Skip to main content
Top
Published in: Skeletal Radiology 12/2017

01-12-2017 | Scientific Article

Magnetic resonance cinematography of the fingers: a 3.0 Tesla feasibility study with comparison of incremental and continuous dynamic protocols

Authors: Thomas Bayer, Werner Adler, Rolf Janka, Michael Uder, Frank Roemer

Published in: Skeletal Radiology | Issue 12/2017

Login to get access

Abstract

Objective

To study the feasibility of magnetic resonance cinematography of the fingers (MRCF) with comparison of image quality of different protocols for depicting the finger anatomy during motion.

Materials and methods

MRCF was performed during a full flexion and extension movement in 14 healthy volunteers using a finger-gating device. Three real-time sequences (frame rates 17–59 images/min) and one proton density (PD) sequence (3 images/min) were acquired during incremental and continuous motion. Analyses were performed independently by three readers. Qualitative image analysis included Likert-scale grading from 0 (useless) to 5 (excellent) and specific visual analog scale (VAS) grading from 0 (insufficient) to 100 (excellent). Signal-to-noise calculation was performed. Overall percentage agreement and mean absolute disagreement were calculated.

Results

Within the real-time sequences a high frame-rate true fast imaging with steady-state free precession (TRUFI) yielded the best image quality with Likert and overall VAS scores of 3.0 ± 0.2 and 60.4 ± 25.3, respectively. The best sequence regarding image quality was an incremental PD with mean values of 4.8 ± 0.2 and 91.2 ± 9.4, respectively. Overall percentage agreement and mean absolute disagreement were 47.9 and 0.7, respectively. No statistically significant SNR differences were found between continuous and incremental motion for the real-time protocols.

