keating JF, Grant A, Masson M, Scott NW, Forbes JF (2006) Randomized comparison of reduction and fixation, bipolar hemiarthroplasty, and total hip arthroplasty. Treatment of displaced intracapsular hip fractures in healthy older patients. J Bone Joint Surg Am 88(2):249–260. doi:10.​2106/​jbjs.​e.​00215 PubMed
11.
go back to reference Skinner P, Riley D, Ellery J, Beaumont A, Coumine R, Shafighian B (1989) Displaced subcapital fractures of the femur: a prospective randomized comparison of internal fixation, hemiarthroplasty and total hip replacement. Injury 20(5):291–293CrossRefPubMed Skinner P, Riley D, Ellery J, Beaumont A, Coumine R, Shafighian B (1989) Displaced subcapital fractures of the femur: a prospective randomized comparison of internal fixation, hemiarthroplasty and total hip replacement. Injury 20(5):291–293CrossRefPubMed
12.
go back to reference Macaulay W, Nellans KW, Iorio R, Garvin KL, Healy WL, Rosenwasser MP et al (2008) Total hip arthroplasty is less painful at 12 months compared with hemiarthroplasty in treatment of displaced femoral neck fracture. HSS J 4(1):48–54. doi:10.1007/s11420-007-9061-4 CrossRefPubMed Macaulay W, Nellans KW, Iorio R, Garvin KL, Healy WL, Rosenwasser MP et al (2008) Total hip arthroplasty is less painful at 12 months compared with hemiarthroplasty in treatment of displaced femoral neck fracture. HSS J 4(1):48–54. doi:10.​1007/​s11420-007-9061-4 CrossRefPubMed
13.
go back to reference Lim JW, Ng GS, Jenkins RC, Ridley D, Jariwala AC, Sripada S (2016) Total hip replacement for neck of femur fracture: comparing outcomes with matched elective cohort. Injury 47(10):2144-2148. doi:10.1016/j.injury.2016.07.019 Lim JW, Ng GS, Jenkins RC, Ridley D, Jariwala AC, Sripada S (2016) Total hip replacement for neck of femur fracture: comparing outcomes with matched elective cohort. Injury 47(10):2144-2148. doi:10.1016/j.injury.2016.07.019
14.
go back to reference Anakwe RE, Middleton SD, Jenkins PJ, Butler AP, Aitken SA, Keating JF et al (2012) Total hip replacement in patients with hip fracture: a matched cohort study. J Trauma Acute Care Surg 73(3):738–742CrossRefPubMed Anakwe RE, Middleton SD, Jenkins PJ, Butler AP, Aitken SA, Keating JF et al (2012) Total hip replacement in patients with hip fracture: a matched cohort study. J Trauma Acute Care Surg 73(3):738–742CrossRefPubMed
15.
go back to reference Tarasevicius S, Busevicius M, Robertsson O, Wingstrand H (2010) Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture. BMC Musculoskelet Disord 11(1):175CrossRefPubMedPubMedCentral Tarasevicius S, Busevicius M, Robertsson O, Wingstrand H (2010) Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture. BMC Musculoskelet Disord 11(1):175CrossRefPubMedPubMedCentral
16.
go back to reference Nich C, Vandenbussche E, Augereau B, Sadaka J (2016) Do dual-mobility cups reduce the risk of dislocation in total hip arthroplasty for fractured neck of femur in patients aged older than 75 years? J Arthroplasty 31(6):1256–1260CrossRefPubMed Nich C, Vandenbussche E, Augereau B, Sadaka J (2016) Do dual-mobility cups reduce the risk of dislocation in total hip arthroplasty for fractured neck of femur in patients aged older than 75 years? J Arthroplasty 31(6):1256–1260CrossRefPubMed
17.
go back to reference Bensen AS, Jakobsen T, Krarup N (2014) Dual mobility cup reduces dislocation and re-operation when used to treat displaced femoral neck fractures. Int Orthop 38(6):1241–1245CrossRefPubMedPubMedCentral Bensen AS, Jakobsen T, Krarup N (2014) Dual mobility cup reduces dislocation and re-operation when used to treat displaced femoral neck fractures. Int Orthop 38(6):1241–1245CrossRefPubMedPubMedCentral
18.
go back to reference Steffann F, Prudhon JL, Puch JM, Ferreira A, Descamps L, Verdier R, Caton J (2015) Trans trochanteric approach with coronal osteotomy of the great trochanter: a new technique for extra-capsular trochanteric fracture patients treated by total hip arthroplasty (THA) in elderly. SICOT J 5:1–7. doi:10.1051/sicotj/2015015 Steffann F, Prudhon JL, Puch JM, Ferreira A, Descamps L, Verdier R, Caton J (2015) Trans trochanteric approach with coronal osteotomy of the great trochanter: a new technique for extra-capsular trochanteric fracture patients treated by total hip arthroplasty (THA) in elderly. SICOT J 5:1–7. doi:10.​1051/​sicotj/​2015015
19.
go back to reference Homma Y, Baba T, Kobayashi H, Desroches A, Ozaki Y, Ochi H, Matsumoto M, Yuasa T, Kaneko K (2016) Safety in early experience with a direct anterior approach using fluoroscopic guidance with manual leg control for primary total hip arthroplasty: a consecutive one hundred and twenty case series. Int Orthop Mar. doi:10.1007/s00264-016-3159-6 Homma Y, Baba T, Kobayashi H, Desroches A, Ozaki Y, Ochi H, Matsumoto M, Yuasa T, Kaneko K (2016) Safety in early experience with a direct anterior approach using fluoroscopic guidance with manual leg control for primary total hip arthroplasty: a consecutive one hundred and twenty case series. Int Orthop Mar. doi:10.​1007/​s00264-016-3159-6
20.
