Skip to main content
Top
Published in: International Orthopaedics 4/2011

01-04-2011 | Original Paper

Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study

Authors: David Campbell, Graham Mercer, Kjell G. Nilsson, Vanessa Wells, John R. Field, Stuart A. Callary

Published in: International Orthopaedics | Issue 4/2011

Login to get access

Abstract

Measurement of early stem subsidence can be used to predict the likelihood of long-term femoral component loosening and clinical failure. Data that examines the early migration pattern of clinically proven stems will provide clinicians with useful baseline data with which to compare new stem designs. This study was performed to evaluate the early migration pattern of a hydroxyapatite-coated press-fit femoral component that has been in use for over ten years. We enrolled 30 patients who underwent THA for osteoarthritis. The median age was 70 years (range, 55–80 years). Patients were clinically assessed using the Harris hip score. Radiostereometric analysis was used to evaluate stem migration at three to four days, six months, one year and two years. We observed a mean subsidence of 0.73 mm at six months, 0.62 mm at one year and 0.58 mm at two years and a mean retroversion of 1.82° at six months, 1.90° at one year and 1.59° at two years. This data suggests that subsidence is confined to the first six months after which there was no further subsidence. The results from this study can be compared with those from novel cementless stem designs to help predict the long-term outcome one may expect from new cementless stem designs.
Literature
1.
go back to reference Australian Orthopaedic Association National Joint Replacement Registry (2008) Annual Report. AOA, Adelaide Australian Orthopaedic Association National Joint Replacement Registry (2008) Annual Report. AOA, Adelaide
2.
go back to reference Kurtz S, Ong K, Lau E, Mowat F, Halpern M (2007) Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 89:780–785PubMedCrossRef Kurtz S, Ong K, Lau E, Mowat F, Halpern M (2007) Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 89:780–785PubMedCrossRef
3.
go back to reference Mazoochian F, Schrimpf FM, Kircher J, Mayer W, Hauptmann S, Fottner A, Muller PE, Pellengahr C, Jansson V (2007) Proximal loading of the femur leads to low subsidence rates: first clinical results of the CR-stem. Arch Orthop Trauma Surg 127:397–401PubMedCrossRef Mazoochian F, Schrimpf FM, Kircher J, Mayer W, Hauptmann S, Fottner A, Muller PE, Pellengahr C, Jansson V (2007) Proximal loading of the femur leads to low subsidence rates: first clinical results of the CR-stem. Arch Orthop Trauma Surg 127:397–401PubMedCrossRef
4.
go back to reference Parvizi J, Keisu KS, Hozack WJ, Sharkey PF, Rothman RH (2004) Primary total hip arthroplasty with an uncemented femoral component: a long-term study of the Taperloc stem. J Arthroplasty 19:151–156PubMedCrossRef Parvizi J, Keisu KS, Hozack WJ, Sharkey PF, Rothman RH (2004) Primary total hip arthroplasty with an uncemented femoral component: a long-term study of the Taperloc stem. J Arthroplasty 19:151–156PubMedCrossRef
5.
go back to reference Makela KT, Eskelinen A, Pulkkinen P, Paavolainen P, Remes V (2008) Total hip arthroplasty for primary osteoarthritis in patients fifty-five years of age or older. An analysis of the Finnish arthroplasty registry. J Bone Joint Surg Am 90:2160–2170PubMedCrossRef Makela KT, Eskelinen A, Pulkkinen P, Paavolainen P, Remes V (2008) Total hip arthroplasty for primary osteoarthritis in patients fifty-five years of age or older. An analysis of the Finnish arthroplasty registry. J Bone Joint Surg Am 90:2160–2170PubMedCrossRef
6.
go back to reference Lubbeke A, Katz JN, Perneger TV, Hoffmeyer P (2007) Primary and revision hip arthroplasty: 5-year outcomes and influence of age and comorbidity. J Rheumatol 34:394–400PubMed Lubbeke A, Katz JN, Perneger TV, Hoffmeyer P (2007) Primary and revision hip arthroplasty: 5-year outcomes and influence of age and comorbidity. J Rheumatol 34:394–400PubMed
