Skip to main content
Top
Published in: International Orthopaedics 7/2011

01-07-2011 | Original Paper

Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws

Authors: Guido Garavaglia, Anne Lübbeke, Christophe Barea, Constantinos Roussos, Robin Peter, Pierre Hoffmeyer

Published in: International Orthopaedics | Issue 7/2011

Login to get access

Abstract

Total hip arthroplasty (THA) with well designed cementless acetabular implants has shown excellent results. The purpose of this study was to assess our clinical and radiological outcomes using an uncemented cup. We conducted a prospective cohort study including all consecutive primary THAs performed with the Morscher press-fit cup, an uncemented non-modular acetabular component, between March 1996 and December 1998. Patients were evaluated at ten years with clinical and radiological follow-up, patient satisfaction and questionnaire assessment using the Harris hip score (HHS), Merle d’Aubigné and Postel score, the UCLA score, the 12-item short-form health survey (SF-12) and a visual analog scale. Five hundred sixty-one THAs were performed in 518 patients. At 120 months (± 7.3 months), 303 patients with 335 THAs were still available for follow-up. None of the patients had required cup revision for aseptic loosening. At ten years, the cup survivorship was 98.8% (95% CI 97.4–99.5) with cup revision for any cause as an endpoint. No radiolucencies were seen around the cups, but osteolytic defects involved 21 stems (8.3%). Mean total linear polyethylene wear was 0.9 mm. The Morscher acetabular replacement cup provides excellent results at ten years. There were no revisions for aseptic loosening of the cup, and no osteolytic defects were found around the cup. Patient satisfaction was high and the clinical results were very good.
Literature
1.
go back to reference Latimer HA, Lachiewicz PF (1996) Porous-coated acetabular components with screw fixation. Five to ten-year results. J Bone Joint Surg Am 78(7):975–981PubMed Latimer HA, Lachiewicz PF (1996) Porous-coated acetabular components with screw fixation. Five to ten-year results. J Bone Joint Surg Am 78(7):975–981PubMed
2.
go back to reference Smith SE, Harris WH (1997) Total hip arthroplasty performed with insertion of the femoral component with cement and the acetabular component without cement. Ten to thirteen-year results. J Bone Joint Surg Am 79(12):1827–1833PubMed Smith SE, Harris WH (1997) Total hip arthroplasty performed with insertion of the femoral component with cement and the acetabular component without cement. Ten to thirteen-year results. J Bone Joint Surg Am 79(12):1827–1833PubMed
3.
go back to reference Barrack RL, Mulroy RD Jr, Harris WH (1992) Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review. J Bone Joint Surg Br 74:385–389PubMed Barrack RL, Mulroy RD Jr, Harris WH (1992) Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review. J Bone Joint Surg Br 74:385–389PubMed
4.
go back to reference Sullivan PM, MacKenzie JR, Callaghan JJ, Johnston RC (1994) Total hip arthroplasty with cement in patients who are less than fifty years old. A sixteen to twenty-two-year follow-up study. J Bone Joint Surg Am 76:863–869PubMed Sullivan PM, MacKenzie JR, Callaghan JJ, Johnston RC (1994) Total hip arthroplasty with cement in patients who are less than fifty years old. A sixteen to twenty-two-year follow-up study. J Bone Joint Surg Am 76:863–869PubMed
5.
go back to reference Schulte KR, Callaghan JJ, Kelley SS, Johnston RC (1993) The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon. J Bone Joint Surg Am 75:961–975PubMed Schulte KR, Callaghan JJ, Kelley SS, Johnston RC (1993) The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon. J Bone Joint Surg Am 75:961–975PubMed
6.
go back to reference Dorr LD, Wan Z, Cohen J (1998) Hemispheric titanium porous coated acetabular component without screw fixation. Clin Orthop 351:158–168PubMed Dorr LD, Wan Z, Cohen J (1998) Hemispheric titanium porous coated acetabular component without screw fixation. Clin Orthop 351:158–168PubMed
7.
go back to reference Morscher E, Berli B, Jockers W, Schenk R (1997) Rationale of a flexible press fit cup in total hip replacement. 5-year followup in 280 procedures. Clin Orthop 341:42–50PubMed Morscher E, Berli B, Jockers W, Schenk R (1997) Rationale of a flexible press fit cup in total hip replacement. 5-year followup in 280 procedures. Clin Orthop 341:42–50PubMed
