01-07-2013 | Guidelines

EANM Dosimetry Committee Series on Standard Operational Procedures for Pre-Therapeutic Dosimetry II. Dosimetry prior to radioiodine therapy of benign thyroid diseases

Authors: Heribert Hänscheid, Cristina Canzi, Wolfgang Eschner, Glenn Flux, Markus Luster, Lidia Strigari, Michael Lassmann

Published in: European Journal of Nuclear Medicine and Molecular Imaging | Issue 7/2013

Login to get access

Abstract

The EANM Dosimetry Committee Series “Standard Operational Procedures for Pre-Therapeutic Dosimetry” (SOP) provides advice to scientists and clinicians on how to perform patient-specific absorbed dose assessments. This particular SOP describes how to tailor the therapeutic activity to be administered for radioiodine therapy of benign thyroid diseases such as Graves’ disease or hyperthyroidism. Pretherapeutic dosimetry is based on the assessment of the individual 131I kinetics in the target tissue after the administration of a tracer activity. The present SOP makes proposals on the equipment to be used and guides the user through the measurements. Time schedules for the measurement of the fractional 131I uptake in the diseased tissue are recommended and it is shown how to calculate from these datasets the therapeutic activity necessary to administer a predefined target dose in the subsequent therapy. Potential sources of error are pointed out and the inherent uncertainties of the procedures depending on the number of measurements are discussed. The theoretical background and the derivation of the listed equations from compartment models of the iodine kinetics are explained in a supplementary file published online only.
Appendix
Available only for authorised users
Literature
1.
go back to reference Stokkel MP, Handkiewicz Junak D, Lassmann M, Dietlein M, Luster M. EANM procedure guidelines for therapy of benign thyroid disease. Eur J Nucl Med Mol Imaging. 2010;37:2218–28.PubMedCrossRef Stokkel MP, Handkiewicz Junak D, Lassmann M, Dietlein M, Luster M. EANM procedure guidelines for therapy of benign thyroid disease. Eur J Nucl Med Mol Imaging. 2010;37:2218–28.PubMedCrossRef
3.
go back to reference Salvatori M, Luster M. Radioiodine therapy dosimetry in benign thyroid disease and differentiated thyroid carcinoma. Eur J Nucl Med Mol Imaging. 2010;37:821–8.PubMedCrossRef Salvatori M, Luster M. Radioiodine therapy dosimetry in benign thyroid disease and differentiated thyroid carcinoma. Eur J Nucl Med Mol Imaging. 2010;37:821–8.PubMedCrossRef
4.
go back to reference Lassmann M, Chiesa C, Flux G, Bardies M. EANM Dosimetry Committee guidance document: good practice of clinical dosimetry reporting. Eur J Nucl Med Mol Imaging. 2011;38:192–200.PubMedCrossRef Lassmann M, Chiesa C, Flux G, Bardies M. EANM Dosimetry Committee guidance document: good practice of clinical dosimetry reporting. Eur J Nucl Med Mol Imaging. 2011;38:192–200.PubMedCrossRef
5.
go back to reference Hammes J, Pietrzyk U, Schmidt M, Schicha H, Eschner W. GATE based Monte Carlo simulation of planar scintigraphy to estimate the nodular dose in radioiodine therapy for autonomous thyroid adenoma. Z Med Phys. 2011;21:290–300.PubMedCrossRef Hammes J, Pietrzyk U, Schmidt M, Schicha H, Eschner W. GATE based Monte Carlo simulation of planar scintigraphy to estimate the nodular dose in radioiodine therapy for autonomous thyroid adenoma. Z Med Phys. 2011;21:290–300.PubMedCrossRef
6.
go back to reference Brunn J, Block U, Ruf G, Bos I, Kunze WP, Scriba PC. Volumetric analysis of thyroid lobes by real-time ultrasound. Dtsch Med Wochenschr. 1981;106:1338–40.PubMedCrossRef Brunn J, Block U, Ruf G, Bos I, Kunze WP, Scriba PC. Volumetric analysis of thyroid lobes by real-time ultrasound. Dtsch Med Wochenschr. 1981;106:1338–40.PubMedCrossRef