Conclusion

MRCF is feasible with appropriate image quality during continuous motion using a finger-gating device. Almost perfect image quality is achievable with incremental PD imaging, which represents a compromise for MRCF with the drawback of prolonged scanning time.
Appendix
Available only for authorised users
Literature
1.
go back to reference Shellock FG, Mink JH, Deutsch A, Pressman BD. Kinematic magnetic resonance imaging of the joints: techniques and clinical applications. Magn Reson Q. 1991;7(2):104–35.PubMed Shellock FG, Mink JH, Deutsch A, Pressman BD. Kinematic magnetic resonance imaging of the joints: techniques and clinical applications. Magn Reson Q. 1991;7(2):104–35.PubMed
2.
go back to reference Quick HH, Ladd ME, Hoevel M, Bosk S, Debatin JF, Laub G, et al. Real-time MRI of joint movement with trueFISP. J Magn Reson Imaging. 2002;15(6):710–5.CrossRefPubMed Quick HH, Ladd ME, Hoevel M, Bosk S, Debatin JF, Laub G, et al. Real-time MRI of joint movement with trueFISP. J Magn Reson Imaging. 2002;15(6):710–5.CrossRefPubMed
3.
go back to reference Shellock FG, Mink JH, Deutsch AL, Foo TK, Sullenberger P. Patellofemoral joint: identification of abnormalities with active-movement, “unloaded” versus “loaded” kinematic MR imaging techniques. Radiology. 1993;188(2):575–8.CrossRefPubMed Shellock FG, Mink JH, Deutsch AL, Foo TK, Sullenberger P. Patellofemoral joint: identification of abnormalities with active-movement, “unloaded” versus “loaded” kinematic MR imaging techniques. Radiology. 1993;188(2):575–8.CrossRefPubMed
4.
go back to reference Muhle C, Brinkmann G, Brossmann J, Wesner F, Heller M. Kinematic MR imaging of the ankle—initial results with ultra-fast sequence imaging. Acta Radiol. 1997;38(5):885–9.CrossRefPubMed Muhle C, Brinkmann G, Brossmann J, Wesner F, Heller M. Kinematic MR imaging of the ankle—initial results with ultra-fast sequence imaging. Acta Radiol. 1997;38(5):885–9.CrossRefPubMed
5.
go back to reference Boutin RD, Buonocore MH, Immerman I, Ashwell Z, Sonico GJ, Szabo RM, et al. Real-time magnetic resonance imaging (MRI) during active wrist motion—initial observations. PLoS One. 2013;8(12):e84004.CrossRefPubMedPubMedCentral Boutin RD, Buonocore MH, Immerman I, Ashwell Z, Sonico GJ, Szabo RM, et al. Real-time magnetic resonance imaging (MRI) during active wrist motion—initial observations. PLoS One. 2013;8(12):e84004.CrossRefPubMedPubMedCentral
6.
go back to reference Nordmeyer-Massner JA, Pruessmann KP, Wyss M, Manoliu A, Hodler J, Andreisek G, et al. MR imaging of healthy knees in varying degrees of flexion using a stretchable coil array provides comparable image quality compared to a standard knee coil array. Eur J Radiol. 2016;85(3):518–23.CrossRefPubMed Nordmeyer-Massner JA, Pruessmann KP, Wyss M, Manoliu A, Hodler J, Andreisek G, et al. MR imaging of healthy knees in varying degrees of flexion using a stretchable coil array provides comparable image quality compared to a standard knee coil array. Eur J Radiol. 2016;85(3):518–23.CrossRefPubMed
7.
go back to reference Tempelaere C, Pierrart J, Lefevre-Colau MM, Vuillemin V, Cuenod CA, Hansen U, et al. Dynamic three-dimensional shoulder MRI during active motion for investigation of rotator cuff diseases. PLoS One. 2016;11(7):e0158563.CrossRefPubMedPubMedCentral Tempelaere C, Pierrart J, Lefevre-Colau MM, Vuillemin V, Cuenod CA, Hansen U, et al. Dynamic three-dimensional shoulder MRI during active motion for investigation of rotator cuff diseases. PLoS One. 2016;11(7):e0158563.CrossRefPubMedPubMedCentral
8.
go back to reference Bayer T, Schweizer A, Muller-Gerbl M, Bongartz G. Proximal interphalangeal joint volar plate configuration in the crimp grip position. J Hand Surg Am. 2012;37(5):899–905.CrossRefPubMed Bayer T, Schweizer A, Muller-Gerbl M, Bongartz G. Proximal interphalangeal joint volar plate configuration in the crimp grip position. J Hand Surg Am. 2012;37(5):899–905.CrossRefPubMed
9.
go back to reference Bayer T, Adler W, Schweizer A, Schoffl I, Uder M, Janka R. Evaluation of finger A3 pulley rupture in the crimp grip position-a magnetic resonance imaging cadaver study. Skelet Radiol. 2015;44(9):1279–85.CrossRef Bayer T, Adler W, Schweizer A, Schoffl I, Uder M, Janka R. Evaluation of finger A3 pulley rupture in the crimp grip position-a magnetic resonance imaging cadaver study. Skelet Radiol. 2015;44(9):1279–85.CrossRef
10.