8.
go back to reference Udomkiat P, Dorr LD, Wan Z (2002) Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up. J Bone Joint Surg Am 84-A(7):1195–1200PubMed Udomkiat P, Dorr LD, Wan Z (2002) Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up. J Bone Joint Surg Am 84-A(7):1195–1200PubMed
9.
go back to reference Zicat B, Engh CA, Gokcen E (1995) Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg Am 77:432–439PubMed Zicat B, Engh CA, Gokcen E (1995) Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg Am 77:432–439PubMed
10.
go back to reference Berli BJ, Ping G, Dick W, Morscher EW (2007) Nonmodular flexible press-fit cup in primary total hip arthroplasty: 15-year followup. Clin Orthop Relat Res 461:114–121PubMed Berli BJ, Ping G, Dick W, Morscher EW (2007) Nonmodular flexible press-fit cup in primary total hip arthroplasty: 15-year followup. Clin Orthop Relat Res 461:114–121PubMed
11.
go back to reference Morscher E (1992) Current status of acetabular fixation in primary total hip arthroplasty. Clin Orthop Relat Res 274:172–193PubMed Morscher E (1992) Current status of acetabular fixation in primary total hip arthroplasty. Clin Orthop Relat Res 274:172–193PubMed
12.
go back to reference Gwynne-Jones DP, Garneti N, Wainwright C, Matheson JA, King R (2009) The Morscher press fit acetabular component: a nine- to 13-year review. J Bone Joint Surg Br 91(7):859–864PubMedCrossRef Gwynne-Jones DP, Garneti N, Wainwright C, Matheson JA, King R (2009) The Morscher press fit acetabular component: a nine- to 13-year review. J Bone Joint Surg Br 91(7):859–864PubMedCrossRef
14.
go back to reference Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51(4):737–755PubMed Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51(4):737–755PubMed
15.
go back to reference Merle d’Aubigné RM, Postel M (1954) Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am 36-A:451–475 Merle d’Aubigné RM, Postel M (1954) Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am 36-A:451–475
16.
go back to reference Ware J Jr, Kosinski M, Keller SD (1996) A 12-item short-form health survey: construction of scales and preliminary tests of reliability and validity. Med Care 34(3):220–233PubMedCrossRef Ware J Jr, Kosinski M, Keller SD (1996) A 12-item short-form health survey: construction of scales and preliminary tests of reliability and validity. Med Care 34(3):220–233PubMedCrossRef
17.
go back to reference Beaulé PE, Dorey FJ, Hoke R, Leduff M, Amstutz HC (2006) The value of patient activity level in the outcome of total hip arthroplasty. J Arthroplasty 21(4):547–552PubMedCrossRef Beaulé PE, Dorey FJ, Hoke R, Leduff M, Amstutz HC (2006) The value of patient activity level in the outcome of total hip arthroplasty. J Arthroplasty 21(4):547–552PubMedCrossRef
18.
go back to reference Naal FD, Impellizzeri FM, Leunig M (2009) Which is the best activity rating scale for patients undergoing total joint arthroplasty? Clin Orthop Relat Res 467(4):958–965PubMedCrossRef Naal FD, Impellizzeri FM, Leunig M (2009) Which is the best activity rating scale for patients undergoing total joint arthroplasty? Clin Orthop Relat Res 467(4):958–965PubMedCrossRef
19.
go back to reference DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32PubMed DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32PubMed
20.
go back to reference Martell JM, Berdia S (1997) Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am 79:1635–1641PubMed Martell JM, Berdia S (1997) Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am 79:1635–1641PubMed
21.
go back to reference Sutherland CJ, Wilde AH, Borden LS, Marks KE (1982) A ten-year follow-up of one hundred consecutive Müller curved-stem total hip-replacement arthroplasties. J Bone Joint Surg Am 64(7):970–982PubMed Sutherland CJ, Wilde AH, Borden LS, Marks KE (1982) A ten-year follow-up of one hundred consecutive Müller curved-stem total hip-replacement arthroplasties. J Bone Joint Surg Am 64(7):970–982PubMed
22.
go back to reference Hodgkinson JP, Shelley P, Wroblewski BM (1988) The correlation between the roentgenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties. Clin Orthop Relat Res 228:105–109PubMed Hodgkinson JP, Shelley P, Wroblewski BM (1988) The correlation between the roentgenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties. Clin Orthop Relat Res 228:105–109PubMed
23.