7.
go back to reference Schlögl S, Werner E, Lassmann M, Terekhova J, Muffert S, Seybold S, et al. The use of three-dimensional ultrasound for thyroid volumetry. Thyroid. 2001;11:569–74.PubMedCrossRef Schlögl S, Werner E, Lassmann M, Terekhova J, Muffert S, Seybold S, et al. The use of three-dimensional ultrasound for thyroid volumetry. Thyroid. 2001;11:569–74.PubMedCrossRef
8.
go back to reference Nygaard B, Nygaard T, Court-Payen M, Jensen LI, Soe-Jensen P, Gerhard Nielsen K, et al. Thyroid volume measured by ultrasonography and CT. Acta Radiol. 2002;43:269–74.PubMedCrossRef Nygaard B, Nygaard T, Court-Payen M, Jensen LI, Soe-Jensen P, Gerhard Nielsen K, et al. Thyroid volume measured by ultrasonography and CT. Acta Radiol. 2002;43:269–74.PubMedCrossRef
9.
go back to reference van Isselt JW, de Klerk JM, van Rijk PP, van Gils AP, Polman LJ, Kamphuis C, et al. Comparison of methods for thyroid volume estimation in patients with Graves’ disease. Eur J Nucl Med Mol Imaging. 2003;30:525–31.PubMedCrossRef van Isselt JW, de Klerk JM, van Rijk PP, van Gils AP, Polman LJ, Kamphuis C, et al. Comparison of methods for thyroid volume estimation in patients with Graves’ disease. Eur J Nucl Med Mol Imaging. 2003;30:525–31.PubMedCrossRef
10.
go back to reference Reinartz P, Sabri O, Zimny M, Nowak B, Cremerius U, Setani K, et al. Thyroid volume measurement in patients prior to radioiodine therapy: comparison between three-dimensional magnetic resonance imaging and ultrasonography. Thyroid. 2002;12:713–7.PubMedCrossRef Reinartz P, Sabri O, Zimny M, Nowak B, Cremerius U, Setani K, et al. Thyroid volume measurement in patients prior to radioiodine therapy: comparison between three-dimensional magnetic resonance imaging and ultrasonography. Thyroid. 2002;12:713–7.PubMedCrossRef
11.
go back to reference Canzi C, Zito F, Voltini F, Reschini E, Gerundini P. Verification of the agreement of two dosimetric methods with radioiodine therapy in hyperthyroid patients. Med Phys. 2006;33:2860–7.PubMedCrossRef Canzi C, Zito F, Voltini F, Reschini E, Gerundini P. Verification of the agreement of two dosimetric methods with radioiodine therapy in hyperthyroid patients. Med Phys. 2006;33:2860–7.PubMedCrossRef
12.
go back to reference Strigari L, Sciuto R, Benassi M, Bergomi S, Nocentini S, Maini CL. A NTCP approach for estimating the outcome in radioiodine treatment of hyperthyroidism. Med Phys. 2008;35:3903–10.PubMedCrossRef Strigari L, Sciuto R, Benassi M, Bergomi S, Nocentini S, Maini CL. A NTCP approach for estimating the outcome in radioiodine treatment of hyperthyroidism. Med Phys. 2008;35:3903–10.PubMedCrossRef
13.
go back to reference Eschmann SM, Reischl G, Bilger K, Kupferschläger J, Thelen MH, Dohmen BM, et al. Evaluation of dosimetry of radioiodine therapy in benign and malignant thyroid disorders by means of iodine-124 and PET. Eur J Nucl Med Mol Imaging. 2002;29:760–7.PubMedCrossRef Eschmann SM, Reischl G, Bilger K, Kupferschläger J, Thelen MH, Dohmen BM, et al. Evaluation of dosimetry of radioiodine therapy in benign and malignant thyroid disorders by means of iodine-124 and PET. Eur J Nucl Med Mol Imaging. 2002;29:760–7.PubMedCrossRef
14.
go back to reference Matheoud R, Canzi C, Reschini E, Zito F, Voltini F, Gerundini P. Tissue-specific dosimetry for radioiodine therapy of the autonomous thyroid nodule. Med Phys. 2003;30:791–8.PubMedCrossRef Matheoud R, Canzi C, Reschini E, Zito F, Voltini F, Gerundini P. Tissue-specific dosimetry for radioiodine therapy of the autonomous thyroid nodule. Med Phys. 2003;30:791–8.PubMedCrossRef