go back to reference Burgers PT, Van Geene AR, Van den Bekerom MP, Van Lieshout EM, Blom B, Aleem IS, Bhandari M, Poolman RW (2012) Total hip arthroplasty versus hemiarthroplasty for displaced femoral neck fractures in the healthy elderly: a meta-analysis and systematic review of randomized trials. Int Orthop 36(8):1549–1560CrossRefPubMedPubMedCentral Burgers PT, Van Geene AR, Van den Bekerom MP, Van Lieshout EM, Blom B, Aleem IS, Bhandari M, Poolman RW (2012) Total hip arthroplasty versus hemiarthroplasty for displaced femoral neck fractures in the healthy elderly: a meta-analysis and systematic review of randomized trials. Int Orthop 36(8):1549–1560CrossRefPubMedPubMedCentral
21.
go back to reference Tarasevicius S, Robertsson O, Dobozinskas P, Wingstrand H (2013) A comparison of outcomes and dislocation rates using dual articulation cups and THA for intracapsular femoral neck fractures. Hip Int 23(1):22–26CrossRefPubMed Tarasevicius S, Robertsson O, Dobozinskas P, Wingstrand H (2013) A comparison of outcomes and dislocation rates using dual articulation cups and THA for intracapsular femoral neck fractures. Hip Int 23(1):22–26CrossRefPubMed
22.
go back to reference Simon SR, Alaranta H, An KN et al (2000) Kinesiology. In: Buck-Walter JA, Einhorn TA, Simon SR, American Academy of Orthopaedic Surgeons (eds) Orthopaedic basic science: Biology and biomechanics of the musculoskeletal system 2nd edn. American Academy of Orthopaedic Surgeons, Rosemont, pp 782–788 Simon SR, Alaranta H, An KN et al (2000) Kinesiology. In: Buck-Walter JA, Einhorn TA, Simon SR, American Academy of Orthopaedic Surgeons (eds) Orthopaedic basic science: Biology and biomechanics of the musculoskeletal system 2nd edn. American Academy of Orthopaedic Surgeons, Rosemont, pp 782–788
23.
go back to reference Homma Y, Baba T, Kobayashi H, Murphy CG, Kaneko K (2015) The importance of the soft tissue stabilizers of the hip: three cases of rapid onset osteoarthritis following hip arthroscopy. J Orthop Sci Dec. doi:10.1016/j.jos.2015.11.003 Homma Y, Baba T, Kobayashi H, Murphy CG, Kaneko K (2015) The importance of the soft tissue stabilizers of the hip: three cases of rapid onset osteoarthritis following hip arthroscopy. J Orthop Sci Dec. doi:10.​1016/​j.​jos.​2015.​11.​003
24.
go back to reference Thürig G, Schmitt JW, Slankamenac K, Werner CM (2016) Safety of total hip arthroplasty for femoral neck fractures using the direct anterior approach: a retrospective observational study in 86 elderly patients. Patient Saf Surg 10(1):1CrossRef Thürig G, Schmitt JW, Slankamenac K, Werner CM (2016) Safety of total hip arthroplasty for femoral neck fractures using the direct anterior approach: a retrospective observational study in 86 elderly patients. Patient Saf Surg 10(1):1CrossRef
25.
go back to reference Adam P, Philippe R, Ehlinger M, Roche O, Bonnomet F, Molé D, Fessy MH, French Society of Orthopaedic Surgery and Traumatology (SoFCOT) (2012) Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation. Orthop Traumatol Surg Res 98(3):296–300CrossRefPubMed Adam P, Philippe R, Ehlinger M, Roche O, Bonnomet F, Molé D, Fessy MH, French Society of Orthopaedic Surgery and Traumatology (SoFCOT) (2012) Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation. Orthop Traumatol Surg Res 98(3):296–300CrossRefPubMed
26.
go back to reference Homma Y, Baba T, Kobayashi H, Desroches A, Ochi H, Ozaki Y, Matsumoto M, Yuasa T, Kaneko K (2016) Benefit and risk in short term after total hip arthroplasty by direct anterior approach combined with dual mobility cup. Eur J Orthop Surg Traumatol 26(6):619–624CrossRefPubMed Homma Y, Baba T, Kobayashi H, Desroches A, Ochi H, Ozaki Y, Matsumoto M, Yuasa T, Kaneko K (2016) Benefit and risk in short term after total hip arthroplasty by direct anterior approach combined with dual mobility cup. Eur J Orthop Surg Traumatol 26(6):619–624CrossRefPubMed
27.
go back to reference Pala E, Trono M, Bitonti A, Lucidi G (2016) Hip hemiarthroplasty for femur neck fractures: minimally invasive direct anterior approach versus postero-lateral approach. Eur J Orthop Surg Traumatol 26(4):423–427CrossRefPubMed Pala E, Trono M, Bitonti A, Lucidi G (2016) Hip hemiarthroplasty for femur neck fractures: minimally invasive direct anterior approach versus postero-lateral approach. Eur J Orthop Surg Traumatol 26(4):423–427CrossRefPubMed
Metadata
Title
In total hip arthroplasty via the direct anterior approach, a dual-mobility cup prevents dislocation as effectively in hip fracture as in osteoarthritis
Authors
Yasuhiro Homma
Tomonori Baba
Yu Ozaki
Taiji Watari
Hideo Kobayashi
Hironori Ochi
Mikio Matsumoto
Kazuo Kaneko
Publication date
01-03-2017
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 3/2017
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-016-3332-y

Other articles of this Issue 3/2017

International Orthopaedics 3/2017 Go to the issue