go back to reference Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27PubMed Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27PubMed
24.
go back to reference Clohisy JC, Harris WH (1999) Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. An average ten-year follow-up study. J Bone Joint Surg Am 81(2):247–255PubMed Clohisy JC, Harris WH (1999) Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. An average ten-year follow-up study. J Bone Joint Surg Am 81(2):247–255PubMed
25.
go back to reference Mulroy RD, Estok DM, Harris WH (1995) Total hip arthroplasty with use of so-called second-generation cementing techniques. A fifteen-year-average follow-up study. J Bone Joint Surg Am 77:1845–1852PubMed Mulroy RD, Estok DM, Harris WH (1995) Total hip arthroplasty with use of so-called second-generation cementing techniques. A fifteen-year-average follow-up study. J Bone Joint Surg Am 77:1845–1852PubMed
26.
go back to reference Elke R, Berli B, Wagner A, Morscher EW (2003) Acetabular revision in total hip replacement with a press-fit cup. J Bone Joint Surg Br 85:1114–1119PubMedCrossRef Elke R, Berli B, Wagner A, Morscher EW (2003) Acetabular revision in total hip replacement with a press-fit cup. J Bone Joint Surg Br 85:1114–1119PubMedCrossRef
27.
go back to reference Morscher E, Elke R, Berli B (2000) Classification and treatment methods of acetabular deficiencies. In: Duparc J (ed) Surgical techniques in orthopedics and traumatology. Elsevier, Paris, France, p 55 Morscher E, Elke R, Berli B (2000) Classification and treatment methods of acetabular deficiencies. In: Duparc J (ed) Surgical techniques in orthopedics and traumatology. Elsevier, Paris, France, p 55
28.
go back to reference Barrack RL, Folgueras A, Munn B, Tvetden D, Sharkey P (1997) Pelvic lysis and polyethylene wear at 5–8 years in an uncemented total hip. Clin Orthop 335:211–217PubMed Barrack RL, Folgueras A, Munn B, Tvetden D, Sharkey P (1997) Pelvic lysis and polyethylene wear at 5–8 years in an uncemented total hip. Clin Orthop 335:211–217PubMed
29.
go back to reference Young AM, Sychterz CJ, Hopper RH Jr, Engh CA (2002) Effect of acetabular modularity of polyethylene wear and osteolysis in total hip arthroplasty. J Bone Joint Surg Am 84:58–63PubMed Young AM, Sychterz CJ, Hopper RH Jr, Engh CA (2002) Effect of acetabular modularity of polyethylene wear and osteolysis in total hip arthroplasty. J Bone Joint Surg Am 84:58–63PubMed
30.
go back to reference Kim YH, Kook HK, Kim JS (2002) Total hip replacement with a cementless acetabular component and a cemented femoral component in patients younger than fifty years of age. J Bone Joint Surg Am 84-A(5):770–774PubMed Kim YH, Kook HK, Kim JS (2002) Total hip replacement with a cementless acetabular component and a cemented femoral component in patients younger than fifty years of age. J Bone Joint Surg Am 84-A(5):770–774PubMed
31.
go back to reference García-Rey E, García-Cimbrelo E (2008) Clinical and radiographic results and wear performance in different generations of a cementless porous-coated acetabular cup. Int Orthop 32(2):181–187PubMedCrossRef García-Rey E, García-Cimbrelo E (2008) Clinical and radiographic results and wear performance in different generations of a cementless porous-coated acetabular cup. Int Orthop 32(2):181–187PubMedCrossRef
32.
go back to reference Zichner LP, Willert HG (1992) Comparison of alumina-polyethylene and metalpolyethylene in clinical trials. Clin Orthop 282:86–94PubMed Zichner LP, Willert HG (1992) Comparison of alumina-polyethylene and metalpolyethylene in clinical trials. Clin Orthop 282:86–94PubMed
33.
go back to reference Ritter MA, Thong AE, Davis KE, Berend ME, Meding JB, Faris PM (2004) Long-term deterioration of joint evaluation scores. J Bone Joint Surg Br 86(3):438–442PubMedCrossRef Ritter MA, Thong AE, Davis KE, Berend ME, Meding JB, Faris PM (2004) Long-term deterioration of joint evaluation scores. J Bone Joint Surg Br 86(3):438–442PubMedCrossRef
Metadata
Title
Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws
Authors
Guido Garavaglia
Anne Lübbeke
Christophe Barea
Constantinos Roussos
Robin Peter
Pierre Hoffmeyer
Publication date
01-07-2011
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 7/2011
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-010-1059-8

Other articles of this Issue 7/2011

International Orthopaedics 7/2011 Go to the issue