Abstract

The Anterior Pelvic Plane (APP), defined by the anterior superior iliac spines and the pubic tubercle, was commonly used as reference for positioning and postoperative evaluation of the orientation of the acetabular cup in total hip arthroplasty. APP was assumed to be vertical, but was not observed always so, mostly because of associated spinal diseases inducing perturbations in the harmony of the sagittal balance of the pelvi-spinal unit. Consequently a sagittal rotation of the pelvis occurs, and so a tilt of the APP which alters directly the orientation of the cup in upright position. An analysis of the APP tilt related to the sagittal balance of the spine was provided and its implication on the cup orientation. It appeared essential for an individual adjustment of the cup positioning to avoid a functional mal-position which can lead to an increased risk of dislocation and impingement.
Appendix
Available only for authorised users
Literature
1.
go back to reference Ackland MK, Bourne WB, Uhthoff HK (1986) Anteversion of the acetabular cup. Measurement of angle after total hip replacement. J Bone Joint Surg Br 68:409–413PubMed Ackland MK, Bourne WB, Uhthoff HK (1986) Anteversion of the acetabular cup. Measurement of angle after total hip replacement. J Bone Joint Surg Br 68:409–413PubMed
2.
go back to reference Anda S, Svennneingen S, Grontvdt T, Benum P (1990) Pelvic inclination and spatial orientation of the acetabulum. A radiographic, computed tomographic and clinical investigation. Acta Radiol 31(4):389–394CrossRefPubMed Anda S, Svennneingen S, Grontvdt T, Benum P (1990) Pelvic inclination and spatial orientation of the acetabulum. A radiographic, computed tomographic and clinical investigation. Acta Radiol 31(4):389–394CrossRefPubMed
3.
go back to reference Babisch JW, Layher F, Amiot LP (2008) The rationale for tilt-adjusted cup navigation. J Bone Joint Surg Am 90(2):357–365CrossRefPubMed Babisch JW, Layher F, Amiot LP (2008) The rationale for tilt-adjusted cup navigation. J Bone Joint Surg Am 90(2):357–365CrossRefPubMed
4.
go back to reference Chen E, Goertz W, Lill CA (2006) Implant position calculation for acetabular cup placement considering pelvic lateral tilt and inclination. Comput Aided Surg 11(6):309–316CrossRefPubMed Chen E, Goertz W, Lill CA (2006) Implant position calculation for acetabular cup placement considering pelvic lateral tilt and inclination. Comput Aided Surg 11(6):309–316CrossRefPubMed
5.
go back to reference DiGioia AM, Hafez MA, Jaramaz B, Levison TJ, Moody JE (2006) Functional pelvic orientation measured from lateral standing and sitting radiographs. Clin Orthop Relat Res 453:272–276CrossRefPubMed DiGioia AM, Hafez MA, Jaramaz B, Levison TJ, Moody JE (2006) Functional pelvic orientation measured from lateral standing and sitting radiographs. Clin Orthop Relat Res 453:272–276CrossRefPubMed
6.
go back to reference Eddine TA, Migaud H, Chantelot C, Cotten A, Fontaine C, Duquennoy A (2001) Variations of pelvic anteversion in the lying and standing positions: analysis of 24 control subjects and implications for CT measurement of position of a prosthetic cup. Surg Radiol Anat 23(2):105–110CrossRefPubMed Eddine TA, Migaud H, Chantelot C, Cotten A, Fontaine C, Duquennoy A (2001) Variations of pelvic anteversion in the lying and standing positions: analysis of 24 control subjects and implications for CT measurement of position of a prosthetic cup. Surg Radiol Anat 23(2):105–110CrossRefPubMed
7.
go back to reference Kalteis T, Handel M, Bäthis H, Perlick L, Tingart M, Grifka J (2006) Imageless navigation for insertion of the acetabular component in total hip arthroplasty. J Bone Joint Surg Br 88(2):163–167CrossRefPubMed Kalteis T, Handel M, Bäthis H, Perlick L, Tingart M, Grifka J (2006) Imageless navigation for insertion of the acetabular component in total hip arthroplasty. J Bone Joint Surg Br 88(2):163–167CrossRefPubMed
8.
go back to reference Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ (1998) Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear and component migration. J Arthroplasty 13(5):530–534CrossRefPubMed Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ (1998) Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear and component migration. J Arthroplasty 13(5):530–534CrossRefPubMed
9.
go back to reference Lazennec JY, Charlot N, Gorin M, Roger B, Arafati N, Bissery A, Saillant G (2004) Hip-spine relationship: a radio-anatomical study for optimization in acetabular cup positioning. Surg Radiol Anat 26:136–144CrossRefPubMed Lazennec JY, Charlot N, Gorin M, Roger B, Arafati N, Bissery A, Saillant G (2004) Hip-spine relationship: a radio-anatomical study for optimization in acetabular cup positioning. Surg Radiol Anat 26:136–144CrossRefPubMed
10.
go back to reference Leenders T, Vandevelde D, Mahieu G, Nuyts R (2002) Reduction in variability of acetabular abduction using computer-assisted surgery: a prospective and randomized study. Computed Aided Surg 7:99–106CrossRef Leenders T, Vandevelde D, Mahieu G, Nuyts R (2002) Reduction in variability of acetabular abduction using computer-assisted surgery: a prospective and randomized study. Computed Aided Surg 7:99–106CrossRef
11.
