Comparison of 180° and 360° data acquisition for determination of left ventricular function from gated myocardial perfusion tomography and gated blood pool tomography

Authors: Christian Vanhove, Philippe R. Franken, Michel Defrise, Axel Bossuyt

Published in: European Journal of Nuclear Medicine and Molecular Imaging | Issue 11/2003

Login to get access

Abstract

The purpose of this study was to address the issue of 180° versus 360° data collection for left ventricular ejection fraction (LVEF) and left ventricular volume measurements using gated myocardial perfusion tomography (gMPT) and gated blood pool tomography (gBPT). Thirty patients with known coronary artery disease were injected in a random sequence with 925 MBq of technetium-99m tetrofosmin and, within 2 days, with 740 MBq of 99mTc-labelled human serum albumin. gMPT and gBPT were acquired using 360° data collection and reconstructed by filtered backprojection using all the acquired projection images and separately using only projection images acquired from 45° LPO to 45° RAO. In order to have the same global count densities, the counts in the 360° data set were redistributed using binomial deviates just before reconstruction. After reorientation along the left ventricular long axis, LVEF and left ventricular volumes were calculated using fully automatic algorithms. Twenty-eight patients also underwent planar radionuclide angiocardiography (PRNA) on the same day as the gBPT. For the gMPT studies, the correlation between 180° data collection and 360° data collection was excellent (r>0.98). Bland-Altman analysis revealed small systematic and random differences (<6%) between 180° and 360°. For the gBPT studies, the correlation between 180° data collection and 360° data collection was very good (r>0.93). However, Bland-Altman analysis revealed systematic differences of 26% and random differences of 17%. When PRNA was used as a reference, the best results were obtained with gMPT acquired using 180° data, while the worst results were obtained with gBPT acquired using 180° data. In conclusion, when evaluating LVEF and left ventricular volumes from gMPT, either 180° or 360° orbits can be used. However, 360° data acquisition is recommended when evaluating LVEF and left ventricular volumes from gBPT.
Literature
1.
go back to reference Coleman RE, Jaszczak RJ, Cobb FR. Comparison of 180° and 360° data collection in thallium-201 imaging using single-photon emission computerized tomography (SPECT): concise communication. J Nucl Med 1982; 23:655–660.PubMed Coleman RE, Jaszczak RJ, Cobb FR. Comparison of 180° and 360° data collection in thallium-201 imaging using single-photon emission computerized tomography (SPECT): concise communication. J Nucl Med 1982; 23:655–660.PubMed
2.
go back to reference Knesaurek K, King MA, Glick SJ, Penny BC. Investigation of causes of geometric distortion in 180° and 360° angular sampling in SPECT. J Nucl Med 1989; 30:1666–1675.PubMed Knesaurek K, King MA, Glick SJ, Penny BC. Investigation of causes of geometric distortion in 180° and 360° angular sampling in SPECT. J Nucl Med 1989; 30:1666–1675.PubMed
3.
go back to reference Hoffman EJ. 180° compared with 360° sampling in SPECT. J Nucl Med 1982; 23:745–747.PubMed Hoffman EJ. 180° compared with 360° sampling in SPECT. J Nucl Med 1982; 23:745–747.PubMed
4.
go back to reference Liu YH, Lam PT, Sinusas AJ, Wackers FJ. Differential effect of 180° and 360° acquisition orbits on the accuracy of SPECT imaging: quantitative evaluation in phantoms. J Nucl Med 2002; 43:1115–1124.PubMed Liu YH, Lam PT, Sinusas AJ, Wackers FJ. Differential effect of 180° and 360° acquisition orbits on the accuracy of SPECT imaging: quantitative evaluation in phantoms. J Nucl Med 2002; 43:1115–1124.PubMed
5.
go back to reference Tamaki N, Mukai T, Ishii Y, Fujita T, Yamamoto K, Minato K, Yonekura Y, Tamaki S, Kambara H, Kawai C, Torizuka K. Comparative study of thallium emission myocardium tomography with 180° and 360° data collection. J Nucl Med 1982; 23:661–666. Tamaki N, Mukai T, Ishii Y, Fujita T, Yamamoto K, Minato K, Yonekura Y, Tamaki S, Kambara H, Kawai C, Torizuka K. Comparative study of thallium emission myocardium tomography with 180° and 360° data collection. J Nucl Med 1982; 23:661–666.
6.
go back to reference Freeman MR, Konstantinou C, Barr A, Greysin NC. Clinical comparison of 180° and 360° data collection of technetium 99m sestamibi SPECT for detection of coronary artery disease. J Nucl Cardiol 1998; 5:14–18.PubMed Freeman MR, Konstantinou C, Barr A, Greysin NC. Clinical comparison of 180° and 360° data collection of technetium 99m sestamibi SPECT for detection of coronary artery disease. J Nucl Cardiol 1998; 5:14–18.PubMed
7.
go back to reference Eisner RL, Nowak DJ, Pettigrew R, et al. Fundamentals of 180 degree acquisition and reconstruction in SPECT imaging. J Nucl Med 1986; 27:1717–1728.PubMed Eisner RL, Nowak DJ, Pettigrew R, et al. Fundamentals of 180 degree acquisition and reconstruction in SPECT imaging. J Nucl Med 1986; 27:1717–1728.PubMed
8.
go back to reference Maublant JC, Peycelon P, Kwiatkowski F, et al. Comparison between 180 degree and 360 degree data collection in technetium-99m MIBI SPECT of the myocardium. J Nucl Med 1989; 30:295–300.PubMed Maublant JC, Peycelon P, Kwiatkowski F, et al. Comparison between 180 degree and 360 degree data collection in technetium-99m MIBI SPECT of the myocardium. J Nucl Med 1989; 30:295–300.PubMed