go back to reference Klauser A, Frauscher F, Bodner G, Halpern EJ, Schocke MF, Springer P, et al. Finger pulley injuries in extreme rock climbers: depiction with dynamic US. Radiology. 2002;222(3):755–61.CrossRefPubMed Klauser A, Frauscher F, Bodner G, Halpern EJ, Schocke MF, Springer P, et al. Finger pulley injuries in extreme rock climbers: depiction with dynamic US. Radiology. 2002;222(3):755–61.CrossRefPubMed
11.
go back to reference Saito S, Suzuki Y. Biomechanics of the volar plate of the proximal interphalangeal joint: a dynamic ultrasonographic study. J Hand Surg Am. 2011;36(2):265–71.CrossRefPubMed Saito S, Suzuki Y. Biomechanics of the volar plate of the proximal interphalangeal joint: a dynamic ultrasonographic study. J Hand Surg Am. 2011;36(2):265–71.CrossRefPubMed
12.
go back to reference Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF. MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology. 2001;219(1):264–9.CrossRefPubMed Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF. MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology. 2001;219(1):264–9.CrossRefPubMed
13.
go back to reference Abolmaali ND, Schmitt J, Schwarz W, Toll DE, Hinterwimmer S, Vogl TJ. Visualization of the articular disk of the temporomandibular joint in near-real-time MRI: feasibility study. Eur Radiol. 2004;14(10):1889–94.CrossRefPubMed Abolmaali ND, Schmitt J, Schwarz W, Toll DE, Hinterwimmer S, Vogl TJ. Visualization of the articular disk of the temporomandibular joint in near-real-time MRI: feasibility study. Eur Radiol. 2004;14(10):1889–94.CrossRefPubMed
14.
go back to reference Morales H, Cornelius R. Imaging approach to Temporomandibular joint disorders. Clin Neuroradiol. 2016;26(1):5–22.CrossRefPubMed Morales H, Cornelius R. Imaging approach to Temporomandibular joint disorders. Clin Neuroradiol. 2016;26(1):5–22.CrossRefPubMed
15.
go back to reference Tomas X, Pomes J, Berenguer J, Quinto L, Nicolau C, Mercader JM, et al. MR imaging of temporomandibular joint dysfunction: a pictorial review. Radiographics. 2006;26(3):765–81.CrossRefPubMed Tomas X, Pomes J, Berenguer J, Quinto L, Nicolau C, Mercader JM, et al. MR imaging of temporomandibular joint dysfunction: a pictorial review. Radiographics. 2006;26(3):765–81.CrossRefPubMed
16.
go back to reference Tomas X, Pomes J, Berenguer J, Mercader JM, Pons F, Donoso L. Temporomandibular joint soft-tissue pathology, II: nondisc abnormalities. Semin Ultrasound CT MR. 2007;28(3):205–12.CrossRefPubMed Tomas X, Pomes J, Berenguer J, Mercader JM, Pons F, Donoso L. Temporomandibular joint soft-tissue pathology, II: nondisc abnormalities. Semin Ultrasound CT MR. 2007;28(3):205–12.CrossRefPubMed
17.
go back to reference Lasalarie JC, Serfaty JM, Carre C, Messika-Zeitoun D, Jeannot C, Schouman-Claeys E, et al. Accuracy of contrast-enhanced cine-MR sequences in the assessment of left ventricular function: comparison with precontrast cine-MR sequences. Results of a bicentric study. Eur Radiol. 2007;17(11):2838–44.CrossRefPubMed Lasalarie JC, Serfaty JM, Carre C, Messika-Zeitoun D, Jeannot C, Schouman-Claeys E, et al. Accuracy of contrast-enhanced cine-MR sequences in the assessment of left ventricular function: comparison with precontrast cine-MR sequences. Results of a bicentric study. Eur Radiol. 2007;17(11):2838–44.CrossRefPubMed
18.
go back to reference Grothues F, Boenigk H, Graessner J, Kanowski M, Klein HU. Balanced steady-state free precession vs segmented fast low-angle shot for the evaluation of ventricular volumes, mass, and function at 3 Tesla. J Magn Reson Imaging. 2007;26(2):392–400.CrossRefPubMed Grothues F, Boenigk H, Graessner J, Kanowski M, Klein HU. Balanced steady-state free precession vs segmented fast low-angle shot for the evaluation of ventricular volumes, mass, and function at 3 Tesla. J Magn Reson Imaging. 2007;26(2):392–400.CrossRefPubMed
Metadata
Title
Magnetic resonance cinematography of the fingers: a 3.0 Tesla feasibility study with comparison of incremental and continuous dynamic protocols
Authors
Thomas Bayer
Werner Adler
Rolf Janka
Michael Uder
Frank Roemer
Publication date
01-12-2017
Publisher
Springer Berlin Heidelberg
Published in
Skeletal Radiology / Issue 12/2017
Print ISSN: 0364-2348
Electronic ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-017-2742-2

Other articles of this Issue 12/2017

Skeletal Radiology 12/2017 Go to the issue

Test Yourself: Question

Chronic stiff, aching left foot

Browser's Notes

Browser’s notes