go back to reference Legaye J, Duval-Beaupere G, Hecquet J, Marty C (1998) Pelvic incidence: a fundamental pelvic parameter for three-dimensional regulation of spinal sagittal curves. Eur Spine J 7:99–103CrossRefPubMed Legaye J, Duval-Beaupere G, Hecquet J, Marty C (1998) Pelvic incidence: a fundamental pelvic parameter for three-dimensional regulation of spinal sagittal curves. Eur Spine J 7:99–103CrossRefPubMed
12.
go back to reference Legaye J, Duval-Beaupère G (2007) Gravitational forces and sagittal shape of the spine. Clinical estimation of their relations. Int Orthop, Epub jul 25, 2007 Legaye J, Duval-Beaupère G (2007) Gravitational forces and sagittal shape of the spine. Clinical estimation of their relations. Int Orthop, Epub jul 25, 2007
13.
go back to reference Lembeck B, Mueller O, Reize P, Wuelker N (2005) Pelvic tilt makes acetabular cup navigation inaccurate. Acta Orthop 76(4):517–523PubMedCrossRef Lembeck B, Mueller O, Reize P, Wuelker N (2005) Pelvic tilt makes acetabular cup navigation inaccurate. Acta Orthop 76(4):517–523PubMedCrossRef
14.
go back to reference Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplaties. J Bone Joint Surg Am 60(2):217–220PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplaties. J Bone Joint Surg Am 60(2):217–220PubMed
15.
go back to reference Mayr E, Kessler O, Prassl A, Rachbauer F, Krismer M, Nogler M (2005) The frontal pelvic plane provides a valid reference system for implantation of the acetabular cup: spatial orientation of the pelvis in different positions. Acta Orthop 76(6):848–853CrossRefPubMed Mayr E, Kessler O, Prassl A, Rachbauer F, Krismer M, Nogler M (2005) The frontal pelvic plane provides a valid reference system for implantation of the acetabular cup: spatial orientation of the pelvis in different positions. Acta Orthop 76(6):848–853CrossRefPubMed
16.
go back to reference McCollum DE, Gray WJ (1990) Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop Relat Res 261:159–170PubMed McCollum DE, Gray WJ (1990) Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop Relat Res 261:159–170PubMed
17.
go back to reference Pinoit Y, May O, Girard J, Laffargue P, Ala Eddine T, Migaud H (2007) Low accuracy of the anterior pelvic plane to guide the position of the cup with imageless computer assistance: variation of position in 106 patients. Rev Chir Orthop Reparatrice Appar Mot 93(5):455–460PubMed Pinoit Y, May O, Girard J, Laffargue P, Ala Eddine T, Migaud H (2007) Low accuracy of the anterior pelvic plane to guide the position of the cup with imageless computer assistance: variation of position in 106 patients. Rev Chir Orthop Reparatrice Appar Mot 93(5):455–460PubMed
18.
go back to reference Siebenrock KA, Kalbermatten DF, Ganz R (2003) Effect of pelvic tilt on acetabular retroversion: a study of pelves from cadavers. Clin Orthop Relat Res 407:241–248CrossRefPubMed Siebenrock KA, Kalbermatten DF, Ganz R (2003) Effect of pelvic tilt on acetabular retroversion: a study of pelves from cadavers. Clin Orthop Relat Res 407:241–248CrossRefPubMed
19.
go back to reference Stokes IA (1994) Three-dimensional terminology of spinal deformities. A report presented to the Scoliosis Research Society by the Scoliosis Research Society Working Group a 3D terminology of spinal deformity. Spine 19:236–248PubMedCrossRef Stokes IA (1994) Three-dimensional terminology of spinal deformities. A report presented to the Scoliosis Research Society by the Scoliosis Research Society Working Group a 3D terminology of spinal deformity. Spine 19:236–248PubMedCrossRef
20.
go back to reference Tang WM, Chiu KY, Kwan MF et al (2007) Sagittal pelvic mal-rotation and positioning of the acetabular component in total hip arthroplasty: three-dimensional computer model analysis. J Orthop Res 25(6):766–771CrossRefPubMed Tang WM, Chiu KY, Kwan MF et al (2007) Sagittal pelvic mal-rotation and positioning of the acetabular component in total hip arthroplasty: three-dimensional computer model analysis. J Orthop Res 25(6):766–771CrossRefPubMed
21.
go back to reference Watanabe W, Sato K, Itoi E, Yang K, Watanabe H (2002) Posterior pelic tilt in patients with decreased lumbar lordosis decreases acetabular femoral head covering. Orthopaedics 25(3):321–324 Watanabe W, Sato K, Itoi E, Yang K, Watanabe H (2002) Posterior pelic tilt in patients with decreased lumbar lordosis decreases acetabular femoral head covering. Orthopaedics 25(3):321–324
22.
go back to reference Zilber S, Lazennec JY, Gorin M, Saillant G (2004) Variations of caudal, central, and cranial acetabular anteversion according to the tilt of the pelvis. Surg Radiol Anat 26(6):462–465CrossRefPubMed Zilber S, Lazennec JY, Gorin M, Saillant G (2004) Variations of caudal, central, and cranial acetabular anteversion according to the tilt of the pelvis. Surg Radiol Anat 26(6):462–465CrossRefPubMed
Metadata
Title
Influence of the sagittal balance of the spine on the anterior pelvic plane and on the acetabular orientation
Author
Jean Legaye
Publication date
01-12-2009
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 6/2009
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-008-0702-0

Other articles of this Issue 6/2009

International Orthopaedics 6/2009 Go to the issue