9.
go back to reference DePuey EG, Garcia EV. Updated imaging guidelines for nuclear cardiology procedures. J Nucl Cardiol 2001; 8:G1–G58. DePuey EG, Garcia EV. Updated imaging guidelines for nuclear cardiology procedures. J Nucl Cardiol 2001; 8:G1–G58.
10.
go back to reference Snyder D, Miller M. Random point processes in time and space, 2nd edn. New York: Springer, 1991. Snyder D, Miller M. Random point processes in time and space, 2nd edn. New York: Springer, 1991.
11.
go back to reference Press WH, Teukolsky SA, Vetterling WT, Flannery BP. Numerical recipes in C. Cambridge: Cambridge University Press, 1992. Press WH, Teukolsky SA, Vetterling WT, Flannery BP. Numerical recipes in C. Cambridge: Cambridge University Press, 1992.
12.
go back to reference Devroye L. Non-uniform random variate generation. New York: Springer, 1986. Devroye L. Non-uniform random variate generation. New York: Springer, 1986.
13.
go back to reference Germano G, Kiat H, Kavanagh PB, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995; 36:2138–2147.PubMed Germano G, Kiat H, Kavanagh PB, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995; 36:2138–2147.PubMed
14.
go back to reference Vanhove C, Franken PR, Defrise M, Momen A, Everaert H, Bossuyt A. Automatic determination of left ventricular ejection fraction from gated blood pool tomography. J Nucl Med 2001; 42:401–407.PubMed Vanhove C, Franken PR, Defrise M, Momen A, Everaert H, Bossuyt A. Automatic determination of left ventricular ejection fraction from gated blood pool tomography. J Nucl Med 2001; 42:401–407.PubMed
15.
go back to reference Vanhove C, Franken PR. Left ventricular ejection fraction and volumes from gated blood pool tomography: comparison between two automatic algorithms working in three-dimensional space. J Nucl Cardiol 2001; 8:466–471.PubMed Vanhove C, Franken PR. Left ventricular ejection fraction and volumes from gated blood pool tomography: comparison between two automatic algorithms working in three-dimensional space. J Nucl Cardiol 2001; 8:466–471.PubMed
16.
go back to reference Vanhove C, Walgraeve N, De Geeter F, Franken PR. Gated myocardial perfusion tomography versus gated blood pool tomography to calculate left ventricular volumes and ejection fraction. Eur J Nucl Med 2002; 29:735–741.CrossRef Vanhove C, Walgraeve N, De Geeter F, Franken PR. Gated myocardial perfusion tomography versus gated blood pool tomography to calculate left ventricular volumes and ejection fraction. Eur J Nucl Med 2002; 29:735–741.CrossRef
17.
go back to reference Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurements. Lancet 1986; 1:307–310.PubMed Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurements. Lancet 1986; 1:307–310.PubMed
18.
go back to reference Kubo N, Mabuchi M, Katoh C, et al. Accuracy and reproducibility of left ventricular function from quantitative, gated, single photon emission computed tomography using dynamic myocardial phantoms: effect of pre-reconstruction filters. Nucl Med Commun 2002; 23:529–536.CrossRefPubMed Kubo N, Mabuchi M, Katoh C, et al. Accuracy and reproducibility of left ventricular function from quantitative, gated, single photon emission computed tomography using dynamic myocardial phantoms: effect of pre-reconstruction filters. Nucl Med Commun 2002; 23:529–536.CrossRefPubMed
19.
go back to reference Nakajima K, Taki J, Higuchi T, et al. Gated SPET quantification of small hearts: mathematical simulation and clinical application. Eur J Nucl Med 2000; 27:1372–1379. Nakajima K, Taki J, Higuchi T, et al. Gated SPET quantification of small hearts: mathematical simulation and clinical application. Eur J Nucl Med 2000; 27:1372–1379.
20.
go back to reference Achert A, King MA, Dahlberg ST, et al. An investigation of the estimation of ejection fractions and cardiac volumes by a quantitative gated SPECT software package on simulated gated SPECT images. J Nucl Cardiol 1998; 5:144–152.PubMed Achert A, King MA, Dahlberg ST, et al. An investigation of the estimation of ejection fractions and cardiac volumes by a quantitative gated SPECT software package on simulated gated SPECT images. J Nucl Cardiol 1998; 5:144–152.PubMed
21.
go back to reference Nakajima K, Higuchi T, Taki J, Kawano M, Tonami N. Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: comparison of 4 software programs. J Nucl Med 2001; 42:1571–1578.PubMed Nakajima K, Higuchi T, Taki J, Kawano M, Tonami N. Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: comparison of 4 software programs. J Nucl Med 2001; 42:1571–1578.PubMed
Metadata
Title
Comparison of 180° and 360° data acquisition for determination of left ventricular function from gated myocardial perfusion tomography and gated blood pool tomography
Authors
Christian Vanhove
Philippe R. Franken
Michel Defrise
Axel Bossuyt
Publication date
01-11-2003
Publisher
Springer-Verlag
Published in
European Journal of Nuclear Medicine and Molecular Imaging / Issue 11/2003
Print ISSN: 1619-7070
Electronic ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-003-1267-1

Other articles of this Issue 11/2003

European Journal of Nuclear Medicine and Molecular Imaging 11/2003 Go to the issue