Skip to main content
Top
Published in: International Orthopaedics 4/2010

01-04-2010 | Original Paper

Nailing versus plating in humerus shaft fractures: A prospective comparative study

Authors: Kiran Singisetti, M. Ambedkar

Published in: International Orthopaedics | Issue 4/2010

Login to get access

Abstract

There is a debate about the choice of operative intervention in humerus shaft fractures requiring surgical intervention. A prospective, comparative study of management of acute humeral shaft fractures treated by antegrade interlocking nail fixation and dynamic compression plating was undertaken over a period of three years. Twenty patients of interlocking nailing and sixteen patients of plating were included after considering the inclusion and exclusion criteria. Functional scoring criteria were used for postoperative assessment and the average follow-up period was one year. A higher rate of excellent and good results and a tendency for earlier union was seen with the plating group in our series.
Literature
1.
go back to reference An Z, Zeng B, He X, Chen Q, Hu S (2009) Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique. Int Orthop Epub Mar 20 An Z, Zeng B, He X, Chen Q, Hu S (2009) Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique. Int Orthop Epub Mar 20
2.
go back to reference Bell MJ, Beauchamp CG, Kellam JK, McMurtry RY (1985) The results of plating humeral shaft fractures in patients with multiple injuries. The Sunnybrook experience. J Bone Joint Surg Br 67(2):293–296 Bell MJ, Beauchamp CG, Kellam JK, McMurtry RY (1985) The results of plating humeral shaft fractures in patients with multiple injuries. The Sunnybrook experience. J Bone Joint Surg Br 67(2):293–296
3.
go back to reference Bhandari M, Devereaux PJ, McKee MD, Schemitsch EH (2006) Compression plating versus intramedullary nailing of humeral shaft fractures—a meta-analysis. Acta Orthop 77(2):279–284CrossRefPubMed Bhandari M, Devereaux PJ, McKee MD, Schemitsch EH (2006) Compression plating versus intramedullary nailing of humeral shaft fractures—a meta-analysis. Acta Orthop 77(2):279–284CrossRefPubMed
4.
go back to reference Brumback RJ, Bosse MJ, Poka A, Burgess AR (1986) Intramedullary stabilization of humeral shaft fractures in patients with multiple trauma. J Bone Joint Surg Am 68(7):960–970PubMed Brumback RJ, Bosse MJ, Poka A, Burgess AR (1986) Intramedullary stabilization of humeral shaft fractures in patients with multiple trauma. J Bone Joint Surg Am 68(7):960–970PubMed
5.
go back to reference Chao TC, Chou WY, Chung JC, Hsu CJ (2005) Humeral shaft fractures treated by dynamic compression plates, Ender nails and interlocking nails. Int Orthop 29(2):88–91CrossRefPubMed Chao TC, Chou WY, Chung JC, Hsu CJ (2005) Humeral shaft fractures treated by dynamic compression plates, Ender nails and interlocking nails. Int Orthop 29(2):88–91CrossRefPubMed
6.
go back to reference Changulani M, Jain UK, Keswani T (2007) Comparison of the use of the humerus intramedullary nail and dynamic compression plate for the management of diaphyseal fractures of the humerus. A randomised controlled study. Int Orthop 31(3):391–395CrossRefPubMed Changulani M, Jain UK, Keswani T (2007) Comparison of the use of the humerus intramedullary nail and dynamic compression plate for the management of diaphyseal fractures of the humerus. A randomised controlled study. Int Orthop 31(3):391–395CrossRefPubMed
7.
go back to reference Chapman JR, Henley MB, Agel J, Benca PJ (2000) Randomized prospective study of humeral shaft fracture fixation: Intramedullary nails versus plates. J Orthop Trauma 14:162–166CrossRefPubMed Chapman JR, Henley MB, Agel J, Benca PJ (2000) Randomized prospective study of humeral shaft fracture fixation: Intramedullary nails versus plates. J Orthop Trauma 14:162–166CrossRefPubMed
8.
go back to reference Foster RJ, Dixon GL Jr, Bach AW, Appleyard RW, Green TM (1985) Internal fixation of fractures and non-unions of the humeral shaft. Indications and results in a multi-center study. J Bone Joint Surg Am 67(6):857–864PubMed Foster RJ, Dixon GL Jr, Bach AW, Appleyard RW, Green TM (1985) Internal fixation of fractures and non-unions of the humeral shaft. Indications and results in a multi-center study. J Bone Joint Surg Am 67(6):857–864PubMed
9.
go back to reference Hall RF Jr, Pankovich AM (1987) Ender nailing of acute fractures of the humerus. A study of closed fixation by intramedullary nails without reaming. J Bone Joint Surg Am 69(4):558–567PubMed Hall RF Jr, Pankovich AM (1987) Ender nailing of acute fractures of the humerus. A study of closed fixation by intramedullary nails without reaming. J Bone Joint Surg Am 69(4):558–567PubMed