7.
go back to reference Gheduzzi S, Miles AW (2007) A review of pre-clinical testing of femoral stem subsidence and comparison with clinical data. Proc Inst Mech Eng [H] 221:39–46 Gheduzzi S, Miles AW (2007) A review of pre-clinical testing of femoral stem subsidence and comparison with clinical data. Proc Inst Mech Eng [H] 221:39–46
8.
go back to reference Froimson MI, Garino J, Machenaud A, Vidalain JP (2007) Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem: an independent review. J Arthroplasty 22:1–7PubMedCrossRef Froimson MI, Garino J, Machenaud A, Vidalain JP (2007) Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem: an independent review. J Arthroplasty 22:1–7PubMedCrossRef
9.
go back to reference Karrholm J, Borssen B, Lowenhielm G, Snorrason F (1994) Does early micromotion of femoral stem prostheses matter? 4–7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg Br 76:912–917PubMed Karrholm J, Borssen B, Lowenhielm G, Snorrason F (1994) Does early micromotion of femoral stem prostheses matter? 4–7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg Br 76:912–917PubMed
10.
go back to reference Karrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J (1997) Radiostereometry of hip prostheses. Review of methodology and clinical results. Clin Orthop Relat Res 94–110 Karrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J (1997) Radiostereometry of hip prostheses. Review of methodology and clinical results. Clin Orthop Relat Res 94–110
11.
go back to reference Malchau H, Karrholm J, Wang YX, Herberts P (1995) Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiostereometry in 51 patients. Acta Orthop Scand 66:418–424PubMedCrossRef Malchau H, Karrholm J, Wang YX, Herberts P (1995) Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiostereometry in 51 patients. Acta Orthop Scand 66:418–424PubMedCrossRef
12.
go back to reference Onsten I, Berzins A, Shott S, Sumner DR (2001) Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: human and canine in vitro models. J Orthop Res 19:1162–1167PubMedCrossRef Onsten I, Berzins A, Shott S, Sumner DR (2001) Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: human and canine in vitro models. J Orthop Res 19:1162–1167PubMedCrossRef
13.
go back to reference Bragdon CR, Greene ME, Freiberg AA, Harris WH, Malchau H (2007) Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs 28-mm femoral heads. J Arthroplasty 22:125–129PubMedCrossRef Bragdon CR, Greene ME, Freiberg AA, Harris WH, Malchau H (2007) Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs 28-mm femoral heads. J Arthroplasty 22:125–129PubMedCrossRef
14.
go back to reference Grant P, Aamodt A, Falch JA, Nordsletten L (2005) Differences in stability and bone remodeling between a customized uncemented hydroxyapatite coated and a standard cemented femoral stem. A randomized study with use of radiostereometry and bone densitometry. J Orthop Res 23:1280–1285PubMed Grant P, Aamodt A, Falch JA, Nordsletten L (2005) Differences in stability and bone remodeling between a customized uncemented hydroxyapatite coated and a standard cemented femoral stem. A randomized study with use of radiostereometry and bone densitometry. J Orthop Res 23:1280–1285PubMed
15.
go back to reference Stefansdottir A, Franzen H, Johnsson R, Ornstein E, Sundberg M (2004) Movement pattern of the Exeter femoral stem; a radiostereometric analysis of 22 primary hip arthroplasties followed for 5 years. Acta Orthop Scand 75:408–414PubMedCrossRef Stefansdottir A, Franzen H, Johnsson R, Ornstein E, Sundberg M (2004) Movement pattern of the Exeter femoral stem; a radiostereometric analysis of 22 primary hip arthroplasties followed for 5 years. Acta Orthop Scand 75:408–414PubMedCrossRef
16.
