Skip to main content
Top
Published in: International Orthopaedics 3/2011

01-03-2011 | Original Paper

A cadaveric study of posterior dislocation after total hip replacement—effects of head diameter and acetabular anteversion

Authors: Fu Yuen Ng, Jiang Tao Zhang, Kwong Yuen Chiu, Chun Hoi Yan

Published in: International Orthopaedics | Issue 3/2011

Login to get access

Abstract

The size of the femoral head and acetabular anteversion are crucial for stability in total hip replacements. This study examined the effects of head diameter and acetabular anteversion on the posterior instability after total hip replacement in an in vivo setting. The acetabular shell was inserted at 0–20° of anteversion at five degree intervals. By using different head sizes (28 mm, 32 mm, 36 mm), the degrees of dislocation were recorded by computer navigation. The 36-mm group consistently showed better stability compared with the 32- and 28-mm groups, regardless of the degree of cup anteversion. Within each group of head size, the hip was significantly more stable when the cup anteversion increased from 0° to 10°. The difference became insignificant when it increased from 15° to 20°.
Literature
1.
go back to reference Soong M, Rubash H, Macaulay W (2004) Dislocation after total hip arthroplasty. J Am Acad Orthop Surg 12:314–321PubMed Soong M, Rubash H, Macaulay W (2004) Dislocation after total hip arthroplasty. J Am Acad Orthop Surg 12:314–321PubMed
2.
go back to reference Burroughs BR, Hallstrom B, Golladay GJ, Hoeffel D, Harris WH (2005) Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes. J Arthroplasty 20:11–19PubMedCrossRef Burroughs BR, Hallstrom B, Golladay GJ, Hoeffel D, Harris WH (2005) Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes. J Arthroplasty 20:11–19PubMedCrossRef
3.
go back to reference Woo R, Morrey B (1982) Dislocations after total hip arthroplasty. J Bone Joint Surg Am 64:1295–1306PubMed Woo R, Morrey B (1982) Dislocations after total hip arthroplasty. J Bone Joint Surg Am 64:1295–1306PubMed
4.
go back to reference Berry DJ, von Knoch M, Schleck CD, Harmsen WS (2005) Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am 87:2456–2463PubMedCrossRef Berry DJ, von Knoch M, Schleck CD, Harmsen WS (2005) Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am 87:2456–2463PubMedCrossRef
5.
go back to reference Geller JA, Malchau H, Bragdon C, Greene M, Harris WH, Freiberg AA (2006) Large diameter femoral heads on highly cross-linked polyethylene. Clin Orthop Relat Res 447:53–59PubMedCrossRef Geller JA, Malchau H, Bragdon C, Greene M, Harris WH, Freiberg AA (2006) Large diameter femoral heads on highly cross-linked polyethylene. Clin Orthop Relat Res 447:53–59PubMedCrossRef
6.
go back to reference Beaule PE, Schmalzried TP, Udomkiat P, Amstutz HC (2002) Jumbo femoral head for the treatment of recurrent dislocation following total hip replacement. J Bone Joint Surg Am 84:256–263PubMed Beaule PE, Schmalzried TP, Udomkiat P, Amstutz HC (2002) Jumbo femoral head for the treatment of recurrent dislocation following total hip replacement. J Bone Joint Surg Am 84:256–263PubMed
7.
go back to reference Bosker BH, Ettemma HB, Verheyen CCPM, Castelein RM (2009) Acetabular augmentation ring for recurrent dislocation of total hip arthroplasty: 60% stability rate after an average follow-up of 74 months. Int Orthop 33:49–52PubMedCrossRef Bosker BH, Ettemma HB, Verheyen CCPM, Castelein RM (2009) Acetabular augmentation ring for recurrent dislocation of total hip arthroplasty: 60% stability rate after an average follow-up of 74 months. Int Orthop 33:49–52PubMedCrossRef
8.
go back to reference Etienne A, Cupic Z, Charnley J (1978) Postoperative dislocation after Charnley low friction arthroplasty. Clin Orthop Relat Res 132:19–23PubMed Etienne A, Cupic Z, Charnley J (1978) Postoperative dislocation after Charnley low friction arthroplasty. Clin Orthop Relat Res 132:19–23PubMed
9.
go back to reference Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip replacement arthroplasty. J Bone Joint Surg Am 60:217–220PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip replacement arthroplasty. J Bone Joint Surg Am 60:217–220PubMed
10.