10.
go back to reference Ji F, Tong D, Tang H, Cai X, Zhang Q, Li J, Wang Q (2009) Minimally invasive percutaneous plate osteosynthesis (MIPPO) technique applied in the treatment of humeral shaft distal fractures through a lateral approach. Int Orthop 33(2):543–547CrossRefPubMed Ji F, Tong D, Tang H, Cai X, Zhang Q, Li J, Wang Q (2009) Minimally invasive percutaneous plate osteosynthesis (MIPPO) technique applied in the treatment of humeral shaft distal fractures through a lateral approach. Int Orthop 33(2):543–547CrossRefPubMed
11.
go back to reference Klenerman L (1966) Fractures of the shaft of the humerus. J Bone Joint Surg Br 48(1):105–111PubMed Klenerman L (1966) Fractures of the shaft of the humerus. J Bone Joint Surg Br 48(1):105–111PubMed
12.
go back to reference Livani B, Belangero W, Andrade K, Zuiani G, Pratali R (2008) Is MIPO in humeral shaft fractures really safe? Postoperative ultrasonographic evaluation. Int Orthop Epub Aug 13 Livani B, Belangero W, Andrade K, Zuiani G, Pratali R (2008) Is MIPO in humeral shaft fractures really safe? Postoperative ultrasonographic evaluation. Int Orthop Epub Aug 13
13.
go back to reference McCormack RG, Brien D, Buckley RE, McKee MD, Powell J, Schemitsch EH (2000) Fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail: A prospective randomized trial. J Bone Joint Surg Br 82(3):336–339CrossRefPubMed McCormack RG, Brien D, Buckley RE, McKee MD, Powell J, Schemitsch EH (2000) Fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail: A prospective randomized trial. J Bone Joint Surg Br 82(3):336–339CrossRefPubMed
14.
go back to reference Pollock FH, Drake D, Bovill EG, Day L, Trafton PG (1981) Treatment of radial neuropathy associated with fractures of the humerus. J Bone Joint Surg Am 63(2):239–243PubMed Pollock FH, Drake D, Bovill EG, Day L, Trafton PG (1981) Treatment of radial neuropathy associated with fractures of the humerus. J Bone Joint Surg Am 63(2):239–243PubMed
15.
go back to reference Raghavendra S, Bhalodiya HP (2007) Internal fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail: A prospective study. Indian J Orthop 41(3):214–218CrossRef Raghavendra S, Bhalodiya HP (2007) Internal fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail: A prospective study. Indian J Orthop 41(3):214–218CrossRef
16.
go back to reference Rodríguez-Merchán EC (1995) Compression plating versus Hackethal nailing in closed humeral shaft fractures failing nonoperative reduction. J Orthop Trauma 9(3):194–197PubMedCrossRef Rodríguez-Merchán EC (1995) Compression plating versus Hackethal nailing in closed humeral shaft fractures failing nonoperative reduction. J Orthop Trauma 9(3):194–197PubMedCrossRef
17.
go back to reference Stern PJ, Mattingly DA, Pomeroy DL, Zenni EJ Jr, Kreig JK (1984) Intramedullary fixation of humeral shaft fractures. J Bone Joint Surg Am 66(5):639–646PubMed Stern PJ, Mattingly DA, Pomeroy DL, Zenni EJ Jr, Kreig JK (1984) Intramedullary fixation of humeral shaft fractures. J Bone Joint Surg Am 66(5):639–646PubMed
18.
go back to reference Sarmiento A, Kinman PB, Galvin EG, Schmitt RH, Phillips JG (1977) Functional bracing of fractures of the shaft of the humerus. J Bone Joint Surg Am 59A:596–601 Sarmiento A, Kinman PB, Galvin EG, Schmitt RH, Phillips JG (1977) Functional bracing of fractures of the shaft of the humerus. J Bone Joint Surg Am 59A:596–601
19.
go back to reference Sarmiento A, Waddell JP, Latta LL (2002) Diaphyseal humeral fractures: Treatment options. Instr Course Lect 51:257–269PubMed Sarmiento A, Waddell JP, Latta LL (2002) Diaphyseal humeral fractures: Treatment options. Instr Course Lect 51:257–269PubMed
20.
go back to reference Tsai CH, Fong YC, Chen YH, Hsu CJ, Chang CH, Hsu HC (2009) The epidemiology of traumatic humeral shaft fractures in Taiwan. Int Orthop 33(2):463–467CrossRefPubMed Tsai CH, Fong YC, Chen YH, Hsu CJ, Chang CH, Hsu HC (2009) The epidemiology of traumatic humeral shaft fractures in Taiwan. Int Orthop 33(2):463–467CrossRefPubMed
Metadata
Title
Nailing versus plating in humerus shaft fractures: A prospective comparative study
Authors
Kiran Singisetti
M. Ambedkar
Publication date
01-04-2010
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 4/2010
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-009-0813-2

Other articles of this Issue 4/2010

International Orthopaedics 4/2010 Go to the issue