go back to reference Hallan G, Lie SA, Furnes O, Engesaeter LB, Vollset SE, Havelin LI (2007) Medium- and long-term performance of 11,516 uncemented primary femoral stems from the Norwegian arthroplasty register. J Bone Joint Surg Br 89:1574–1580PubMedCrossRef Hallan G, Lie SA, Furnes O, Engesaeter LB, Vollset SE, Havelin LI (2007) Medium- and long-term performance of 11,516 uncemented primary femoral stems from the Norwegian arthroplasty register. J Bone Joint Surg Br 89:1574–1580PubMedCrossRef
17.
go back to reference Reikeras O, Gunderson RB (2003) Excellent results of HA coating on a grit-blasted stem: 245 patients followed for 8–12 years. Acta Orthop Scand 74:140–145PubMedCrossRef Reikeras O, Gunderson RB (2003) Excellent results of HA coating on a grit-blasted stem: 245 patients followed for 8–12 years. Acta Orthop Scand 74:140–145PubMedCrossRef
18.
go back to reference Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:737–755PubMed Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:737–755PubMed
19.
go back to reference Valstar ER, Gill R, Ryd L, Flivik G, Borlin N, Karrholm J (2005) Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 76:563–572PubMedCrossRef Valstar ER, Gill R, Ryd L, Flivik G, Borlin N, Karrholm J (2005) Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 76:563–572PubMedCrossRef
20.
go back to reference Krismer M, Biedermann R, Stockl B, Fischer M, Bauer R, Haid C (1999) The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. Einzel-Bild-Roentgen-Analyse-femoral component analysis. J Bone Joint Surg Br 81:273–280PubMedCrossRef Krismer M, Biedermann R, Stockl B, Fischer M, Bauer R, Haid C (1999) The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. Einzel-Bild-Roentgen-Analyse-femoral component analysis. J Bone Joint Surg Br 81:273–280PubMedCrossRef
21.
go back to reference Strom H, Mallmin H, Milbrink J, Petren-Mallmin M, Nivbrant B, Kolstad K (2003) The cone hip stem: a prospective study of 13 patients followed for 5 years with RSA. Acta Orthop Scand 74:525–530PubMedCrossRef Strom H, Mallmin H, Milbrink J, Petren-Mallmin M, Nivbrant B, Kolstad K (2003) The cone hip stem: a prospective study of 13 patients followed for 5 years with RSA. Acta Orthop Scand 74:525–530PubMedCrossRef
22.
go back to reference Strom H, Nilsson O, Milbrink J, Mallmin H, Larsson S (2007) Early migration pattern of the uncemented CLS stem in total hip arthroplasties. Clin Orthop Relat Res 454:127–132PubMedCrossRef Strom H, Nilsson O, Milbrink J, Mallmin H, Larsson S (2007) Early migration pattern of the uncemented CLS stem in total hip arthroplasties. Clin Orthop Relat Res 454:127–132PubMedCrossRef
23.
go back to reference Strom H, Nilsson O, Milbrink J, Mallmin H, Larsson S (2007) The effect of early weight bearing on migration pattern of the uncemented CLS stem in total hip arthroplasty. J Arthroplasty 22:1122–1129PubMedCrossRef Strom H, Nilsson O, Milbrink J, Mallmin H, Larsson S (2007) The effect of early weight bearing on migration pattern of the uncemented CLS stem in total hip arthroplasty. J Arthroplasty 22:1122–1129PubMedCrossRef
24.
go back to reference Kroell A, Beaule P, Krismer M, Behensky H, Stoeckl B, Biedermann R (2008) Aseptic stem loosening in primary THA: migration analysis of cemented and cementless fixation. Int Orthop. doi:10.1007/s00264-008-0701-1 PubMed Kroell A, Beaule P, Krismer M, Behensky H, Stoeckl B, Biedermann R (2008) Aseptic stem loosening in primary THA: migration analysis of cemented and cementless fixation. Int Orthop. doi:10.​1007/​s00264-008-0701-1 PubMed
Metadata
Title
Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study
Authors
David Campbell
Graham Mercer
Kjell G. Nilsson
Vanessa Wells
John R. Field
Stuart A. Callary
Publication date
01-04-2011
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 4/2011
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-009-0913-z

Other articles of this Issue 4/2011

International Orthopaedics 4/2011 Go to the issue