15.
go back to reference Szebeni A, Beleznay E. New simple method for thyroid volume determination by ultrasonography. J Clin Ultrasound. 1992;20:329–37.PubMedCrossRef Szebeni A, Beleznay E. New simple method for thyroid volume determination by ultrasonography. J Clin Ultrasound. 1992;20:329–37.PubMedCrossRef
16.
go back to reference Andermann P, Schlögl S, Mader U, Luster M, Lassmann M, Reiners C. Intra- and interobserver variability of thyroid volume measurements in healthy adults by 2D versus 3D ultrasound. Nuklearmedizin. 2007;46:1–7.PubMed Andermann P, Schlögl S, Mader U, Luster M, Lassmann M, Reiners C. Intra- and interobserver variability of thyroid volume measurements in healthy adults by 2D versus 3D ultrasound. Nuklearmedizin. 2007;46:1–7.PubMed
17.
go back to reference Knudsen N, Bols B, Bulow I, Jorgensen T, Perrild H, Ovesen L, et al. Validation of ultrasonography of the thyroid gland for epidemiological purposes. Thyroid. 1999;9:1069–74.PubMedCrossRef Knudsen N, Bols B, Bulow I, Jorgensen T, Perrild H, Ovesen L, et al. Validation of ultrasonography of the thyroid gland for epidemiological purposes. Thyroid. 1999;9:1069–74.PubMedCrossRef
18.
go back to reference Busemann Sokole E, Plachcinska A, Britten A. Acceptance testing for nuclear medicine instrumentation. Eur J Nucl Med Mol Imaging. 2010;37:672–81.PubMedCrossRef Busemann Sokole E, Plachcinska A, Britten A. Acceptance testing for nuclear medicine instrumentation. Eur J Nucl Med Mol Imaging. 2010;37:672–81.PubMedCrossRef
19.
go back to reference Busemann Sokole E, Plachcinska A, Britten A, Lyra Georgosopoulou M, Tindale W, Klett R. Routine quality control recommendations for nuclear medicine instrumentation. Eur J Nucl Med Mol Imaging. 2010;37:662–71.PubMedCrossRef Busemann Sokole E, Plachcinska A, Britten A, Lyra Georgosopoulou M, Tindale W, Klett R. Routine quality control recommendations for nuclear medicine instrumentation. Eur J Nucl Med Mol Imaging. 2010;37:662–71.PubMedCrossRef
20.
go back to reference Marinelli LD, Quimby EH, Hine GJ. Dosage determination with radioactive isotopes; practical considerations in therapy and protection. Am J Roentgenol Radium Ther. 1948;59:260–81.PubMed Marinelli LD, Quimby EH, Hine GJ. Dosage determination with radioactive isotopes; practical considerations in therapy and protection. Am J Roentgenol Radium Ther. 1948;59:260–81.PubMed
21.
go back to reference Bockisch A, Jamitzky T, Derwanz R, Biersack HJ. Optimized dose planning of radioiodine therapy of benign thyroidal diseases. J Nucl Med. 1993;34:1632–8.PubMed Bockisch A, Jamitzky T, Derwanz R, Biersack HJ. Optimized dose planning of radioiodine therapy of benign thyroidal diseases. J Nucl Med. 1993;34:1632–8.PubMed
22.
go back to reference Di Martino F, Traino AC, Brill AB, Stabin MG, Lazzer M. A theoretical model for prescription of the patient-specific therapeutic activity for radioiodine therapy of Graves’ disease. Phys Med Biol. 2002;47:1493–9.PubMedCrossRef Di Martino F, Traino AC, Brill AB, Stabin MG, Lazzer M. A theoretical model for prescription of the patient-specific therapeutic activity for radioiodine therapy of Graves’ disease. Phys Med Biol. 2002;47:1493–9.PubMedCrossRef
23.
go back to reference Jonsson H, Mattsson S. Single uptake measurement for absorbed dose planning for radioiodine treatment of hyperthyroidism. Cancer Biother Radiopharm. 2003;18:473–9.PubMedCrossRef Jonsson H, Mattsson S. Single uptake measurement for absorbed dose planning for radioiodine treatment of hyperthyroidism. Cancer Biother Radiopharm. 2003;18:473–9.PubMedCrossRef