go back to reference Paterno SA, Lachiewicz PF, Kelley SS (1997) The influence of patient-related factors and the position of the acetabular component on the rate of dislocation after total hip replacement. J Bone Joint Surg Am 79:1202–1210PubMed Paterno SA, Lachiewicz PF, Kelley SS (1997) The influence of patient-related factors and the position of the acetabular component on the rate of dislocation after total hip replacement. J Bone Joint Surg Am 79:1202–1210PubMed
11.
go back to reference Pierchon F, Pasquier G, Cotton A, Fontaine C, Clarisse J, Duquennoy A (1994) Causes of dislocation of total hip arthroplasty: CT study of component alignment. J Bone Joint Surg Br 76:45–48PubMed Pierchon F, Pasquier G, Cotton A, Fontaine C, Clarisse J, Duquennoy A (1994) Causes of dislocation of total hip arthroplasty: CT study of component alignment. J Bone Joint Surg Br 76:45–48PubMed
12.
go back to reference Masaoka T, Yamamoto K, Shishido T, Katori Y, Mizoue T, Shirasu H, Nunoda D (2006) Study of hip joint dislocation after total hip arthroplasty. Int Orthop 30:26–30PubMedCrossRef Masaoka T, Yamamoto K, Shishido T, Katori Y, Mizoue T, Shirasu H, Nunoda D (2006) Study of hip joint dislocation after total hip arthroplasty. Int Orthop 30:26–30PubMedCrossRef
13.
go back to reference Livermore J, Ilstrup D, Morrey B (1990) Effect of femoral head size on wear of polyethylene of the polyethylene acetabular component. J Bone Joint Surg Am 72:518–528PubMed Livermore J, Ilstrup D, Morrey B (1990) Effect of femoral head size on wear of polyethylene of the polyethylene acetabular component. J Bone Joint Surg Am 72:518–528PubMed
14.
go back to reference Bartz RL, Noble PC, Kadakia NR, Tullos HS (2000) The effect of femoral component head size on posterior dislocation of the artificial hip joint. J Bone Joint Surg Am 82:1300–1307PubMed Bartz RL, Noble PC, Kadakia NR, Tullos HS (2000) The effect of femoral component head size on posterior dislocation of the artificial hip joint. J Bone Joint Surg Am 82:1300–1307PubMed
15.
go back to reference Sariali E, Lazennec JY, Khiami F, Catonne Y (2009) Mathematical evaluation of jumping distance in total hip arthroplasty: influence of abduction angle, femoral head offset, and head diameter. Acta Ortho 80:277–282CrossRef Sariali E, Lazennec JY, Khiami F, Catonne Y (2009) Mathematical evaluation of jumping distance in total hip arthroplasty: influence of abduction angle, femoral head offset, and head diameter. Acta Ortho 80:277–282CrossRef
16.
go back to reference Crowninshield RD, Maloney WJ, Wentz DH, Humphrey SM, Blanchard CR (2004) Biomechanics of large femoral heads. Clin Orthop 429:102–107PubMedCrossRef Crowninshield RD, Maloney WJ, Wentz DH, Humphrey SM, Blanchard CR (2004) Biomechanics of large femoral heads. Clin Orthop 429:102–107PubMedCrossRef
17.
go back to reference Prietzel T, Richter KW, von Salis-Soglio G (2007) The stabilizing effect of atmospheric pressure (AP) on hip joint subject to traction force—an experimental study. Z Orthop Unfall 145:468–475PubMedCrossRef Prietzel T, Richter KW, von Salis-Soglio G (2007) The stabilizing effect of atmospheric pressure (AP) on hip joint subject to traction force—an experimental study. Z Orthop Unfall 145:468–475PubMedCrossRef
18.
go back to reference Kung PL, Ries MD (2007) Effect of femoral head size and abductors on dislocation after revision THA. Clin Orthop Rel Res 465:170–174 Kung PL, Ries MD (2007) Effect of femoral head size and abductors on dislocation after revision THA. Clin Orthop Rel Res 465:170–174
19.
go back to reference Chiu KY, Tang WM, Ng TP (2001) Cementless total hip arthroplasty in young Chinese patients. J Arthroplasty 16:863–870PubMedCrossRef Chiu KY, Tang WM, Ng TP (2001) Cementless total hip arthroplasty in young Chinese patients. J Arthroplasty 16:863–870PubMedCrossRef
20.
go back to reference Ng TP, Yau WP, Tang WM, Chiu KY (2003) Anterior dislocation following primary total hip replacement by posterior approach—aetiology and treatment. Hong Kong J Orthop Surg 7:14–18 Ng TP, Yau WP, Tang WM, Chiu KY (2003) Anterior dislocation following primary total hip replacement by posterior approach—aetiology and treatment. Hong Kong J Orthop Surg 7:14–18
Metadata
Title
A cadaveric study of posterior dislocation after total hip replacement—effects of head diameter and acetabular anteversion
Authors
Fu Yuen Ng
Jiang Tao Zhang
Kwong Yuen Chiu
Chun Hoi Yan
Publication date
01-03-2011
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 3/2011
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-010-0977-9

Other articles of this Issue 3/2011

International Orthopaedics 3/2011 Go to the issue