01-09-2008 | Short Communication
The new EANM paediatric dosage card: additional notes with respect to F-18
Authors:
M. Lassmann, L. Biassoni, M. Monsieurs, C. Franzius, EANM Dosimetry and Paediatrics Committees
Published in:
European Journal of Nuclear Medicine and Molecular Imaging
|
Issue 9/2008
Login to get access
Abstract
Introduction
The previously published European Association of Nuclear Medicine (EANM) paediatric dosage card recommends 70 MBq F-18 or F-18 Fluoro-2-Deoxyglucose (F-18-FDG) as the “minimum recommended activity”.
Discussion
Two recent publications demonstrate that when utilising F-18-labelled radiopharmaceuticals the administration of lower activities for small children is possible without losing image quality.
Conclusion
In the light of these findings the EANM dosimetry and paediatrics committee have decided to reduce the value for the “minimum recommended activity” for both F-18 and F-18-FDG to 26 MBq for 2D- and 14 MBq for 3D-acquisitions.