24.
go back to reference Rink T, Bormuth FJ, Braun S, Zimny M, Schroth HJ. Concept and validation of a simple model of the intrathyroidal iodine kinetics. Nuklearmedizin. 2004;43:21–5.PubMed Rink T, Bormuth FJ, Braun S, Zimny M, Schroth HJ. Concept and validation of a simple model of the intrathyroidal iodine kinetics. Nuklearmedizin. 2004;43:21–5.PubMed
25.
go back to reference Areberg J, Jonsson H, Mattsson S. Population biokinetic modeling of thyroid uptake and retention of radioiodine. Cancer Biother Radiopharm. 2005;20:1–10.PubMedCrossRef Areberg J, Jonsson H, Mattsson S. Population biokinetic modeling of thyroid uptake and retention of radioiodine. Cancer Biother Radiopharm. 2005;20:1–10.PubMedCrossRef
26.
go back to reference Stabin MG, Sparks RB, Crowe E. OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023–7.PubMed Stabin MG, Sparks RB, Crowe E. OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023–7.PubMed
27.
go back to reference Carlier T, Salaun PY, Cavarec MB, Valette F, Turzo A, Bardies M, et al. Optimized radioiodine therapy for Graves’ disease: two MIRD-based models for the computation of patient-specific therapeutic 131I activity. Nucl Med Commun. 2006;27:559–66.PubMedCrossRef Carlier T, Salaun PY, Cavarec MB, Valette F, Turzo A, Bardies M, et al. Optimized radioiodine therapy for Graves’ disease: two MIRD-based models for the computation of patient-specific therapeutic 131I activity. Nucl Med Commun. 2006;27:559–66.PubMedCrossRef
28.
go back to reference Eckerman K, Endo A. MIRD: Radionuclide data and decay schemes. 2nd ed. New York: Society of Nuclear Medicine; 2008. Eckerman K, Endo A. MIRD: Radionuclide data and decay schemes. 2nd ed. New York: Society of Nuclear Medicine; 2008.
29.
go back to reference Merrill S, Horowitz J, Traino AC, Chipkin SR, Hollot CV, Chait Y. Accuracy and optimal timing of activity measurements in estimating the absorbed dose of radioiodine in the treatment of Graves’ disease. Phys Med Biol. 2011;56:557–71.PubMedCrossRef Merrill S, Horowitz J, Traino AC, Chipkin SR, Hollot CV, Chait Y. Accuracy and optimal timing of activity measurements in estimating the absorbed dose of radioiodine in the treatment of Graves’ disease. Phys Med Biol. 2011;56:557–71.PubMedCrossRef
30.
go back to reference Hänscheid H, Lassmann M, Reiners C. Dosimetry prior to I-131-therapy of benign thyroid disease. Z Med Phys. 2011;21:250–7.PubMedCrossRef Hänscheid H, Lassmann M, Reiners C. Dosimetry prior to I-131-therapy of benign thyroid disease. Z Med Phys. 2011;21:250–7.PubMedCrossRef
31.
go back to reference Traino AC, Di Martino F, Lazzeri M, Stabin MG. Influence of thyroid volume reduction on calculated dose in radioiodine therapy of Graves’ hyperthyroidism. Phys Med Biol. 2000;45:121–9.PubMedCrossRef Traino AC, Di Martino F, Lazzeri M, Stabin MG. Influence of thyroid volume reduction on calculated dose in radioiodine therapy of Graves’ hyperthyroidism. Phys Med Biol. 2000;45:121–9.PubMedCrossRef
Metadata
Title
EANM Dosimetry Committee Series on Standard Operational Procedures for Pre-Therapeutic Dosimetry II. Dosimetry prior to radioiodine therapy of benign thyroid diseases
Authors
Heribert Hänscheid
Cristina Canzi
Wolfgang Eschner
Glenn Flux
Markus Luster
Lidia Strigari
Michael Lassmann
Publication date
01-07-2013
Publisher
Springer-Verlag
Published in
European Journal of Nuclear Medicine and Molecular Imaging / Issue 7/2013
Print ISSN: 1619-7070
Electronic ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-013-2387-x

Other articles of this Issue 7/2013

European Journal of Nuclear Medicine and Molecular Imaging 7/2013 Go to the issue